Mitsushi Abe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mitsushi Abe has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Ken-Ichi Sasaki
High Energy Accelerator Research Organization, J-PARC center, Tokai-mura, Japan
8 shared publications - Tsutomu Mibe
High Energy Accelerator Research Organization (KEK)
7 shared publications - Hiromi Iinuma
Ibaraki University
6 shared publications - Naohito Saito
University of Tokyo
4 shared publications H. Nakayama
High Energy Accelerator Research Organization (KEK), Tsukuba, Japan
3 shared publications- Toru Ogitsu
High Energy Accelerator Research Organization (KEK), Tsukuba, Japan
3 shared publications
Latest Publications
- Open Access
- 14 March 2025
- Published by Springer Nature in The European Physical Journal D
- Vol. 79 (3) , 1-15
Precision measurements of muonium and muonic helium hyperfine structure at J-PARC
At the J-PARC Muon Science Facility (MUSE), the MuSEUM collaboration is now performing new precision measurements of the ground state hyperfine structure (HFS) of both muonium and muonic helium atoms. High-precision measurements of the muonium ground-state HFS are recognized as one of the most sensitive tools for testing bound-state quantum electrodynamics theory to precisely probe the standard model and determine fundamental constants of the positive muon magnetic moment and mass. The same technique can also be employed to measure muonic helium HFS, obtain the negative muon magnetic moment and mass, and test and improve the theory of the three-body atomic system. Measurements at zero magnetic field have already yielded more accurate results than previous experiments for both muonium and muonic helium atoms. High-field measurements are now ready to start collecting data using the world’s most intense pulsed muon beam at the MUSE H-line. We aim to improve the precision of previous measurements ten times for muonium and a hundred times or more for muonic helium. We review all the key developments for these new measurements, focusing on the high-field experiment, and report the latest results and prospects.
- 14 March 2025
- Published by Springer Nature in The European Physical Journal D
- Vol. 79 (3) , 1-15
Open AccessPrecision measurements of muonium and muonic helium hyperfine structure at J-PARC
At the J-PARC Muon Science Facility (MUSE), the MuSEUM collaboration is now performing new precision measurements of the ground state hyperfine structure (HFS) of both muonium and muonic helium atoms. High-precision measurements of the muonium ground-state HFS are recognized as one of the most sensitive tools for testing bound-state quantum electrodynamics theory to precisely probe the standard model and determine fundamental constants of the positive muon magnetic moment and mass. The same technique can also be employed to measure muonic helium HFS, obtain the negative muon magnetic moment and mass, and test and improve the theory of the three-body atomic system. Measurements at zero magnetic field have already yielded more accurate results than previous experiments for both muonium and muonic helium atoms. High-field measurements are now ready to start collecting data using the world’s most intense pulsed muon beam at the MUSE H-line. We aim to improve the precision of previous measurements ten times for muonium and a hundred times or more for muonic helium. We review all the key developments for these new measurements, focusing on the high-field experiment, and report the latest results and prospects.
- Open Access
- 20 May 2023
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 58 (3) , 132-139
TSVDシミング計算とMRI磁石を用いた超良好一様(±0.1 ppm)磁場実現のシミング試験
Two muon experiments, which require extremely homogeneous magnetic fields, are under preparations in J-PARC. One of the experiments is the MuSEUM(Muonium Spectroscopy Experiment Using Microwave)experiment that requires+/-0.1 ppm homogeneity in a spheroidal volume of 20 cm in diameter and 30 cm in length. To confirm that such an extremely homogeneous magnetic field can be obtained in a whole-body MRI magnet, intensive shimming tests were conducted using a shimming calculation based on TSVD of linear algebra with a passive shimming structure. In the first shimming test, we found that small shim-piece unit is necessary, and in the second test an extremely homogeneous magnetic field was realized with Ni shim plates, the magnetic moment of which is 1/6 of the ordinal Fe shim plates of MRI magnetic field. This result confirms that an extremely homogeneous magnetic field can be realized for the experiment.
- 20 May 2023
- Published by Cryogenic Association of Japan in Teion Kogaku (Journal of Cryogenics and Superconductivity Society of Japan)
- Vol. 58 (3) , 132-139
Open AccessTSVDシミング計算とMRI磁石を用いた超良好一様(±0.1 ppm)磁場実現のシミング試験
Two muon experiments, which require extremely homogeneous magnetic fields, are under preparations in J-PARC. One of the experiments is the MuSEUM(Muonium Spectroscopy Experiment Using Microwave)experiment that requires+/-0.1 ppm homogeneity in a spheroidal volume of 20 cm in diameter and 30 cm in length. To confirm that such an extremely homogeneous magnetic field can be obtained in a whole-body MRI magnet, intensive shimming tests were conducted using a shimming calculation based on TSVD of linear algebra with a passive shimming structure. In the first shimming test, we found that small shim-piece unit is necessary, and in the second test an extremely homogeneous magnetic field was realized with Ni shim plates, the magnetic moment of which is 1/6 of the ordinal Fe shim plates of MRI magnetic field. This result confirms that an extremely homogeneous magnetic field can be realized for the experiment.
- 5 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design Optimization of Combined Function Accelerator Magnet Using Truncated Singular Value Decomposition
The Japan Proton Accelerator Research Complex (J-PARC) is a world-class accelerator facility for particle and nuclear physics experiments such as the rare kaon decays experiment (KOTO), the T2K long-baseline neutrino experiment, and future projects such as COMET. A new stretcher ring (SR) comprising a combined function superconducting magnet is proposed to run all of the facilities at the same time, which can improve beam efficiency and increase operating time. In order to achieve the field quality requirements on the magnet aperture, it is critical to identify an optimum pole shape. Dipole, quadrupole, and sextupole fields are required for the combined function magnet. To find the best design parameters for this analysis, we employed singular value decomposition. The singular value decomposition (SVD) technique resulted in a solution to the desired parameters and a quick process to obtain a 2D pole profile.
- 5 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design Optimization of Combined Function Accelerator Magnet Using Truncated Singular Value Decomposition
The Japan Proton Accelerator Research Complex (J-PARC) is a world-class accelerator facility for particle and nuclear physics experiments such as the rare kaon decays experiment (KOTO), the T2K long-baseline neutrino experiment, and future projects such as COMET. A new stretcher ring (SR) comprising a combined function superconducting magnet is proposed to run all of the facilities at the same time, which can improve beam efficiency and increase operating time. In order to achieve the field quality requirements on the magnet aperture, it is critical to identify an optimum pole shape. Dipole, quadrupole, and sextupole fields are required for the combined function magnet. To find the best design parameters for this analysis, we employed singular value decomposition. The singular value decomposition (SVD) technique resulted in a solution to the desired parameters and a quick process to obtain a 2D pole profile.
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design of the Superconducting Magnet System for the New $g-2$/EDM Experiment in the J-PARC
A superconducting solenoid system has been designed for the $g$ -2/EDM experiment at the J-PARC, which is used to store muon beam of 0.3 GeV/c. High homogeneous magnetic field is required to be below $\pm$ 0.1 ppm at 3 T within a muon storage region of 33.3 $\pm$ 1.5 cm in radius and $\mathbf {\pm }$ 5 cm in height around the magnet center. The muon beam is spirally injected to the storage region from the top end of the magnet, therefore the magnetic field distribution is carefully designed in the region where the muon beam pass through. In order to achieve both requirements, NbTi superconducting coils are surrounded by an iron yoke with pole tips, which can optimize the field distribution by adjusting the shape and size. The superconducting coils are cooled by pool boiling in liquid helium, and the evaporated helium gas is re-condensed by GM cryocoolers to keep the liquid helium level for a long time. The main coils are operated in a persistent current mode to remove the magnetic field fluctuation with time caused by a power supply. This paper presents the current design of the magnet system for the experiment at the J-PARC.
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Design of the Superconducting Magnet System for the New $g-2$/EDM Experiment in the J-PARC
A superconducting solenoid system has been designed for the $g$ -2/EDM experiment at the J-PARC, which is used to store muon beam of 0.3 GeV/c. High homogeneous magnetic field is required to be below $\pm$ 0.1 ppm at 3 T within a muon storage region of 33.3 $\pm$ 1.5 cm in radius and $\mathbf {\pm }$ 5 cm in height around the magnet center. The muon beam is spirally injected to the storage region from the top end of the magnet, therefore the magnetic field distribution is carefully designed in the region where the muon beam pass through. In order to achieve both requirements, NbTi superconducting coils are surrounded by an iron yoke with pole tips, which can optimize the field distribution by adjusting the shape and size. The superconducting coils are cooled by pool boiling in liquid helium, and the evaporated helium gas is re-condensed by GM cryocoolers to keep the liquid helium level for a long time. The main coils are operated in a persistent current mode to remove the magnetic field fluctuation with time caused by a power supply. This paper presents the current design of the magnet system for the experiment at the J-PARC.
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Study of Vibration Effect on Magnetic Field Homogeneity in the Magnet System for the $g-2$/EDM Experiment at the J-PARC
In a superconducting solenoid used as the muon storage magnet in the J-PARC $g-2$ /EDM experiment, high homogeneous magnetic field of less than $\mathbf {\pm }$ 0.1 ppm at 3 T is required. A study on source of magnetic field disturbance is much important to achieve such high homogeneous magnetic field, and a vibration is one of the serious concerns in terms of dynamic error source of magnetic field. Two vibration sources were considered, a seismic vibration and GM cryocoolers. A frequency response analysis was carried out in the magnet system to evaluate the magnitude of the vibration of magnet using ANSYS. The analysis results shows that the displacement of main coil due to a seismic vibration at J-PARC would be about 0.69 and 0.43 $\boldsymbol{\mu }$ m in the horizontal and vertical direction at maximum, respectively. The coil vibration caused by GM cryocoolers was calculated to be negligible, less than 1 $\mathbf {\times }$ $\mathbf {10^{-3}}$ $\boldsymbol{\mu }$ m, thanks to the vibration isolation design of a cold box and a liquid helium transfer tube. The evaluated magnetic field error due to the cryocooler vibration was less than $\pm$ 1 $\mathbf {\times }$ $\mathbf {10^{-4}}$ ppm, which was much smaller than the requirement of $\pm$ 0.1 ppm. On the other hand, the magnetic field error due to the coil displacement was evaluated to be $\pm$ 0.043 and $\pm$ 0.008 ppm in the horizontal and vertical directions, these were not negligibly small compared with the requirement, especially in the horizontal direction. In order to reduce the vibration conducted through the ground, the vibration dumping system is planned to be implemented in the practical magnet system.
- 2 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Study of Vibration Effect on Magnetic Field Homogeneity in the Magnet System for the $g-2$/EDM Experiment at the J-PARC
In a superconducting solenoid used as the muon storage magnet in the J-PARC $g-2$ /EDM experiment, high homogeneous magnetic field of less than $\mathbf {\pm }$ 0.1 ppm at 3 T is required. A study on source of magnetic field disturbance is much important to achieve such high homogeneous magnetic field, and a vibration is one of the serious concerns in terms of dynamic error source of magnetic field. Two vibration sources were considered, a seismic vibration and GM cryocoolers. A frequency response analysis was carried out in the magnet system to evaluate the magnitude of the vibration of magnet using ANSYS. The analysis results shows that the displacement of main coil due to a seismic vibration at J-PARC would be about 0.69 and 0.43 $\boldsymbol{\mu }$ m in the horizontal and vertical direction at maximum, respectively. The coil vibration caused by GM cryocoolers was calculated to be negligible, less than 1 $\mathbf {\times }$ $\mathbf {10^{-3}}$ $\boldsymbol{\mu }$ m, thanks to the vibration isolation design of a cold box and a liquid helium transfer tube. The evaluated magnetic field error due to the cryocooler vibration was less than $\pm$ 1 $\mathbf {\times }$ $\mathbf {10^{-4}}$ ppm, which was much smaller than the requirement of $\pm$ 0.1 ppm. On the other hand, the magnetic field error due to the coil displacement was evaluated to be $\pm$ 0.043 and $\pm$ 0.008 ppm in the horizontal and vertical directions, these were not negligibly small compared with the requirement, especially in the horizontal direction. In order to reduce the vibration conducted through the ground, the vibration dumping system is planned to be implemented in the practical magnet system.
- 8 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Evaluation of the Magnetic Field Error Due to Manufacturing Tolerance of Superconducting Magnet for the J-PARC Muon $g-2$/EDM Experiment
The J-PARC Muon $g-2$ /EDM Experiment uses a superconducting solenoid magnet to store positive muons, which generates a magnetic field of $3 \,\rm {T}$ . A highly uniform magnetic field is required, which is less than $0.2 \,\mathrm{ppm_{p-p}}$ (peak-to-peak) in a muon storage region of $(333\pm 15)\,\mathrm{mm}$ in radius and $\pm 50 \,\mathrm{mm}$ in height around the magnet center. The magnetic field error due to manufacturing tolerance was evaluated with a Monte Carlo simulation. This paper introduces the evaluation of magnetic field error due to manufacturing tolerance with a Monte Carlo simulation implemented in C++17. Assuming tolerance to be within $0.1\,\mathrm{mm}$ or $0.1$ mrad, the uniformity was calculated to be $179 \,\mathrm{ppm_{p-p}}$ at the worst case. We performed shimming simulation by using truncated singular value decomposition regularization. As a result, it was confirmed that the worst field error could be compensated to the uniformity of $0.17 \,\mathrm{ppm_{p-p}}$ with a present shimming system. Furthermore, we performed the shimming simulation for wider range of the manufacturing tolerances to investigate the shimming system limit. We concluded that the magnet had to be manufactured with an accuracy less than at least $0.5\,\mathrm{mm}$ or $0.5$ mrad.
- 8 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Evaluation of the Magnetic Field Error Due to Manufacturing Tolerance of Superconducting Magnet for the J-PARC Muon $g-2$/EDM Experiment
The J-PARC Muon $g-2$ /EDM Experiment uses a superconducting solenoid magnet to store positive muons, which generates a magnetic field of $3 \,\rm {T}$ . A highly uniform magnetic field is required, which is less than $0.2 \,\mathrm{ppm_{p-p}}$ (peak-to-peak) in a muon storage region of $(333\pm 15)\,\mathrm{mm}$ in radius and $\pm 50 \,\mathrm{mm}$ in height around the magnet center. The magnetic field error due to manufacturing tolerance was evaluated with a Monte Carlo simulation. This paper introduces the evaluation of magnetic field error due to manufacturing tolerance with a Monte Carlo simulation implemented in C++17. Assuming tolerance to be within $0.1\,\mathrm{mm}$ or $0.1$ mrad, the uniformity was calculated to be $179 \,\mathrm{ppm_{p-p}}$ at the worst case. We performed shimming simulation by using truncated singular value decomposition regularization. As a result, it was confirmed that the worst field error could be compensated to the uniformity of $0.17 \,\mathrm{ppm_{p-p}}$ with a present shimming system. Furthermore, we performed the shimming simulation for wider range of the manufacturing tolerances to investigate the shimming system limit. We concluded that the magnet had to be manufactured with an accuracy less than at least $0.5\,\mathrm{mm}$ or $0.5$ mrad.
- 20 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-7
Development of Precise Shimming Technique With Materials Having Low Saturation Magnetization
Magnetic field shimming using low saturation magnetization material was tested to realize spatial magnetic field homogeneity of less than 1 ppm. The magnetic moment per unit mass were measured for three candidates, that is, Nickel, magnetic fluid and magnetic putty, and it was verified that those have low magnetic moments suitable for precise shimming below 1 ppm. The magnetic shimming test was performed using MRI magnet for MuSEUM experiment at 1.2 T with iron plates, Ni thin plates and magnetic putty. The magnetic shimming with iron plates was conducted employing the two step shimming scheme, and the homogeneity could be reached to 0.29 ppm peak-to-peak (ppm $_\text{pp}$ ) after six shimming trials. Then, the precise shimming was carried out with Ni thin plates and magnetic putty, and the homogeneity could be reached to 0.16 ppm peak-to-peak with Nickel and 0.17 ppm $_\text{pp}$ with magnetic putty. No deformation of putty in the magnetic field was observed even after two months. The magnetic field monitoring for two months showed that magnetic field strength and homogeneity largely depended on the temperature, and the temperature of the magnet room has to be controlled within $\pm$ 0.35 degC under the circumference condition of the shimming test in order to keep the magnetic field change and the homogeneity within $\pm$ 0.1 ppm. In addition, it is showed that the refilling of LHe in the MuSEUM magnet system should be performed once per 29 days The practical implementation method for magnetic putty was suggested for the existing magnet system by using plastic spacers with holes.
- 20 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-7
Development of Precise Shimming Technique With Materials Having Low Saturation Magnetization
Magnetic field shimming using low saturation magnetization material was tested to realize spatial magnetic field homogeneity of less than 1 ppm. The magnetic moment per unit mass were measured for three candidates, that is, Nickel, magnetic fluid and magnetic putty, and it was verified that those have low magnetic moments suitable for precise shimming below 1 ppm. The magnetic shimming test was performed using MRI magnet for MuSEUM experiment at 1.2 T with iron plates, Ni thin plates and magnetic putty. The magnetic shimming with iron plates was conducted employing the two step shimming scheme, and the homogeneity could be reached to 0.29 ppm peak-to-peak (ppm $_\text{pp}$ ) after six shimming trials. Then, the precise shimming was carried out with Ni thin plates and magnetic putty, and the homogeneity could be reached to 0.16 ppm peak-to-peak with Nickel and 0.17 ppm $_\text{pp}$ with magnetic putty. No deformation of putty in the magnetic field was observed even after two months. The magnetic field monitoring for two months showed that magnetic field strength and homogeneity largely depended on the temperature, and the temperature of the magnet room has to be controlled within $\pm$ 0.35 degC under the circumference condition of the shimming test in order to keep the magnetic field change and the homogeneity within $\pm$ 0.1 ppm. In addition, it is showed that the refilling of LHe in the MuSEUM magnet system should be performed once per 29 days The practical implementation method for magnetic putty was suggested for the existing magnet system by using plastic spacers with holes.
- 13 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Design Method of Active Shield Steering Magnet for Fine Tuning of Muon Injection Orbit Into g-2/EDM Precision Measurements Magnet
This study is about a design method for ASSMs (Active Shield Steering Magnets). ASSMs will be applied to a g-2/EDM precise measurements experiment which is under preparation in J-PARC. The experiment needs a very homogeneous 3.0 T magnetic field using a superconducting magnet with iron yoke. Muons are injected through spiral orbits in the fringe field and two ASSMs are planned for orbit fine tuning. ASSMs need to generate steering magnetic fields without additional error field. Then, they need active shields, and they are ASSMs. For such ASSMs, a design method has been developed and trial design have been done, using a technique of the MRI GC design method which can well determine 3D current pattern on surfaces.
- 13 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Design Method of Active Shield Steering Magnet for Fine Tuning of Muon Injection Orbit Into g-2/EDM Precision Measurements Magnet
This study is about a design method for ASSMs (Active Shield Steering Magnets). ASSMs will be applied to a g-2/EDM precise measurements experiment which is under preparation in J-PARC. The experiment needs a very homogeneous 3.0 T magnetic field using a superconducting magnet with iron yoke. Muons are injected through spiral orbits in the fringe field and two ASSMs are planned for orbit fine tuning. ASSMs need to generate steering magnetic fields without additional error field. Then, they need active shields, and they are ASSMs. For such ASSMs, a design method has been developed and trial design have been done, using a technique of the MRI GC design method which can well determine 3D current pattern on surfaces.
- 5 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-4
Developments of a Pulse Kicker System for the Three-Dimensional Spiral Beam Injection of the J-PARC Muon g-2/EDM Experiment
The development of a vertical kicker system is an important part of a three-dimensional spiral-injection scheme. The beam injected at a pitch angle of a few tens of degrees was controlled by applying a pulsed magnetic field using a vertical kicker system inside the storage magnet. The stored muon beam then followed a vertical betatron motion around the midplane of the storage magnet owing to the weak focusing magnetic field. Accurate control of the pulsed kick is crucial for minimizing the amplitude of the vertical betatron oscillation. The specifications of the pulsed magnetic field and detailed design of the kicker system at the test beam bench are discussed herein.
- 5 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-4
Developments of a Pulse Kicker System for the Three-Dimensional Spiral Beam Injection of the J-PARC Muon g-2/EDM Experiment
The development of a vertical kicker system is an important part of a three-dimensional spiral-injection scheme. The beam injected at a pitch angle of a few tens of degrees was controlled by applying a pulsed magnetic field using a vertical kicker system inside the storage magnet. The stored muon beam then followed a vertical betatron motion around the midplane of the storage magnet owing to the weak focusing magnetic field. Accurate control of the pulsed kick is crucial for minimizing the amplitude of the vertical betatron oscillation. The specifications of the pulsed magnetic field and detailed design of the kicker system at the test beam bench are discussed herein.
- 23 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Design of a Strong X-Y Coupling Beam Transport Line for J-PARC Muon g-2/EDM Experiment
A strategy to design of a dedicated beam transport line for J-PARC Muon g-2/EDM experiment is described. To accomplish three-dimensional beam injection into the MRI-type compact storage ling, transverse beam phase spaces (X and Y components) should be coupled appropriately. We introduce a X-Y coupling, extended Twiss-parameters, and transfer-matrix of the entire transport line. We also discuss about detailed parameters of rotating quadruple magnets along the transport line.
- 23 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Design of a Strong X-Y Coupling Beam Transport Line for J-PARC Muon g-2/EDM Experiment
A strategy to design of a dedicated beam transport line for J-PARC Muon g-2/EDM experiment is described. To accomplish three-dimensional beam injection into the MRI-type compact storage ling, transverse beam phase spaces (X and Y components) should be coupled appropriately. We introduce a X-Y coupling, extended Twiss-parameters, and transfer-matrix of the entire transport line. We also discuss about detailed parameters of rotating quadruple magnets along the transport line.