Gilberto C. Vaz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gilberto C. Vaz has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Domingos Xavier Viegas
Association for the Development of Industrial Aerodynamics, Forest Fire Research Center, University of Coimbra, Coimbra, Portugal
4 shared publications - Aldina Santiago
ISISE—Institute for Sustainability and Innovation in Structural, Department of Civil Engineering, University of Coimbra, 3030-788 Coimbra, Portugal
2 shared publications - António Manuel Gameiro Lopes
Department of Mechanical Engineering, University of Coimbra, ADAI, Rua Luís Reis Santos, Pólo II, 3030-788 Coimbra, Portugal
2 shared publications Jorge C. André
2 shared publications- Jorge C. S. André
ADAI, Department of Mechanical Engineering, University of Coimbra, Rua Luís Reis Santos, Pólo II, 3030-788 Coimbra, Portugal
2 shared publications - Jose Baranda Ribeiro
ADAI, Department of Mechanical Engineering, University of Coimbra, Rua Luís Reis Santos, Pólo II, 3030-788 Coimbra, Portugal
2 shared publications
Latest Publications
- Open Access
Rigid Protection System of Infrastructures against Forest Fires
The destruction caused by forest fires generates social impacts, environmental impacts, and extremely important economic impacts caused by the destruction of a wide range of infrastructures and essential goods. Therefore, as it is impossible to remove all the infrastructures from the forest and wildland–urban interface, the design of protection systems is essential. The main objective of this work is the development of a low-cost protection system, with rigid panels, requiring a simple installation, in order to protect outdoor infrastructures such as telecommunications stations, shelters, roadside enclosures, power cabinets, and other structures. A study was carried out on panels that could be used for protection in order to determine whether the protective material would be more appropriate. Taking into account the fire resistance behavior, thermal and structural properties and cost, the panels selected were the magnesium oxide fiberglass reinforced. The protection was constructed, installed on a telecommunication cabinet, and experimentally laboratory tested in a wind combustion tunnel. To collect the data InfraRed and video cameras, heat flux sensors, and thermocouples were used to determine the fire propagation, heat flux, and temperatures, respectively. The experimental data show that the low-cost protection is effective for protecting telecommunication cabinets and similar infrastructures against forest fires.
Open AccessRigid Protection System of Infrastructures against Forest Fires
The destruction caused by forest fires generates social impacts, environmental impacts, and extremely important economic impacts caused by the destruction of a wide range of infrastructures and essential goods. Therefore, as it is impossible to remove all the infrastructures from the forest and wildland–urban interface, the design of protection systems is essential. The main objective of this work is the development of a low-cost protection system, with rigid panels, requiring a simple installation, in order to protect outdoor infrastructures such as telecommunications stations, shelters, roadside enclosures, power cabinets, and other structures. A study was carried out on panels that could be used for protection in order to determine whether the protective material would be more appropriate. Taking into account the fire resistance behavior, thermal and structural properties and cost, the panels selected were the magnesium oxide fiberglass reinforced. The protection was constructed, installed on a telecommunication cabinet, and experimentally laboratory tested in a wind combustion tunnel. To collect the data InfraRed and video cameras, heat flux sensors, and thermocouples were used to determine the fire propagation, heat flux, and temperatures, respectively. The experimental data show that the low-cost protection is effective for protecting telecommunication cabinets and similar infrastructures against forest fires.
- 1 September 2018
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 92, 728-743
ORC based micro-cogeneration systems for residential application – A state of the art review and current challenges
- 1 September 2018
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 92, 728-743
ORC based micro-cogeneration systems for residential application – A state of the art review and current challenges
- Open Access
- 1 September 2017
- Published by Elsevier in Energy Procedia
- Vol. 129, 474-478
Development of a direct concept helical-coil evaporator for an ORC based micro-CHP system
- 1 September 2017
- Published by Elsevier in Energy Procedia
- Vol. 129, 474-478
Open AccessDevelopment of a direct concept helical-coil evaporator for an ORC based micro-CHP system
- 1 October 2015
- Published by Elsevier in Energy Conversion and Management
- Vol. 103, 991-1007
Ground source heat pumps as high efficient solutions for building space conditioning and for integration in smart grids
- 1 October 2015
- Published by Elsevier in Energy Conversion and Management
- Vol. 103, 991-1007
Ground source heat pumps as high efficient solutions for building space conditioning and for integration in smart grids
- 13 June 2013
- Published by CSIRO Publishing in International Journal of Wildland Fire
- Vol. 22 (7) , 970-979
Angular variation of fire rate of spread
Laboratory fire tests were performed in still air, for variable inclinations (10°, 15°) and fuel bed dimensions (1.28 × 2.50–3.0 × 4.6 m2), with homogeneous fuel beds of pine needles and pine wood excelsior. The fire ignition was made at a point, along a closed line with no fuel inside and along a straight edge of the fuel bed. The tests were recorded with an infrared camera and various techniques were developed to implement direct and indirect empirical methods of construction of the ‘orientation function’ of the fire in the given fuel bed and ambient conditions, showing how the rate of spread of a steady straight fire front depends on its orientation on the terrain. The direct method uses a set of straight fire fronts with various orientations whereas the indirect method uses essentially a point ignited fire front. Contrary to what is assumed in BehavePlus model, the orientation function is observed to depend significantly on the properties of the fuel bed. In all tests with closed fire fronts, the full steadiness required by the indirect method was not achieved (namely, at the head of the front), although, for slope angle of 10°, the corresponding errors induced on the orientation function were small.
- 13 June 2013
- Published by CSIRO Publishing in International Journal of Wildland Fire
- Vol. 22 (7) , 970-979
Angular variation of fire rate of spread
Laboratory fire tests were performed in still air, for variable inclinations (10°, 15°) and fuel bed dimensions (1.28 × 2.50–3.0 × 4.6 m2), with homogeneous fuel beds of pine needles and pine wood excelsior. The fire ignition was made at a point, along a closed line with no fuel inside and along a straight edge of the fuel bed. The tests were recorded with an infrared camera and various techniques were developed to implement direct and indirect empirical methods of construction of the ‘orientation function’ of the fire in the given fuel bed and ambient conditions, showing how the rate of spread of a steady straight fire front depends on its orientation on the terrain. The direct method uses a set of straight fire fronts with various orientations whereas the indirect method uses essentially a point ignited fire front. Contrary to what is assumed in BehavePlus model, the orientation function is observed to depend significantly on the properties of the fuel bed. In all tests with closed fire fronts, the full steadiness required by the indirect method was not achieved (namely, at the head of the front), although, for slope angle of 10°, the corresponding errors induced on the orientation function were small.
- 25 June 2008
- Published by Techno-Press in Steel and Composite Structures
- Vol. 8 (3) , 243-264
Experimental investigation of the behaviour of a steel sub-frame under a natural fire
- 25 June 2008
- Published by Techno-Press in Steel and Composite Structures
- Vol. 8 (3) , 243-264
Experimental investigation of the behaviour of a steel sub-frame under a natural fire
- 25 December 2005
- Published by Techno-Press in Steel and Composite Structures
- Vol. 5 (6) , 421-441
Numerical predictions of the time-dependent temperature field for the 7thCardington compartment fire test
- 25 December 2005
- Published by Techno-Press in Steel and Composite Structures
- Vol. 5 (6) , 421-441
Numerical predictions of the time-dependent temperature field for the 7thCardington compartment fire test
- 8 April 2004
- Published by CSIRO Publishing in International Journal of Wildland Fire
- Vol. 13 (1) , 65-71
Estimation of the radiation extinction coefficient of natural fuel beds
. The standard formula used to estimate the radiation extinction coefficient, kb (m–1), of solid porous natural fuel beds is examined and tested against laboratory experiments with isotropic beds of pine needles in the range of packing ratio, β, of 0.01–0.02. To measure kb in the tests, a setup using a parallel beam of white light radiation was constructed. The error of the standard formula is observed to be smaller than 10%. Similar tests were performed for a non-isotropic bed of pine needles with β ≈ 0.02, in which the maximum angle of inclination of the needles was limited to 30°, for two directions of incidence of radiation: horizontal and vertical. For each one of these two cases, original estimation formulae for kb are proposed alternative to the standard one. In these cases it is concluded that, while the standard formula may be in error by up to 20%, the new formulae have errors around 5% or smaller.
- 8 April 2004
- Published by CSIRO Publishing in International Journal of Wildland Fire
- Vol. 13 (1) , 65-71
Estimation of the radiation extinction coefficient of natural fuel beds
. The standard formula used to estimate the radiation extinction coefficient, kb (m–1), of solid porous natural fuel beds is examined and tested against laboratory experiments with isotropic beds of pine needles in the range of packing ratio, β, of 0.01–0.02. To measure kb in the tests, a setup using a parallel beam of white light radiation was constructed. The error of the standard formula is observed to be smaller than 10%. Similar tests were performed for a non-isotropic bed of pine needles with β ≈ 0.02, in which the maximum angle of inclination of the needles was limited to 30°, for two directions of incidence of radiation: horizontal and vertical. For each one of these two cases, original estimation formulae for kb are proposed alternative to the standard one. In these cases it is concluded that, while the standard formula may be in error by up to 20%, the new formulae have errors around 5% or smaller.
- 1 February 2004
- Published by Taylor & Francis in Combustion Science and Technology
- Vol. 176 (2) , 135-182
FIRE SPREAD MODEL FOR A LINEAR FRONT IN A HORIZONTAL SOLID POROUS FUEL BED IN STILL AIR
A semi-empirical model for a steady linear fire front propagating through a statistically homogeneous porous bed, for the basic case of no wind, no slope, and fine fuel particles, is presented. The model structure is modular, based on an open library of submodels for the relevant phenomena. The submodeling of moisture heat absorption and radiation is addressed in detail. Presently, the model is not closed; it requires two properties of the fire front as inputs. Various sensitivity analyses and parametrical studies are performed. A laboratory test in a bed of pine needles showed that the model predictions are very sensitive to the flame height estimation and that the empirical submodels available in the literature are not adequate. However, if the flame height is considered an input, the rate of spread and the profile of the leading edge of the front in the fuel bed are predicted within the experimental errors.
- 1 February 2004
- Published by Taylor & Francis in Combustion Science and Technology
- Vol. 176 (2) , 135-182
FIRE SPREAD MODEL FOR A LINEAR FRONT IN A HORIZONTAL SOLID POROUS FUEL BED IN STILL AIR
A semi-empirical model for a steady linear fire front propagating through a statistically homogeneous porous bed, for the basic case of no wind, no slope, and fine fuel particles, is presented. The model structure is modular, based on an open library of submodels for the relevant phenomena. The submodeling of moisture heat absorption and radiation is addressed in detail. Presently, the model is not closed; it requires two properties of the fire front as inputs. Various sensitivity analyses and parametrical studies are performed. A laboratory test in a bed of pine needles showed that the model predictions are very sensitive to the flame height estimation and that the empirical submodels available in the literature are not adequate. However, if the flame height is considered an input, the rate of spread and the profile of the leading edge of the front in the fuel bed are predicted within the experimental errors.