S.S. Roziskulov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
S.S. Roziskulov has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Maksym A. Shcherba
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”, 37, Beresteiskyi Ave., Kyiv, 03056, Ukraine
5 shared publications - Nataliia Suprunovska
Institute of Electrodynamics National Academy of Sciences of Ukraine, 56, Beresteiskyi Ave., Kyiv, 03057, Ukraine
5 shared publications - Anatolii A. Shcherba
Institute of Electrodynamics of the National Academy of Sciences of Ukraine, Ukraine
2 shared publications - Julia Peretyatko
National Technical University of Ukraine Igor Sikorsky Kyiv Polytechnic Institute,Department of Theoretical Electrical Engineering,Kyiv,Ukraine
2 shared publications D.V. Vinnichenko
Institute of Electrodynamics National Academy of Sciences of Ukraine, Beresteiskyi Ave., 56, Kyiv, 03057, Ukraine
1 shared publicationI.I. Fedorchenko
National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute", 37, Beresteyskyi Ave., Kyiv, 03056, Ukraine
1 shared publication
Latest Publications
- Open Access
- 7 September 2026
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2026 (5) , 13-18
AMPLIFICATION OF ELECTROMECHANICAL STRESSES BETWEEN CLOSELY PLACED WATER MICRO-INCURRENTS IN THE INSULATION OF HIGH-VOLTAGE CABLES UNDER THE INFLUENCE OF AN ALTERNATING ELECTRIC FIELD
For crosslinked polyethylene insulation of high-voltage and ultra-high-voltage cables, a mathematical model of its electromechanical degradation near water micro-inclusions has been developed based on a combination of electrostatic and mechanical analysis. The finite element method has been used to simulate the distribution of field strength and Maxwell pressure near single defects of spherical and ellipsoidal shape, as well as pairs of closely located inclusions for 110 and 330 kV cables. It has been shown that the elongation of the defect along the field at a fixed maximum size of 50 μm increases the maximum field strength from 3 to 35 times, and the maximum Maxwell pressure in these cases is from 0.09 to 12.2 MPa, i.e. up to ~67% of the accepted tensile strength of crosslinked polyethylene. As a result of the study of the interaction of two closely spaced inclusions, it was found that the convergence of spherical defects at a distance of up to 2 μm increases the maximum pressure on the insulation to 2.82 MPa, and for elongated ellipsoids 50×8.3 μm at a mutual distance of 2 μm the maximum pressure reaches 34.9 MPa, which is almost twice the strength limit of the insulation. It is shown that the most critical for cable insulation are groups of closely spaced, elongated along the field of water micro-inclusions, near which local cyclic stresses due to field amplification become sufficient both for the instantaneous destruction of thin areas of the dielectric between the inclusions and for long-term fatigue damage to the insulation, which leads to the formation and growth of water triangulations even at permissible average electrical loads. References 10, figures 2.
- 7 September 2026
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2026 (5) , 13-18
Open AccessAMPLIFICATION OF ELECTROMECHANICAL STRESSES BETWEEN CLOSELY PLACED WATER MICRO-INCURRENTS IN THE INSULATION OF HIGH-VOLTAGE CABLES UNDER THE INFLUENCE OF AN ALTERNATING ELECTRIC FIELD
For crosslinked polyethylene insulation of high-voltage and ultra-high-voltage cables, a mathematical model of its electromechanical degradation near water micro-inclusions has been developed based on a combination of electrostatic and mechanical analysis. The finite element method has been used to simulate the distribution of field strength and Maxwell pressure near single defects of spherical and ellipsoidal shape, as well as pairs of closely located inclusions for 110 and 330 kV cables. It has been shown that the elongation of the defect along the field at a fixed maximum size of 50 μm increases the maximum field strength from 3 to 35 times, and the maximum Maxwell pressure in these cases is from 0.09 to 12.2 MPa, i.e. up to ~67% of the accepted tensile strength of crosslinked polyethylene. As a result of the study of the interaction of two closely spaced inclusions, it was found that the convergence of spherical defects at a distance of up to 2 μm increases the maximum pressure on the insulation to 2.82 MPa, and for elongated ellipsoids 50×8.3 μm at a mutual distance of 2 μm the maximum pressure reaches 34.9 MPa, which is almost twice the strength limit of the insulation. It is shown that the most critical for cable insulation are groups of closely spaced, elongated along the field of water micro-inclusions, near which local cyclic stresses due to field amplification become sufficient both for the instantaneous destruction of thin areas of the dielectric between the inclusions and for long-term fatigue damage to the insulation, which leads to the formation and growth of water triangulations even at permissible average electrical loads. References 10, figures 2.
- Open Access
- 28 April 2025
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2025 (3) , 3-10
INTERDEPENDENT TRANSIENT PROCESSES IN CIRCLES OF BIPOLAR DISCHARGE PULSE CURRENT GENERATOR WITH R-L-C LOAD AND LIMITED POSITIVE VOLTAGE FEEDBACK
The paper analyzes the interdependent transient processes in the discharge circuits of a bipolar discharge pulse gen-erator (DPG) with R-L-C load and limited positive voltage feedback. The analytical dependence of the value of the ini-tial voltage on the capacitor connected in series with the load on the value of the Q factor of the discharge circuit of the DPG was obtained. The optimal electrical parameters of these circuits have been determined to ensure high dynamic and energy indicators of impulse currents in an electric spark load. It is substantiated that the serial connection of a capacitor with an electric spark load in the discharge circuit of a bipolar DPG with a capacitive storage of electrical energy of high energy capacity allows to increase (maximum twice) the initial rate of current rise in the electric spark load of a bipolar DPG and significantly improve the energy indicators of discharge impulse currents. The short-circuit currents value of the DPG load is limited by the value of the characteristic resistance of the DPG discharge circuit, and their flow time corresponds to the self-oscillation period of the DPG discharge circuit in this mode of operation. At the same time, electrical energy is not dissipated in the discharge circuit of the DPG, but it is almost completely recovered to the capacitors on output of direct voltage formers. References 15, figures 6.
- 28 April 2025
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2025 (3) , 3-10
Open AccessINTERDEPENDENT TRANSIENT PROCESSES IN CIRCLES OF BIPOLAR DISCHARGE PULSE CURRENT GENERATOR WITH R-L-C LOAD AND LIMITED POSITIVE VOLTAGE FEEDBACK
The paper analyzes the interdependent transient processes in the discharge circuits of a bipolar discharge pulse gen-erator (DPG) with R-L-C load and limited positive voltage feedback. The analytical dependence of the value of the ini-tial voltage on the capacitor connected in series with the load on the value of the Q factor of the discharge circuit of the DPG was obtained. The optimal electrical parameters of these circuits have been determined to ensure high dynamic and energy indicators of impulse currents in an electric spark load. It is substantiated that the serial connection of a capacitor with an electric spark load in the discharge circuit of a bipolar DPG with a capacitive storage of electrical energy of high energy capacity allows to increase (maximum twice) the initial rate of current rise in the electric spark load of a bipolar DPG and significantly improve the energy indicators of discharge impulse currents. The short-circuit currents value of the DPG load is limited by the value of the characteristic resistance of the DPG discharge circuit, and their flow time corresponds to the self-oscillation period of the DPG discharge circuit in this mode of operation. At the same time, electrical energy is not dissipated in the discharge circuit of the DPG, but it is almost completely recovered to the capacitors on output of direct voltage formers. References 15, figures 6.
- Open Access
- 21 November 2022
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini
- Vol. 2022 (63) , 26-30
DEPENDENCE OF DYNAMIC CHARACTERISTICS OF PULSE CURRENTS OF ELECTRICAL DISCHARGE INSTALLATIONS ON THE DISTANCE OF THEIR TECHNOLOGICAL LOAD
The paper investigates the influence of the distant technological load from electric discharge installations (EDIs) with capacitive storage of electricity on the dynamic characteristics of impulse currents in the load. On the basis of experi-mental studies, the peculiarities of changing the dynamic characteristics of EDIs, such as the average rate of rise and fall of their output pulse current during the implementation of volumetric spark dispersion of a layer of metal granules in dielectric liquids between electrodes, were determined. The influence of the length of such types of connecting con-ductors as twisted pair, coaxial cable, and litzendraht with bifilar winding of current-carrying conductors on the output dynamic characteristics of the EDI was analyzed. A significant influence of the type of connecting conductors of con-siderable length on the indicated characteristics has been established, especially in the case of a low-inductance of the load circuit of the EDI. It is substantiated that when the technological load is significantly distant (several meters) from the EDI, it is quite appropriate to use power cables with solid polymer electrical insulation as connecting conductors of the coaxial type. Ref. 10, fig. 2, tables 2.
- 21 November 2022
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini
- Vol. 2022 (63) , 26-30
Open AccessDEPENDENCE OF DYNAMIC CHARACTERISTICS OF PULSE CURRENTS OF ELECTRICAL DISCHARGE INSTALLATIONS ON THE DISTANCE OF THEIR TECHNOLOGICAL LOAD
The paper investigates the influence of the distant technological load from electric discharge installations (EDIs) with capacitive storage of electricity on the dynamic characteristics of impulse currents in the load. On the basis of experi-mental studies, the peculiarities of changing the dynamic characteristics of EDIs, such as the average rate of rise and fall of their output pulse current during the implementation of volumetric spark dispersion of a layer of metal granules in dielectric liquids between electrodes, were determined. The influence of the length of such types of connecting con-ductors as twisted pair, coaxial cable, and litzendraht with bifilar winding of current-carrying conductors on the output dynamic characteristics of the EDI was analyzed. A significant influence of the type of connecting conductors of con-siderable length on the indicated characteristics has been established, especially in the case of a low-inductance of the load circuit of the EDI. It is substantiated that when the technological load is significantly distant (several meters) from the EDI, it is quite appropriate to use power cables with solid polymer electrical insulation as connecting conductors of the coaxial type. Ref. 10, fig. 2, tables 2.
- Open Access
- 23 May 2022
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2022 (3) , 16-21
IMPROVING THE DYNAMIC CHARACTERISTICS OF ELECTRIC DISCHARGE INSTALLATIONS, WHICH ARE SIGNIFICANTLY DISTANT FROM THE SPARK-EROSION LOAD
The paper identifies the features of the influence of the characteristics of different connecting conductors on the dynamic characteristics of electric discharge installations (EDIs), which are distant significantly (several meters) from the spark-erosion load. In the electric spark production of dispersed powders, such a load is the interelectrode gap (IEG) in the technological dispersion apparatus (TAD), filled with a layer of metal granules and a low-conductive (preferably dielectric) flowing liquid. The influence of the design parameters of such long connecting conductors as twisted pair, litzendraht with bifilar winding of conductors and coaxial cable on the dynamic characteristics of the indicated EDIs (including on the average rates of rise and fall of the discharge pulse current) is experimentally investigated. It is substantiated that the use of power coaxial cables with modern cross-linked polymer electrical insulation is practically the most expedient for connection of significantly distant TAD under the condition of insignificant (up to 0.5 μH) self-inductance of EDIs. References 11, figures 4, tables 3.
- 23 May 2022
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2022 (3) , 16-21
Open AccessIMPROVING THE DYNAMIC CHARACTERISTICS OF ELECTRIC DISCHARGE INSTALLATIONS, WHICH ARE SIGNIFICANTLY DISTANT FROM THE SPARK-EROSION LOAD
The paper identifies the features of the influence of the characteristics of different connecting conductors on the dynamic characteristics of electric discharge installations (EDIs), which are distant significantly (several meters) from the spark-erosion load. In the electric spark production of dispersed powders, such a load is the interelectrode gap (IEG) in the technological dispersion apparatus (TAD), filled with a layer of metal granules and a low-conductive (preferably dielectric) flowing liquid. The influence of the design parameters of such long connecting conductors as twisted pair, litzendraht with bifilar winding of conductors and coaxial cable on the dynamic characteristics of the indicated EDIs (including on the average rates of rise and fall of the discharge pulse current) is experimentally investigated. It is substantiated that the use of power coaxial cables with modern cross-linked polymer electrical insulation is practically the most expedient for connection of significantly distant TAD under the condition of insignificant (up to 0.5 μH) self-inductance of EDIs. References 11, figures 4, tables 3.
- Open Access
- 19 April 2021
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2021 (3) , 3-9
REGULATION OF OUTPUT DYNAMIC CHARACTERISTICS OF ELECTRIC DISCHARGE INSTALLATIONS WITH RESERVOIR CAPACITORS
The paper reveals the dependences of the output dynamic characteristics of semiconductor electric discharge installations (EDIs) with reservoir capacitors on the features of the change in the value of their capacitance. In particular, it is substantiated that for any fixed discharge duration less than the duration of reaching the maximum discharge current, an increase in the capacitance of such storage devices causes an increase in the value of the final discharge current both at aperiodic and oscillatory discharges in the linear resistance of the technological load. The change in the value of the discharge current in the load in the case of forced interruption of this current at a certain moment of time is investigated. Based on the obtained regularities, the authors of the work proposed to use the capacitance of the EDI's capacitor, which is larger than capacitance required to implement the maximum value of the discharge current in the load. Using a capacitor with a larger capacity and a fully controlled semiconductor switch in the discharge circuit of the EDI, it is possible to obtain the required maximum current value at a shorter duration of the discharge process. Thus, it is possible to regulate the main dynamic parameters of pulse currents in the load – the rate of their rise and/or their duration by changing the value of the capacitance of the discharge capacitor EDI. This approach is expedient for increasing the productivity of EDIs, focused on the production of dispersed spark powders of metals and alloys. References 15, figures 3.
- 19 April 2021
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2021 (3) , 3-9
Open AccessREGULATION OF OUTPUT DYNAMIC CHARACTERISTICS OF ELECTRIC DISCHARGE INSTALLATIONS WITH RESERVOIR CAPACITORS
The paper reveals the dependences of the output dynamic characteristics of semiconductor electric discharge installations (EDIs) with reservoir capacitors on the features of the change in the value of their capacitance. In particular, it is substantiated that for any fixed discharge duration less than the duration of reaching the maximum discharge current, an increase in the capacitance of such storage devices causes an increase in the value of the final discharge current both at aperiodic and oscillatory discharges in the linear resistance of the technological load. The change in the value of the discharge current in the load in the case of forced interruption of this current at a certain moment of time is investigated. Based on the obtained regularities, the authors of the work proposed to use the capacitance of the EDI's capacitor, which is larger than capacitance required to implement the maximum value of the discharge current in the load. Using a capacitor with a larger capacity and a fully controlled semiconductor switch in the discharge circuit of the EDI, it is possible to obtain the required maximum current value at a shorter duration of the discharge process. Thus, it is possible to regulate the main dynamic parameters of pulse currents in the load – the rate of their rise and/or their duration by changing the value of the capacitance of the discharge capacitor EDI. This approach is expedient for increasing the productivity of EDIs, focused on the production of dispersed spark powders of metals and alloys. References 15, figures 3.
- Open Access
- 26 June 2020
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2020 (4) , 15-18
DECREASE OF TRANSIENTS DURATION AND IMPROVEMENT OF DYNAMIC CHARACTERISTICS OF ELECTRICAL DISCHARGE INSTALLATIONS BY CHANGING THE STRUCTURE OF THEIR DISCHARGE CIRCUIT
Joomla! - the dynamic portal engine and content management system
- 26 June 2020
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2020 (4) , 15-18
Open AccessDECREASE OF TRANSIENTS DURATION AND IMPROVEMENT OF DYNAMIC CHARACTERISTICS OF ELECTRICAL DISCHARGE INSTALLATIONS BY CHANGING THE STRUCTURE OF THEIR DISCHARGE CIRCUIT
Joomla! - the dynamic portal engine and content management system
- 28 August 2019
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini
- No. 53,p. 75-79
TRANSIENT PROCESSES IN ELECTRIC CIRCUITS OF SEMICONDUCTOR CONVERTERS WITH NINE ZONED REGULATION OF VOLTAGE ON ELECTROTECHNOLOGICAL LOAD
Інститут електродинаміки Національної академії наук України
- 28 August 2019
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini
- No. 53,p. 75-79
TRANSIENT PROCESSES IN ELECTRIC CIRCUITS OF SEMICONDUCTOR CONVERTERS WITH NINE ZONED REGULATION OF VOLTAGE ON ELECTROTECHNOLOGICAL LOAD
Інститут електродинаміки Національної академії наук України