A Monte Carlo Model of a Benchtop X-Ray Fluorescence Computed Tomography System and Its Application to Validate a Deconvolution-Based X-Ray Fluorescence Signal Extraction Method
- 15 May 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (11) , 2483-2492
Abstract
In this study, we developed and validated a Geant4-based Monte Carlo (MC) model of an experimental benchtop X-ray fluorescence (XRF) computed tomography (XFCT) system for quantitative imaging of metallic nanoparticles such as gold nanoparticles (GNPs) injected into small animals for preclinical testing of various NP-based diagnostic and therapeutic approaches. Detailed hardware components of the current benchtop XFCT system, including the X-ray source, excitation beam collimation and filtration, custom imaging phantoms with GNP solutions, and single/ring/linear array detectors with custom collimation, were incorporated into the MC model. In conjunction with a known CdTe detector response function, a deconvolution-based XRF signal extraction method was also developed in this study, which enabled complete separation of gold K-shell XRF peaks even when they almost overlapped and facilitated extraction of XRF signals from a broadband Compton scattered photon background. The extracted signal-to-background ratios were comparable with those expected using an ideal detector with high enough energy resolution (e.g., 0.1 keV full-width at half-maximum). Once convoluted with the CdTe detector response function, the MC-calculated spectra for excitation beams or emitted photons and XFCT image spatial resolutions agreed well with those measured experimentally. Thus, the current MC model can be used to optimize the beam/imaging parameters (e.g., beam geometry, excitation X-ray beam energy, and X-ray filter material) as well as the design of critical hardware components (e.g., detector collimators) within the current benchtop XFCT system. Also, the current XRF signal extraction method can relax the usual stringent requirement of detector energy resolution while not degrading the sensitivity of benchtop XFCT.Keywords
Funding Information
- National Institutes of Health (R01CA155446, R01EB020658)
This publication has 32 references indexed in Scilit:
- Elemental and Chemically Specific X-ray Fluorescence Imaging of Biological SystemsChemical Reviews, 2014
- Experimental demonstration of benchtop x-ray fluorescence computed tomography (XFCT) of gold nanoparticle-loaded objects using lead- and tin-filtered polychromatic cone-beamsPhysics in Medicine & Biology, 2012
- The feasibility of polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects: a Monte Carlo studyPhysics in Medicine & Biology, 2011
- The dosimetric feasibility of gold nanoparticle-aided radiation therapy (GNRT) via brachytherapy using low-energy gamma-/x-ray sourcesPhysics in Medicine & Biology, 2009
- Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical ApplicationsSensors, 2009
- Estimation of tumour dose enhancement due to gold nanoparticles during typical radiation treatments: a preliminary Monte Carlo studyPhysics in Medicine & Biology, 2005
- Reconstructing x-ray fluorescence microtomogramsApplied Physics Letters, 2001
- X-ray fluorescent computer tomography with synchrotron radiationIEEE Transactions on Nuclear Science, 1998
- A general Monte Carlo simulation of energy-dispersive X-ray fluorescence spectrometers—ISpectrochimica Acta Part B: Atomic Spectroscopy, 1993
- Trace element analysis in biological samples by using XRF spectrometry with secondary radiationPhysics in Medicine & Biology, 1983