Jonas Gienger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jonas Gienger has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Jörg Neukammer
Physikalisch-Technische Bundesanstalt (PTB), Abbestrasse 2-12, 10587 Berlin, Germany
5 shared publicationsMarkus Bär
Physikalisch-Technische Bundesanstalt (PTB), Abbestrasse 2-12, 10587 Berlin, Germany
5 shared publicationsHermann Gross
Physikalisch-Technische Bundesanstalt (PTB), Abbestrasse 2-12, 10587 Berlin, Germany
2 shared publications- Igor Michailovitsch Sokolov
Humboldt-Universität zu Berlin
2 shared publications - Jürgen Rabe
Department of Physics & IRIS Adlershof, Humboldt-Universität zu Berlin, Berlin, Germany
2 shared publications - Nikolai Severin
Humboldt-Universität zu Berlin
2 shared publications
Latest Publications
- Open Access
- 20 July 2026
- Published by Wiley in Cytometry Part A
- Vol. 109 (8) , 593-604
Coincidence Detection in Flow Cytometry Using Pulse‐Shape Analysis in Polydisperse Suspensions
Flow cytometers, based on an optical measurement principle, are widely used for cell characterization in a variety of medical applications. Especially in hematology, high counting accuracy is crucial. Therefore, it is essential to develop accurate but also fast coincidence correction methods. We developed a procedure for post‐processing the time‐dependent signals (pulses) captured by the detectors during the transition of particles or cells through the flow cytometer's laser beam. These pulses are characterized by their area, maximum intensity, standard deviation, and skewness. By using standard deviation versus area, we are able to detect significantly more coincidences in monodisperse suspensions than by using the common method of area or width versus height. This demonstrates the superior sensitivity and accuracy of our approach for coincidence detection. In polydisperse suspensions and whole blood, we successfully identify and distinguish coincidences between differently sized particles (e.g., 1 and 5 μm) and particles of the same size, as well as between thrombocytes and erythrocytes based on pulse skewness and standard deviation. Unlike the current state‐of‐the‐art method for coincidence correction in cell concentration measurements, which relies on statistical evaluation through dilution series, the developed procedure identifies a specific number of coincidences for individual measurements.
- 20 July 2026
- Published by Wiley in Cytometry Part A
- Vol. 109 (8) , 593-604
Open AccessCoincidence Detection in Flow Cytometry Using Pulse‐Shape Analysis in Polydisperse Suspensions
Flow cytometers, based on an optical measurement principle, are widely used for cell characterization in a variety of medical applications. Especially in hematology, high counting accuracy is crucial. Therefore, it is essential to develop accurate but also fast coincidence correction methods. We developed a procedure for post‐processing the time‐dependent signals (pulses) captured by the detectors during the transition of particles or cells through the flow cytometer's laser beam. These pulses are characterized by their area, maximum intensity, standard deviation, and skewness. By using standard deviation versus area, we are able to detect significantly more coincidences in monodisperse suspensions than by using the common method of area or width versus height. This demonstrates the superior sensitivity and accuracy of our approach for coincidence detection. In polydisperse suspensions and whole blood, we successfully identify and distinguish coincidences between differently sized particles (e.g., 1 and 5 μm) and particles of the same size, as well as between thrombocytes and erythrocytes based on pulse skewness and standard deviation. Unlike the current state‐of‐the‐art method for coincidence correction in cell concentration measurements, which relies on statistical evaluation through dilution series, the developed procedure identifies a specific number of coincidences for individual measurements.
- Open Access
- 18 August 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (24) , 7154-7167
Pulse shapes of angle- and time-resolved scattering and interference signals in a flow cytometer
Particles passing through a focused laser beam in a flow cytometer cause time-dependent angular intensity distributions of the scattered light, which can be detected as signal pulses of a few microseconds in length. Extinction effects are observed due to interference between the incident beam and scattered light near the forward direction. We present angle-resolved measurements of such pulses for polymer microparticles using an optical fiber array. Even for homogeneous spherical particles, this can result in pulses with non-trivial shapes that carry information about the particles. We compare with results from mathematical modeling based on generalized Lorenz–Mie theory for the scattering of elliptical Gaussian beams by spherical particles at arbitrary locations.
- 18 August 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (24) , 7154-7167
Open AccessPulse shapes of angle- and time-resolved scattering and interference signals in a flow cytometer
Particles passing through a focused laser beam in a flow cytometer cause time-dependent angular intensity distributions of the scattered light, which can be detected as signal pulses of a few microseconds in length. Extinction effects are observed due to interference between the incident beam and scattered light near the forward direction. We present angle-resolved measurements of such pulses for polymer microparticles using an optical fiber array. Even for homogeneous spherical particles, this can result in pulses with non-trivial shapes that carry information about the particles. We compare with results from mathematical modeling based on generalized Lorenz–Mie theory for the scattering of elliptical Gaussian beams by spherical particles at arbitrary locations.
- Open Access
On the interference of the scattered wave and the incident wave in light scattering problems with Gaussian beams
We consider the light scattering problem for a Gaussian beam and a (spherical) particle at arbitrary location. Within the beam cross section, the total electromagnetic field is the superposition of the incident beam and the scattered wave. Using the Generalized Lorenz-Mie Theory (GLMT) as a vehicle to access such scattering problems, we discuss the mathematical modeling of this interference at short, large but finite and infinite distances from the scatterer. We show how to eliminate the errors that can arise from improper modeling in the most straight-forward manner, that is superimposing the scattered wave with the closed-form expression for the Gaussian beam at a finite distance from the particle. GLMT uses a low order beam model ($s^1$), but using the known higher order models ($s^3$, $s^5$, $s^7$, ...) would not mitigate these errors as we discuss. The challenge lies in an appropriate description of the Gaussian beam at arbitrary distances from its focus, not in its description on the scale of a particle (located in or near the focus) nor in the expressions for the scattered field. Hence, the solutions described here can readily be extended to light scattering frameworks other than GLMT and are thus also relevant for non-spherical particles.Open AccessOn the interference of the scattered wave and the incident wave in light scattering problems with Gaussian beams
We consider the light scattering problem for a Gaussian beam and a (spherical) particle at arbitrary location. Within the beam cross section, the total electromagnetic field is the superposition of the incident beam and the scattered wave. Using the Generalized Lorenz-Mie Theory (GLMT) as a vehicle to access such scattering problems, we discuss the mathematical modeling of this interference at short, large but finite and infinite distances from the scatterer. We show how to eliminate the errors that can arise from improper modeling in the most straight-forward manner, that is superimposing the scattered wave with the closed-form expression for the Gaussian beam at a finite distance from the particle. GLMT uses a low order beam model ($s^1$), but using the known higher order models ($s^3$, $s^5$, $s^7$, ...) would not mitigate these errors as we discuss. The challenge lies in an appropriate description of the Gaussian beam at arbitrary distances from its focus, not in its description on the scale of a particle (located in or near the focus) nor in the expressions for the scattered field. Hence, the solutions described here can readily be extended to light scattering frameworks other than GLMT and are thus also relevant for non-spherical particles. - Open Access
- 10 February 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (4) , 1753
Function of Hemoglobin-Based Oxygen Carriers: Determination of Methemoglobin Content by Spectral Extinction Measurements
Suspensions of hemoglobin microparticles (HbMPs) are promising tools as oxygen therapeutics. For the approval of clinical studies extensive characterization of these HbMPs with a size of about 750 nm is required regarding physical properties, function, pharmaco-kinetics and toxicology. The standard absorbance measurements in blood gas analyzers require dissolution of red blood cells which does not work for HbMP. Therefore, we have developed a robust and rapid optical method for the quality and functionality control of HbMPs. It allows simultaneous determination of the portion of the two states of hemoglobin oxygenated hemoglobin (oxyHb) and deoxygenated hemoglobin (deoxyHb) as well as the content of methemoglobin (metHb). Based on the measurement of collimated transmission spectra between 300 nm and 800 nm, the average extinction cross section of HbMPs is derived. A numerical method is applied to determine the composition of the HbMPs based on their wavelength-dependent refractive index (RI), which is a superposition of the three different states of Hb. Thus, light-scattering properties, including extinction cross sections can be simulated for different compositions and sizes. By comparison to measured spectra, the relative concentrations of oxyHb, deoxyHb, metHb are accessible. For validation of the optically determined composition of the HbMPs, we used X-ray fluorescence spectrometry for the ratio of Fe(II) (oxyHb/deoxyHb) and Fe(III) (metHb). High accuracy density measurements served to access heme-free proteins, size was determined by dynamic light scattering and analytical centrifugation and the shape of the HbMPs was visualized by electron and atomic force microscopy.
- 10 February 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (4) , 1753
Open AccessFunction of Hemoglobin-Based Oxygen Carriers: Determination of Methemoglobin Content by Spectral Extinction Measurements
Suspensions of hemoglobin microparticles (HbMPs) are promising tools as oxygen therapeutics. For the approval of clinical studies extensive characterization of these HbMPs with a size of about 750 nm is required regarding physical properties, function, pharmaco-kinetics and toxicology. The standard absorbance measurements in blood gas analyzers require dissolution of red blood cells which does not work for HbMP. Therefore, we have developed a robust and rapid optical method for the quality and functionality control of HbMPs. It allows simultaneous determination of the portion of the two states of hemoglobin oxygenated hemoglobin (oxyHb) and deoxygenated hemoglobin (deoxyHb) as well as the content of methemoglobin (metHb). Based on the measurement of collimated transmission spectra between 300 nm and 800 nm, the average extinction cross section of HbMPs is derived. A numerical method is applied to determine the composition of the HbMPs based on their wavelength-dependent refractive index (RI), which is a superposition of the three different states of Hb. Thus, light-scattering properties, including extinction cross sections can be simulated for different compositions and sizes. By comparison to measured spectra, the relative concentrations of oxyHb, deoxyHb, metHb are accessible. For validation of the optically determined composition of the HbMPs, we used X-ray fluorescence spectrometry for the ratio of Fe(II) (oxyHb/deoxyHb) and Fe(III) (metHb). High accuracy density measurements served to access heme-free proteins, size was determined by dynamic light scattering and analytical centrifugation and the shape of the HbMPs was visualized by electron and atomic force microscopy.
- 8 August 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (9) , 4531-4550
Assessment of deformation of human red blood cells in flow cytometry: measurement and simulation of bimodal forward scatter distributions
Light scattering by single cells is widely applied for flow cytometric differentiation of cells. However, even for human red blood cells (RBCs), which can be modeled as homogeneous dielectric particles, the potential of light scattering is not yet fully exploited. We developed a dedicated flow cytometer to simultaneously observe the forward scattering cross section (FSC) of RBCs for orthogonal laser beams with incident wave vectors k → 1 and k → 2 . At a wavelength λ = 632.8 nm , bimodal distributions are observed in two-dimensional dot plots of FSC( k → 1 ) vs. FSC( k → 2 ), which result from the RBCs' random orientation around the direction of flow, as well as from the distributions of their size and their optical properties. Typically, signals of 7.5 × 10 4 RBCs were analyzed. We actively oriented the cells in the cytometer to prove that orientation is the main cause of bimodality. In addition, we studied the wavelength dependence of FSC( k → 1 ) using λ = 413.1 nm , 457.9 nm , 488 nm and 632.8 nm, covering both weak and strong light absorption by the RBCs. Simulations of the light scattering by single RBCs were performed using the discrete dipole approximation (DDA) for a range of sizes, orientations and optical properties to obtain FSC distributions from RBC ensembles. Using the axisymmetric biconcave equilibrium shape of native RBCs, the experimentally observed distributions cannot be reproduced. If, however, an elongated shape model is employed that accounts for the stretching of the cell by hydrodynamic forces in the cytometer, the features of the strongly bimodal measured frequency distributions are reproduced by the simulation. Elongation ratios significantly greater than 1 in the range of 1.5 to 2.5 yield the best agreement between experiments and simulated data.
- 8 August 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (9) , 4531-4550
Assessment of deformation of human red blood cells in flow cytometry: measurement and simulation of bimodal forward scatter distributions
Light scattering by single cells is widely applied for flow cytometric differentiation of cells. However, even for human red blood cells (RBCs), which can be modeled as homogeneous dielectric particles, the potential of light scattering is not yet fully exploited. We developed a dedicated flow cytometer to simultaneously observe the forward scattering cross section (FSC) of RBCs for orthogonal laser beams with incident wave vectors k → 1 and k → 2 . At a wavelength λ = 632.8 nm , bimodal distributions are observed in two-dimensional dot plots of FSC( k → 1 ) vs. FSC( k → 2 ), which result from the RBCs' random orientation around the direction of flow, as well as from the distributions of their size and their optical properties. Typically, signals of 7.5 × 10 4 RBCs were analyzed. We actively oriented the cells in the cytometer to prove that orientation is the main cause of bimodality. In addition, we studied the wavelength dependence of FSC( k → 1 ) using λ = 413.1 nm , 457.9 nm , 488 nm and 632.8 nm, covering both weak and strong light absorption by the RBCs. Simulations of the light scattering by single RBCs were performed using the discrete dipole approximation (DDA) for a range of sizes, orientations and optical properties to obtain FSC distributions from RBC ensembles. Using the axisymmetric biconcave equilibrium shape of native RBCs, the experimentally observed distributions cannot be reproduced. If, however, an elongated shape model is employed that accounts for the stretching of the cell by hydrodynamic forces in the cytometer, the features of the strongly bimodal measured frequency distributions are reproduced by the simulation. Elongation ratios significantly greater than 1 in the range of 1.5 to 2.5 yield the best agreement between experiments and simulated data.
- Open Access
- 15 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 4623
Refractive index of human red blood cells between 290 nm and 1100 nm determined by optical extinction measurements
The knowledge of optical properties of biological cells is essential to interpret their interaction with light and to derive morphological information and parameters associated with cell function like the oxygen transport capacity of human red blood cells (RBCs). We present a method to determine the dependence between the refractive index (RI) of human RBCs and their intracellular hemoglobin (Hb) concentration from spectral extinction measurements of a cell suspension. The procedure is based on the analysis of the corresponding ensemble averaged extinction cross section $${\bar{{\boldsymbol{C}}}}_{{\bf{e}}{\bf{x}}{\bf{t}}}(\lambda )$$ . Thus far two complementary approaches have been taken to derive RIs of RBCs. The first one uses homogeneous macroscopic samples prepared by hemolysis for the destruction of the RBCs’ membranes and subsequent centrifugation. A second approach is the determination of RIs of single intact cells by microscopic investigation. These techniques are limited to a few discrete wavelengths or a rather narrow wavelength range. In addition most of these techniques require additional information about the concentration dependence. In contrast, our approach yields the RI increment with Hb concentration of intact, reversibly isovolumetrically sphered, oxygenated RBCs over a wide wavelength range from 290 nm to 1100 nm from macroscopic measurements.- 15 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 4623
Open AccessRefractive index of human red blood cells between 290 nm and 1100 nm determined by optical extinction measurements
The knowledge of optical properties of biological cells is essential to interpret their interaction with light and to derive morphological information and parameters associated with cell function like the oxygen transport capacity of human red blood cells (RBCs). We present a method to determine the dependence between the refractive index (RI) of human RBCs and their intracellular hemoglobin (Hb) concentration from spectral extinction measurements of a cell suspension. The procedure is based on the analysis of the corresponding ensemble averaged extinction cross section $${\bar{{\boldsymbol{C}}}}_{{\bf{e}}{\bf{x}}{\bf{t}}}(\lambda )$$ . Thus far two complementary approaches have been taken to derive RIs of RBCs. The first one uses homogeneous macroscopic samples prepared by hemolysis for the destruction of the RBCs’ membranes and subsequent centrifugation. A second approach is the determination of RIs of single intact cells by microscopic investigation. These techniques are limited to a few discrete wavelengths or a rather narrow wavelength range. In addition most of these techniques require additional information about the concentration dependence. In contrast, our approach yields the RI increment with Hb concentration of intact, reversibly isovolumetrically sphered, oxygenated RBCs over a wide wavelength range from 290 nm to 1100 nm from macroscopic measurements. - 10 January 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (2) , 344-355
Extinction spectra of suspensions of microspheres: determination of the spectral refractive index and particle size distribution with nanometer accuracy
A method is presented to infer simultaneously the wavelength-dependent real refractive index (RI) of the material of microspheres and their size distribution from extinction measurements of particle suspensions. To derive the averaged spectral optical extinction cross section of the microspheres from such ensemble measurements, we determined the particle concentration by flow cytometry to an accuracy of typically 2% and adjusted the particle concentration to ensure that perturbations due to multiple scattering are negligible. For analysis of the extinction spectra, we employ Mie theory, a series-expansion representation of the refractive index and nonlinear numerical optimization. In contrast to other approaches, our method offers the advantage to simultaneously determine size, size distribution, and spectral refractive index of ensembles of microparticles including uncertainty estimation.
- 10 January 2018
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (2) , 344-355
Extinction spectra of suspensions of microspheres: determination of the spectral refractive index and particle size distribution with nanometer accuracy
A method is presented to infer simultaneously the wavelength-dependent real refractive index (RI) of the material of microspheres and their size distribution from extinction measurements of particle suspensions. To derive the averaged spectral optical extinction cross section of the microspheres from such ensemble measurements, we determined the particle concentration by flow cytometry to an accuracy of typically 2% and adjusted the particle concentration to ensure that perturbations due to multiple scattering are negligible. For analysis of the extinction spectra, we employ Mie theory, a series-expansion representation of the refractive index and nonlinear numerical optimization. In contrast to other approaches, our method offers the advantage to simultaneously determine size, size distribution, and spectral refractive index of ensembles of microparticles including uncertainty estimation.
- Open Access
Extinction spectra of suspensions of microspheres: Determination of spectral refractive index and particle size distribution with nanometer accuracy
A method is presented to infer simultaneously the wavelength-dependent real refractive index (RI) of the material of microspheres and their size distribution from extinction measurements of particle suspensions. To derive the averaged spectral optical extinction cross section of the microspheres from such ensemble measurements, we determined the particle concentration by flow cytometry to an accuracy of typically 2% and adjusted the particle concentration to ensure that perturbations due to multiple scattering are negligible. For analysis of the extinction spectra we employ Mie theory, a series-expansion representation of the refractive index and nonlinear numerical optimization. In contrast to other approaches, our method offers the advantage to simultaneously determine size, size distribution and spectral refractive index of ensembles of microparticles including uncertainty estimation.
Open AccessExtinction spectra of suspensions of microspheres: Determination of spectral refractive index and particle size distribution with nanometer accuracy
A method is presented to infer simultaneously the wavelength-dependent real refractive index (RI) of the material of microspheres and their size distribution from extinction measurements of particle suspensions. To derive the averaged spectral optical extinction cross section of the microspheres from such ensemble measurements, we determined the particle concentration by flow cytometry to an accuracy of typically 2% and adjusted the particle concentration to ensure that perturbations due to multiple scattering are negligible. For analysis of the extinction spectra we employ Mie theory, a series-expansion representation of the refractive index and nonlinear numerical optimization. In contrast to other approaches, our method offers the advantage to simultaneously determine size, size distribution and spectral refractive index of ensembles of microparticles including uncertainty estimation.
- 31 October 2016
- Published by Optica Publishing Group in Applied Optics
- Vol. 55 (31) , 8951-8961
Determining the refractive index of human hemoglobin solutions by Kramers–Kronig relations with an improved absorption model
The real part of the refractive index of aqueous solutions of human hemoglobin is computed from their absorption spectra in the wavelength range 250–1100 nm using the Kramers–Kronig (KK) relations, and the corresponding uncertainty analysis is provided. The strong ultraviolet (UV) and infrared absorbance of the water outside this spectral range were taken into account in a previous study employing KK relations. We improve these results by including the concentration dependence of the water absorbance as well as by modeling the deep UV absorbance of hemoglobin’s peptide backbone. The two free parameters of the model for the deep UV absorbance are fixed by a global fit.
- 31 October 2016
- Published by Optica Publishing Group in Applied Optics
- Vol. 55 (31) , 8951-8961
Determining the refractive index of human hemoglobin solutions by Kramers–Kronig relations with an improved absorption model
The real part of the refractive index of aqueous solutions of human hemoglobin is computed from their absorption spectra in the wavelength range 250–1100 nm using the Kramers–Kronig (KK) relations, and the corresponding uncertainty analysis is provided. The strong ultraviolet (UV) and infrared absorbance of the water outside this spectral range were taken into account in a previous study employing KK relations. We improve these results by including the concentration dependence of the water absorbance as well as by modeling the deep UV absorbance of hemoglobin’s peptide backbone. The two free parameters of the model for the deep UV absorbance are fixed by a global fit.
- 22 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 538-541
Improved result for the refractive index of human hemoglobin solutions by Kramers-Kronig relations
Applying Kramers-Kronig relations we compute the real part of the refractive index of aqueous solutions of human hemoglobin from its absorption spectra in the range 250 nm-1100 nm. Since the solution's absorption is not limited to this spectral range, strong ultraviolet (UV) and infrared absorbance of the water have been considered in previous investigations. We improve these results regarding the concentration-dependent absorption of water, the UV absorbance of hemoglobin's peptide-backbone, and by fixing the remaining unknown parameters via a global fit.
- 22 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 538-541
Improved result for the refractive index of human hemoglobin solutions by Kramers-Kronig relations
Applying Kramers-Kronig relations we compute the real part of the refractive index of aqueous solutions of human hemoglobin from its absorption spectra in the range 250 nm-1100 nm. Since the solution's absorption is not limited to this spectral range, strong ultraviolet (UV) and infrared absorbance of the water have been considered in previous investigations. We improve these results regarding the concentration-dependent absorption of water, the UV absorbance of hemoglobin's peptide-backbone, and by fixing the remaining unknown parameters via a global fit.