Mohamed Hassan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohamed Hassan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Brahim Benmokrane
4 shared publicationsEhab A. Ahmed
Postdoctoral Fellow, Dept. of Civil Engineering, Univ. of Sherbrooke, Sherbrooke, QC, Canada J1K 2R1; and Lecturer, Dept. of Civil Engineering, Menoufiua Univ., Shebin El-Kom, Egypt
3 shared publications- Brahim Benmokrane
University of Sherbrooke
2 shared publications Adel ElSafty
1 shared publication- Ahmed Gouda
Department of Civil Engineering, Faculty of Engineering, Helwan University (HU), Cairo 11795, Egypt
1 shared publication - Allan Manalo
University of Southern Queensland
1 shared publication
Latest Publications
- Open Access
Investigation of Key Parameters Influencing Shear Behavior in Glass-Fiber-Reinforced Polymer (GFRP)-Reinforced Concrete (RC) Interior Slab–Column Connections
This article explores the punching shear behavior of GFRP-RC interior slab–column connections. The parameters tested included the column–aspect ratio (1.0, 2.0, 3.0, 4.0, and 5.0), perimeter-to-depth ratio for square column stubs with side lengths of 0.3, 0.4, 0.5, 0.6, and 0.7 m, and span-to-depth ratios of 4, 6, 8, 10, and 12. A review of the literature revealed that no previous study has investigated the effect of these parameters or their interactions on this type of connection. Numerically, twenty-five slabs were created using finite element (FE) software (V3), each with square dimensions of 2.5 m and a constant thickness of 0.2 m. The central column extended 0.3 m from the top and bottom of the slab. All four sides of the slabs were supported, and the specimens underwent pure static shear load testing. The test results demonstrated that all slabs failed due to punching shear. Increasing any parameter value reduced the punching shear stresses. Additionally, the results indicated that Canadian (CSA-S806-12) and Japanese (JSCE-97) standards for FRP-RC materials generally provided the closest predictions of punching shear capacity compared to the American guideline, ACI 440.1R-22. However, all standards exhibited shortcomings and require enhancement and modifications, particularly to consider the impact of the span-to-depth ratio. Therefore, three equations were developed to predict the shear strength of the connections, yielding better results than those prescribed by the North American and Japanese standards.
Open AccessInvestigation of Key Parameters Influencing Shear Behavior in Glass-Fiber-Reinforced Polymer (GFRP)-Reinforced Concrete (RC) Interior Slab–Column Connections
This article explores the punching shear behavior of GFRP-RC interior slab–column connections. The parameters tested included the column–aspect ratio (1.0, 2.0, 3.0, 4.0, and 5.0), perimeter-to-depth ratio for square column stubs with side lengths of 0.3, 0.4, 0.5, 0.6, and 0.7 m, and span-to-depth ratios of 4, 6, 8, 10, and 12. A review of the literature revealed that no previous study has investigated the effect of these parameters or their interactions on this type of connection. Numerically, twenty-five slabs were created using finite element (FE) software (V3), each with square dimensions of 2.5 m and a constant thickness of 0.2 m. The central column extended 0.3 m from the top and bottom of the slab. All four sides of the slabs were supported, and the specimens underwent pure static shear load testing. The test results demonstrated that all slabs failed due to punching shear. Increasing any parameter value reduced the punching shear stresses. Additionally, the results indicated that Canadian (CSA-S806-12) and Japanese (JSCE-97) standards for FRP-RC materials generally provided the closest predictions of punching shear capacity compared to the American guideline, ACI 440.1R-22. However, all standards exhibited shortcomings and require enhancement and modifications, particularly to consider the impact of the span-to-depth ratio. Therefore, three equations were developed to predict the shear strength of the connections, yielding better results than those prescribed by the North American and Japanese standards.
- 27 September 2022
- Published by Springer Nature
- p. 205-212
Gravity Load Effect on Punching Behavior of GFRP-RC Interior Slab-Column Connection Subjected to Lateral Cyclic Load
- 27 September 2022
- Published by Springer Nature
- p. 205-212
Gravity Load Effect on Punching Behavior of GFRP-RC Interior Slab-Column Connection Subjected to Lateral Cyclic Load
- 1 October 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 24 (5) , 04020058
Flexural Performance of Unbonded Posttensioned Rectangular Concrete Filled FRP Tube Beams
This paper experimentally investigates the effect of using the posttensioning (PT) steel strands on the flexural performance of rectangular concrete filled fiber-reinforced polymer (FRP) tube (CFFT) beams. Eight PT beams were tested to failure in four-point bending. The main parameters are the effect of prestressed reinforcement, the glass fiber-reinforced polymer (GFRP) tube, the tube thickness, the magnitude of the prestress level, and the number of strands. The test results indicate that rectangular PT CFFT beams showed superior load–deflection behaviors and higher flexural strength compared with the non-PT CFFT designed with identical structural laminate and tube thickness. The results show that PT CFFT beams performed substantially better than PT concrete beams with the same cross-sectional dimensions and prestressing. The flexural behavior of the tested PT CFFT beams is highly dependent on the FRP tube confinement and thickness and, to a lesser extent, on the magnitude of the prestress level and the number of strands. A strain compatibility model has been developed considering the partially confined and unconfined concrete models and verified against the experimental results. The proposed model successfully predicts the flexural moment capacity of the tested beams with satisfactory accuracy on average of 1.05 ± 0.03 and 1.21 ± 0.04, respectively. In addition, it was found that neglecting concrete confinement highly underestimates the flexural strength. More investigations, however, are needed to assess the effect of a wide range of key influencing parameters to better model and understand the flexural behavior of rectangular PT CFFT beams.
- 1 October 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 24 (5) , 04020058
Flexural Performance of Unbonded Posttensioned Rectangular Concrete Filled FRP Tube Beams
This paper experimentally investigates the effect of using the posttensioning (PT) steel strands on the flexural performance of rectangular concrete filled fiber-reinforced polymer (FRP) tube (CFFT) beams. Eight PT beams were tested to failure in four-point bending. The main parameters are the effect of prestressed reinforcement, the glass fiber-reinforced polymer (GFRP) tube, the tube thickness, the magnitude of the prestress level, and the number of strands. The test results indicate that rectangular PT CFFT beams showed superior load–deflection behaviors and higher flexural strength compared with the non-PT CFFT designed with identical structural laminate and tube thickness. The results show that PT CFFT beams performed substantially better than PT concrete beams with the same cross-sectional dimensions and prestressing. The flexural behavior of the tested PT CFFT beams is highly dependent on the FRP tube confinement and thickness and, to a lesser extent, on the magnitude of the prestress level and the number of strands. A strain compatibility model has been developed considering the partially confined and unconfined concrete models and verified against the experimental results. The proposed model successfully predicts the flexural moment capacity of the tested beams with satisfactory accuracy on average of 1.05 ± 0.03 and 1.21 ± 0.04, respectively. In addition, it was found that neglecting concrete confinement highly underestimates the flexural strength. More investigations, however, are needed to assess the effect of a wide range of key influencing parameters to better model and understand the flexural behavior of rectangular PT CFFT beams.
- 1 June 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 24 (3)
Effect of Different Constituent Fiber, Resin, and Sizing Combinations on Alkaline Resistance of Basalt, Carbon, and Glass FRP Bars
When used as an internal reinforcement, fiber-reinforced-polymer (FRP) composite bars are exposed to a highly alkaline (pH > 12.5) concrete environment. This study evaluated the durability of 24 types of FRP bars in a simulated alkaline concrete environment, specifically with respect to reinforcing-fiber type (carbon, basalt, and glass), fiber sizing, resin chemistry, and manufacturer. A total of 10 types of glass fibers, including two types of E-glass fibers and eight types of electrical corrosion resistance (ECR)-glass fibers, four types of basalt fibers, two types of carbon fibers, six types of resin systems based on vinyl ester, polyurethane, and epoxy resins, and five types of proprietary fiber sizings were used in manufacturing the bars. The study focused on assessing the tensile, transverse-shear, and interlaminar-shear properties of FRP bars subjected to 3 months of accelerated alkaline conditioning at 60°C, as per Canadian Standards Association (CSA) and American Society for Testing and Materials (ASTM) standards. The strength retention and failure of these bars were evaluated as a measurement of the durability and long-term performance of the FRP bars currently available on the market and for quality control by manufacturers. Statistical analysis using independent samples t-test and one-way analysis of variance revealed that the manufacturing parameters have a significant effect on the mechanical characteristics and alkaline resistance of FRP bars. In particular, the results show that the FRP bars manufactured with the same parameters and fiber types but by different fiber manufacturers with different fiber sizings and resin systems produced bars with totally different strength properties and durability performance in an alkaline environment. Vinyl ester resin and silane-sized fiber was the most compatible resin system and produced a more durable glass-FRP bar, while the epoxy resin yielded more durable basalt- and carbon-FRP bars. This paper also describes a procedure for and a criterion of the optimum manufacturing parameters to achieve specific mechanical properties and durability performance with FRP bars.
- 1 June 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 24 (3)
Effect of Different Constituent Fiber, Resin, and Sizing Combinations on Alkaline Resistance of Basalt, Carbon, and Glass FRP Bars
When used as an internal reinforcement, fiber-reinforced-polymer (FRP) composite bars are exposed to a highly alkaline (pH > 12.5) concrete environment. This study evaluated the durability of 24 types of FRP bars in a simulated alkaline concrete environment, specifically with respect to reinforcing-fiber type (carbon, basalt, and glass), fiber sizing, resin chemistry, and manufacturer. A total of 10 types of glass fibers, including two types of E-glass fibers and eight types of electrical corrosion resistance (ECR)-glass fibers, four types of basalt fibers, two types of carbon fibers, six types of resin systems based on vinyl ester, polyurethane, and epoxy resins, and five types of proprietary fiber sizings were used in manufacturing the bars. The study focused on assessing the tensile, transverse-shear, and interlaminar-shear properties of FRP bars subjected to 3 months of accelerated alkaline conditioning at 60°C, as per Canadian Standards Association (CSA) and American Society for Testing and Materials (ASTM) standards. The strength retention and failure of these bars were evaluated as a measurement of the durability and long-term performance of the FRP bars currently available on the market and for quality control by manufacturers. Statistical analysis using independent samples t-test and one-way analysis of variance revealed that the manufacturing parameters have a significant effect on the mechanical characteristics and alkaline resistance of FRP bars. In particular, the results show that the FRP bars manufactured with the same parameters and fiber types but by different fiber manufacturers with different fiber sizings and resin systems produced bars with totally different strength properties and durability performance in an alkaline environment. Vinyl ester resin and silane-sized fiber was the most compatible resin system and produced a more durable glass-FRP bar, while the epoxy resin yielded more durable basalt- and carbon-FRP bars. This paper also describes a procedure for and a criterion of the optimum manufacturing parameters to achieve specific mechanical properties and durability performance with FRP bars.
- 1 December 2016
- Published by Elsevier in Composites Part B: Engineering
- Vol. 106, 262-272
Bond durability of basalt-fiber-reinforced-polymer (BFRP) bars embedded in concrete in aggressive environments
- 1 December 2016
- Published by Elsevier in Composites Part B: Engineering
- Vol. 106, 262-272
Bond durability of basalt-fiber-reinforced-polymer (BFRP) bars embedded in concrete in aggressive environments
- 1 February 2015
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 19 (1)
Punching Shear Behavior of Two-Way Slabs Reinforced with FRP Shear Reinforcement
- 1 February 2015
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 19 (1)
Punching Shear Behavior of Two-Way Slabs Reinforced with FRP Shear Reinforcement
- 1 September 2014
- Published by Elsevier in Construction and Building Materials
- Vol. 66, 522-532
Punching-shear design equation for two-way concrete slabs reinforced with FRP bars and stirrups
- 1 September 2014
- Published by Elsevier in Construction and Building Materials
- Vol. 66, 522-532
Punching-shear design equation for two-way concrete slabs reinforced with FRP bars and stirrups
- 1 December 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 17 (6)
Punching-Shear Strength of Normal and High-Strength Two-Way Concrete Slabs Reinforced with GFRP Bars
This paper investigated the punching-shear behavior of two-way concrete slabs reinforced with glass fiber–reinforced polymer (GFRP) bars of different grades. A total of 10 full-scale interior slab-column specimens measuring 2,500×2,500 mm with thicknesses of either 200 or 350 mm and 300×300 mm square column stubs were fabricated with normal and high-strength concretes. The specimens were tested under monotonic concentric loading until failure. The effects of concrete strength as well as reinforcement type and ratio were evaluated. The test results revealed that increasing the reinforcement ratio resulted in higher punching-shear capacity, lower reinforcement and concrete strains, and lower deflections. In addition, the high-strength concrete increased the punching-shear capacity, significantly reduced concrete strains, increased strains in the GFRP reinforcing bars, and reduced deflection due to the high tensile strength and modulus of elasticity. The test results and results from literature wer...
- 1 December 2013
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 17 (6)
Punching-Shear Strength of Normal and High-Strength Two-Way Concrete Slabs Reinforced with GFRP Bars
This paper investigated the punching-shear behavior of two-way concrete slabs reinforced with glass fiber–reinforced polymer (GFRP) bars of different grades. A total of 10 full-scale interior slab-column specimens measuring 2,500×2,500 mm with thicknesses of either 200 or 350 mm and 300×300 mm square column stubs were fabricated with normal and high-strength concretes. The specimens were tested under monotonic concentric loading until failure. The effects of concrete strength as well as reinforcement type and ratio were evaluated. The test results revealed that increasing the reinforcement ratio resulted in higher punching-shear capacity, lower reinforcement and concrete strains, and lower deflections. In addition, the high-strength concrete increased the punching-shear capacity, significantly reduced concrete strains, increased strains in the GFRP reinforcing bars, and reduced deflection due to the high tensile strength and modulus of elasticity. The test results and results from literature wer...
- 1 October 2013
- Published by Canadian Science Publishing in Canadian Journal of Civil Engineering
- Vol. 40 (10) , 951-960
Punching shear strength of glass fiber-reinforced polymer reinforced concrete flat slabs
- 1 October 2013
- Published by Canadian Science Publishing in Canadian Journal of Civil Engineering
- Vol. 40 (10) , 951-960
Punching shear strength of glass fiber-reinforced polymer reinforced concrete flat slabs