Ahmed Gouda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ahmed Gouda has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Loai Alkhattabi
Department of Civil and Environmental Engineering, College of Engineering, University of Jeddah, Jeddah 23890, Saudi Arabia
1 shared publication - Mohamed Hassan
Department of Civil Engineering, Faculty of Engineering, Helwan University (HU), Cairo 11795, Egypt
1 shared publication - Nehal M. Ayash
Helwan University
1 shared publication
Latest Publications
- Open Access
Investigation of Key Parameters Influencing Shear Behavior in Glass-Fiber-Reinforced Polymer (GFRP)-Reinforced Concrete (RC) Interior Slab–Column Connections
This article explores the punching shear behavior of GFRP-RC interior slab–column connections. The parameters tested included the column–aspect ratio (1.0, 2.0, 3.0, 4.0, and 5.0), perimeter-to-depth ratio for square column stubs with side lengths of 0.3, 0.4, 0.5, 0.6, and 0.7 m, and span-to-depth ratios of 4, 6, 8, 10, and 12. A review of the literature revealed that no previous study has investigated the effect of these parameters or their interactions on this type of connection. Numerically, twenty-five slabs were created using finite element (FE) software (V3), each with square dimensions of 2.5 m and a constant thickness of 0.2 m. The central column extended 0.3 m from the top and bottom of the slab. All four sides of the slabs were supported, and the specimens underwent pure static shear load testing. The test results demonstrated that all slabs failed due to punching shear. Increasing any parameter value reduced the punching shear stresses. Additionally, the results indicated that Canadian (CSA-S806-12) and Japanese (JSCE-97) standards for FRP-RC materials generally provided the closest predictions of punching shear capacity compared to the American guideline, ACI 440.1R-22. However, all standards exhibited shortcomings and require enhancement and modifications, particularly to consider the impact of the span-to-depth ratio. Therefore, three equations were developed to predict the shear strength of the connections, yielding better results than those prescribed by the North American and Japanese standards.
Open AccessInvestigation of Key Parameters Influencing Shear Behavior in Glass-Fiber-Reinforced Polymer (GFRP)-Reinforced Concrete (RC) Interior Slab–Column Connections
This article explores the punching shear behavior of GFRP-RC interior slab–column connections. The parameters tested included the column–aspect ratio (1.0, 2.0, 3.0, 4.0, and 5.0), perimeter-to-depth ratio for square column stubs with side lengths of 0.3, 0.4, 0.5, 0.6, and 0.7 m, and span-to-depth ratios of 4, 6, 8, 10, and 12. A review of the literature revealed that no previous study has investigated the effect of these parameters or their interactions on this type of connection. Numerically, twenty-five slabs were created using finite element (FE) software (V3), each with square dimensions of 2.5 m and a constant thickness of 0.2 m. The central column extended 0.3 m from the top and bottom of the slab. All four sides of the slabs were supported, and the specimens underwent pure static shear load testing. The test results demonstrated that all slabs failed due to punching shear. Increasing any parameter value reduced the punching shear stresses. Additionally, the results indicated that Canadian (CSA-S806-12) and Japanese (JSCE-97) standards for FRP-RC materials generally provided the closest predictions of punching shear capacity compared to the American guideline, ACI 440.1R-22. However, all standards exhibited shortcomings and require enhancement and modifications, particularly to consider the impact of the span-to-depth ratio. Therefore, three equations were developed to predict the shear strength of the connections, yielding better results than those prescribed by the North American and Japanese standards.