Jung-Eun Cheon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jung-Eun Cheon has a total of 314 co-authors. Here are the top co-authors by number of shared publications:
- Young Hun Choi
Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea
56 shared publications - Seunghyun Lee
Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea
37 shared publications - Yeon Jin Cho
Department of Radiology, Seoul National University College of Medicine, Seoul National University Children’s Hospital, 101 Daehak-ro, Jongno-gu, Seoul 03080, Republic of Korea
34 shared publications In-One Kim
Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, South Korea
23 shared publications- Seul Bi Lee
Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea
22 shared publications Woo Sun Kim
Affiliations Department of Radiology, Seoul National University College of Medicine, Seoul, Korea, Department of Radiology and Institute of Radiation Medicine, SNUMRC (Seoul National University Medical Research Center), Seoul National University Hospital, Seoul, Korea, Division of Pediatric Radiology, Seoul National University Children’s Hospital, Seoul, Korea
20 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (5) , 423-425
Ultrasonography in 2025: impact, reach, and future directions
Ultrasonography in 2025: impact, reach, and future directions
- 1 September 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (5) , 423-425
Open AccessUltrasonography in 2025: impact, reach, and future directions
Ultrasonography in 2025: impact, reach, and future directions
- 1 April 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 319 (1) , e252761
Deep Learning–based Bone Mineral Density Prediction Using Pediatric Chest Radiographs: A Multicenter Feasibility Study
An artificial intelligence model using pediatric chest radiographs accurately detected low bone mineral density ( Z score ≤ −2.0) in internal and external test sets.
- 1 April 2026
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 319 (1) , e252761
Deep Learning–based Bone Mineral Density Prediction Using Pediatric Chest Radiographs: A Multicenter Feasibility Study
An artificial intelligence model using pediatric chest radiographs accurately detected low bone mineral density ( Z score ≤ −2.0) in internal and external test sets.
- Open Access
- 3 March 2026
- Published by Springer Nature in Neuroradiology
- Vol. 68 (5) , 1275-1285
Increased risk of neurodevelopmental impairment associated with reduced brain volume at term-equivalent age in preterm infants with germinal matrix hemorrhage
Purpose: To assess the association of low-grade germinal matrix–intraventricular hemorrhage (GM-IVH) with reduced supratentorial and white matter volumes at term-equivalent age, and to evaluate whether these volumes are related to neurodevelopmental impairment (NDI). Methods: This study included preterm infants (gestational age at birth < 37 weeks) who underwent cranial ultrasound within three days of birth and three-dimensional T1-weighted brain magnetic resonance imaging at 34–46 weeks’ postmenstrual age from December 2020 to August 2024. Participants were categorized into the control, GMH (Papile grades 1–2), and punctate white matter lesion (PWML) groups; infants with severe conditions were excluded. A U-Net-based algorithm was used to automatically segment supratentorial and white matter volumes. NDI was defined as a motor score ≤ 85 or cognitive and language scores both ≤ 85 on the Bayley-III. Standardized residuals were calculated to assess volume deviation from the sex-specific reference (control group) and compared according to low-grade GM-IVH and NDI status. A two-way analysis of variance with Tukey’s post hoc test was used for statistical comparison. Results: A total of 171 infants (89 girls; gestational age, 28.32 ± 2.76 weeks; postmenstrual age, 37.81 ± 2.36 weeks) were included, with 119 in the control group, 41 in the GMH group, and 11 in the PWML group. The supratentorial volume-PMA slope was lower in the GMH and PWML groups than in the control group (19.37 cm³/week for control; 12.37 cm³/week for GMH, P = 0.02; 11.49 cm³/week for PWML, P = 0.04). In the GMH group, significant volume differences were observed between the NDI and non-NDI subgroups (standardized residuals: -1.12 ± 0.58 vs. 0.35 ± 0.69 for supratentorial volume; -0.95 ± 0.68 vs. 0.29 ± 0.92 for white matter volume; both P < 0.001), whereas no significant differences were found in the control group. Conclusion: Low-grade GM-IVH with reduced supratentorial or white matter volume is associated with an increased risk of NDI in preterm infants.
- 3 March 2026
- Published by Springer Nature in Neuroradiology
- Vol. 68 (5) , 1275-1285
Open AccessIncreased risk of neurodevelopmental impairment associated with reduced brain volume at term-equivalent age in preterm infants with germinal matrix hemorrhage
Purpose: To assess the association of low-grade germinal matrix–intraventricular hemorrhage (GM-IVH) with reduced supratentorial and white matter volumes at term-equivalent age, and to evaluate whether these volumes are related to neurodevelopmental impairment (NDI). Methods: This study included preterm infants (gestational age at birth < 37 weeks) who underwent cranial ultrasound within three days of birth and three-dimensional T1-weighted brain magnetic resonance imaging at 34–46 weeks’ postmenstrual age from December 2020 to August 2024. Participants were categorized into the control, GMH (Papile grades 1–2), and punctate white matter lesion (PWML) groups; infants with severe conditions were excluded. A U-Net-based algorithm was used to automatically segment supratentorial and white matter volumes. NDI was defined as a motor score ≤ 85 or cognitive and language scores both ≤ 85 on the Bayley-III. Standardized residuals were calculated to assess volume deviation from the sex-specific reference (control group) and compared according to low-grade GM-IVH and NDI status. A two-way analysis of variance with Tukey’s post hoc test was used for statistical comparison. Results: A total of 171 infants (89 girls; gestational age, 28.32 ± 2.76 weeks; postmenstrual age, 37.81 ± 2.36 weeks) were included, with 119 in the control group, 41 in the GMH group, and 11 in the PWML group. The supratentorial volume-PMA slope was lower in the GMH and PWML groups than in the control group (19.37 cm³/week for control; 12.37 cm³/week for GMH, P = 0.02; 11.49 cm³/week for PWML, P = 0.04). In the GMH group, significant volume differences were observed between the NDI and non-NDI subgroups (standardized residuals: -1.12 ± 0.58 vs. 0.35 ± 0.69 for supratentorial volume; -0.95 ± 0.68 vs. 0.29 ± 0.92 for white matter volume; both P < 0.001), whereas no significant differences were found in the control group. Conclusion: Low-grade GM-IVH with reduced supratentorial or white matter volume is associated with an increased risk of NDI in preterm infants.
- Open Access
- 9 February 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Deep learning model for identification of metabolic bone disease of prematurity using wrist radiographs
This study proposes a wrist radiography-based deep learning model for identifying radiographic features of metabolic bone disease (MBD) of prematurity and evaluate the impact of its decision support. This retrospective study included preterm infants with birth weights under 1500 g, born at Seoul National University Hospital (internal dataset: 814 subjects) and Seoul National University Bundang Hospital (external dataset: 261 subjects). Demographic and clinical information and wrist radiographs (postnatal ages: 4–8 weeks) were collected. An internal dataset was used to develop and train identification models and an external dataset was used for validation. Performance was evaluated using the area under the receiver operating characteristic curve (AUROC) and performance quality was compared based on paired t- and Wilcoxon signed-rank tests. The DenseNet-based model exhibited the highest performance quality with AUROC of 0.961 (sensitivity: 94.4%, specificity: 91.2%, accuracy: 92.0%). The external validation study yielded an AUROC of 0.927, indicating its potential applicability in a broad clinical setting. The reader study using external data demonstrated an improved reading performance, especially for non-radiologists (65.4% to 78.7% accuracy; P = 0.008, among pediatricians). The developed model can assist clinicians, especially non-radiologists, in identifying radiographic signs suggestive of MBD, enabling timely diagnosis and treatment to prevent disease progression.
- 9 February 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessDeep learning model for identification of metabolic bone disease of prematurity using wrist radiographs
This study proposes a wrist radiography-based deep learning model for identifying radiographic features of metabolic bone disease (MBD) of prematurity and evaluate the impact of its decision support. This retrospective study included preterm infants with birth weights under 1500 g, born at Seoul National University Hospital (internal dataset: 814 subjects) and Seoul National University Bundang Hospital (external dataset: 261 subjects). Demographic and clinical information and wrist radiographs (postnatal ages: 4–8 weeks) were collected. An internal dataset was used to develop and train identification models and an external dataset was used for validation. Performance was evaluated using the area under the receiver operating characteristic curve (AUROC) and performance quality was compared based on paired t- and Wilcoxon signed-rank tests. The DenseNet-based model exhibited the highest performance quality with AUROC of 0.961 (sensitivity: 94.4%, specificity: 91.2%, accuracy: 92.0%). The external validation study yielded an AUROC of 0.927, indicating its potential applicability in a broad clinical setting. The reader study using external data demonstrated an improved reading performance, especially for non-radiologists (65.4% to 78.7% accuracy; P = 0.008, among pediatricians). The developed model can assist clinicians, especially non-radiologists, in identifying radiographic signs suggestive of MBD, enabling timely diagnosis and treatment to prevent disease progression.
- Open Access
- 1 January 2026
- Published by XMLink in Investigative Magnetic Resonance Imaging
- Vol. 30 (3) , 194-203
Diffusion-Weighted Imaging With Deep Learning Reconstruction in the Pediatric Brain: Comparison With Multi-Shot Diffusion-Weighted Imaging
Yang HY, et al. Investig Magn Reson Imaging. 2026 Sep;30(3):194-203. https://doi.org/10.13104/imri.2026.0018
- 1 January 2026
- Published by XMLink in Investigative Magnetic Resonance Imaging
- Vol. 30 (3) , 194-203
Open AccessDiffusion-Weighted Imaging With Deep Learning Reconstruction in the Pediatric Brain: Comparison With Multi-Shot Diffusion-Weighted Imaging
Yang HY, et al. Investig Magn Reson Imaging. 2026 Sep;30(3):194-203. https://doi.org/10.13104/imri.2026.0018
- Open Access
- 1 January 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (1) , 1-2
Ultrasonography in 2026: accelerating progress and defining the future of ultrasound
Ultrasonography in 2026: accelerating progress and defining the future of ultrasound
- 1 January 2026
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 45 (1) , 1-2
Open AccessUltrasonography in 2026: accelerating progress and defining the future of ultrasound
Ultrasonography in 2026: accelerating progress and defining the future of ultrasound
- Open Access
- 12 November 2025
- Published by Springer Nature in Pediatric Radiology
- Vol. 56 (2) , 348-356
Deep learning-enhanced zero echo time silent brain magnetic resonance imaging in infants without sedation
Background: Reducing acoustic noise is essential in infant brain magnetic resonance imaging (MRI) to minimize the need for sedation. Deep learning (DL)–based MRI reconstruction may enhance the image quality of the zero echo time (ZTE) silent sequence. Objective: To evaluate the effect of DL-based reconstruction on the image quality of ZTE infant brain MRI using the feed-and-wrap technique, compared to conventional MRI with sedation. Materials and methods: This retrospective study included 78 infants (postmenstrual age ≤16 months) who underwent brain MRI between January 2022 and December 2024. The control group underwent sedated 3-dimensional T1-weighted magnetization-prepared rapid gradient-echo (MPRAGE) imaging. The experimental group underwent unsedated inversion recovery-prepared ZTE imaging with and without DL-based reconstruction (ZTE-DL and ZTE, respectively), using the feed-and-wrap technique. Three radiologists independently rated five image quality metrics using a 5-point Likert scale. Signal uniformity was assessed by the coefficient of variation across eight brain regions. Differences among sequences were analyzed using the Mann–Whitney U test with Bonferroni correction. Interrater agreement was assessed using Cohen’s kappa coefficient. Results: ZTE-DL had the highest scores for noisiness, gray-white matter differentiation, artifacts, and overall image quality. ZTE-DL showed no significant differences from MPRAGE except for reduced noisiness, while significantly outperforming ZTE across all metrics (all P 0.6) for most metrics. Signal uniformity was greatest in ZTE-DL for gray and white matter (all P P =0.721). Conclusion: DL-based MRI reconstruction improved ZTE image quality and provided comparable image quality to MPRAGE, potentially reducing the need for sedation in infant brain MRI. Graphical
- 12 November 2025
- Published by Springer Nature in Pediatric Radiology
- Vol. 56 (2) , 348-356
Open AccessDeep learning-enhanced zero echo time silent brain magnetic resonance imaging in infants without sedation
Background: Reducing acoustic noise is essential in infant brain magnetic resonance imaging (MRI) to minimize the need for sedation. Deep learning (DL)–based MRI reconstruction may enhance the image quality of the zero echo time (ZTE) silent sequence. Objective: To evaluate the effect of DL-based reconstruction on the image quality of ZTE infant brain MRI using the feed-and-wrap technique, compared to conventional MRI with sedation. Materials and methods: This retrospective study included 78 infants (postmenstrual age ≤16 months) who underwent brain MRI between January 2022 and December 2024. The control group underwent sedated 3-dimensional T1-weighted magnetization-prepared rapid gradient-echo (MPRAGE) imaging. The experimental group underwent unsedated inversion recovery-prepared ZTE imaging with and without DL-based reconstruction (ZTE-DL and ZTE, respectively), using the feed-and-wrap technique. Three radiologists independently rated five image quality metrics using a 5-point Likert scale. Signal uniformity was assessed by the coefficient of variation across eight brain regions. Differences among sequences were analyzed using the Mann–Whitney U test with Bonferroni correction. Interrater agreement was assessed using Cohen’s kappa coefficient. Results: ZTE-DL had the highest scores for noisiness, gray-white matter differentiation, artifacts, and overall image quality. ZTE-DL showed no significant differences from MPRAGE except for reduced noisiness, while significantly outperforming ZTE across all metrics (all P 0.6) for most metrics. Signal uniformity was greatest in ZTE-DL for gray and white matter (all P P =0.721). Conclusion: DL-based MRI reconstruction improved ZTE image quality and provided comparable image quality to MPRAGE, potentially reducing the need for sedation in infant brain MRI. Graphical
- 29 October 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 99 (1178) , 319-325
Development and validation of a deep learning-based algorithm for quantifying bronchiolitis obliterans in paediatric computed tomography
Objectives: To develop and validate a deep learning-based algorithm for quantifying bronchiolitis obliterans (BO) on paediatric chest CT. Methods: This retrospective study included 86 children (39 males; median age, 10 years) diagnosed with BO who underwent both inspiratory and expiratory CT between January 2018 and November 2021. The deep learning-based BO quantification model was trained on 26 CT scans using a 3D nnU-Net, with radiologist-segmented low attenuation regions (LARs) serving as ground truth. Model performance was evaluated through internal test with 4 CT scans and external test with 6 CT scans. Intra-vendor robustness was assessed using 22 CT scans with varying reconstruction methods, kernel types, and slice thicknesses. Comparison with semiquantitative radiologist grading was performed using 28 CT scans. Dice similarity coefficient (DSC), sensitivity, and precision were used to evaluate model performance. Results: The model achieved a DSC of 85.41 ± 3.28%, sensitivity of 85.14 ± 7.66%, and precision of 86.21 ± 3.92% in the internal test, and 82.53 ± 4.34%, 82.17 ± 6.15%, and 84.15 ± 3.16% in the external test, respectively. For intra-vendor robustness, no significant differences in BO quantification were observed across different reconstruction methods, kernel types, and slice thicknesses (all P > .05). Compared to radiologists’ grading, the model demonstrated strong to very strong correlations across all lung lobes (all P < .001). Conclusion: The model demonstrated accurate quantification of BO on paediatric CT, with good agreement with the radiologist-segmented ground truth. Advances in knowledge: This study presents a 3D nnU-Net-based deep learning algorithm for robust quantification of BO on paediatric CT, providing reproducible measurements of LARs.
- 29 October 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 99 (1178) , 319-325
Development and validation of a deep learning-based algorithm for quantifying bronchiolitis obliterans in paediatric computed tomography
Objectives: To develop and validate a deep learning-based algorithm for quantifying bronchiolitis obliterans (BO) on paediatric chest CT. Methods: This retrospective study included 86 children (39 males; median age, 10 years) diagnosed with BO who underwent both inspiratory and expiratory CT between January 2018 and November 2021. The deep learning-based BO quantification model was trained on 26 CT scans using a 3D nnU-Net, with radiologist-segmented low attenuation regions (LARs) serving as ground truth. Model performance was evaluated through internal test with 4 CT scans and external test with 6 CT scans. Intra-vendor robustness was assessed using 22 CT scans with varying reconstruction methods, kernel types, and slice thicknesses. Comparison with semiquantitative radiologist grading was performed using 28 CT scans. Dice similarity coefficient (DSC), sensitivity, and precision were used to evaluate model performance. Results: The model achieved a DSC of 85.41 ± 3.28%, sensitivity of 85.14 ± 7.66%, and precision of 86.21 ± 3.92% in the internal test, and 82.53 ± 4.34%, 82.17 ± 6.15%, and 84.15 ± 3.16% in the external test, respectively. For intra-vendor robustness, no significant differences in BO quantification were observed across different reconstruction methods, kernel types, and slice thicknesses (all P > .05). Compared to radiologists’ grading, the model demonstrated strong to very strong correlations across all lung lobes (all P < .001). Conclusion: The model demonstrated accurate quantification of BO on paediatric CT, with good agreement with the radiologist-segmented ground truth. Advances in knowledge: This study presents a 3D nnU-Net-based deep learning algorithm for robust quantification of BO on paediatric CT, providing reproducible measurements of LARs.
- Open Access
- 1 September 2025
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 44 (5) , 380-388
Effect of breath control on hepatic shear wave elasticity and dispersion in pediatric patients
Purpose: This study aimed to evaluate the effect of breath control on the reliability of two-dimensional shear wave elastography (2D-SWE) and shear wave dispersion (SWD) measurements in pediatric patients.Methods: This study included a retrospective cohort of 163 children and a prospective cohort of 27 children (aged 8-17 years). All participants underwent 2D-SWE and SWD under both free-breathing and breath-hold conditions between September 2021 and February 2023. The prospective cohort also underwent magnetic resonance elastography (MRE). Liver stiffness and dispersion values were compared between respiratory conditions. Inter- and intra-rater agreements were assessed, and correlations with MRE were analyzed in the prospective cohort.Results: Liver stiffness and dispersion values were significantly higher during free-breathing compared to breath-hold (mean differences: 0.22 kPa and 0.39 m/s/kHz, respectively; both P0.99) and SWD (ICC, 0.70 vs. 0.74; P=0.396) remained moderate to good and did not differ significantly between conditions. The correlation between 2D-SWE and MRE was stronger under breath-hold than free-breathing (r=0.73 vs. r=0.56), although this difference was not statistically significant (P=0.299).Conclusion: Breath-holding increases the reliability of pediatric 2D-SWE and SWD by improving inter-rater agreement and correlation with MRE. However, free-breathing also demonstrates comparable reproducibility with minimal bias, supporting its clinical feasibility for use in uncooperative pediatric patients.
- 1 September 2025
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 44 (5) , 380-388
Open AccessEffect of breath control on hepatic shear wave elasticity and dispersion in pediatric patients
Purpose: This study aimed to evaluate the effect of breath control on the reliability of two-dimensional shear wave elastography (2D-SWE) and shear wave dispersion (SWD) measurements in pediatric patients.Methods: This study included a retrospective cohort of 163 children and a prospective cohort of 27 children (aged 8-17 years). All participants underwent 2D-SWE and SWD under both free-breathing and breath-hold conditions between September 2021 and February 2023. The prospective cohort also underwent magnetic resonance elastography (MRE). Liver stiffness and dispersion values were compared between respiratory conditions. Inter- and intra-rater agreements were assessed, and correlations with MRE were analyzed in the prospective cohort.Results: Liver stiffness and dispersion values were significantly higher during free-breathing compared to breath-hold (mean differences: 0.22 kPa and 0.39 m/s/kHz, respectively; both P0.99) and SWD (ICC, 0.70 vs. 0.74; P=0.396) remained moderate to good and did not differ significantly between conditions. The correlation between 2D-SWE and MRE was stronger under breath-hold than free-breathing (r=0.73 vs. r=0.56), although this difference was not statistically significant (P=0.299).Conclusion: Breath-holding increases the reliability of pediatric 2D-SWE and SWD by improving inter-rater agreement and correlation with MRE. However, free-breathing also demonstrates comparable reproducibility with minimal bias, supporting its clinical feasibility for use in uncooperative pediatric patients.
- Open Access
- 1 September 2025
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 44 (5) , 305-307
Ultrasonography in evolution: current position and priorities for global expansion
- 1 September 2025
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 44 (5) , 305-307
Open AccessUltrasonography in evolution: current position and priorities for global expansion