Foiez Ahmed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Foiez Ahmed has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Eduardo Gardenali Yukihara
Paul Scherrer Institute (PSI)
7 shared publications M.S. Akselrod
3 shared publicationsE Schnell
Department of Radiation Oncology, The University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
2 shared publicationsE. Schnell
2 shared publicationsN. Shrestha
2 shared publicationsS Ahmad
Department of Radiation Oncology, The University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
2 shared publications
Latest Publications
- 15 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (11) , 2483-2492
A Monte Carlo Model of a Benchtop X-Ray Fluorescence Computed Tomography System and Its Application to Validate a Deconvolution-Based X-Ray Fluorescence Signal Extraction Method
In this study, we developed and validated a Geant4-based Monte Carlo (MC) model of an experimental benchtop X-ray fluorescence (XRF) computed tomography (XFCT) system for quantitative imaging of metallic nanoparticles such as gold nanoparticles (GNPs) injected into small animals for preclinical testing of various NP-based diagnostic and therapeutic approaches. Detailed hardware components of the current benchtop XFCT system, including the X-ray source, excitation beam collimation and filtration, custom imaging phantoms with GNP solutions, and single/ring/linear array detectors with custom collimation, were incorporated into the MC model. In conjunction with a known CdTe detector response function, a deconvolution-based XRF signal extraction method was also developed in this study, which enabled complete separation of gold K-shell XRF peaks even when they almost overlapped and facilitated extraction of XRF signals from a broadband Compton scattered photon background. The extracted signal-to-background ratios were comparable with those expected using an ideal detector with high enough energy resolution (e.g., 0.1 keV full-width at half-maximum). Once convoluted with the CdTe detector response function, the MC-calculated spectra for excitation beams or emitted photons and XFCT image spatial resolutions agreed well with those measured experimentally. Thus, the current MC model can be used to optimize the beam/imaging parameters (e.g., beam geometry, excitation X-ray beam energy, and X-ray filter material) as well as the design of critical hardware components (e.g., detector collimators) within the current benchtop XFCT system. Also, the current XRF signal extraction method can relax the usual stringent requirement of detector energy resolution while not degrading the sensitivity of benchtop XFCT.
- 15 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (11) , 2483-2492
A Monte Carlo Model of a Benchtop X-Ray Fluorescence Computed Tomography System and Its Application to Validate a Deconvolution-Based X-Ray Fluorescence Signal Extraction Method
In this study, we developed and validated a Geant4-based Monte Carlo (MC) model of an experimental benchtop X-ray fluorescence (XRF) computed tomography (XFCT) system for quantitative imaging of metallic nanoparticles such as gold nanoparticles (GNPs) injected into small animals for preclinical testing of various NP-based diagnostic and therapeutic approaches. Detailed hardware components of the current benchtop XFCT system, including the X-ray source, excitation beam collimation and filtration, custom imaging phantoms with GNP solutions, and single/ring/linear array detectors with custom collimation, were incorporated into the MC model. In conjunction with a known CdTe detector response function, a deconvolution-based XRF signal extraction method was also developed in this study, which enabled complete separation of gold K-shell XRF peaks even when they almost overlapped and facilitated extraction of XRF signals from a broadband Compton scattered photon background. The extracted signal-to-background ratios were comparable with those expected using an ideal detector with high enough energy resolution (e.g., 0.1 keV full-width at half-maximum). Once convoluted with the CdTe detector response function, the MC-calculated spectra for excitation beams or emitted photons and XFCT image spatial resolutions agreed well with those measured experimentally. Thus, the current MC model can be used to optimize the beam/imaging parameters (e.g., beam geometry, excitation X-ray beam energy, and X-ray filter material) as well as the design of critical hardware components (e.g., detector collimators) within the current benchtop XFCT system. Also, the current XRF signal extraction method can relax the usual stringent requirement of detector energy resolution while not degrading the sensitivity of benchtop XFCT.
- Open Access
- 22 December 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-13
Radiosensitization of Prostate Cancers In Vitro and In Vivo to Erbium-filtered Orthovoltage X-rays Using Actively Targeted Gold Nanoparticles
Theoretical investigations suggest that gold nanoparticle (GNP)-mediated radiation dose enhancement and radiosensitization can be maximized when photons interact with gold, predominantly via photoelectric absorption. This makes ytterbium (Yb)-169, which emits photons with an average energy of 93 keV (just above the K-edge of gold), an ideal radioisotope for such purposes. This investigation tests the feasibility of tumor-specific prostate brachytherapy achievable with Yb-169 and actively targeted GNPs, using an external beam surrogate of Yb-169 created from an exotic filter material - erbium (Er) and a standard copper-filtered 250 kVp beam. The current in vitro study shows that treatment of prostate cancer cells with goserelin-conjugated gold nanorods (gGNRs) promotes gonadotropin releasing hormone receptor-mediated internalization and enhances radiosensitivity to both Er-filtered and standard 250 kVp beams, 14 and 10%, respectively. While the degree of GNP-mediated radiosensitization as seen from the in vitro study may be considered moderate, the current in vivo study shows that gGNR treatment plus Er-filtered x-ray irradiation is considerably more effective than radiation treatment alone (p < 0.0005), resulting in a striking reduction in tumor volume (50% smaller) 2 months following treatment. Overall, the current results provide strong evidence for the feasibility of tumor-specific prostate brachytherapy with Yb-169 and gGNRs.
- 22 December 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-13
Open AccessRadiosensitization of Prostate Cancers In Vitro and In Vivo to Erbium-filtered Orthovoltage X-rays Using Actively Targeted Gold Nanoparticles
Theoretical investigations suggest that gold nanoparticle (GNP)-mediated radiation dose enhancement and radiosensitization can be maximized when photons interact with gold, predominantly via photoelectric absorption. This makes ytterbium (Yb)-169, which emits photons with an average energy of 93 keV (just above the K-edge of gold), an ideal radioisotope for such purposes. This investigation tests the feasibility of tumor-specific prostate brachytherapy achievable with Yb-169 and actively targeted GNPs, using an external beam surrogate of Yb-169 created from an exotic filter material - erbium (Er) and a standard copper-filtered 250 kVp beam. The current in vitro study shows that treatment of prostate cancer cells with goserelin-conjugated gold nanorods (gGNRs) promotes gonadotropin releasing hormone receptor-mediated internalization and enhances radiosensitivity to both Er-filtered and standard 250 kVp beams, 14 and 10%, respectively. While the degree of GNP-mediated radiosensitization as seen from the in vitro study may be considered moderate, the current in vivo study shows that gGNR treatment plus Er-filtered x-ray irradiation is considerably more effective than radiation treatment alone (p < 0.0005), resulting in a striking reduction in tumor volume (50% smaller) 2 months following treatment. Overall, the current results provide strong evidence for the feasibility of tumor-specific prostate brachytherapy with Yb-169 and gGNRs.
- 1 November 2017
- Published by Elsevier in Radiation Measurements
- Vol. 106, 315-320
Demonstration of 2D dosimetry using Al 2 O 3 optically stimulated luminescence films for therapeutic megavoltage x-ray and ion beams
- 1 November 2017
- Published by Elsevier in Radiation Measurements
- Vol. 106, 315-320
Demonstration of 2D dosimetry using Al 2 O 3 optically stimulated luminescence films for therapeutic megavoltage x-ray and ion beams
- 1 November 2017
- Published by Elsevier in Radiation Measurements
- Vol. 106, 346-351
Feasibility of dosimetry with optically stimulated luminescence detectors in magnetic fields
- 1 November 2017
- Published by Elsevier in Radiation Measurements
- Vol. 106, 346-351
Feasibility of dosimetry with optically stimulated luminescence detectors in magnetic fields
- 7 October 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (21) , 7551-7570
Characterization of Al2O3optically stimulated luminescence films for 2D dosimetry using a 6 MV photon beam
This work evaluates the dosimetric properties of newly developed optically stimulated luminescence (OSL) films, fabricated with either Al 2 O 3 :C or Al 2 O 3 :C,Mg, using a prototype laser scanning reader, a developed image reconstruction algorithm, and a 6 MV therapeutic photon beam. Packages containing OSL films (Al 2 O 3 :C and Al 2 O 3 :C,Mg) and a radiochromic film (Gafchromic EBT3) were irradiated using a 6 MV photon beam using different doses, field sizes, with and without wedge filter. Dependence on film orientation of the OSL system was also tested. Diode-array (MapCHECK) and ionization chamber measurements were performed for comparison. The OSLD film doses agreed with the MapCHECK and ionization chamber data within the experimental uncertainties (2 O 3 :C or Al 2 O 3 :C,Mg.
- 7 October 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (21) , 7551-7570
Characterization of Al2O3optically stimulated luminescence films for 2D dosimetry using a 6 MV photon beam
This work evaluates the dosimetric properties of newly developed optically stimulated luminescence (OSL) films, fabricated with either Al 2 O 3 :C or Al 2 O 3 :C,Mg, using a prototype laser scanning reader, a developed image reconstruction algorithm, and a 6 MV therapeutic photon beam. Packages containing OSL films (Al 2 O 3 :C and Al 2 O 3 :C,Mg) and a radiochromic film (Gafchromic EBT3) were irradiated using a 6 MV photon beam using different doses, field sizes, with and without wedge filter. Dependence on film orientation of the OSL system was also tested. Diode-array (MapCHECK) and ionization chamber measurements were performed for comparison. The OSLD film doses agreed with the MapCHECK and ionization chamber data within the experimental uncertainties (2 O 3 :C or Al 2 O 3 :C,Mg.
- 3 October 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (20) , 7484-7506
Image reconstruction algorithm for optically stimulated luminescence 2D dosimetry using laser-scanned Al2O3:C and Al2O3:C,Mg films
The objective of this work was to develop an image reconstruction algorithm for 2D dosimetry using Al 2 O 3 :C and Al 2 O 3 :C,Mg optically stimulated luminescence (OSL) films imaged using a laser scanning system. The algorithm takes into account parameters associated with detector properties and the readout system. Pieces of Al 2 O 3 :C films (~8 mm × 8 mm × 125 µ m) were irradiated and used to simulate dose distributions with extreme dose gradients (zero and non-zero dose regions). The OSLD film pieces were scanned using a custom-built laser-scanning OSL reader and the data obtained were used to develop and demonstrate a dose reconstruction algorithm. The algorithm includes corrections for: (a) galvo hysteresis, (b) photomultiplier tube (PMT) linearity, (c) phosphorescence, (d) ‘pixel bleeding’ caused by the 35 ms luminescence lifetime of F-centers in Al 2 O 3 , (e) geometrical distortion inherent to Galvo scanning system, and (f) position dependence of the light collection efficiency. The algorithm was also applied to 6.0 cm × 6.0 cm × 125 μm or 10.0 cm × 10.0 cm × 125 µ m Al 2 O 3 :C and Al 2 O 3 :C,Mg films exposed to megavoltage x-rays (6 MV) and 12 C beams (430 MeV u −1 ). The results obtained using pieces of irradiated films show the ability of the image reconstruction algorithm to correct for pixel bleeding even in the presence of extremely sharp dose gradients. Corrections for geometric distortion and position dependence of light collection efficiency were shown to minimize characteristic limitations of this system design. We also exemplify the application of the algorithm to more clinically relevant 6 MV x-ray beam and a 12 C pencil beam, demonstrating the potential for small field dosimetry. The image reconstruction algorithm described here provides the foundation for laser-scanned OSL applied to 2D dosimetry.
- 3 October 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (20) , 7484-7506
Image reconstruction algorithm for optically stimulated luminescence 2D dosimetry using laser-scanned Al2O3:C and Al2O3:C,Mg films
The objective of this work was to develop an image reconstruction algorithm for 2D dosimetry using Al 2 O 3 :C and Al 2 O 3 :C,Mg optically stimulated luminescence (OSL) films imaged using a laser scanning system. The algorithm takes into account parameters associated with detector properties and the readout system. Pieces of Al 2 O 3 :C films (~8 mm × 8 mm × 125 µ m) were irradiated and used to simulate dose distributions with extreme dose gradients (zero and non-zero dose regions). The OSLD film pieces were scanned using a custom-built laser-scanning OSL reader and the data obtained were used to develop and demonstrate a dose reconstruction algorithm. The algorithm includes corrections for: (a) galvo hysteresis, (b) photomultiplier tube (PMT) linearity, (c) phosphorescence, (d) ‘pixel bleeding’ caused by the 35 ms luminescence lifetime of F-centers in Al 2 O 3 , (e) geometrical distortion inherent to Galvo scanning system, and (f) position dependence of the light collection efficiency. The algorithm was also applied to 6.0 cm × 6.0 cm × 125 μm or 10.0 cm × 10.0 cm × 125 µ m Al 2 O 3 :C and Al 2 O 3 :C,Mg films exposed to megavoltage x-rays (6 MV) and 12 C beams (430 MeV u −1 ). The results obtained using pieces of irradiated films show the ability of the image reconstruction algorithm to correct for pixel bleeding even in the presence of extremely sharp dose gradients. Corrections for geometric distortion and position dependence of light collection efficiency were shown to minimize characteristic limitations of this system design. We also exemplify the application of the algorithm to more clinically relevant 6 MV x-ray beam and a 12 C pencil beam, demonstrating the potential for small field dosimetry. The image reconstruction algorithm described here provides the foundation for laser-scanned OSL applied to 2D dosimetry.
- 9 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 34 (12) , 2506-2517
Pixel Bleeding Correction in Laser Scanning Luminescence Imaging Demonstrated Using Optically Stimulated Luminescence
This paper describes and investigates the performance of an algorithm to correct for “pixel bleeding” caused by slow luminescence centers in laser scanning imaging (e.g., X-ray imaging using photostimulable phosphors and 2D dosimetry using optically stimulated luminescence). The algorithm is based on a deconvolution procedure that takes into account the lifetime of the slow luminescence center and is further constrained by the detection of fast and slow luminescence centers and combining rows scanned in opposite directions. The algorithm was tested using simulated data and demonstrated experimentally by applying it to image reconstruction of two types of Al 2 O 3 X-ray detector films (Al 2 O 3 :C and Al 2 O 3 :C,Mg), whose use in 2D dosimetry in conjunction with laser-scanning readout has so far been prevented by slow luminescence centers (F-centers, 35 ms lifetime). We show that the algorithm allows the readout of Al 2 O 3 film detectors 300-500 times faster than generally allowed considering the lifetime of the main luminescence centers. By relaxing the stringent requirements on the detector's luminescence lifetime, the algorithm opens the possibility of using new materials in 2D dosimetry as well as other laser scanning applications, such as X-ray imaging using storage phosphors and scanning confocal microscopy, although the effect of the noise introduced must be investigated for each specific application.
- 9 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 34 (12) , 2506-2517
Pixel Bleeding Correction in Laser Scanning Luminescence Imaging Demonstrated Using Optically Stimulated Luminescence
This paper describes and investigates the performance of an algorithm to correct for “pixel bleeding” caused by slow luminescence centers in laser scanning imaging (e.g., X-ray imaging using photostimulable phosphors and 2D dosimetry using optically stimulated luminescence). The algorithm is based on a deconvolution procedure that takes into account the lifetime of the slow luminescence center and is further constrained by the detection of fast and slow luminescence centers and combining rows scanned in opposite directions. The algorithm was tested using simulated data and demonstrated experimentally by applying it to image reconstruction of two types of Al 2 O 3 X-ray detector films (Al 2 O 3 :C and Al 2 O 3 :C,Mg), whose use in 2D dosimetry in conjunction with laser-scanning readout has so far been prevented by slow luminescence centers (F-centers, 35 ms lifetime). We show that the algorithm allows the readout of Al 2 O 3 film detectors 300-500 times faster than generally allowed considering the lifetime of the main luminescence centers. By relaxing the stringent requirements on the detector's luminescence lifetime, the algorithm opens the possibility of using new materials in 2D dosimetry as well as other laser scanning applications, such as X-ray imaging using storage phosphors and scanning confocal microscopy, although the effect of the noise introduced must be investigated for each specific application.
- 1 December 2014
- Published by Elsevier in Radiation Measurements
- Vol. 71, 187-192
Development of a 2D dosimetry system based on the optically stimulated luminescence of Al2O3
- 1 December 2014
- Published by Elsevier in Radiation Measurements
- Vol. 71, 187-192
Development of a 2D dosimetry system based on the optically stimulated luminescence of Al2O3
- 1 September 2013
- Published by Elsevier in Radiation Measurements
- Vol. 56, 179-182
Radiophotoluminescence properties of Al2O3:C,Mg crystals
- 1 September 2013
- Published by Elsevier in Radiation Measurements
- Vol. 56, 179-182
Radiophotoluminescence properties of Al2O3:C,Mg crystals