Fernando J. Quevedo Gonzalez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fernando J. Quevedo Gonzalez has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
Timothy M. Wright
Department of Biomechanics, Hospital for Special Surgery, New York
13 shared publicationsJoseph D. Lipman
Department of Biomechanics, Hospital for Special Surgery, New York
11 shared publicationsPeter K. Sculco
Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York
9 shared publicationsDavid J. Mayman
Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York, USA
7 shared publicationsJonathan M. Vigdorchik
Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York
6 shared publicationsCynthia A. Kahlenberg
Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York
5 shared publications
Latest Publications
- 17 August 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (8)
Fractures Around Collared and Collarless Hip Stems Initiate in High Strain Regions: A Combined Cadaveric Experiment and Finite Element Analysis
Periprosthetic femoral fracture (PFF) is a common early complication after primary total hip arthroplasty. Collared stems reduce but do not eliminate the incidence of PFF, and exhibit variable biomechanical effectiveness, emphasizing our limited understanding of the local bone–implant interaction mechanics. Our goal was to elucidate the relationship between the local strains at the bone–implant interface and the experimental fracture patterns and loads for collared and collarless stems. Six pairs of women cadaveric femurs implanted with a collarless or collared stem were loaded to failure under simulated stumbling to determine the location of PFF and the load to fracture, which we related to the collar‐calcar separation. Corresponding specimen‐specific FE models were developed to determine the strain at the bone‐implant interface and to predict the fracture onset load and location of fracture, which we related to the experimental location of PFF and the load‐to‐fracture. Load to fracture was greater for collared stems and was inversely correlated with the collar‐calcar separation at the time of implantation ( r = −0.80, p = 0.055). Fractures occurred in areas of high strain. The experimental fracture location coincided with the first yielding cortical element in five cases. The load at which the first cortical element yielded (i.e., onset of fracture was moderately correlated with the experimental fracture load ( R 2 = 0.43, RMSE = 1231 N). Our results emphasize the importance of initial calcar contact to realize the benefits of the collar. Localized load transfer was a precursor of macroscopic fracture, which initiated in areas of high tensile strain.
- 17 August 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (8)
Fractures Around Collared and Collarless Hip Stems Initiate in High Strain Regions: A Combined Cadaveric Experiment and Finite Element Analysis
Periprosthetic femoral fracture (PFF) is a common early complication after primary total hip arthroplasty. Collared stems reduce but do not eliminate the incidence of PFF, and exhibit variable biomechanical effectiveness, emphasizing our limited understanding of the local bone–implant interaction mechanics. Our goal was to elucidate the relationship between the local strains at the bone–implant interface and the experimental fracture patterns and loads for collared and collarless stems. Six pairs of women cadaveric femurs implanted with a collarless or collared stem were loaded to failure under simulated stumbling to determine the location of PFF and the load to fracture, which we related to the collar‐calcar separation. Corresponding specimen‐specific FE models were developed to determine the strain at the bone‐implant interface and to predict the fracture onset load and location of fracture, which we related to the experimental location of PFF and the load‐to‐fracture. Load to fracture was greater for collared stems and was inversely correlated with the collar‐calcar separation at the time of implantation ( r = −0.80, p = 0.055). Fractures occurred in areas of high strain. The experimental fracture location coincided with the first yielding cortical element in five cases. The load at which the first cortical element yielded (i.e., onset of fracture was moderately correlated with the experimental fracture load ( R 2 = 0.43, RMSE = 1231 N). Our results emphasize the importance of initial calcar contact to realize the benefits of the collar. Localized load transfer was a precursor of macroscopic fracture, which initiated in areas of high tensile strain.
- 1 July 2026
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 108-B (7) , 906-912
Lower septic revision rates following cementless compared with cemented robotic-assisted total knee arthroplasty using a single implant design
Aims: The choice of fixation for total knee arthroplasty (TKA) remains controversial. Cementless designs incorporating highly porous titanium surfaces may achieve durable biological fixation and mitigate cement-related complications. However, little has been written comparing the methods of fixation for robotic-assisted (RA) TKA. The aim of this study was to compare the implant survival and complication rates between cemented and cementless RA-TKA using a single robotic system and uniform implant design. Methods: This retrospective review involved 2,647 consecutive primary RA-TKAs undertaken by 27 surgeons at a high-volume academic centre, between 2016 and 2024, using a single CT-based robotic platform and implant design (Triathlon). Patients aged > 18 years with primary osteoarthritis and at least one year of follow-up were included. The method of fixation was determined by the operating surgeon. This resulted in 1,289 cemented and 1,358 cementless RA-TKAs. The mean follow-up was 3.5 years (SD 2.1). Outcomes included Kaplan-Meier survival free from revision (overall, septic, and aseptic), all-cause further surgery, and 90-day readmissions and nonoperative complications. Multivariable Cox regression analysis adjusted for age, BMI, sex, race, ethnicity, and operating time was performed to identify independent predictors. Results: The five-year revision-free survival was 98.0% (95% CI 97.1 to 98.9) and 98.5% (95% CI 97.4 to 99.6) for cemented and cementless fixation, respectively (p = 0.137, log-rank test). Cementless fixation was associated with a significantly decreased risk of septic revision (hazard ratio 0.21 (95% CI 0.03 to 0.71); p = 0.021), whereas there were no differences between the groups for aseptic revision. The five-year survival free from any reoperation was 96.6% (95% CI 95.5 to 97.7) in the cemented group and 97.1% (95% CI 95.9 to 98.4) in the cementless group (p = 0.472, log-rank test). The most common indication for reoperation was stiffness, followed by periprosthetic joint infection. The 90-day readmission and nonoperative complication rates were similar between the groups (p = 0.999 and p = 0.290, respectively). Conclusion: Cementless RA-TKA showed excellent five-year survival with a significantly decreased risk of septic revision compared with cemented RA-TKA. These findings suggest a decreased infection-related risk of failure with cementless fixation, without compromising the short-term implant survival. Cite this article: Bone Joint J 2026;108-B(7):906–912.
- 1 July 2026
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 108-B (7) , 906-912
Lower septic revision rates following cementless compared with cemented robotic-assisted total knee arthroplasty using a single implant design
Aims: The choice of fixation for total knee arthroplasty (TKA) remains controversial. Cementless designs incorporating highly porous titanium surfaces may achieve durable biological fixation and mitigate cement-related complications. However, little has been written comparing the methods of fixation for robotic-assisted (RA) TKA. The aim of this study was to compare the implant survival and complication rates between cemented and cementless RA-TKA using a single robotic system and uniform implant design. Methods: This retrospective review involved 2,647 consecutive primary RA-TKAs undertaken by 27 surgeons at a high-volume academic centre, between 2016 and 2024, using a single CT-based robotic platform and implant design (Triathlon). Patients aged > 18 years with primary osteoarthritis and at least one year of follow-up were included. The method of fixation was determined by the operating surgeon. This resulted in 1,289 cemented and 1,358 cementless RA-TKAs. The mean follow-up was 3.5 years (SD 2.1). Outcomes included Kaplan-Meier survival free from revision (overall, septic, and aseptic), all-cause further surgery, and 90-day readmissions and nonoperative complications. Multivariable Cox regression analysis adjusted for age, BMI, sex, race, ethnicity, and operating time was performed to identify independent predictors. Results: The five-year revision-free survival was 98.0% (95% CI 97.1 to 98.9) and 98.5% (95% CI 97.4 to 99.6) for cemented and cementless fixation, respectively (p = 0.137, log-rank test). Cementless fixation was associated with a significantly decreased risk of septic revision (hazard ratio 0.21 (95% CI 0.03 to 0.71); p = 0.021), whereas there were no differences between the groups for aseptic revision. The five-year survival free from any reoperation was 96.6% (95% CI 95.5 to 97.7) in the cemented group and 97.1% (95% CI 95.9 to 98.4) in the cementless group (p = 0.472, log-rank test). The most common indication for reoperation was stiffness, followed by periprosthetic joint infection. The 90-day readmission and nonoperative complication rates were similar between the groups (p = 0.999 and p = 0.290, respectively). Conclusion: Cementless RA-TKA showed excellent five-year survival with a significantly decreased risk of septic revision compared with cemented RA-TKA. These findings suggest a decreased infection-related risk of failure with cementless fixation, without compromising the short-term implant survival. Cite this article: Bone Joint J 2026;108-B(7):906–912.
- 1 April 2026
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 41 (7) , S274-S281
Stable Fixation in Cementless Total Knee Arthroplasty Even for Low Local Bone Mineral Density
- 1 April 2026
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 41 (7) , S274-S281
Stable Fixation in Cementless Total Knee Arthroplasty Even for Low Local Bone Mineral Density
- 2 February 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (2)
Implant Retrieval Analysis for Total Joint Arthroplasty: A Review
Joint replacement is one of the most successful complex surgical procedures, in large part due to innovations in implant materials and designs. Understanding how implants perform in vivo and why some fail has been crucial to continuous improvement. Analysis of implants retrieved at revision surgery can determine mechanisms driving both performance and failure and suggest necessary changes to address problems. Retrieval analysis can also serve as the earliest warning that an implant system has failed to meet expectations and that a regulatory recall may be the prudent decision. In this review, we provide a history of how retrieval analysis has been leveraged to provide mechanistic answers to design and material problems, to advance implant design and practice, and to provide warnings of early failures. We describe methods to conduct failure analysis of revised implants from subjective observations to quantitative techniques that span engineering, imaging, and pathology. We then present ways in which retrieval analysis has advanced biomaterials and design improvements using the development of polyethylene‐based materials and the discovery of implant tribocorrosion and subsequent mitigation strategies as examples. We also discuss how retrieval analysis was combined with finite element modeling in the evolution of four generations of knee implant design. Finally, we discuss how retrieval analysis can continue to be a valuable resource for joint replacement surgery and implant manufacturing.
- 2 February 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (2)
Implant Retrieval Analysis for Total Joint Arthroplasty: A Review
Joint replacement is one of the most successful complex surgical procedures, in large part due to innovations in implant materials and designs. Understanding how implants perform in vivo and why some fail has been crucial to continuous improvement. Analysis of implants retrieved at revision surgery can determine mechanisms driving both performance and failure and suggest necessary changes to address problems. Retrieval analysis can also serve as the earliest warning that an implant system has failed to meet expectations and that a regulatory recall may be the prudent decision. In this review, we provide a history of how retrieval analysis has been leveraged to provide mechanistic answers to design and material problems, to advance implant design and practice, and to provide warnings of early failures. We describe methods to conduct failure analysis of revised implants from subjective observations to quantitative techniques that span engineering, imaging, and pathology. We then present ways in which retrieval analysis has advanced biomaterials and design improvements using the development of polyethylene‐based materials and the discovery of implant tribocorrosion and subsequent mitigation strategies as examples. We also discuss how retrieval analysis was combined with finite element modeling in the evolution of four generations of knee implant design. Finally, we discuss how retrieval analysis can continue to be a valuable resource for joint replacement surgery and implant manufacturing.
- Open Access
- 2 February 2026
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 8 (1) , 013001
Computational modeling and simulation for medical devices: a summary of the 2024 FDA/MDIC Symposium
Computational modeling and simulation (CM&S) is a powerful tool that can be used to support the development, evaluation, and regulatory authorization of medical devices. CM&S can provide valuable insights into device performance, safety, and effectiveness, as well as reduce the need for animal or human testing. Computational models are, however, idealized digital representations that often have many assumptions and need to be credible before they are used in decision making that could incur patient harm. While the medical device community has made great strides to advance the use of CM&S, a number of challenges remain. To begin addressing these challenges, the US Food and Drug Administration (FDA) and the Medical Device Innovation Consortium (MDIC) co-sponsored the FDA/MDIC Symposium on Computational Modeling and Simulation on April 16–17, 2024 in College Park, Maryland, USA, where attendees from around the world convened to hear from leaders in the field through a unique blend of invited presentations and interactive panel discussions. The symposium agenda covered several major themes, including credibility considerations for CM&S used across the medical device total product life cycle, practical examples of performing model credibility assessment, and the use of CM&S for clinical decision making and the emerging areas of in silico clinical trials and digital twins. The objective of this article is to summarize the major takeaways of the symposium. We first provide an overview of the invited presentations followed by summaries of the topics covered during the interactive panel discussions. In doing so, we highlight the main takeaways and identify areas in which panelists had shared perspectives or differences of opinion. Next, we present the results of a survey conducted at the symposium that sought attendees’ perspectives on different aspects of medical device CM&S. Finally, we conclude by summarizing the major outcomes of the symposium, including areas where more work and investment are needed to advance the field.
- 2 February 2026
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 8 (1) , 013001
Open AccessComputational modeling and simulation for medical devices: a summary of the 2024 FDA/MDIC Symposium
Computational modeling and simulation (CM&S) is a powerful tool that can be used to support the development, evaluation, and regulatory authorization of medical devices. CM&S can provide valuable insights into device performance, safety, and effectiveness, as well as reduce the need for animal or human testing. Computational models are, however, idealized digital representations that often have many assumptions and need to be credible before they are used in decision making that could incur patient harm. While the medical device community has made great strides to advance the use of CM&S, a number of challenges remain. To begin addressing these challenges, the US Food and Drug Administration (FDA) and the Medical Device Innovation Consortium (MDIC) co-sponsored the FDA/MDIC Symposium on Computational Modeling and Simulation on April 16–17, 2024 in College Park, Maryland, USA, where attendees from around the world convened to hear from leaders in the field through a unique blend of invited presentations and interactive panel discussions. The symposium agenda covered several major themes, including credibility considerations for CM&S used across the medical device total product life cycle, practical examples of performing model credibility assessment, and the use of CM&S for clinical decision making and the emerging areas of in silico clinical trials and digital twins. The objective of this article is to summarize the major takeaways of the symposium. We first provide an overview of the invited presentations followed by summaries of the topics covered during the interactive panel discussions. In doing so, we highlight the main takeaways and identify areas in which panelists had shared perspectives or differences of opinion. Next, we present the results of a survey conducted at the symposium that sought attendees’ perspectives on different aspects of medical device CM&S. Finally, we conclude by summarizing the major outcomes of the symposium, including areas where more work and investment are needed to advance the field.
- 11 March 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (7) , S362-S367
A Novel Radiographic Methodology to Measure Knee Adduction Moment Using Routine Biplane Radiographs: Initial Results of 20 Patients
- 11 March 2025
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 40 (7) , S362-S367
A Novel Radiographic Methodology to Measure Knee Adduction Moment Using Routine Biplane Radiographs: Initial Results of 20 Patients
- 5 January 2025
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 43 (4) , 834-841
Finite Element Model of Patient‐Specific Flanged Acetabular Components Highlights Biomechanical Effects of Bone Density and Cortical Shell Thickness
Patient‐specific flanged acetabular components are utilized to treat failed total hip arthroplasties with severe acetabular defects. We previously developed and published a finite element model that investigated the impact of hip joint center lateralization on construct biomechanics during gait conditions. This model consisted of a patient‐specific implant designed to address a superior‐medial defect created in a standard pelvic geometry. This study aims to utilize the same model and examine how cortical shell thickness and ischial cancellous bone density affect the strain distribution in the bone and bone–implant micromotion. Using published studies and bone density analyses of patients who had undergone total hip arthroplasties with flanged acetabular components, we established a thickness range for the cortical shell (1.5, 1, and 0.75 mm) and two levels of ischial cancellous bone density (100% and 25%). We compared the resulting bone strains against the fatigue strength of the bone (0.3% strain) as a criterion for local bone failure and the bone–implant micromotion against the threshold associated with bone ingrowth (20 µm). A thinner pelvic cortical shell and lower ischial cancellous bone density increased areas of bone at risk of failure, particularly at the ischial screws (from 6% to 38%), and decreased areas compatible with bone ingrowth. These findings agree with our clinical knowledge that compromised ischial bone and inadequate ischial fixation negatively impact the survivorship of flanged acetabular components. This series establishes our modeling approach of a computational model that can be utilized to guide implant design to best treat unique acetabular defects.
- 5 January 2025
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 43 (4) , 834-841
Finite Element Model of Patient‐Specific Flanged Acetabular Components Highlights Biomechanical Effects of Bone Density and Cortical Shell Thickness
Patient‐specific flanged acetabular components are utilized to treat failed total hip arthroplasties with severe acetabular defects. We previously developed and published a finite element model that investigated the impact of hip joint center lateralization on construct biomechanics during gait conditions. This model consisted of a patient‐specific implant designed to address a superior‐medial defect created in a standard pelvic geometry. This study aims to utilize the same model and examine how cortical shell thickness and ischial cancellous bone density affect the strain distribution in the bone and bone–implant micromotion. Using published studies and bone density analyses of patients who had undergone total hip arthroplasties with flanged acetabular components, we established a thickness range for the cortical shell (1.5, 1, and 0.75 mm) and two levels of ischial cancellous bone density (100% and 25%). We compared the resulting bone strains against the fatigue strength of the bone (0.3% strain) as a criterion for local bone failure and the bone–implant micromotion against the threshold associated with bone ingrowth (20 µm). A thinner pelvic cortical shell and lower ischial cancellous bone density increased areas of bone at risk of failure, particularly at the ischial screws (from 6% to 38%), and decreased areas compatible with bone ingrowth. These findings agree with our clinical knowledge that compromised ischial bone and inadequate ischial fixation negatively impact the survivorship of flanged acetabular components. This series establishes our modeling approach of a computational model that can be utilized to guide implant design to best treat unique acetabular defects.
- 26 April 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 42 (10) , 2228-2236
Hip joint center lateralization minimally affects the biomechanics of patient‐specific flanged acetabular components: A computational model
Patient‐specific flanged acetabular components are utilized to treat failed total hip arthroplasties with large acetabular defects. Previous clinical studies from our institution showed that these implants tend to lateralize the acetabular center of rotation. However, the clinical impact of lateralization on implant survivorship is debated. Our goal was to develop a finite element model to quantify how lateralization of the native hip center affects periprosthetic strain and implant‐bone micromotion distributions in a static level gait loading condition. To build the model, we computationally created a superomedial acetabular defect in a computed tomography 3D reconstruction of a native pelvis and designed a flanged acetabular implant to address this simulated bone defect. We modeled two implants, one with ~1 cm and a second with ~2 cm of hip center lateralization. We applied the maximum hip contact force and corresponding abductor force observed during level gait. The resulting strains were compared to bone fatigue strength (0.3% strain) and the micromotions were compared to the threshold for bone ingrowth (20 µm). Overall, the model demonstrated that the additional lateralization only slightly increased the area of bone at risk of failure and decreased the areas compatible with bone ingrowth. This computational study of patient‐specific acetabular implants establishes the utility of our modeling approach. Further refinement will yield a model that can explore a multitude of variables and could be used to develop a biomechanically‐based acetabular bone loss classification system to guide the development of patient‐specific implants in the treatment of large acetabular bone defects.
- 26 April 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 42 (10) , 2228-2236
Hip joint center lateralization minimally affects the biomechanics of patient‐specific flanged acetabular components: A computational model
Patient‐specific flanged acetabular components are utilized to treat failed total hip arthroplasties with large acetabular defects. Previous clinical studies from our institution showed that these implants tend to lateralize the acetabular center of rotation. However, the clinical impact of lateralization on implant survivorship is debated. Our goal was to develop a finite element model to quantify how lateralization of the native hip center affects periprosthetic strain and implant‐bone micromotion distributions in a static level gait loading condition. To build the model, we computationally created a superomedial acetabular defect in a computed tomography 3D reconstruction of a native pelvis and designed a flanged acetabular implant to address this simulated bone defect. We modeled two implants, one with ~1 cm and a second with ~2 cm of hip center lateralization. We applied the maximum hip contact force and corresponding abductor force observed during level gait. The resulting strains were compared to bone fatigue strength (0.3% strain) and the micromotions were compared to the threshold for bone ingrowth (20 µm). Overall, the model demonstrated that the additional lateralization only slightly increased the area of bone at risk of failure and decreased the areas compatible with bone ingrowth. This computational study of patient‐specific acetabular implants establishes the utility of our modeling approach. Further refinement will yield a model that can explore a multitude of variables and could be used to develop a biomechanically‐based acetabular bone loss classification system to guide the development of patient‐specific implants in the treatment of large acetabular bone defects.
- 26 March 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 39 (8) , S108-S114
Is Tibial Bone Mineral Density Related to Sex, Age, Preoperative Alignment, or Fixation Method in Primary Total Knee Arthroplasty?
- 26 March 2024
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 39 (8) , S108-S114
Is Tibial Bone Mineral Density Related to Sex, Age, Preoperative Alignment, or Fixation Method in Primary Total Knee Arthroplasty?
- 3 February 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 164, 111973
A novel computational workflow to holistically assess total knee arthroplasty biomechanics identifies subject-specific effects of joint mechanics on implant fixation
- 3 February 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 164, 111973
A novel computational workflow to holistically assess total knee arthroplasty biomechanics identifies subject-specific effects of joint mechanics on implant fixation