Xavier Simon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xavier Simon has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
Philippe Duquenne
Institut National de Recherche et de Sécurité au Travail (INRS), Vandoeuvre les Nancy, France
9 shared publications- Philippe Duquenne
Process Engineering Division, National Research and Safety Institute (INRS), 1 Rue du Morvan CS 60027, CEDEX, 54519 Vandœuvre-lès-Nancy, France
8 shared publications Denis Bémer
4 shared publications- Sébastien Bau
INRS, Laboratoire de Métrologie des Aérosols, 54500 Vandoeuvre les Nancy
4 shared publications - Dominique Thomas
Université de Lorraine, CNRS, LRGP Nancy France
3 shared publications Jodelle Degois
Department of pollutant metrology, Institut National de Recherche et de Sécurité (INRS), Vandœuvre-lès-Nancy 54500, France
3 shared publications
Latest Publications
- Open Access
- 8 April 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (4) , 461
Bioaerosol Exposure during Sorting of Municipal Solid, Commercial and Industrial Waste: Concentration Levels, Size Distribution, and Biodiversity of Airborne Fungal
A study was carried out in a waste sorting plant (WSP) located in France, treating dry recyclable household waste (DRHW) as well as dry recyclable commercial and industrial waste (DRCIW). Stationary and personal inhalable samples were collected in the WSP in order to investigate bioaerosols (sampling on a filter; 2 L/min and 10 L/min) and airborne dust (CIP; 10 L/min). The aim of the study was to assess the extent to which the measurement of concentration, species composition, and particle size distribution contributes to a better assessment of the biological risks associated with exposure. The results confirmed that waste and waste sorting activities are sources of airborne fungi. Indeed, ambient concentrations ranged from 7.3 × 103 to 8.5 × 105 colony-forming units (CFU)/m3 for culturable fungi and up to 4 mg/m3 for dust. Personal exposure to inhalable dust was found up to 3 mg/m3 for dust and ranged from 8.6 × 103 to 1.5 × 106 CFU/m3 for fungi. Airborne fungal communities were found to be dominated by the Penicillium genera in both bioaerosols and settled dust samples, followed by the Aspergillus, Cladosporium, Wallemia, Mucor, and Rhizopus genera. Fungi were carried by particles of aerodynamic diameters, mainly between around 2.0 and 10.0 µm. The findings dealing with size distribution and biodiversity of bioaerosols suggest that employees are exposed to complex bioaerosols during their work and help to make a finer diagnosis of the risks involved, which is often difficult in the absence of any occupational exposure limit (OEL) value for bioaerosols in general.
- 8 April 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (4) , 461
Open AccessBioaerosol Exposure during Sorting of Municipal Solid, Commercial and Industrial Waste: Concentration Levels, Size Distribution, and Biodiversity of Airborne Fungal
A study was carried out in a waste sorting plant (WSP) located in France, treating dry recyclable household waste (DRHW) as well as dry recyclable commercial and industrial waste (DRCIW). Stationary and personal inhalable samples were collected in the WSP in order to investigate bioaerosols (sampling on a filter; 2 L/min and 10 L/min) and airborne dust (CIP; 10 L/min). The aim of the study was to assess the extent to which the measurement of concentration, species composition, and particle size distribution contributes to a better assessment of the biological risks associated with exposure. The results confirmed that waste and waste sorting activities are sources of airborne fungi. Indeed, ambient concentrations ranged from 7.3 × 103 to 8.5 × 105 colony-forming units (CFU)/m3 for culturable fungi and up to 4 mg/m3 for dust. Personal exposure to inhalable dust was found up to 3 mg/m3 for dust and ranged from 8.6 × 103 to 1.5 × 106 CFU/m3 for fungi. Airborne fungal communities were found to be dominated by the Penicillium genera in both bioaerosols and settled dust samples, followed by the Aspergillus, Cladosporium, Wallemia, Mucor, and Rhizopus genera. Fungi were carried by particles of aerodynamic diameters, mainly between around 2.0 and 10.0 µm. The findings dealing with size distribution and biodiversity of bioaerosols suggest that employees are exposed to complex bioaerosols during their work and help to make a finer diagnosis of the risks involved, which is often difficult in the absence of any occupational exposure limit (OEL) value for bioaerosols in general.
- Open Access
- 28 February 2024
- Published by MDPI AG in Preprints.org
Bioaerosol Exposure during Sorting of Municipal Solid, Commercial and Industrial Waste: Concentration Levels, Size Distribution, and Biodiversity of Airborne Fungal
A study was carried out in a Waste Sorting Plant (WSP) located in France and treating dry recyclable household waste (DRHW) as well as dry recyclable commercial and industrial waste (DRCIW). The aim was to investigate the exposure to bioaerosol and dust. The aim of the study was to assess the extent to which the measurement of concentration, species composition and particle size distribution can contribute to a better assessment of the biological risks associated with exposure. Both stationary and personal bioaerosol and dust samples were collect in the (WSP). The results confirm that waste and waste sorting activities are sources of airborne fungi. Indeed, ambient concentrations ranged from 7.3×103 to 8.5×105 CFU/m3 for culturable moulds and up to up to 4 mg/m3 for dust. Personal exposure to inhalable dust was found up to 3 mg/m3 for dust and ranged from 8.6×103 to 1.5×106 CFU/m3 for fungi. Airborne fungal communities were found to be dominated by the Penicillium genera in both bioaerosols and settled dust samples, followed by the Aspergillus, Cladosporium, Wallemia, Mucor, and Rhizopus genera. Fungi were carried by particles of aerodynamic diameters mainly between around 2.0 and 10.0 µm. The findings dealing with size distribution and biodiversity of bioaerosols suggest that employees are exposed to complex bioaerosols during their work and helps to make a finer diagnosis of the risks involved, which is often difficult in the absence of any OEL for bioaerosols in general.
- 28 February 2024
- Published by MDPI AG in Preprints.org
Open AccessBioaerosol Exposure during Sorting of Municipal Solid, Commercial and Industrial Waste: Concentration Levels, Size Distribution, and Biodiversity of Airborne Fungal
A study was carried out in a Waste Sorting Plant (WSP) located in France and treating dry recyclable household waste (DRHW) as well as dry recyclable commercial and industrial waste (DRCIW). The aim was to investigate the exposure to bioaerosol and dust. The aim of the study was to assess the extent to which the measurement of concentration, species composition and particle size distribution can contribute to a better assessment of the biological risks associated with exposure. Both stationary and personal bioaerosol and dust samples were collect in the (WSP). The results confirm that waste and waste sorting activities are sources of airborne fungi. Indeed, ambient concentrations ranged from 7.3×103 to 8.5×105 CFU/m3 for culturable moulds and up to up to 4 mg/m3 for dust. Personal exposure to inhalable dust was found up to 3 mg/m3 for dust and ranged from 8.6×103 to 1.5×106 CFU/m3 for fungi. Airborne fungal communities were found to be dominated by the Penicillium genera in both bioaerosols and settled dust samples, followed by the Aspergillus, Cladosporium, Wallemia, Mucor, and Rhizopus genera. Fungi were carried by particles of aerodynamic diameters mainly between around 2.0 and 10.0 µm. The findings dealing with size distribution and biodiversity of bioaerosols suggest that employees are exposed to complex bioaerosols during their work and helps to make a finer diagnosis of the risks involved, which is often difficult in the absence of any OEL for bioaerosols in general.
- 1 February 2021
- Published by Elsevier in Waste Management
- Vol. 120, 257-268
One-year follow-up of microbial diversity in bioaerosols emitted in a waste sorting plant in France
- 1 February 2021
- Published by Elsevier in Waste Management
- Vol. 120, 257-268
One-year follow-up of microbial diversity in bioaerosols emitted in a waste sorting plant in France
- 1 January 2021
- Published by Elsevier
- p. 49-58
Airborne Fungi in Workplace Atmospheres: Overview of Active Sampling and Offline Analysis Methods Used in 2009–2019
- 1 January 2021
- Published by Elsevier
- p. 49-58
Airborne Fungi in Workplace Atmospheres: Overview of Active Sampling and Offline Analysis Methods Used in 2009–2019
- 18 March 2019
- Published by Taylor & Francis in Archives of Environmental & Occupational Health
- Vol. 75 (4) , 191-200
Effects of plant features on symptoms and airway inflammation in compost workers followed over 18 months
This study investigated the plant features associated with increased irritation symptoms and levels of inflammation markers among compost workers (CWs). Ninety CWs were followed over 18 months, using questionnaires on respiratory symptoms, fractional exhaled nitric oxide measurements, spirometry, a methacholine bronchial challenge test, and quantification of specific immunoglobulins E (IgE) and G. CWs in plants processing the highest quantities of waste exhibited more airway irritation symptoms. So did the CWs in partially and fully indoor plants as compared to those in plants entirely outdoors. Working in sewage sludge versus green waste plants and having a high level of exposure were associated with higher levels of different IgE. The duration of employment decreased the FEV1 by 16 ml per year. Working in an indoor plant is linked to symptoms and inflammation markers in CWs.
- 18 March 2019
- Published by Taylor & Francis in Archives of Environmental & Occupational Health
- Vol. 75 (4) , 191-200
Effects of plant features on symptoms and airway inflammation in compost workers followed over 18 months
This study investigated the plant features associated with increased irritation symptoms and levels of inflammation markers among compost workers (CWs). Ninety CWs were followed over 18 months, using questionnaires on respiratory symptoms, fractional exhaled nitric oxide measurements, spirometry, a methacholine bronchial challenge test, and quantification of specific immunoglobulins E (IgE) and G. CWs in plants processing the highest quantities of waste exhibited more airway irritation symptoms. So did the CWs in partially and fully indoor plants as compared to those in plants entirely outdoors. Working in sewage sludge versus green waste plants and having a high level of exposure were associated with higher levels of different IgE. The duration of employment decreased the FEV1 by 16 ml per year. Working in an indoor plant is linked to symptoms and inflammation markers in CWs.
- Open Access
- 27 December 2018
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 53 (2) , 146-159
Characterization of experimental complex fungal bioaerosols: Impact of analytical method on fungal composition measurements
The microbial composition of bioaerosols is an important issue to investigate to better understand occupational risks linked to exposure to airborne particles. Traditional methods are based on culture followed by colony identification by morphological, molecular biology or biochemical approaches. We have carried out a preliminary study which aims were to generate reproducible complex bioaerosols and to compare a HTS approach to the traditional culture-based approach. Mixed fungal bioaerosols containing four fungal strains (Aspergillus niger, Cladosporium cladosporioides, Penicillium brevicompactum and Wallemia melicolla) were generated in the laboratory using a bubbling aerosolizer. The fungal composition was assessed by culture and sequencing. Two genetic targets were sequenced and two assignment methods were compared. Wallemia was poorly detected by the culture-based approach, whereas Aspergillus was readily observed, in significant proportions, only by this method. The proportions in the liquid suspensions and in the bioaerosols generated were nearly identical. Sequencing of the ITS2 region provided results better reflecting the theoretical composition than 18S rDNA sequencing. The findings show that results of fungal composition investigations are strongly dependent on the analysis method used. Further studies will be required to assess the impact of these findings when considering biodiversity in complex and unknown environments.
- 27 December 2018
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 53 (2) , 146-159
Open AccessCharacterization of experimental complex fungal bioaerosols: Impact of analytical method on fungal composition measurements
The microbial composition of bioaerosols is an important issue to investigate to better understand occupational risks linked to exposure to airborne particles. Traditional methods are based on culture followed by colony identification by morphological, molecular biology or biochemical approaches. We have carried out a preliminary study which aims were to generate reproducible complex bioaerosols and to compare a HTS approach to the traditional culture-based approach. Mixed fungal bioaerosols containing four fungal strains (Aspergillus niger, Cladosporium cladosporioides, Penicillium brevicompactum and Wallemia melicolla) were generated in the laboratory using a bubbling aerosolizer. The fungal composition was assessed by culture and sequencing. Two genetic targets were sequenced and two assignment methods were compared. Wallemia was poorly detected by the culture-based approach, whereas Aspergillus was readily observed, in significant proportions, only by this method. The proportions in the liquid suspensions and in the bioaerosols generated were nearly identical. Sequencing of the ITS2 region provided results better reflecting the theoretical composition than 18S rDNA sequencing. The findings show that results of fungal composition investigations are strongly dependent on the analysis method used. Further studies will be required to assess the impact of these findings when considering biodiversity in complex and unknown environments.
- 1 February 2018
- Published by Elsevier in Journal of Aerosol Science
- Vol. 116, 92-105
Performances of the BC-112 NIOSH cyclone for the measurement of endotoxins in bioaerosols: A study in laboratory conditions
- 1 February 2018
- Published by Elsevier in Journal of Aerosol Science
- Vol. 116, 92-105
Performances of the BC-112 NIOSH cyclone for the measurement of endotoxins in bioaerosols: A study in laboratory conditions
- 23 September 2017
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 61 (9) , 1076-1086
First Metagenomic Survey of the Microbial Diversity in Bioaerosols Emitted in Waste Sorting Plants
Waste sorting activities are source of occupational bioaerosol exposures that are associated with several health disorders. New analytical tools, based on next-generation sequencing (NGS) technologies, provide powerful methods to assess the microbial composition of bioaerosols. The objectives of the study were (i) to assess the feasibility and the repeatability of NGS-based biodiversity measurements and (ii) to study the microbial biodiversity using NGS in bioaerosols emitted in a waste sorting plant (WSP). Three stationary parallel samples were collected in a sorting cabin using closed-face cassettes equipped with polycarbonate membranes. Bacterial and fungal diversity was assessed by sequencing 16S and 18S rDNA genes using either Illumina sequencing or 454 pyrosequencing methods. At sampling point, airborne bacteria were dominated by Proteobacteria, Firmicutes, and Actinobacteria with prevailing genera assigned to unclassified Enterobacteriaceae, Staphylococcus, Acinetobacter, Leuconostoc, Pseudomonas, and Lactobacillus. Airborne fungi were dominated by Ascomycota with prevailing genera assigned to Penicillium, Aspergillus, Rhizopus, Wallemia, and Hemicarpenteles. The NGS biodiversity measurements revealed a higher biodiversity bioaerosols that previously reported for WSP in studies carried out using culture methods followed by identification of microorganisms. These results provide the first survey about taxonomic biodiversity in bioaerosols from WSPs using high-throughput sequencing.
- 23 September 2017
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 61 (9) , 1076-1086
First Metagenomic Survey of the Microbial Diversity in Bioaerosols Emitted in Waste Sorting Plants
Waste sorting activities are source of occupational bioaerosol exposures that are associated with several health disorders. New analytical tools, based on next-generation sequencing (NGS) technologies, provide powerful methods to assess the microbial composition of bioaerosols. The objectives of the study were (i) to assess the feasibility and the repeatability of NGS-based biodiversity measurements and (ii) to study the microbial biodiversity using NGS in bioaerosols emitted in a waste sorting plant (WSP). Three stationary parallel samples were collected in a sorting cabin using closed-face cassettes equipped with polycarbonate membranes. Bacterial and fungal diversity was assessed by sequencing 16S and 18S rDNA genes using either Illumina sequencing or 454 pyrosequencing methods. At sampling point, airborne bacteria were dominated by Proteobacteria, Firmicutes, and Actinobacteria with prevailing genera assigned to unclassified Enterobacteriaceae, Staphylococcus, Acinetobacter, Leuconostoc, Pseudomonas, and Lactobacillus. Airborne fungi were dominated by Ascomycota with prevailing genera assigned to Penicillium, Aspergillus, Rhizopus, Wallemia, and Hemicarpenteles. The NGS biodiversity measurements revealed a higher biodiversity bioaerosols that previously reported for WSP in studies carried out using culture methods followed by identification of microorganisms. These results provide the first survey about taxonomic biodiversity in bioaerosols from WSPs using high-throughput sequencing.
- 18 July 2017
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 61 (7) , 784-796
Sampling Efficiency and Performance of Selected Thoracic Aerosol Samplers
Measurement of worker exposure to a thoracic health-related aerosol fraction is necessary in a number of occupational situations. This is the case of workplaces with atmospheres polluted by fibrous particles, such as cotton dust or asbestos, and by particles inducing irritation or bronchoconstriction such as acid mists or flour dust. Three personal and two static thoracic aerosol samplers were tested under laboratory conditions. Sampling efficiency with respect to particle aerodynamic diameter was measured in a horizontal low wind tunnel and in a vertical calm air chamber. Sampling performance was evaluated against conventional thoracic penetration. Three of the tested samplers performed well, when sampling the thoracic aerosol at nominal flow rate and two others performed well at optimized flow rate. The limit of flow rate optimization was found when using cyclone samplers.
- 18 July 2017
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 61 (7) , 784-796
Sampling Efficiency and Performance of Selected Thoracic Aerosol Samplers
Measurement of worker exposure to a thoracic health-related aerosol fraction is necessary in a number of occupational situations. This is the case of workplaces with atmospheres polluted by fibrous particles, such as cotton dust or asbestos, and by particles inducing irritation or bronchoconstriction such as acid mists or flour dust. Three personal and two static thoracic aerosol samplers were tested under laboratory conditions. Sampling efficiency with respect to particle aerodynamic diameter was measured in a horizontal low wind tunnel and in a vertical calm air chamber. Sampling performance was evaluated against conventional thoracic penetration. Three of the tested samplers performed well, when sampling the thoracic aerosol at nominal flow rate and two others performed well at optimized flow rate. The limit of flow rate optimization was found when using cyclone samplers.