Nghia Tran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nghia Tran has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jean E. Piou
Lexington, Massachusetts United States
2 shared publications Aly E. Fathy
Department of Electrical Engineering and Computer Science, University of Tennessee, Knoxville, TN 37996 USA
1 shared publication- Aly E. Fathy
EECS Department, Univeristy of Tennessee
1 shared publication - Farhan Quaiyum
Electrical Engineering and Computer Science, University of Tennessee, 4285 Knoxville, Tennessee United States 37996
1 shared publication - Farnaz Foroughian
Department of Electrical Engineering and Computer Science, University of Tennessee, Knoxville, TN 37996 USA
1 shared publication - Krishna Naishadham
School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
1 shared publication
Latest Publications
- 14 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 3 (1) , 61-70
Noncontact Human Gait Analysis and Limb Joint Tracking Using Doppler Radar
A full understanding of normal motion from human limb joint trajectory tracking could be essential to develop and establish a scientific basis for correcting any abnormalities. Practicality of using continuous wave (CW) radars, being simple and low cost, has been successfully investigated for non-contact gait monitoring, but it is still challenging to identify the motions of different limb joints. Here, we investigate the feasibility of extending the 1-D block processing algorithm to distinctly track specific limb joints and discuss the advantages and limitations of the technique for CW radar. To establish a repeatable reference data, we run a full wave EM analysis on customized Boulic human model emulating specific video recorded body motions. Results based on measured data are in agreement with simulated ones for simple motions like swinging one hand or one leg only. The proposed technique is also successful in extracting lower body parts while the whole body is in motion, however it is still hard to clearly extract upper body parts like swinging hands.
- 14 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 3 (1) , 61-70
Noncontact Human Gait Analysis and Limb Joint Tracking Using Doppler Radar
A full understanding of normal motion from human limb joint trajectory tracking could be essential to develop and establish a scientific basis for correcting any abnormalities. Practicality of using continuous wave (CW) radars, being simple and low cost, has been successfully investigated for non-contact gait monitoring, but it is still challenging to identify the motions of different limb joints. Here, we investigate the feasibility of extending the 1-D block processing algorithm to distinctly track specific limb joints and discuss the advantages and limitations of the technique for CW radar. To establish a repeatable reference data, we run a full wave EM analysis on customized Boulic human model emulating specific video recorded body motions. Results based on measured data are in agreement with simulated ones for simple motions like swinging one hand or one leg only. The proposed technique is also successful in extracting lower body parts while the whole body is in motion, however it is still hard to clearly extract upper body parts like swinging hands.
- 8 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 66 (7) , 3521-3534
Short-Time State-Space Method for Micro-Doppler Identification of Walking Subject Using UWB Impulse Doppler Radar
In this paper, ultra-wideband (UWB) Doppler radar signatures from walking human subjects are processed with the state-space method (SSM) to analyze compressed radar echoes for the first time. A new mathematical model is proposed to detect the human walking strides using UWB radar, while micro-Doppler (μ-D) features are extracted for gait analysis using short-time SSM (STSSM). To distinguish μ-D signatures of different subjects' body parts, the SSM used for the characterization of radar target signatures and sensor fusion is applied on a sliding short-time window to enhance the resolution of feature extraction from data collected on a dismount. This method of the application of SSM to sliding short-time data is validated with a full-wave electromagnetic (EM) simulation of a walking subject using the Boulic model that represents the human kinematics. An EM scattering model is then utilized to compare the performance of a short-time Fourier transform with STSSM. Experimental results show that STSSM can be successfully applied to identify multiple μ-D trajectories in real experimental data, thus demonstrating the capability to positively identify human motions (right foot, left foot, and torso) even in a low signal-to-noise ratio environment.
- 8 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 66 (7) , 3521-3534
Short-Time State-Space Method for Micro-Doppler Identification of Walking Subject Using UWB Impulse Doppler Radar
In this paper, ultra-wideband (UWB) Doppler radar signatures from walking human subjects are processed with the state-space method (SSM) to analyze compressed radar echoes for the first time. A new mathematical model is proposed to detect the human walking strides using UWB radar, while micro-Doppler (μ-D) features are extracted for gait analysis using short-time SSM (STSSM). To distinguish μ-D signatures of different subjects' body parts, the SSM used for the characterization of radar target signatures and sensor fusion is applied on a sliding short-time window to enhance the resolution of feature extraction from data collected on a dismount. This method of the application of SSM to sliding short-time data is validated with a full-wave electromagnetic (EM) simulation of a walking subject using the Boulic model that represents the human kinematics. An EM scattering model is then utilized to compare the performance of a short-time Fourier transform with STSSM. Experimental results show that STSSM can be successfully applied to identify multiple μ-D trajectories in real experimental data, thus demonstrating the capability to positively identify human motions (right foot, left foot, and torso) even in a low signal-to-noise ratio environment.