Development of Precise Shimming Technique With Materials Having Low Saturation Magnetization
- 20 July 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-7
Abstract
Magnetic field shimming using low saturation magnetization material was tested to realize spatial magnetic field homogeneity of less than 1 ppm. The magnetic moment per unit mass were measured for three candidates, that is, Nickel, magnetic fluid and magnetic putty, and it was verified that those have low magnetic moments suitable for precise shimming below 1 ppm. The magnetic shimming test was performed using MRI magnet for MuSEUM experiment at 1.2 T with iron plates, Ni thin plates and magnetic putty. The magnetic shimming with iron plates was conducted employing the two step shimming scheme, and the homogeneity could be reached to 0.29 ppm peak-to-peak (ppm $_\text{pp}$ ) after six shimming trials. Then, the precise shimming was carried out with Ni thin plates and magnetic putty, and the homogeneity could be reached to 0.16 ppm peak-to-peak with Nickel and 0.17 ppm $_\text{pp}$ with magnetic putty. No deformation of putty in the magnetic field was observed even after two months. The magnetic field monitoring for two months showed that magnetic field strength and homogeneity largely depended on the temperature, and the temperature of the magnet room has to be controlled within $\pm$ 0.35 degC under the circumference condition of the shimming test in order to keep the magnetic field change and the homogeneity within $\pm$ 0.1 ppm. In addition, it is showed that the refilling of LHe in the MuSEUM magnet system should be performed once per 29 days The practical implementation method for magnetic putty was suggested for the existing magnet system by using plastic spacers with holes.Keywords
Funding Information
- JSPS KAKENHI (18H01239)
This publication has 10 references indexed in Scilit:
- A new approach for measuring the muon anomalous magnetic moment and electric dipole momentProgress of Theoretical and Experimental Physics, 2019
- Development of a CW-NMR Probe for Precise Measurement of Absolute Magnetic FieldIEEE Transactions on Applied Superconductivity, 2019
- New precise measurements of muonium hyperfine structure at J-PARC MUSEEPJ Web of Conferences, 2019
- Passive Shimming of MRI Static Magnetic Field Using Regularization of Truncated Singular Value DecompositionMagnetic Resonance in Medical Sciences, 2017
- A design tool for magnetic resonance imaging gradient coils using DUCAS with weighted nodes and initial current potentialsIEEE Transactions on Magnetics, 2013
- A novel precision measurement of muon g - 2 and EDM at J-PARCAIP Conference Proceedings, 2012
- The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kindsMedical Physics, 1996
- Passive shimming of the superconducting magnet for MRIIEEE Transactions on Applied Superconductivity, 1995
- The magnetization of pure iron and nickelProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1971
- Demagnetizing Factors of the General EllipsoidPhysical Review B, 1945