Michael Huggan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Anne Neville
School of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK
3 shared publications - Richard Barker
School of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK
2 shared publications - Thibaut Charpentier
University of Leeds
2 shared publications - Ali Ghanbarzadeh
Institute of Functional Surfaces, School of Mechanical Engineering, University of Leeds, Leeds, UK
1 shared publication - Andrew Jackson
School of Mechanical Engineering, Institute of Functional Surfaces, University of Leeds, Leeds, West Yorkshire LS2 9JT, United Kingdom
1 shared publication - Bernard Normand
Ipsé, Laboratoire d'Etudes et de Recherches sur les Matériaux et Propriétés de Surface (LERMPS), Belfort, France
1 shared publication
Latest Publications
- Open Access
- 5 December 2023
- Published by Elsevier in Corrosion Science
- Vol. 228
Electrochemical investigation on localised corrosion under silica sand deposit layers of carbon steel within a bespoke test cell
- 5 December 2023
- Published by Elsevier in Corrosion Science
- Vol. 228
Open AccessElectrochemical investigation on localised corrosion under silica sand deposit layers of carbon steel within a bespoke test cell
- 21 June 2019
- Published by SAGE Publications in Corrosion Engineering, Science and Technology: The International Journal of Corrosion Processes and Corrosion Control
- Vol. 54 (7) , 547-555
Development and evaluation of miniature electrodes for electrochemical measurements in a CO2 top of line corrosion environment
Top of line corrosion (TLC) is a degradation mechanism which establishes itself in ‘wet gas’ pipelines under significant temperature difference between the internal fluid and the outer pipe wall. Laboratory evaluation of TLC is based predominantly on the mass loss method which is an averaging approach. Hence, a real-time and spatially resolved corrosion response would add an extra dimension in terms of corrosion measurement. This work presents a new apparatus to explore the ability of a miniature three-electrode cell to provide instantaneous corrosion measurements in a TLC scenario. The electrochemical system is integrated into a buoyancy-driven flow TLC setup and is used to monitor instantaneous corrosion rates for X65 carbon steel over 20h through a combination of linear polarisation resistance, electrochemical impedance spectroscopy and Tafel measurements. The electrochemical responses are compared with gravimetric results under identical conditions and generating repeatable, accurate and instantaneous data to provide more insight into TLC mechanism.
- 21 June 2019
- Published by SAGE Publications in Corrosion Engineering, Science and Technology: The International Journal of Corrosion Processes and Corrosion Control
- Vol. 54 (7) , 547-555
Development and evaluation of miniature electrodes for electrochemical measurements in a CO2 top of line corrosion environment
Top of line corrosion (TLC) is a degradation mechanism which establishes itself in ‘wet gas’ pipelines under significant temperature difference between the internal fluid and the outer pipe wall. Laboratory evaluation of TLC is based predominantly on the mass loss method which is an averaging approach. Hence, a real-time and spatially resolved corrosion response would add an extra dimension in terms of corrosion measurement. This work presents a new apparatus to explore the ability of a miniature three-electrode cell to provide instantaneous corrosion measurements in a TLC scenario. The electrochemical system is integrated into a buoyancy-driven flow TLC setup and is used to monitor instantaneous corrosion rates for X65 carbon steel over 20h through a combination of linear polarisation resistance, electrochemical impedance spectroscopy and Tafel measurements. The electrochemical responses are compared with gravimetric results under identical conditions and generating repeatable, accurate and instantaneous data to provide more insight into TLC mechanism.
- 1 March 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (3) , 034101
Development of an automated underwater abrasion rig to determine galvanic effects during the growth and localised breakdown of surface films in CO2-containing solutions
This paper outlines the development of an automated underwater abrasion rig to assist in understanding the galvanic interaction induced by surface films when continuous localised mechanical film breakdown is encountered on the surface of carbon steel in CO2-containing environments. The rig enables the measurement of galvanic current between a small X65 steel pin and a larger steel specimen, as well as the intrinsic corrosion rate of an additional, uncoupled larger specimen. The surface film developed on the pin is removed periodically using an automated reciprocating and rotating shaft with a sand paper grit pad attached to the base, while the surface film is allowed to establish itself undisrupted on the large specimen. The setup essentially simulates a tribo-corrosion process where local removal of material occurs within a carbon steel pipeline as a result of periodic sand particle impingement. Initial results focus on validating the reproducibility of the technique, as well as determining the galvanic effects associated with iron carbide and iron carbonate for two model sets of conditions to highlight the capabilities of the system.
- 1 March 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (3) , 034101
Development of an automated underwater abrasion rig to determine galvanic effects during the growth and localised breakdown of surface films in CO2-containing solutions
This paper outlines the development of an automated underwater abrasion rig to assist in understanding the galvanic interaction induced by surface films when continuous localised mechanical film breakdown is encountered on the surface of carbon steel in CO2-containing environments. The rig enables the measurement of galvanic current between a small X65 steel pin and a larger steel specimen, as well as the intrinsic corrosion rate of an additional, uncoupled larger specimen. The surface film developed on the pin is removed periodically using an automated reciprocating and rotating shaft with a sand paper grit pad attached to the base, while the surface film is allowed to establish itself undisrupted on the large specimen. The setup essentially simulates a tribo-corrosion process where local removal of material occurs within a carbon steel pipeline as a result of periodic sand particle impingement. Initial results focus on validating the reproducibility of the technique, as well as determining the galvanic effects associated with iron carbide and iron carbonate for two model sets of conditions to highlight the capabilities of the system.
- 1 October 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (10) , 103903
Development of a novel once-through flow visualization technique for kinetic study of bulk and surface scaling
There is a considerable interest to investigate surface crystallization in order to have a full mechanistic understanding of how layers of sparingly soluble salts (scale) build on component surfaces. Despite much recent attention, a suitable methodology to improve on the understanding of the precipitation/deposition systems to enable the construction of an accurate surface deposition kinetic model is still needed. In this work, an experimental flow rig and associated methodology to study mineral scale deposition is developed. The once-through flow rig allows us to follow mineral scale precipitation and surface deposition in situ and in real time. The rig enables us to assess the effects of various parameters such as brine chemistry and scaling indices, temperature, flow rates, and scale inhibitor concentrations on scaling kinetics. Calcium carbonate (CaCO3) scaling at different values of the saturation ratio (SR) is evaluated using image analysis procedures that enable the assessment of surface coverage, nucleation, and growth of the particles with time. The result for turbidity values measured in the flow cell is zero for all the SR considered. The residence time from the mixing point to the sample is shorter than the induction time for bulk precipitation; therefore, there are no crystals in the bulk solution as the flow passes through the sample. The study shows that surface scaling is not always a result of pre-precipitated crystals in the bulk solution. The technique enables both precipitation and surface deposition of scale to be decoupled and for the surface deposition process to be studied in real time and assessed under constant condition.
- 1 October 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (10) , 103903
Development of a novel once-through flow visualization technique for kinetic study of bulk and surface scaling
There is a considerable interest to investigate surface crystallization in order to have a full mechanistic understanding of how layers of sparingly soluble salts (scale) build on component surfaces. Despite much recent attention, a suitable methodology to improve on the understanding of the precipitation/deposition systems to enable the construction of an accurate surface deposition kinetic model is still needed. In this work, an experimental flow rig and associated methodology to study mineral scale deposition is developed. The once-through flow rig allows us to follow mineral scale precipitation and surface deposition in situ and in real time. The rig enables us to assess the effects of various parameters such as brine chemistry and scaling indices, temperature, flow rates, and scale inhibitor concentrations on scaling kinetics. Calcium carbonate (CaCO3) scaling at different values of the saturation ratio (SR) is evaluated using image analysis procedures that enable the assessment of surface coverage, nucleation, and growth of the particles with time. The result for turbidity values measured in the flow cell is zero for all the SR considered. The residence time from the mixing point to the sample is shorter than the induction time for bulk precipitation; therefore, there are no crystals in the bulk solution as the flow passes through the sample. The study shows that surface scaling is not always a result of pre-precipitated crystals in the bulk solution. The technique enables both precipitation and surface deposition of scale to be decoupled and for the surface deposition process to be studied in real time and assessed under constant condition.