Roberto Freire da Mota Albuquerque
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Roberto Freire da Mota Albuquerque has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Gilberto Luis Camanho
Departamento de Ortopedia e Traumatologia, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brasil
12 shared publications José Ricardo Pécora
Knee Surgery Division, Department of Orthopedics and Traumatology, University of São Paulo, Rua Dr. Ovídio Pires de Campos, 333, Cerqueira Cesar, São Paulo, SP, CEP 05403-010, Brazil
11 shared publications- Fabio Janson Angelini
University of São Paulo
10 shared publications - Camilo Partezani Helito
Grupo de Joelho, Instituto de Ortopedia e Traumatologia, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de São Paulo, São Paulo, Brazil
9 shared publications - Marco Kawamura Demange
Instituto de Ortopedia e Traumatologia, Hospital das Clinicas, Faculdade de Medicina, Universidade de Sao Paulo-HCFMUSP, Sao Paulo 05403-010, Brazil
9 shared publications Marco Martins Amatuzzi
Department of Orthopaedics University of São Paulo São Paulo Brazil
8 shared publications
Latest Publications
- Open Access
Mechanical evaluation of tibial fixation of the hamstring tendon in anterior cruciate ligament double-bundle reconstruction with and without interference screws
The objective of this study was to compare two postero-lateral bundle (PLB) tibial fixation techniques for the reconstruction of the anterior cruciate ligament with double bundle: a technique without the use of an interference screw, preserving the native tibial insertion of the tendons of the gracilis and semitendineous muscles, and a technique with the use of an interference screw and without preserving the insertion of the tendons. A comparative study was conducted in cadavers with a universal mechanical test machine. In total, 23 cadaver knees were randomized for tibial fixation of the PLB using the two techniques: Maintaining the tibial insertion of the tendons during reconstruction, without the use of an interference screw (group A, 11 cases); and fixating the graft with an interference screw, without maintaining the insertion of the tendons (group B, 12 cases). A continuous traction was performed (20 mm/min) in the same direction as the produced tunnel, and force (N), elongation (mm), rigidity (N/mm), and tension (N/mm2) were objectively determined in each group. Group A exhibited a maximum force (MF) of 315.4±124.7 N; maximum tension of 13.57±3.65 N/mm2; maximum elongation of 19.73±4.76 mm; force at the limit of proportionality (FLP) of 240.6±144.0 N; and an elongation at the limit of proportionality of 14.37±6.58 mm. Group B exhibited a MF of 195.7±71.8 N; maximum tension of 8.8±3.81 N/mm2; maximum elongation of 15.3±10.73 mm; FLP of 150.1±68.7 N; and an elongation at the limit of proportionality of 6.86±2.42 mm. When comparing the two groups, significant differences were observed in the variables of maximum force (p=0.016), maximum tension (p=0.019), maximum elongation (p=0.007), and elongation at the limit of proportionality (p=0.003). The use of the native insertion of the semitendineous and gracilis tendons, without an additional fixation device, presented mechanical superiority over their fixation with interference screws.
Open AccessMechanical evaluation of tibial fixation of the hamstring tendon in anterior cruciate ligament double-bundle reconstruction with and without interference screws
The objective of this study was to compare two postero-lateral bundle (PLB) tibial fixation techniques for the reconstruction of the anterior cruciate ligament with double bundle: a technique without the use of an interference screw, preserving the native tibial insertion of the tendons of the gracilis and semitendineous muscles, and a technique with the use of an interference screw and without preserving the insertion of the tendons. A comparative study was conducted in cadavers with a universal mechanical test machine. In total, 23 cadaver knees were randomized for tibial fixation of the PLB using the two techniques: Maintaining the tibial insertion of the tendons during reconstruction, without the use of an interference screw (group A, 11 cases); and fixating the graft with an interference screw, without maintaining the insertion of the tendons (group B, 12 cases). A continuous traction was performed (20 mm/min) in the same direction as the produced tunnel, and force (N), elongation (mm), rigidity (N/mm), and tension (N/mm2) were objectively determined in each group. Group A exhibited a maximum force (MF) of 315.4±124.7 N; maximum tension of 13.57±3.65 N/mm2; maximum elongation of 19.73±4.76 mm; force at the limit of proportionality (FLP) of 240.6±144.0 N; and an elongation at the limit of proportionality of 14.37±6.58 mm. Group B exhibited a MF of 195.7±71.8 N; maximum tension of 8.8±3.81 N/mm2; maximum elongation of 15.3±10.73 mm; FLP of 150.1±68.7 N; and an elongation at the limit of proportionality of 6.86±2.42 mm. When comparing the two groups, significant differences were observed in the variables of maximum force (p=0.016), maximum tension (p=0.019), maximum elongation (p=0.007), and elongation at the limit of proportionality (p=0.003). The use of the native insertion of the semitendineous and gracilis tendons, without an additional fixation device, presented mechanical superiority over their fixation with interference screws.
- 20 August 2015
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 23 (10) , 3012-3018
External fixator for treatment of the sub-acute and chronic multi-ligament-injured knee
To assess whether the use of an articulated external fixator provides improvements in the mobility, stability and subjective function of patients undergoing ligament reconstruction. Thirty-three patients with sub-acute and chronic knee dislocation were subjected to multi-ligament reconstruction surgery. These patients were randomly allocated to two groups for immobilization after reconstruction: group 0—control (18 patients), with rigid knee bracing, and group 1—articulated external fixator (15 patients). The stability of the reconstructed ligaments was assessed after at least 14 months (26.6-month average) postoperatively by physical examination. Deficit of extension and flexion was measured in relation to the unaffected contralateral knee, and the Lysholm knee scoring scale questionnaire was applied. There was no difference in the assessment of joint stability between the groups. In group 1, patients showed less flexion deficit (4.8° ± 5.4° vs. 18.2° ± 14.8°, p < 0.05), and the percentage of patients with a flexion deficit of 5° or less were higher compared with group 0 (64 vs. 18 %, p < 0.05). There was no difference between groups in relation to extension loss. Group 1 also presented better Lysholm scores, with 73 % of patients rated as excellent or good compared with 35 % in group 0 (p < 0.05). Compared with the control rehabilitation protocol with rigid knee bracing in extension, the use of an articulated external fixator in the treatment of chronic multi-ligament-injured knees provided the same ligament stability, better final range of motion and improved Lysholm score. Patients presenting with chronic multi-ligament instability should be considered for articulated external fixation to supplement reconstruction procedures. Randomized controlled trial, Level I.
- 20 August 2015
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 23 (10) , 3012-3018
External fixator for treatment of the sub-acute and chronic multi-ligament-injured knee
To assess whether the use of an articulated external fixator provides improvements in the mobility, stability and subjective function of patients undergoing ligament reconstruction. Thirty-three patients with sub-acute and chronic knee dislocation were subjected to multi-ligament reconstruction surgery. These patients were randomly allocated to two groups for immobilization after reconstruction: group 0—control (18 patients), with rigid knee bracing, and group 1—articulated external fixator (15 patients). The stability of the reconstructed ligaments was assessed after at least 14 months (26.6-month average) postoperatively by physical examination. Deficit of extension and flexion was measured in relation to the unaffected contralateral knee, and the Lysholm knee scoring scale questionnaire was applied. There was no difference in the assessment of joint stability between the groups. In group 1, patients showed less flexion deficit (4.8° ± 5.4° vs. 18.2° ± 14.8°, p < 0.05), and the percentage of patients with a flexion deficit of 5° or less were higher compared with group 0 (64 vs. 18 %, p < 0.05). There was no difference between groups in relation to extension loss. Group 1 also presented better Lysholm scores, with 73 % of patients rated as excellent or good compared with 35 % in group 0 (p < 0.05). Compared with the control rehabilitation protocol with rigid knee bracing in extension, the use of an articulated external fixator in the treatment of chronic multi-ligament-injured knees provided the same ligament stability, better final range of motion and improved Lysholm score. Patients presenting with chronic multi-ligament instability should be considered for articulated external fixation to supplement reconstruction procedures. Randomized controlled trial, Level I.
- 6 August 2015
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 38 (2) , 223-228
The meniscal insertion of the knee anterolateral ligament
The aim of this study is to characterize in detail the meniscal insertion of the anterolateral ligament (ALL) of the knee, establishing parameters regarding the circumference of the lateral meniscus and the popliteal muscle tendon (PMT) groove in addition to its histological analysis. A total of 33 knees of cadavers were dissected. The ALL and the lateral meniscus were removed en bloc. After removal of the anatomical specimen, the meniscus circumference, the ALL insertion points on the external surface of the lateral meniscus, and the PMT groove were measured. Eight menisci were subjected to histological analysis. The ALL was found in all dissections performed. The ALL insertion occurred macroscopically in the transition between the anterior horn and the lateral meniscus body, specifically beginning at 36.0 % and ending at 41.9 % of the meniscal circumference, occupying a mean area of 5.6 mm. The distance between the end of the ALL meniscal insertion and the beginning of the PMT groove averaged 12.9 mm. In the histological evaluation, in longitudinal sections, we observed dense collagen fibers of the ligament inserting on the external surface of the meniscus. It is possible to observe a spreading of collagen fibers at the moment of meniscal insertion. The ALL meniscal insertion was found in all dissected specimens, beginning with approximately 36 % of the meniscal outer diameter, 12.9 mm anterior to the beginning of the PMT groove. The histological analysis confirmed the presence of true ligamentous tissue in the dissected specimens.
- 6 August 2015
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 38 (2) , 223-228
The meniscal insertion of the knee anterolateral ligament
The aim of this study is to characterize in detail the meniscal insertion of the anterolateral ligament (ALL) of the knee, establishing parameters regarding the circumference of the lateral meniscus and the popliteal muscle tendon (PMT) groove in addition to its histological analysis. A total of 33 knees of cadavers were dissected. The ALL and the lateral meniscus were removed en bloc. After removal of the anatomical specimen, the meniscus circumference, the ALL insertion points on the external surface of the lateral meniscus, and the PMT groove were measured. Eight menisci were subjected to histological analysis. The ALL was found in all dissections performed. The ALL insertion occurred macroscopically in the transition between the anterior horn and the lateral meniscus body, specifically beginning at 36.0 % and ending at 41.9 % of the meniscal circumference, occupying a mean area of 5.6 mm. The distance between the end of the ALL meniscal insertion and the beginning of the PMT groove averaged 12.9 mm. In the histological evaluation, in longitudinal sections, we observed dense collagen fibers of the ligament inserting on the external surface of the meniscus. It is possible to observe a spreading of collagen fibers at the moment of meniscal insertion. The ALL meniscal insertion was found in all dissected specimens, beginning with approximately 36 % of the meniscal outer diameter, 12.9 mm anterior to the beginning of the PMT groove. The histological analysis confirmed the presence of true ligamentous tissue in the dissected specimens.
- 12 July 2015
- Published by Springer Nature in International Orthopaedics
- Vol. 40 (4) , 821-825
Is it safe to reconstruct the knee Anterolateral Ligament with a femoral tunnel? Frequency of Lateral Collateral Ligament and Popliteus Tendon injury
This study sought to determine the safety limits for performing a femoral bone tunnel to reconstruct the knee anterolateral ligament (ALL) by establishing its distance from the lateral collateral ligament (LCL) and the popliteus muscle tendon (PT) on the lateral femoral condyle. Anatomic study on 48 knee cadaveric specimens. The femoral attachments of the studied structures were isolated, and the distance between them was measured. For each cadaver, the percentage of cases in which at least 50 % of the LCL and PT would be injured when using 4- to 12-mm-diameter drills in an ALL reconstruction procedure was evaluated. The LCL and PT were 3.8 mm and 10.2 mm distant from the ALL, respectively. A 4-mm tunnel would cause LCL injury in 8.3 % of cases, with increasing incidence of injury up to 87.5 % with a 12-mm drill. Injury to the PT would start with the 10-mm drill, causing injury in 2.0 % of cases. Performing a tunnel in the center of the ALL may cause an iatrogenic injury to the LCL origin. No cases of PT injury are expected to occur with drills smaller than 10 mm.
- 12 July 2015
- Published by Springer Nature in International Orthopaedics
- Vol. 40 (4) , 821-825
Is it safe to reconstruct the knee Anterolateral Ligament with a femoral tunnel? Frequency of Lateral Collateral Ligament and Popliteus Tendon injury
This study sought to determine the safety limits for performing a femoral bone tunnel to reconstruct the knee anterolateral ligament (ALL) by establishing its distance from the lateral collateral ligament (LCL) and the popliteus muscle tendon (PT) on the lateral femoral condyle. Anatomic study on 48 knee cadaveric specimens. The femoral attachments of the studied structures were isolated, and the distance between them was measured. For each cadaver, the percentage of cases in which at least 50 % of the LCL and PT would be injured when using 4- to 12-mm-diameter drills in an ALL reconstruction procedure was evaluated. The LCL and PT were 3.8 mm and 10.2 mm distant from the ALL, respectively. A 4-mm tunnel would cause LCL injury in 8.3 % of cases, with increasing incidence of injury up to 87.5 % with a 12-mm drill. Injury to the PT would start with the 10-mm drill, causing injury in 2.0 % of cases. Performing a tunnel in the center of the ALL may cause an iatrogenic injury to the LCL origin. No cases of PT injury are expected to occur with drills smaller than 10 mm.
- Open Access
- 1 June 2015
- Published by Wiley in Arthroscopy Techniques
- Vol. 4 (3) , e239-44
Combined Intra‐ and Extra‐articular Reconstruction of the Anterior Cruciate Ligament: The Reconstruction of the Knee Anterolateral Ligament
We present a new technique for the combined intra‐ and extra‐articular reconstruction of the anterior cruciate ligament. Intra‐articular reconstruction is performed in an outside‐in manner according to the precepts of the anatomic femoral tunnel technique. Extra‐articular reconstruction is performed with the gracilis tendon while respecting the anatomic parameters of the origin and insertion points and the path described for the knee anterolateral ligament. Technique Video: video See video under supplementary data.
- 1 June 2015
- Published by Wiley in Arthroscopy Techniques
- Vol. 4 (3) , e239-44
Open AccessCombined Intra‐ and Extra‐articular Reconstruction of the Anterior Cruciate Ligament: The Reconstruction of the Knee Anterolateral Ligament
We present a new technique for the combined intra‐ and extra‐articular reconstruction of the anterior cruciate ligament. Intra‐articular reconstruction is performed in an outside‐in manner according to the precepts of the anatomic femoral tunnel technique. Extra‐articular reconstruction is performed with the gracilis tendon while respecting the anatomic parameters of the origin and insertion points and the path described for the knee anterolateral ligament. Technique Video: video See video under supplementary data.
- 1 February 2015
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 101 (1) , 77-81
Surgical management of knee dislocations with ligament reconstruction associated with a hinged external fixator
- 1 February 2015
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 101 (1) , 77-81
Surgical management of knee dislocations with ligament reconstruction associated with a hinged external fixator
- 7 November 2014
- Published by Springer Nature in International Orthopaedics
- Vol. 39 (3) , 543-548
Functional assessment of combined reconstruction of the anterior cruciate ligament and posterolateral corner with a single femoral tunnel: a two-year minimum follow-up
A technique for combined reconstruction of the anterior cruciate ligament (ACL) and posterolateral corner (PLC) with a single femoral tunnel was recently described. This technique aims to avoid tunnel confluence in the lateral femoral condyle. Because there have been no studies on the functional outcomes and possible complications of this technique, our goal is to demonstrate a two-year minimum follow-up of patients who underwent this type of reconstruction. Nine patients were prospectively evaluated. The ACL was reconstructed with an anatomic single bundle, and the PLC structures reconstructed were the lateral collateral ligament, the popliteus tendon, and the popliteofibular ligament. Patients were evaluated using the objective and subjective International Knee Documentation Committee (IKDC) and the Lysholm and Tegner scales before and after the surgical procedure. The mean follow-up period of the studied patients was 27.3 months. The mean subjective IKDC score rose from 43.6 to 84.0, and the Lysholm score rose from 62.1 to 90.8. In the final assessment, six patients were classified as IKDC A and three as IKDC B. According to the Tegner scale, five patients were able to return to their level of activity prior to the injury. There were no reconstruction failures. One patient experienced postoperative infection and pain in the lateral scar. The results of the reconstruction of ACL injuries associated with PLC with a single femoral tunnel produced a good functional outcome and a low incidence of complications.
- 7 November 2014
- Published by Springer Nature in International Orthopaedics
- Vol. 39 (3) , 543-548
Functional assessment of combined reconstruction of the anterior cruciate ligament and posterolateral corner with a single femoral tunnel: a two-year minimum follow-up
A technique for combined reconstruction of the anterior cruciate ligament (ACL) and posterolateral corner (PLC) with a single femoral tunnel was recently described. This technique aims to avoid tunnel confluence in the lateral femoral condyle. Because there have been no studies on the functional outcomes and possible complications of this technique, our goal is to demonstrate a two-year minimum follow-up of patients who underwent this type of reconstruction. Nine patients were prospectively evaluated. The ACL was reconstructed with an anatomic single bundle, and the PLC structures reconstructed were the lateral collateral ligament, the popliteus tendon, and the popliteofibular ligament. Patients were evaluated using the objective and subjective International Knee Documentation Committee (IKDC) and the Lysholm and Tegner scales before and after the surgical procedure. The mean follow-up period of the studied patients was 27.3 months. The mean subjective IKDC score rose from 43.6 to 84.0, and the Lysholm score rose from 62.1 to 90.8. In the final assessment, six patients were classified as IKDC A and three as IKDC B. According to the Tegner scale, five patients were able to return to their level of activity prior to the injury. There were no reconstruction failures. One patient experienced postoperative infection and pain in the lateral scar. The results of the reconstruction of ACL injuries associated with PLC with a single femoral tunnel produced a good functional outcome and a low incidence of complications.
- Open Access
Effect of postoperative use of nasal oxygen catheter supplementation in wound healing following total knee arthroplasty
Healing is an event that is fundamental to the success of total knee arthroplasty. The aims of the present study were to compare the rates of complications related to wound healing between two groups of volunteers submitted to total knee arthroplasty and to evaluate the effects of postoperative oxygen supplementation by means of a nasal catheter. A total of 109 patients who underwent total knee arthroplasty were randomized into two groups, namely, groups that did and did not receive postoperative oxygen supplementation via a nasal catheter. The surgical wound was monitored every day during the hospital stay and on the 7th, 14th, 21st, 30th and 42nd postoperative days. Characteristics related to healing were observed, including hyperemia, dehiscence, necrosis, phlyctenules and deep and superficial infection. There were no cases of deep infection. Hyperemia was statistically correlated with the total number of complications in the groups, with oxygen demonstrated to be a protective factor against hyperemia. Approximately 30% of the patients who exhibited hyperemia had other complications, independent of oxygen supplementation. Oxygen supplementation following total knee arthroplasty was shown to be effective in diminishing hyperemia around the operative wound. The development of hyperemia was a precursor to other complications, irrespective of whether oxygen supplementation was used.
Open AccessEffect of postoperative use of nasal oxygen catheter supplementation in wound healing following total knee arthroplasty
Healing is an event that is fundamental to the success of total knee arthroplasty. The aims of the present study were to compare the rates of complications related to wound healing between two groups of volunteers submitted to total knee arthroplasty and to evaluate the effects of postoperative oxygen supplementation by means of a nasal catheter. A total of 109 patients who underwent total knee arthroplasty were randomized into two groups, namely, groups that did and did not receive postoperative oxygen supplementation via a nasal catheter. The surgical wound was monitored every day during the hospital stay and on the 7th, 14th, 21st, 30th and 42nd postoperative days. Characteristics related to healing were observed, including hyperemia, dehiscence, necrosis, phlyctenules and deep and superficial infection. There were no cases of deep infection. Hyperemia was statistically correlated with the total number of complications in the groups, with oxygen demonstrated to be a protective factor against hyperemia. Approximately 30% of the patients who exhibited hyperemia had other complications, independent of oxygen supplementation. Oxygen supplementation following total knee arthroplasty was shown to be effective in diminishing hyperemia around the operative wound. The development of hyperemia was a precursor to other complications, irrespective of whether oxygen supplementation was used.