Lakshmi Ananthakrishnan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lakshmi Ananthakrishnan has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
John R. Leyendecker
UT Southwestern Med Ctr, Dallas, TX USA
4 shared publications- Suhny Abbara
Department of Radiology, Mayo Clinic, Jacksonville, Fla
4 shared publications Matthew A. Lewis
UT Southwestern Med Ctr, Dallas, TX USA
3 shared publications- Yin Xi
Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
3 shared publications - Bari Dane
Department of Radiology, NYU Langone Health, New York, NY
2 shared publications - Fides Regina Schwartz
Department of Radiology, Brigham and Women’s Hospital, Boston, USA
2 shared publications
Latest Publications
- 27 July 2026
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (10) , 1960-1964
Implementing a Department-Wide Peer Learning Program Across a Large Academic Radiology Practice
- 27 July 2026
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (10) , 1960-1964
Implementing a Department-Wide Peer Learning Program Across a Large Academic Radiology Practice
- 14 March 2025
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 49 (2) , 168
Commentary: Foreword from the Guest Editor: Guest Section on Sustainability
- 14 March 2025
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 49 (2) , 168
Commentary: Foreword from the Guest Editor: Guest Section on Sustainability
- 1 February 2025
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 45 (2) , e240106
Getting Started with Photon-counting CT: Optimizing Your Setup for Success
Understanding the unique features of photon-counting CT and being familiar with terminology and setup processes are essential to effectively implement this modality in clinical practice.
- 1 February 2025
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 45 (2) , e240106
Getting Started with Photon-counting CT: Optimizing Your Setup for Success
Understanding the unique features of photon-counting CT and being familiar with terminology and setup processes are essential to effectively implement this modality in clinical practice.
- 25 July 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 49 (12) , 4600-4609
Photon counting CT clinical adoption, integration, and workflow
Photon counting CT was recently introduced into clinical practice [Rajendran K, Petersilka M, Henning A, Shanblatt ER, Schmidt B, Flohr TG, Ferrero A, Baffour F, Diehn FE, Yu L, Rajiah P, Fletcher JG, Leng S, McCollough CH. First Clinical Photon-counting Detector CT System: Technical Evaluation. Radiology 2022;303(1):130–138. doi: https://doi.org/10.1148/radiol.212579]. Photon counting detectors (PCD) afford better spatial resolution, radiation dose efficiency, and iodine contrast-to-noise than EID-CT [Leng S, Bruesewitz M, Tao S, Rajendran K, Halaweish AF, Campeau NG, Fletcher JG, McCollough CH. Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology. Radiographics 2019;39(3):729–743. doi: https://doi.org/10.1148/rg.2019180115); (Leng S, Rajendran K, Gong H, Zhou W, Halaweish AF, Henning A, Kappler S, Baer M, Fletcher JG, McCollough CH. 150-mum Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images. Invest Radiol 2018;53(11):655–662. doi: https://doi.org/10.1097/RLI.0000000000000488)(Booij R, van der Werf NR, Dijkshoorn ML, van der Lugt A, van Straten M. Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data. Diagnostics (Basel) 2022;12(6). doi: https://doi.org/10.3390/diagnostics12061467); (Sawall S, Klein L, Amato C, Wehrse E, Dorn S, Maier J, Heinze S, Schlemmer HP, Ziener CH, Uhrig M, Kachelriess M. Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT. Eur J Radiol 2020;126:108909. doi: https://doi.org/10.1016/j.ejrad.2020.108909] while also maintaining multienergy CT (MECT) capabilities[Flohr T, Petersilka M, Henning A, Ulzheimer S, Ferda J, Schmidt B. Photon-counting CT review. Phys Med 2020;79:126–136. doi: https://doi.org/10.1016/j.ejmp.2020.10.030]. This article will review the clinical adoption of PCD-CT including protocol development, clinical applications, clinical integration and workflow considerations. Protocol development is institution specific and involves collaborative decision-making among radiologists, physicists, and technologists. Key PCD clinical applications include radiation exposure reduction, intravenous contrast volume reduction, and improved lesion conspicuity. Patients who would most benefit from these improvements may preferentially be scanned with PCD CT. With numerous available reconstructions, radiologists should be strategic in the series sent to PACS for interpretation and routinely sending spectral series to PACS can facilitate integration with clinical workflow. The Society of Abdominal Radiology PCD Emerging Technology Commission endorsed this article.
- 25 July 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 49 (12) , 4600-4609
Photon counting CT clinical adoption, integration, and workflow
Photon counting CT was recently introduced into clinical practice [Rajendran K, Petersilka M, Henning A, Shanblatt ER, Schmidt B, Flohr TG, Ferrero A, Baffour F, Diehn FE, Yu L, Rajiah P, Fletcher JG, Leng S, McCollough CH. First Clinical Photon-counting Detector CT System: Technical Evaluation. Radiology 2022;303(1):130–138. doi: https://doi.org/10.1148/radiol.212579]. Photon counting detectors (PCD) afford better spatial resolution, radiation dose efficiency, and iodine contrast-to-noise than EID-CT [Leng S, Bruesewitz M, Tao S, Rajendran K, Halaweish AF, Campeau NG, Fletcher JG, McCollough CH. Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology. Radiographics 2019;39(3):729–743. doi: https://doi.org/10.1148/rg.2019180115); (Leng S, Rajendran K, Gong H, Zhou W, Halaweish AF, Henning A, Kappler S, Baer M, Fletcher JG, McCollough CH. 150-mum Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images. Invest Radiol 2018;53(11):655–662. doi: https://doi.org/10.1097/RLI.0000000000000488)(Booij R, van der Werf NR, Dijkshoorn ML, van der Lugt A, van Straten M. Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data. Diagnostics (Basel) 2022;12(6). doi: https://doi.org/10.3390/diagnostics12061467); (Sawall S, Klein L, Amato C, Wehrse E, Dorn S, Maier J, Heinze S, Schlemmer HP, Ziener CH, Uhrig M, Kachelriess M. Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT. Eur J Radiol 2020;126:108909. doi: https://doi.org/10.1016/j.ejrad.2020.108909] while also maintaining multienergy CT (MECT) capabilities[Flohr T, Petersilka M, Henning A, Ulzheimer S, Ferda J, Schmidt B. Photon-counting CT review. Phys Med 2020;79:126–136. doi: https://doi.org/10.1016/j.ejmp.2020.10.030]. This article will review the clinical adoption of PCD-CT including protocol development, clinical applications, clinical integration and workflow considerations. Protocol development is institution specific and involves collaborative decision-making among radiologists, physicists, and technologists. Key PCD clinical applications include radiation exposure reduction, intravenous contrast volume reduction, and improved lesion conspicuity. Patients who would most benefit from these improvements may preferentially be scanned with PCD CT. With numerous available reconstructions, radiologists should be strategic in the series sent to PACS for interpretation and routinely sending spectral series to PACS can facilitate integration with clinical workflow. The Society of Abdominal Radiology PCD Emerging Technology Commission endorsed this article.
- 18 June 2023
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 61 (6) , 963-971
Dual-Energy CT
- 18 June 2023
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 61 (6) , 963-971
Dual-Energy CT
- 1 May 2023
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 43 (5) , e230001
Invited Commentary: Photon-counting CT: Embracing the Change
- 1 May 2023
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 43 (5) , e230001
Invited Commentary: Photon-counting CT: Embracing the Change
- 1 June 2022
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 4 (3) , e220101
What the Baby Formula and Medical Contrast Material Shortages Have in Common: Insights and Recommendations for Managing the Iodinated Contrast Media Shortage
This report discusses the COVID-19 pandemic related shortages in supply of iodinated contrast media and other commodities and their effect on the health system's ability to deliver excellent patien... The impact of supply chain and supply chain logistics, including personnel directly and indirectly related to the movement of supplies, has come to light in a variety of industries since the global...
- 1 June 2022
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 4 (3) , e220101
What the Baby Formula and Medical Contrast Material Shortages Have in Common: Insights and Recommendations for Managing the Iodinated Contrast Media Shortage
This report discusses the COVID-19 pandemic related shortages in supply of iodinated contrast media and other commodities and their effect on the health system's ability to deliver excellent patien... The impact of supply chain and supply chain logistics, including personnel directly and indirectly related to the movement of supplies, has come to light in a variety of industries since the global...
- 1 July 2021
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 18 (7) , 982-989
Fidelity of Electronic Documentation for Reactions Prompting Premedication to Iodinated Contrast Media
- 1 July 2021
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 18 (7) , 982-989
Fidelity of Electronic Documentation for Reactions Prompting Premedication to Iodinated Contrast Media
- 1 November 2018
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 42 (6) , 959-964
Phantom Validation of Spectral Detector Computed Tomography–Derived Virtual Monoenergetic, Virtual Noncontrast, and Iodine Quantification Images
Spectral detector computed tomography (SDCT) is a new CT technology that uses a dual-layer detector to perform energy separation. We aim to assess 3 clinical concepts using a phantom model: noise profile across the virtual monoenergetic (VME) spectrum, accuracy of iodine quantification, and virtual noncontrast (VNC) reconstructions' ability to remove iodine contribution to attenuation. Six vials containing varying concentrations of iodinated contrast (0–6 mg/mL) diluted in water were placed in a water bath and scanned on an SDCT scanner. Virtual monoenergetic (40–200 keV at 10-keV increments), iodine–no-water, and VNC reconstructions were created. Attenuation (in Hounsfield units [HU]), VME noise at each energy level, CT-derived iodine concentration, and VNC attenuation were recorded. Virtual monoenergetic noise was improved at all energies compared with conventional images (conventional, 9.8–11.2; VME, 7.5–9.5). Noise profile showed a slightly higher image noise at 40 keV, but was otherwise relatively flat across the energy spectrum. On iodine–no-water reconstructions, measured varied from actual iodine concentration by ±0.1 mg/mL (SD, 0.16–0.36). Virtual noncontrast attenuation was within 5 HU of water attenuation at all iodine concentrations. Reconstructions of SDCT show lower VME image noise, accurate iodine quantification, and VNC attenuation values within 5 HU of expected in a phantom model.
- 1 November 2018
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 42 (6) , 959-964
Phantom Validation of Spectral Detector Computed Tomography–Derived Virtual Monoenergetic, Virtual Noncontrast, and Iodine Quantification Images
Spectral detector computed tomography (SDCT) is a new CT technology that uses a dual-layer detector to perform energy separation. We aim to assess 3 clinical concepts using a phantom model: noise profile across the virtual monoenergetic (VME) spectrum, accuracy of iodine quantification, and virtual noncontrast (VNC) reconstructions' ability to remove iodine contribution to attenuation. Six vials containing varying concentrations of iodinated contrast (0–6 mg/mL) diluted in water were placed in a water bath and scanned on an SDCT scanner. Virtual monoenergetic (40–200 keV at 10-keV increments), iodine–no-water, and VNC reconstructions were created. Attenuation (in Hounsfield units [HU]), VME noise at each energy level, CT-derived iodine concentration, and VNC attenuation were recorded. Virtual monoenergetic noise was improved at all energies compared with conventional images (conventional, 9.8–11.2; VME, 7.5–9.5). Noise profile showed a slightly higher image noise at 40 keV, but was otherwise relatively flat across the energy spectrum. On iodine–no-water reconstructions, measured varied from actual iodine concentration by ±0.1 mg/mL (SD, 0.16–0.36). Virtual noncontrast attenuation was within 5 HU of water attenuation at all iodine concentrations. Reconstructions of SDCT show lower VME image noise, accurate iodine quantification, and VNC attenuation values within 5 HU of expected in a phantom model.