Glyn Taylor
Research Subjects
Glyn Taylor has a total of 165 co-authors. Here are the top co-authors by number of shared publications:
- Mark Gumbleton
School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff, United Kingdom
10 shared publications I.W. Kellaway
Welsh School of Pharmacy, University of Wales, Cardiff CF1 3XF , UK
7 shared publicationsI. W. Kellaway
Welsh School of Pharmacy, University of Wales, Cardiff, CF1 3XF, UK
4 shared publicationsIan W. Kellaway
Welsh School of Pharmacy, University of Wales, Cathays Park, Cardiff CF1 3XF, UK
4 shared publications- Paul A. Dickinson
The Welsh School of Pharmacy, Cardiff University, Cathays Park, Cardiff CF10 3XF, UK
4 shared publications Simon Warren
Cardiff Scintigraphics Ltd., Cardiff, United Kingdom
4 shared publications
Latest Publications
- 1 September 2016
- Published by European Respiratory Society (ERS)
- Vol. 48 (suppl 60) , OA4834
LATE-BREAKING ABSTRACT: Pulmonary deposition of a novel LAMA/LABA Co-Suspension™ technology glycopyrronium/formoterol (GFF) MDI in healthy subjects (PT003020)
Background GFF MDI showed efficacy in Phase III trials of patients with moderate-to-very-severe COPD. Lung deposition and the regions where it occurs may relate to specific receptor activation and aerosol performance. We evaluated pulmonary deposition of radiolabelled GFF delivered by Co-Suspension™ Technology MDI (porous particles). Methods In this Phase I, randomized, single-blind, single-dose, single-centre, placebo-controlled study, healthy male subjects (n=10) received two inhalations of 99mTc-pertechnetate (≤10MBq) radiolabelled GFF 14.4/9.6μg or placebo (porous particles only) in a crossover design with a ≥5-day washout. In vitro analyses showed that aerosol delivery was unaltered by radiolabel application. Gamma counts of the lungs, stomach, oropharynx, mouthwash and exhalation filter were determined. Results Radioactivity detected in the various regions (Table 1) showed deposition in both central and peripheral regions, with very low exhaled fraction. Deposition was similar between GFF MDI and placebo MDI. One treatment-related adverse event occurred with GFF MDI and one with placebo MDI; neither were serious. Conclusion Both GFF and placebo MDI Co-Suspension™ formulations were efficiently deposited in the lungs with similar regional deposition patterns. The variability observed among subjects was typical of inhalation studies.
- 1 September 2016
- Published by European Respiratory Society (ERS)
- Vol. 48 (suppl 60) , OA4834
LATE-BREAKING ABSTRACT: Pulmonary deposition of a novel LAMA/LABA Co-Suspension™ technology glycopyrronium/formoterol (GFF) MDI in healthy subjects (PT003020)
Background GFF MDI showed efficacy in Phase III trials of patients with moderate-to-very-severe COPD. Lung deposition and the regions where it occurs may relate to specific receptor activation and aerosol performance. We evaluated pulmonary deposition of radiolabelled GFF delivered by Co-Suspension™ Technology MDI (porous particles). Methods In this Phase I, randomized, single-blind, single-dose, single-centre, placebo-controlled study, healthy male subjects (n=10) received two inhalations of 99mTc-pertechnetate (≤10MBq) radiolabelled GFF 14.4/9.6μg or placebo (porous particles only) in a crossover design with a ≥5-day washout. In vitro analyses showed that aerosol delivery was unaltered by radiolabel application. Gamma counts of the lungs, stomach, oropharynx, mouthwash and exhalation filter were determined. Results Radioactivity detected in the various regions (Table 1) showed deposition in both central and peripheral regions, with very low exhaled fraction. Deposition was similar between GFF MDI and placebo MDI. One treatment-related adverse event occurred with GFF MDI and one with placebo MDI; neither were serious. Conclusion Both GFF and placebo MDI Co-Suspension™ formulations were efficiently deposited in the lungs with similar regional deposition patterns. The variability observed among subjects was typical of inhalation studies.
- 1 September 2013
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 102 (9) , 3382-3394
Selectivity in the impact of P-glycoprotein upon pulmonary absorption of airway-dosed substrates: A study in ex vivo lung models using chemical inhibition and genetic knockout
- 1 September 2013
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 102 (9) , 3382-3394
Selectivity in the impact of P-glycoprotein upon pulmonary absorption of airway-dosed substrates: A study in ex vivo lung models using chemical inhibition and genetic knockout
- 1 December 2012
- Published by SAGE Publications in Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Vol. 25 (S1) , S10-10
Standardization of Techniques for Using Planar (2D) Imaging for Aerosol Deposition Assessment of Orally Inhaled Products
Two-dimensional (2D or planar) imaging with 99mTc radiolabels enables quantification of whole-lung and regional lung depositions for orally inhaled drug products. This article recommends standardized methodology for 2D imaging studies. Simultaneous anterior and posterior imaging with a dual-headed gamma camera is preferred, but imaging with a single-headed gamma camera is also acceptable. Correction of raw data for the effects of gamma ray attenuation is considered essential for accurate quantification, for instance, using transmission scanning with a flood-field source of 99mTc or 57Co. Evidence should be provided of the accuracy of the quantification method, for instance, by determining “mass balance.” Lung deposition may be expressed as a percentage of ex-valve or ex-device dose, but should also be given as mass of drug when possible. Assessment of regional lung deposition requires delineation of the lung borders, using X-ray computed tomography, radioactive gas scans (133Xe or 81mKr), or transmission scans. When quantifying regional lung deposition, the lung should be divided into outer (O) and inner (I) zones. A penetration index should be calculated, as the O/I ratio for aerosol, normalized to that for a radioactive gas or transmission scan. A variety of methods can be used to assess lung deposition and distribution. Methodology and results should be documented in detail, so that data from different centers may be compared. The use of appropriate methodology will provide greater confidence in the results of 2D imaging studies, and should allay concerns that such studies are qualitative or semiquantitative in nature.
- 1 December 2012
- Published by SAGE Publications in Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Vol. 25 (S1) , S10-10
Standardization of Techniques for Using Planar (2D) Imaging for Aerosol Deposition Assessment of Orally Inhaled Products
Two-dimensional (2D or planar) imaging with 99mTc radiolabels enables quantification of whole-lung and regional lung depositions for orally inhaled drug products. This article recommends standardized methodology for 2D imaging studies. Simultaneous anterior and posterior imaging with a dual-headed gamma camera is preferred, but imaging with a single-headed gamma camera is also acceptable. Correction of raw data for the effects of gamma ray attenuation is considered essential for accurate quantification, for instance, using transmission scanning with a flood-field source of 99mTc or 57Co. Evidence should be provided of the accuracy of the quantification method, for instance, by determining “mass balance.” Lung deposition may be expressed as a percentage of ex-valve or ex-device dose, but should also be given as mass of drug when possible. Assessment of regional lung deposition requires delineation of the lung borders, using X-ray computed tomography, radioactive gas scans (133Xe or 81mKr), or transmission scans. When quantifying regional lung deposition, the lung should be divided into outer (O) and inner (I) zones. A penetration index should be calculated, as the O/I ratio for aerosol, normalized to that for a radioactive gas or transmission scan. A variety of methods can be used to assess lung deposition and distribution. Methodology and results should be documented in detail, so that data from different centers may be compared. The use of appropriate methodology will provide greater confidence in the results of 2D imaging studies, and should allay concerns that such studies are qualitative or semiquantitative in nature.
- 1 December 2012
- Published by SAGE Publications in Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Vol. 25 (S1) , S6-6
Validation of Radiolabeling of Drug Formulations for Aerosol Deposition Assessment of Orally Inhaled Products
Radiolabeling of inhaler formulations for imaging studies is an indirect method of determining lung deposition and regional distribution of drug in human subjects. Hence, ensuring that the radiotracer and drug exhibit similar aerodynamic characteristics when aerosolized, and that addition of the radiotracer has not significantly altered the characteristics of the formulation, are critical steps in the development of a radiolabeling method. The validation phase should occur during development of the radiolabeling method, prior to commencement of in vivo studies. The validation process involves characterization of the aerodynamic particle size distribution (APSD) of drug in the reference formulation, and of both drug and radiotracer in the radiolabeled formulation, using multistage cascade impaction. We propose the adoption of acceptance criteria similar to those recommended by the EMA and ISAM/IPAC-RS for determination of therapeutic equivalence of orally inhaled products: (a) if only total lung deposition is being quantified, the fine particle fraction ratio of both radiolabeled drug and radiotracer to that of the reference drug should fall between 0.85 and 1.18, and (b) if regional lung deposition (e.g., outer and inner lung regions) is to be quantified, the ratio of both radiolabeled drug and radiotracer to reference drug on each impactor stage or group of stages should fall between 0.85 and 1.18. If impactor stages are grouped together, at least four separate groups should be provided. In addition, while conducting in vivo studies, measurement of the APSD of the inhaler used on each study day is recommended to check its suitability for use in man.
- 1 December 2012
- Published by SAGE Publications in Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Vol. 25 (S1) , S6-6
Validation of Radiolabeling of Drug Formulations for Aerosol Deposition Assessment of Orally Inhaled Products
Radiolabeling of inhaler formulations for imaging studies is an indirect method of determining lung deposition and regional distribution of drug in human subjects. Hence, ensuring that the radiotracer and drug exhibit similar aerodynamic characteristics when aerosolized, and that addition of the radiotracer has not significantly altered the characteristics of the formulation, are critical steps in the development of a radiolabeling method. The validation phase should occur during development of the radiolabeling method, prior to commencement of in vivo studies. The validation process involves characterization of the aerodynamic particle size distribution (APSD) of drug in the reference formulation, and of both drug and radiotracer in the radiolabeled formulation, using multistage cascade impaction. We propose the adoption of acceptance criteria similar to those recommended by the EMA and ISAM/IPAC-RS for determination of therapeutic equivalence of orally inhaled products: (a) if only total lung deposition is being quantified, the fine particle fraction ratio of both radiolabeled drug and radiotracer to that of the reference drug should fall between 0.85 and 1.18, and (b) if regional lung deposition (e.g., outer and inner lung regions) is to be quantified, the ratio of both radiolabeled drug and radiotracer to reference drug on each impactor stage or group of stages should fall between 0.85 and 1.18. If impactor stages are grouped together, at least four separate groups should be provided. In addition, while conducting in vivo studies, measurement of the APSD of the inhaler used on each study day is recommended to check its suitability for use in man.
- 15 December 2011
- Published by SAGE Publications in Cephalalgia
- Vol. 32 (2) , 150-158
Lack of drug interaction between the migraine drug MAP0004 (orally inhaled dihydroergotamine) and a CYP3A4 inhibitor in humans
Background: Dihydroergotamine (DHE), a proven migraine treatment, currently has product labeling warning against concomitant use of CYP3A4 inhibitors because of potential drug interactions. However, no reported studies of such interactions with DHE administered by any route are available. Methods: The pharmacokinetics (PK) of MAP0004, an investigative inhaled DHE formulation, were assessed in human subjects with and without CYP3A4 inhibition by ketoconazole to evaluate the potential for drug interaction, elevation of DHE levels, and increased adverse effects. Results: After MAP0004 alone vs. MAP0004 plus ketoconazole, the DHE maximum concentrations (Cmax) and area-under-the-curve (AUC0–48 and AUC0–∞) were not statistically significantly different nor was the Cmax of the primary metabolite, 8’-OH-DHE. A difference in 8’-OH-DHE AUCs was observed between MAP0004 with and without ketoconazole; however, the concentrations were very low. MAP0004 was well tolerated after both treatments. Conclusions: This study demonstrated that CYP3A4 inhibition had little to no effect on DHE PK after MAP0004 administration, apparently because of its high systemic and low gastrointestinal bioavailability. CYP3A4 inhibition slowed elimination of the metabolite 8’-OH-DHE, but concentrations were too low to be pharmacologically relevant.
- 15 December 2011
- Published by SAGE Publications in Cephalalgia
- Vol. 32 (2) , 150-158
Lack of drug interaction between the migraine drug MAP0004 (orally inhaled dihydroergotamine) and a CYP3A4 inhibitor in humans
Background: Dihydroergotamine (DHE), a proven migraine treatment, currently has product labeling warning against concomitant use of CYP3A4 inhibitors because of potential drug interactions. However, no reported studies of such interactions with DHE administered by any route are available. Methods: The pharmacokinetics (PK) of MAP0004, an investigative inhaled DHE formulation, were assessed in human subjects with and without CYP3A4 inhibition by ketoconazole to evaluate the potential for drug interaction, elevation of DHE levels, and increased adverse effects. Results: After MAP0004 alone vs. MAP0004 plus ketoconazole, the DHE maximum concentrations (Cmax) and area-under-the-curve (AUC0–48 and AUC0–∞) were not statistically significantly different nor was the Cmax of the primary metabolite, 8’-OH-DHE. A difference in 8’-OH-DHE AUCs was observed between MAP0004 with and without ketoconazole; however, the concentrations were very low. MAP0004 was well tolerated after both treatments. Conclusions: This study demonstrated that CYP3A4 inhibition had little to no effect on DHE PK after MAP0004 administration, apparently because of its high systemic and low gastrointestinal bioavailability. CYP3A4 inhibition slowed elimination of the metabolite 8’-OH-DHE, but concentrations were too low to be pharmacologically relevant.
- 1 December 2010
- Published by SAGE Publications in Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Vol. 23 (S2) , S39-39
Deposition, Imaging, and Clearance: What Remains to be Done?
Deposition and clearance studies are used during product development and in fundamental research. These studies mostly involve radionuclide imaging, but pharmacokinetic methods are also used to assess the amount of drug absorbed through the lungs, which is closely related to lung deposition. Radionuclide imaging may be two-dimensional (gamma scintigraphy or planar imaging), or three-dimensional (single photon emission computed tomography and positron emission tomography). In October 2009, a group of scientists met at the “Thousand Years of Pharmaceutical Aerosols” conference in Reykjavik, Iceland, to discuss future research in key areas of pulmonary drug delivery. This article reports the session on “Deposition, imaging and clearance.” The objective was partly to review our current understanding, but more importantly to assess “what remains to be done?” A need to standardize methodology and provide a regulatory framework by which data from radionuclide imaging methods could be compared between centers and used in the drug approval process was recognized. There is also a requirement for novel radiolabeling methods that are more representative of production processes for dry powder inhalers and pressurized metered dose inhalers. A need was identified for studies to aid our understanding of the relationship between clinical effects and regional deposition patterns of inhaled drugs. A robust methodology to assess clearance from small conducting airways should be developed, as a potential biomarker for therapies in cystic fibrosis and other diseases. The mechanisms by which inhaled nanoparticles are removed from the lungs, and the factors on which their removal depends, require further investigation. Last, and by no means least, we need a better understanding of patient-related factors, including how to reduce the variability in pulmonary drug delivery, in order to improve the precision of deposition and clearance measurements.
- 1 December 2010
- Published by SAGE Publications in Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Vol. 23 (S2) , S39-39
Deposition, Imaging, and Clearance: What Remains to be Done?
Deposition and clearance studies are used during product development and in fundamental research. These studies mostly involve radionuclide imaging, but pharmacokinetic methods are also used to assess the amount of drug absorbed through the lungs, which is closely related to lung deposition. Radionuclide imaging may be two-dimensional (gamma scintigraphy or planar imaging), or three-dimensional (single photon emission computed tomography and positron emission tomography). In October 2009, a group of scientists met at the “Thousand Years of Pharmaceutical Aerosols” conference in Reykjavik, Iceland, to discuss future research in key areas of pulmonary drug delivery. This article reports the session on “Deposition, imaging and clearance.” The objective was partly to review our current understanding, but more importantly to assess “what remains to be done?” A need to standardize methodology and provide a regulatory framework by which data from radionuclide imaging methods could be compared between centers and used in the drug approval process was recognized. There is also a requirement for novel radiolabeling methods that are more representative of production processes for dry powder inhalers and pressurized metered dose inhalers. A need was identified for studies to aid our understanding of the relationship between clinical effects and regional deposition patterns of inhaled drugs. A robust methodology to assess clearance from small conducting airways should be developed, as a potential biomarker for therapies in cystic fibrosis and other diseases. The mechanisms by which inhaled nanoparticles are removed from the lungs, and the factors on which their removal depends, require further investigation. Last, and by no means least, we need a better understanding of patient-related factors, including how to reduce the variability in pulmonary drug delivery, in order to improve the precision of deposition and clearance measurements.
- 1 July 2010
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 99 (7) , 3089-3099
In Vitro Reporter Gene Transfection via Plasmid DNA Delivered by Metered Dose Inhaler
- 1 July 2010
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 99 (7) , 3089-3099
In Vitro Reporter Gene Transfection via Plasmid DNA Delivered by Metered Dose Inhaler
- 1 April 2010
- Published by SAGE Publications in Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Vol. 23 (s1) , S37-37
Mode of Breathing—Tidal or Slow and Deep—through the I-neb Adaptive Aerosol Delivery (AAD) System Affects Lung Deposition of 99m Tc-DTPA
Background: The I-neb AAD System was designed to deliver aerosol with two different breathing pattern algorithms: the Tidal Breathing Mode (TBM) and the Target Inhalation Mode (TIM). For the purpose of the study, the TBM breathing pattern algorithm was set to guide the subjects to inhalation during tidal breathing with aerosol pulsed during 50–80% of the time spent on inhalation, whereas the TIM breathing pattern was set to guide the subject to a slow and deep inhalation of up to ∼9 sec with aerosol pulsed for up to 7 sec, leaving 2 sec for particle deposition in the lungs. In TIM, the inspiratory flow was guided to ∼20 L/min through a built-in resistance in the mouthpiece. Methods: We have, in a randomized, open-label, crossover study of 12 healthy subjects evaluated lung deposition following administration of a radiolabeled aerosol from the I-neb AAD System with the TBM and TIM breathing patterns. Results: The results showed that mean lung deposition was significantly higher when using the I-neb AAD System with the TIM breathing pattern (73.3%) than with the TBM breathing pattern (62.8%). The mean exhaled fractions were low (Conclusions: The results of the present study showed that lung deposition with the slow and deep inhalation achieved through the I-neb AAD System in TIM was superior to the lung deposition achieved during tidal breathing in TBM. With the combination of high lung deposition, almost no loss of aerosol during exhalation, and short nebulization time the I-neb AAD System with the TIM breathing pattern should be of special value to patients who require multiple daily dosing of aerosolized medication, are using drugs that should not be wasted into the room air, or would benefit from a more efficient delivery system.
- 1 April 2010
- Published by SAGE Publications in Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Vol. 23 (s1) , S37-37
Mode of Breathing—Tidal or Slow and Deep—through the I-neb Adaptive Aerosol Delivery (AAD) System Affects Lung Deposition of 99m Tc-DTPA
Background: The I-neb AAD System was designed to deliver aerosol with two different breathing pattern algorithms: the Tidal Breathing Mode (TBM) and the Target Inhalation Mode (TIM). For the purpose of the study, the TBM breathing pattern algorithm was set to guide the subjects to inhalation during tidal breathing with aerosol pulsed during 50–80% of the time spent on inhalation, whereas the TIM breathing pattern was set to guide the subject to a slow and deep inhalation of up to ∼9 sec with aerosol pulsed for up to 7 sec, leaving 2 sec for particle deposition in the lungs. In TIM, the inspiratory flow was guided to ∼20 L/min through a built-in resistance in the mouthpiece. Methods: We have, in a randomized, open-label, crossover study of 12 healthy subjects evaluated lung deposition following administration of a radiolabeled aerosol from the I-neb AAD System with the TBM and TIM breathing patterns. Results: The results showed that mean lung deposition was significantly higher when using the I-neb AAD System with the TIM breathing pattern (73.3%) than with the TBM breathing pattern (62.8%). The mean exhaled fractions were low (Conclusions: The results of the present study showed that lung deposition with the slow and deep inhalation achieved through the I-neb AAD System in TIM was superior to the lung deposition achieved during tidal breathing in TBM. With the combination of high lung deposition, almost no loss of aerosol during exhalation, and short nebulization time the I-neb AAD System with the TIM breathing pattern should be of special value to patients who require multiple daily dosing of aerosolized medication, are using drugs that should not be wasted into the room air, or would benefit from a more efficient delivery system.
- 22 October 2009
- Published by Taylor & Francis in Drug Development and Industrial Pharmacy
- Vol. 36 (5) , 614-623
Alginate–antacid combinations: raft formation and gastric retention studies
Background: Alginate-based gastroesophageal reflux disease treatments have been used extensively and fall into two main categories. Those containing alginate as the principle active agent and those containing alginate in combination with a significant amount of antacid. Method: The effectiveness of the raft formed by a new alginate/antacid suspension (Gaviscon Double Action Liquid, GDAL), in which calcium carbonate was the main antacid ingredient, was compared with those of existing alginate/antacid suspensions. Result: GDAL had similar raft strength and improved raft resilience than Gaviscon Liquid (GL), and both were significantly greater than five other products tested. Gastric retention of GDAL was similar to that of GL. Conclusion: the in vitro and in vivo performance is maintained in the new GDAL formulation even with higher antacid levels and the product is as good as, or better than, previous formulations.
- 22 October 2009
- Published by Taylor & Francis in Drug Development and Industrial Pharmacy
- Vol. 36 (5) , 614-623
Alginate–antacid combinations: raft formation and gastric retention studies
Background: Alginate-based gastroesophageal reflux disease treatments have been used extensively and fall into two main categories. Those containing alginate as the principle active agent and those containing alginate in combination with a significant amount of antacid. Method: The effectiveness of the raft formed by a new alginate/antacid suspension (Gaviscon Double Action Liquid, GDAL), in which calcium carbonate was the main antacid ingredient, was compared with those of existing alginate/antacid suspensions. Result: GDAL had similar raft strength and improved raft resilience than Gaviscon Liquid (GL), and both were significantly greater than five other products tested. Gastric retention of GDAL was similar to that of GL. Conclusion: the in vitro and in vivo performance is maintained in the new GDAL formulation even with higher antacid levels and the product is as good as, or better than, previous formulations.
- 1 June 2009
- Published by SAGE Publications in Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Vol. 22 (2) , 131-138
A Gamma Scintigraphy Study to Investigate Lung Deposition and Clearance of Inhaled Amikacin-Loaded Liposomes in Healthy Male Volunteers
Background: The purpose of this study was to investigate the inhalation of a liposomal formulation of amikacin in healthy male volunteers in terms of pulmonary deposition, clearance, and safety following nebulization with a commercial jet nebulizer. Methods: Amikacin was encapsulated in liposomes comprised of dipalmitoyl phosphatidylcholine (DPPC) and cholesterol via a proprietary manufacturing process (20 mg/mL final amikacin concentration). The liposomes were radiolabeled with 99mTc using the tin chloride labeling method. A nominal dose of 120 mg of drug product was loaded into a PARI LC STAR nebulizer, aerosolized using a PARI Boy compressor where subjects inhaled for 20 min. Lung deposition was determined by gamma scintigraphy in three healthy male volunteers at the following time points (0, 1, 3, 6, 12, 24, 48, and 72 h post-administration). Results: Total lung deposition, expressed as a percentage of the emitted dose, was 32.3 ± 3.4%. The time-dependent retention of radiolabeled liposomes was biphasic with an initial rapid reduction in counts, followed by a slower phase to 48 h. The overall mean retention at 24 and 48 h was 60.4 and 38.3% of the initial dose deposited, respectively. The observed clearance of radiolabel is consistent with clearance of amikacin following aerosol delivery to rats. There were no clinically significant changes in laboratory parameters, vital signs, or ECG. No adverse events including cough or bronchospasm were reported. Conclusions: Inhalation of a single nominal dose of 120 mg liposomal amikacin results in prolonged retention of drug-loaded liposomes in the lungs of healthy volunteers. The treatment was well tolerated.
- 1 June 2009
- Published by SAGE Publications in Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Vol. 22 (2) , 131-138
A Gamma Scintigraphy Study to Investigate Lung Deposition and Clearance of Inhaled Amikacin-Loaded Liposomes in Healthy Male Volunteers
Background: The purpose of this study was to investigate the inhalation of a liposomal formulation of amikacin in healthy male volunteers in terms of pulmonary deposition, clearance, and safety following nebulization with a commercial jet nebulizer. Methods: Amikacin was encapsulated in liposomes comprised of dipalmitoyl phosphatidylcholine (DPPC) and cholesterol via a proprietary manufacturing process (20 mg/mL final amikacin concentration). The liposomes were radiolabeled with 99mTc using the tin chloride labeling method. A nominal dose of 120 mg of drug product was loaded into a PARI LC STAR nebulizer, aerosolized using a PARI Boy compressor where subjects inhaled for 20 min. Lung deposition was determined by gamma scintigraphy in three healthy male volunteers at the following time points (0, 1, 3, 6, 12, 24, 48, and 72 h post-administration). Results: Total lung deposition, expressed as a percentage of the emitted dose, was 32.3 ± 3.4%. The time-dependent retention of radiolabeled liposomes was biphasic with an initial rapid reduction in counts, followed by a slower phase to 48 h. The overall mean retention at 24 and 48 h was 60.4 and 38.3% of the initial dose deposited, respectively. The observed clearance of radiolabel is consistent with clearance of amikacin following aerosol delivery to rats. There were no clinically significant changes in laboratory parameters, vital signs, or ECG. No adverse events including cough or bronchospasm were reported. Conclusions: Inhalation of a single nominal dose of 120 mg liposomal amikacin results in prolonged retention of drug-loaded liposomes in the lungs of healthy volunteers. The treatment was well tolerated.