Mekhail Anwar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mekhail Anwar has a total of 149 co-authors. Here are the top co-authors by number of shared publications:
- Ali M. Niknejad
Department of Electrical Engineering and Computer Science (EECS), University of California, Berkeley, Berkeley, CA, USA
6 shared publications - Micah Roschelle
Department of Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, CA, USA
5 shared publications - Vladimir Stojanovic
Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, Berkeley, CA, USA
5 shared publications - Bruce E. Cohen
The Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, USA
4 shared publications - Hossein Najafiaghdam
Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, USA
4 shared publications - Asmaysinh Gharia
Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, UK
3 shared publications
Latest Publications
- 18 February 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17  (3) , 1409-1426
Versatile optical frontends for multicolor fluorescence imaging with miniaturized lensless sensors
Lensless imaging enables exceptionally compact fluorescence sensors, advancing applications in in vivo imaging and low-cost, point-of-care diagnostics. These sensors require a filter to block the excitation light while passing the weak fluorescent emissions. However, conventional thin-film interference filters are sensitive to angle of incidence (AOI), complicating their use in lensless systems. Here, we thoroughly analyze and optimize a technique using a fiber optic plate (FOP) to absorb off-axis light that would bleed through the interference filter and improve image resolution. Through simulations, we show that the numerical aperture (NA) of the FOP drives inherent design tradeoffs: collection efficiency improves rapidly with a higher NA, but at the cost of resolution, increased device thickness, and fluorescence excitation efficiency. To illustrate these tradeoffs, we optimize two optical frontend designs using FOPs with full-width at half maximums of 8.3° and 45.7°. Implementing these designs, we show that to maintain performance across all AOIs, filters must be coated on both sides of the FOP to mitigate internal scattering effects. In imaging experiments, the 520-µm-thick high-NA design collects 59× more light, but its resolution degrades rapidly with increased working distances. Alternatively, the low-NA design is capable of three-color fluorescence imaging with at least 110-µm resolution at a 1-mm working distance. Overall, we demonstrate a versatile optical frontend that is adaptable to a range of applications using different fluorophores, illumination configurations, and lensless imaging techniques.
- 18 February 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17  (3) , 1409-1426
Versatile optical frontends for multicolor fluorescence imaging with miniaturized lensless sensors
Lensless imaging enables exceptionally compact fluorescence sensors, advancing applications in in vivo imaging and low-cost, point-of-care diagnostics. These sensors require a filter to block the excitation light while passing the weak fluorescent emissions. However, conventional thin-film interference filters are sensitive to angle of incidence (AOI), complicating their use in lensless systems. Here, we thoroughly analyze and optimize a technique using a fiber optic plate (FOP) to absorb off-axis light that would bleed through the interference filter and improve image resolution. Through simulations, we show that the numerical aperture (NA) of the FOP drives inherent design tradeoffs: collection efficiency improves rapidly with a higher NA, but at the cost of resolution, increased device thickness, and fluorescence excitation efficiency. To illustrate these tradeoffs, we optimize two optical frontend designs using FOPs with full-width at half maximums of 8.3° and 45.7°. Implementing these designs, we show that to maintain performance across all AOIs, filters must be coated on both sides of the FOP to mitigate internal scattering effects. In imaging experiments, the 520-µm-thick high-NA design collects 59× more light, but its resolution degrades rapidly with increased working distances. Alternatively, the low-NA design is capable of three-color fluorescence imaging with at least 110-µm resolution at a 1-mm working distance. Overall, we demonstrate a versatile optical frontend that is adaptable to a range of applications using different fluorophores, illumination configurations, and lensless imaging techniques.
- Open Access
- 17 February 2026
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 125  (5) , 1522-1533
Continuous, Preclinical Activity Reconstruction in 177Lu-based Radiopharmaceutical Therapy Using a Sparse Uncollimated γ-Sensor Network
- 17 February 2026
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 125  (5) , 1522-1533
Open AccessContinuous, Preclinical Activity Reconstruction in 177Lu-based Radiopharmaceutical Therapy Using a Sparse Uncollimated γ-Sensor Network
- Open Access
- 18 December 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Precision Labeling of Native Antibodies with Lock Coupling
The formation of stable protein complexes enables much of biotechnology, but even high-affinity complexes can dissociate, limiting potential applications in biomaterials development, bioimaging, nanomedicine, and other protein-based technologies. Here, we describe Lock coupling, a simple and selective one-step reaction between interfacial lysine and glutamate or aspartate sidechains to form stable isopeptide bonds and be used for the precise labeling of native antibodies. We identify conditions in which short-lived activated esters formed by the aqueous carbodiimide EDC promote isopeptide bond formation specifically at pre-associated amine-acid pairs. Indiscriminate crosslinking is minimized by formation of protein complexes before addition of catalyst, use of acidic pH to suppress exposed Lys reactivity, and limiting the aqueous stability of activated esters. For native antibody (Ab) labeling, we show that the small IgG-binding protein GB1 can be covalently attached to the Ab Fc domain, and introduction of Cys into GB1 loops allows for facile conjugation of fluorophores, micelles, or inorganic nanocrystals for imaging in live cells and animals. By varying Cys substituents and protein stoichiometry, a defined number of probes can be uniformly attached without the need for extensive purification. In live-cell confocal microscopy, labeled GB1 serves as a stable replacement for secondary Ab, enabling simple multicolor immunostaining and imaging. Lock coupling requires just a single reagent in aqueous buffer and leverages both the innate ability of proteins to form high-affinity complexes and the widespread presence of Lys-Glu/Asp pairs at their interfaces, with potential for precision synthesis of protein-based probes for imaging, biomaterials, biophysics, and medicine.
- 18 December 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessPrecision Labeling of Native Antibodies with Lock Coupling
The formation of stable protein complexes enables much of biotechnology, but even high-affinity complexes can dissociate, limiting potential applications in biomaterials development, bioimaging, nanomedicine, and other protein-based technologies. Here, we describe Lock coupling, a simple and selective one-step reaction between interfacial lysine and glutamate or aspartate sidechains to form stable isopeptide bonds and be used for the precise labeling of native antibodies. We identify conditions in which short-lived activated esters formed by the aqueous carbodiimide EDC promote isopeptide bond formation specifically at pre-associated amine-acid pairs. Indiscriminate crosslinking is minimized by formation of protein complexes before addition of catalyst, use of acidic pH to suppress exposed Lys reactivity, and limiting the aqueous stability of activated esters. For native antibody (Ab) labeling, we show that the small IgG-binding protein GB1 can be covalently attached to the Ab Fc domain, and introduction of Cys into GB1 loops allows for facile conjugation of fluorophores, micelles, or inorganic nanocrystals for imaging in live cells and animals. By varying Cys substituents and protein stoichiometry, a defined number of probes can be uniformly attached without the need for extensive purification. In live-cell confocal microscopy, labeled GB1 serves as a stable replacement for secondary Ab, enabling simple multicolor immunostaining and imaging. Lock coupling requires just a single reagent in aqueous buffer and leverages both the innate ability of proteins to form high-affinity complexes and the widespread presence of Lys-Glu/Asp pairs at their interfaces, with potential for precision synthesis of protein-based probes for imaging, biomaterials, biophysics, and medicine.
- Open Access
Configurable γ Photon Spectrometer to Enable Precision Radioguided Tumor Resection
Surgical tumor resection aims to remove all cancer cells in the tumor margin and at centimeter-scale depths below the tissue surface. During surgery, microscopic clusters of disease are intraoperatively difficult to visualize and are often left behind, significantly increasing the risk of cancer recurrence. Radioguided surgery (RGS) has shown the ability to selectively tag cancer cells with gamma (γ) photon emitting radioisotopes to identify them, but require a mm-scale γ photon spectrometer to localize the position of these cells in the tissue margin (i.e., a function of incident γ photon energy) with high specificity. Here we present a 9.9 mm2 integrated circuit (IC)-based γ spectrometer implemented in 180 nm CMOS, to enable the measurement of single γ photons and their incident energy with sub-keV energy resolution. We use small 2 2 um reverse-biased diodes that have low depletion region capacitance, and therefore produce millivolt-scale voltage signals in response to the small charge generated by incident γ photons. A low-power energy spectrometry method is implemented by measuring the decay time it takes for the generated voltage signal to settle back to DC after a γ detection event, instead of measuring the voltage drop directly. This spectrometry method is implemented in three different pixel architectures that allow for configurable pixel sensitivity, energy-resolution, and energy dynamic range based on the widely heterogenous surgical and patient presentation in RGS. The spectrometer was tested with three common γ-emitting radioisotopes (64Cu, 133Ba, 177Lu), and is able to resolve activities down to 1 uCi with sub-keV energy resolution and 1.315 MeV energy dynamic range, using 5-minute acquisitions.
Open AccessConfigurable γ Photon Spectrometer to Enable Precision Radioguided Tumor Resection
Surgical tumor resection aims to remove all cancer cells in the tumor margin and at centimeter-scale depths below the tissue surface. During surgery, microscopic clusters of disease are intraoperatively difficult to visualize and are often left behind, significantly increasing the risk of cancer recurrence. Radioguided surgery (RGS) has shown the ability to selectively tag cancer cells with gamma (γ) photon emitting radioisotopes to identify them, but require a mm-scale γ photon spectrometer to localize the position of these cells in the tissue margin (i.e., a function of incident γ photon energy) with high specificity. Here we present a 9.9 mm2 integrated circuit (IC)-based γ spectrometer implemented in 180 nm CMOS, to enable the measurement of single γ photons and their incident energy with sub-keV energy resolution. We use small 2 2 um reverse-biased diodes that have low depletion region capacitance, and therefore produce millivolt-scale voltage signals in response to the small charge generated by incident γ photons. A low-power energy spectrometry method is implemented by measuring the decay time it takes for the generated voltage signal to settle back to DC after a γ detection event, instead of measuring the voltage drop directly. This spectrometry method is implemented in three different pixel architectures that allow for configurable pixel sensitivity, energy-resolution, and energy dynamic range based on the widely heterogenous surgical and patient presentation in RGS. The spectrometer was tested with three common γ-emitting radioisotopes (64Cu, 133Ba, 177Lu), and is able to resolve activities down to 1 uCi with sub-keV energy resolution and 1.315 MeV energy dynamic range, using 5-minute acquisitions.
- 5 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19  (6) , 1048-1064
Configurable γ Photon Spectrometer to Enable Precision Radioguided Tumor Resection
Surgical tumor resection aims to remove all cancer cells in the tumor margin and at centimeter-scale depths below the tissue surface. During surgery, microscopic clusters of disease are intraoperatively difficult to visualize and are often left behind, significantly increasing the risk of cancer recurrence. Radioguided surgery (RGS) has shown the ability to selectively tag cancer cells with gamma (γ) photon emitting radioisotopes to identify them, but require a mm-scale γ photon spectrometer to localize the position of these cells in the tissue margin (i.e., a function of incident γ photon energy) with high specificity. Here we present a 9.9 mm2 integrated circuit (IC)-based γ spectrometer implemented in 180 nm CMOS, to enable the measurement of single γ photons and their incident energy with sub-keV energy resolution. We use small 2 × 2 μm reverse-biased diodes that have low depletion region capacitance, and therefore produce millivolt-scale voltage signals in response to the small charge generated by incident γ photons. A low-power energy spectrometry method is implemented by measuring the decay time it takes for the generated voltage signal to settle back to DC after a γ detection event, instead of measuring the voltage drop directly. This spectrometry method is implemented in three different pixel architectures that allow for configurable pixel sensitivity, energy-resolution, and energy dynamic range based on the widely heterogenous surgical and patient presentation in RGS. The spectrometer was tested with three common γ-emitting radioisotopes (64Cu, 133Ba, 177Lu), and is able to resolve activities down to 1 μCi with sub-keV energy resolution and 1.315 MeV energy dynamic range, using 5-minute acquisitions.
- 5 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19  (6) , 1048-1064
Configurable γ Photon Spectrometer to Enable Precision Radioguided Tumor Resection
Surgical tumor resection aims to remove all cancer cells in the tumor margin and at centimeter-scale depths below the tissue surface. During surgery, microscopic clusters of disease are intraoperatively difficult to visualize and are often left behind, significantly increasing the risk of cancer recurrence. Radioguided surgery (RGS) has shown the ability to selectively tag cancer cells with gamma (γ) photon emitting radioisotopes to identify them, but require a mm-scale γ photon spectrometer to localize the position of these cells in the tissue margin (i.e., a function of incident γ photon energy) with high specificity. Here we present a 9.9 mm2 integrated circuit (IC)-based γ spectrometer implemented in 180 nm CMOS, to enable the measurement of single γ photons and their incident energy with sub-keV energy resolution. We use small 2 × 2 μm reverse-biased diodes that have low depletion region capacitance, and therefore produce millivolt-scale voltage signals in response to the small charge generated by incident γ photons. A low-power energy spectrometry method is implemented by measuring the decay time it takes for the generated voltage signal to settle back to DC after a γ detection event, instead of measuring the voltage drop directly. This spectrometry method is implemented in three different pixel architectures that allow for configurable pixel sensitivity, energy-resolution, and energy dynamic range based on the widely heterogenous surgical and patient presentation in RGS. The spectrometer was tested with three common γ-emitting radioisotopes (64Cu, 133Ba, 177Lu), and is able to resolve activities down to 1 μCi with sub-keV energy resolution and 1.315 MeV energy dynamic range, using 5-minute acquisitions.
- Open Access
- 4 April 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 34, 100762
A 0.05 mm3 diode-based single charged-particle real-time radiation detector for electron radiotherapy
- 4 April 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 34, 100762
Open AccessA 0.05 mm3 diode-based single charged-particle real-time radiation detector for electron radiotherapy
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 60  (4) , 1423-1436
Single-X-Ray Sensitive Energy-Binning Dosimeter for Closed-Loop Cancer External-Beam Radiotherapy
X-ray radiation dose delivered during cancer external-beam radiotherapy (EBRT) is nonlinear with the biological effect imparted to cancer cells and neighboring healthy tissues. This oftentimes leads to insufficient damage to cancer cells and excessive damage to the surrounding healthy tissues, both increasing toxicity and the risk of cancer recurrence later in life for many patients. An understanding of X-ray energy deposition at the single-X-ray level is, therefore, necessary to improve the efficacy of cancer radiotherapy. Here, we present a single-X-ray sensitive, energy-binning integrated circuit (IC)-based dosimeter, fabricated in 180 nm CMOS technology, to enable closed-loop cancer radiotherapy for personalized patient treatment. We use small $3{\times }3~{\mu }$ m reverse-biased deep n-well (DNWELL) diodes designed at low capacitive nodes ( ${C} {_{\mathrm {diode}}}$ ), such that the miniscule charge deposition ( ${Q} {_{\mathrm {dep}}}$ ) from single X-rays at these nodes generates a voltage signal large enough to be sensed ( ${V} {_{\mathrm {diode}}}{=}{Q} {_{\mathrm {dep}}}$ / ${C} {_{\mathrm {diode}}}$ ). In order to enable single-X-ray energy resolution without significant power and area, we implement an analog voltage supply (AVDDH) ~log resistor grid to create a sensitivity gradient across the $76{\times }55$ pixel array. The IC-based dosimeter was tested under scenarios consistent with the treatment of shallow lesions (e.g., skin cancer, superficial tumors, intraoperative radiotherapy). The system is highly linear with radiation dose (10–250 cGy) and accurately tracks dose up to 2 cm deep in tissue for 50-, 70-, and 100-kV X-ray beams.
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 60  (4) , 1423-1436
Single-X-Ray Sensitive Energy-Binning Dosimeter for Closed-Loop Cancer External-Beam Radiotherapy
X-ray radiation dose delivered during cancer external-beam radiotherapy (EBRT) is nonlinear with the biological effect imparted to cancer cells and neighboring healthy tissues. This oftentimes leads to insufficient damage to cancer cells and excessive damage to the surrounding healthy tissues, both increasing toxicity and the risk of cancer recurrence later in life for many patients. An understanding of X-ray energy deposition at the single-X-ray level is, therefore, necessary to improve the efficacy of cancer radiotherapy. Here, we present a single-X-ray sensitive, energy-binning integrated circuit (IC)-based dosimeter, fabricated in 180 nm CMOS technology, to enable closed-loop cancer radiotherapy for personalized patient treatment. We use small $3{\times }3~{\mu }$ m reverse-biased deep n-well (DNWELL) diodes designed at low capacitive nodes ( ${C} {_{\mathrm {diode}}}$ ), such that the miniscule charge deposition ( ${Q} {_{\mathrm {dep}}}$ ) from single X-rays at these nodes generates a voltage signal large enough to be sensed ( ${V} {_{\mathrm {diode}}}{=}{Q} {_{\mathrm {dep}}}$ / ${C} {_{\mathrm {diode}}}$ ). In order to enable single-X-ray energy resolution without significant power and area, we implement an analog voltage supply (AVDDH) ~log resistor grid to create a sensitivity gradient across the $76{\times }55$ pixel array. The IC-based dosimeter was tested under scenarios consistent with the treatment of shallow lesions (e.g., skin cancer, superficial tumors, intraoperative radiotherapy). The system is highly linear with radiation dose (10–250 cGy) and accurately tracks dose up to 2 cm deep in tissue for 50-, 70-, and 100-kV X-ray beams.
- 8 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 59  (11) , 3580-3598
A Wireless, Multicolor Fluorescence Image Sensor Implant for Real-Time Monitoring in Cancer Therapy
Real-time monitoring of dynamic biological processes in the body is critical to understanding disease progression and treatment response. These data, for instance, can help address the lower than 50% response rates to cancer immunotherapy. However, current clinical imaging modalities lack the molecular contrast, resolution, and chronic usability for rapid and accurate response assessments. Here, we present a fully wireless image sensor featuring a $2.5{\times }5$ mm2 CMOS integrated circuit for multicolor fluorescence imaging deep in tissue. The sensor operates wirelessly via ultrasound (US) at 5-cm depth in oil, harvesting energy with 221-mW/cm2 incident US power density (31% of FDA limits) and backscattering data at 13 kb/s with a bit error rate $\lt 10{^{-6}}$ . In situ fluorescence excitation is provided by micro-laser diodes controlled with a programmable on-chip driver. An optical front-end combining a multi-bandpass interference filter and a fiber optic plate (FOP) provides >6 OD excitation blocking and enables three-color imaging for detecting multiple cell types. A $36{\times }40$ pixel array captures images with $\mu $ m resolution. We demonstrate wireless, dual-color fluorescence imaging of both effector and suppressor immune cells in ex vivo mouse tumor samples with and without immunotherapy. These results show promise for providing rapid insight into therapeutic response and resistance, guiding personalized medicine.
- 8 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 59  (11) , 3580-3598
A Wireless, Multicolor Fluorescence Image Sensor Implant for Real-Time Monitoring in Cancer Therapy
Real-time monitoring of dynamic biological processes in the body is critical to understanding disease progression and treatment response. These data, for instance, can help address the lower than 50% response rates to cancer immunotherapy. However, current clinical imaging modalities lack the molecular contrast, resolution, and chronic usability for rapid and accurate response assessments. Here, we present a fully wireless image sensor featuring a $2.5{\times }5$ mm2 CMOS integrated circuit for multicolor fluorescence imaging deep in tissue. The sensor operates wirelessly via ultrasound (US) at 5-cm depth in oil, harvesting energy with 221-mW/cm2 incident US power density (31% of FDA limits) and backscattering data at 13 kb/s with a bit error rate $\lt 10{^{-6}}$ . In situ fluorescence excitation is provided by micro-laser diodes controlled with a programmable on-chip driver. An optical front-end combining a multi-bandpass interference filter and a fiber optic plate (FOP) provides >6 OD excitation blocking and enables three-color imaging for detecting multiple cell types. A $36{\times }40$ pixel array captures images with $\mu $ m resolution. We demonstrate wireless, dual-color fluorescence imaging of both effector and suppressor immune cells in ex vivo mouse tumor samples with and without immunotherapy. These results show promise for providing rapid insight into therapeutic response and resistance, guiding personalized medicine.
- 9 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 59  (9) , 2907-2921
Monolithic Electronic–Biophotonic System-on-Chip for Label-Free Real-Time Molecular Sensing
Label-free miniaturized optical sensors can have a tremendous impact on highly sensitive and scalable point-of-care (PoC) diagnostics by monitoring real-time molecular interactions without any labels. However, current biophotonic platforms are limited by complex optical and external readout equipment, precluding their use in a PoC setting. In this work, we address this challenge by developing a first-of-its-kind fully integrated electronic–photonic label-free molecular sensor utilizing microring resonators (MRRs) co-integrated with on-chip electronics in a high-volume advanced electronic process. In particular, we present an arrayed electronic–photonic system-on-chip (EPSoC) in GlobalFoundries (GF) 45-nm RFSOI with 60 5- $\mu \text{m}$ radius MRRs connected to on-chip receivers, approaching an idealized limit of detection (LoD) equivalent to a single 140-nm viral particle. To further enhance the LoD, we propose a dual-ring phase-based sensing architecture, boosting the system’s sensitivity by $3.7\times $ compared to our previously reported intensity-based single MRR scheme. An integrated heater embedded in the design of the ring and an on-chip controller locks the ring’s resonance at the desired point of operation, eliminating the need for a tunable laser. The inherent intrinsic limitations of MRRs due to ambient temperature variations are addressed with an on-chip differential scheme using sensing and reference rings to cancel common mode errors. We demonstrate the sensing capabilities of the EPSoC by monitoring in real-time binding events of bovine serum albumin (BSA), anti-BSA molecules, and streptavidin-coated nanoparticles, unlocking the door toward self-contained fully integrated lab-on-chip (LoC) photonic sensors for PoC applications.
- 9 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 59  (9) , 2907-2921
Monolithic Electronic–Biophotonic System-on-Chip for Label-Free Real-Time Molecular Sensing
Label-free miniaturized optical sensors can have a tremendous impact on highly sensitive and scalable point-of-care (PoC) diagnostics by monitoring real-time molecular interactions without any labels. However, current biophotonic platforms are limited by complex optical and external readout equipment, precluding their use in a PoC setting. In this work, we address this challenge by developing a first-of-its-kind fully integrated electronic–photonic label-free molecular sensor utilizing microring resonators (MRRs) co-integrated with on-chip electronics in a high-volume advanced electronic process. In particular, we present an arrayed electronic–photonic system-on-chip (EPSoC) in GlobalFoundries (GF) 45-nm RFSOI with 60 5- $\mu \text{m}$ radius MRRs connected to on-chip receivers, approaching an idealized limit of detection (LoD) equivalent to a single 140-nm viral particle. To further enhance the LoD, we propose a dual-ring phase-based sensing architecture, boosting the system’s sensitivity by $3.7\times $ compared to our previously reported intensity-based single MRR scheme. An integrated heater embedded in the design of the ring and an on-chip controller locks the ring’s resonance at the desired point of operation, eliminating the need for a tunable laser. The inherent intrinsic limitations of MRRs due to ambient temperature variations are addressed with an on-chip differential scheme using sensing and reference rings to cancel common mode errors. We demonstrate the sensing capabilities of the EPSoC by monitoring in real-time binding events of bovine serum albumin (BSA), anti-BSA molecules, and streptavidin-coated nanoparticles, unlocking the door toward self-contained fully integrated lab-on-chip (LoC) photonic sensors for PoC applications.