BEBehzad Elahi

Behzad Elahi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Behzad Elahi has a total of 105 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Translational neuroscience in psychoeducation: Mapping nonmotor circuitry to clinical management in movement disorders

    by Behzad Elahi

    Non-motor symptoms (NMS) affect nearly all patients with Parkinson’s disease (PD)and related movement disorders, with a mean of roughly 8–10 discrete symptoms perindividual. Their effect on quality of life often exceeds that of motor features, yetNMS remain under-recognized and undertreated, partly because patients and caregivers lack a working model of why these symptoms arise in a “movement” disease.This chapter applies neuroscience-informed psychoeducation (NIPE) to that gap andpositions it relative to conventional psychoeducation, health communication, and behavioral science. We propose the Map-Normalize-Differentiate-Navigate (MNDN)workflow as a movement-disorders-specific implementation of the NIPE frameworkdescribed in Chapter 1 of this volume. MNDN is a clinical proposal, not a validatedprotocol: its components are specified so that it can be tested, but its effects on patient outcomes have not been evaluated. Drawing on the tripartite cortico-basal ganglia-thalamocortical loop model and multi-transmitter degeneration, we provide modules for seven high-yield NMS: apathy, anxiety, executive dysfunction, REM sleepbehavior disorder, neurogenic orthostatic hypotension, psychosis, and fatigue. Eachmodule summarizes the neural systems implicated, at the level of certainty the evidence supports, together with common misattributions, reversible contributors thatmust be excluded, management options and their limits, and patient and caregiverhandout content. We describe delivery formats from 3 to 5 min “micro-NIPE” sessions in routine visits to group and telehealth programs, specify the minimum components, provider competencies, dose, fidelity criteria, and proximal outcomes neededto test MNDN, and examine the ethical risks of neurobiological framing (determinism, oversimplification, over-attribution, and false reassurance), with particular attention to prognostic counseling in REM sleep behavior disorder. NIPE in movementdisorders is designed to reduce self-blame, support accurate symptom attribution, andimprove collaborative management. Whether it does so is an empirical question thatthis chapter aims to make answerable.

  • Top Cited Papers
    Open Access

    Neuroscience-informed Psychoeducation (NIPE): How Brain Awareness Supports Brain Recovery

    by Tara Rezapour, Jamie Berry, C. Munro Cullum, Behzad Elahi, Islam Elbanna, Medhat Elsabbahy, Mehdi Farokhnia, Nabila Haque, Jing Jin, Mario Juruena, et al.

    Over the past two decades, Neuroscience-Informed Psychoeducation (NIPE) has gradually evolved and become integrated into various therapy modules for psychiatric and neurological disorders. Although NIPE shares certain features with conventional psychoeducation, it is distinguished by key content and structure-related elements. Its content centers on brain-based explanations of the mechanisms and symptoms underlying psychiatric and neurological disorders, as well as the neural processes associated with treatment response, remission, and recovery. NIPE promotes self-awareness and insight and may contributes to motivation for treatment and treatment adherence. It also informs patients, caregivers, and communities how to play an active role in the prevention, treatment, and recovery process based on this mechanistic understanding. Structurally, NIPE is designed to align with how the brain learns and adapts, improving the learning experience to promote more enduring outcomes. By clarifying the processes and goals of brain recovery, increasing self-awareness and self-efficacy, and supporting adherence to prescribed treatments, NIPE may enhance motivation and retention, and facilitate recovery while reducing shame and stigma. This paper provides an introductory overview of NIPE including its definitions and terminology, the current evidence base, clinical implications, and directions for future development.


  • Open Access

    Experimental Validation of Finite Element Models for Directional DBS: The Critical Role of Boundary Conditions on VTA Accuracy

    by Kaylee R. Henry, Fuchang Jiang, William A Wartman, Dexuan Tang, Yifeng Qian, Behzad Elahi, Sergey N. Makaroff, Laleh Golestani Rad

    Objective: Computational models and visualization toolboxes for Deep Brain Stimulation (DBS) increasingly rely on pre-computed electric field libraries to estimate the Volume of Tissue Activated (VTA). However, the boundary conditions (BCs) and source models used to generate these fields vary widely across studies, and there is currently no experimental consensus regarding which parameters most accurately reflect the physical device output. The objective of this study was to experimentally validate the electric potential distribution of directional DBS leads in order to determine the optimal Finite Element Method (FEM) configuration. Approach: The voltage distribution surrounding a Boston Scientific Vercise Gevia directional lead was mapped in a saline phantom using a custom high-precision robotic scanning system. Experimental measurements were compared against six FEM configurations that varied in source formulation (Dirichlet vs. Neumann boundary conditions) and ground definitions. For each configuration, the resulting VTA volume was computed to assess the clinical impact of modeling assumptions. Results: The FEM configuration implementing a Dirichlet (voltage) boundary condition on the active contact with a grounded implantable pulse generator (IPG) surface demonstrated the highest accuracy, achieving a Symmetric Mean Absolute Percent Error (SMAPE) of less than 9% across all contact levels. In contrast, conventional current-controlled simulations employing Neumann boundary conditions with disparate ground definitions substantially overestimated electric field spread. Suboptimal boundary condition selection resulted in an approximate 67% overestimation of VTA volume (137 mm3 vs. 82 mm3) relative to the experimentally validated model. Significance: Although clinical DBS systems operate as current sources, standard Neumann (current density) boundary conditions do not adequately represent the equipotential behavior of the electrode-tissue interface, resulting in nearly a two-fold error in predicted VTA volume. To improve the validity of predictive clinical models, we recommend the use of Dirichlet boundary conditions derived from the device operating impedance (V= Itarget × Zmeasured) rather than conventional current density specifications.

  • Variations in Determining Actual Orientations of Segmented Deep Brain Stimulation Leads Using the DiODe Algorithm: A Retrospective Study Across Different Lead Designs and Medical Institutions

    by Kaylee R. Henry, Milina Michelle Miulli, Noa B. Nuzov, Mark J. Nolt, Joshua M. Rosenow, Behzad Elahi, Julie Pilitsis, Laleh Golestanirad

    Introduction: Directional deep brain stimulation (DBS) leads have become widely used in the past decade. Understanding the asymmetric stimulation provided by directional leads requires precise knowledge of the exact orientation of the lead in respect to its anatomical target. Recently, the DiODe algorithm was developed to automatically determine the orientation angle of leads from the artifact on postoperative computed tomography (CT) images. However, manual DiODe results are user-dependent. This study analyzed the extent of lead rotation as well as the user agreement of DiODe calculations across the two most common DBS systems, namely, Boston Scientific’s Vercise and Abbott’s Infinity, and two independent medical institutions. Methods: Data from 104 patients who underwent an anterior-facing unilateral/bilateral directional DBS implantation at either Northwestern Memorial Hospital (NMH) or Albany Medical Center (AMC) were retrospectively analyzed. Actual orientations of the implanted leads were independently calculated by three individual users using the DiODe algorithm in Lead-DBS and patients’ postoperative CT images. The deviation from the intended orientation and user agreement were assessed. Results: All leads significantly deviated from the intended 0° orientation (p < 0.001), regardless of DBS lead design (p < 0.05) or institution (p < 0.05). However, the Boston Scientific leads showed an implantation bias toward the left at both institutions (p = 0.014 at NMH, p = 0.029 at AMC). A difference of 10° between at least two users occurred in 28% (NMH) and 39% (AMC) of all Boston Scientific and 76% (NMH) and 53% (AMC) of all Abbott leads. Conclusion: Our results show that there is a significant lead rotation from the intended surgical orientation across both DBS systems and both medical institutions; however, a bias toward a single direction was only seen in the Boston Scientific leads. Additionally, these results raise questions into the user error that occurs when manually refining the orientation angles calculated with DiODe.


  • Open Access

    Artifacts Can Be Deceiving: The Actual Location of Deep Brain Stimulation Electrodes Differs from the Artifact Seen on Magnetic Resonance Images

    by Noa B. Nuzov, Bhumi Bhusal, Kaylee R. Henry, Fuchang Jiang, Jasmine Vu, Joshua M. Rosenow, Julie G. Pilitsis, Behzad Elahi, Laleh Golestanirad

    Introduction: Deep brain stimulation (DBS) is a common treatment for a variety of neurological and psychiatric disorders. Recent studies have highlighted the role of neuroimaging in localizing the position of electrode contacts relative to target brain areas in order to optimize DBS programming. Among different imaging methods, postoperative magnetic resonance imaging (MRI) has been widely used for DBS electrode localization; however, the geometrical distortion induced by the lead limits its accuracy. In this work, we investigated to what degree the difference between the actual location of the lead’s tip and the location of the tip estimated from the MRI artifact varies depending on the MRI sequence parameters such as acquisition plane and phase encoding direction, as well as the lead’s extracranial configuration. Accordingly, an imaging technique to increase the accuracy of lead localization was devised and discussed. Methods: We designed and constructed an anthropomorphic phantom with an implanted DBS system following 18 clinically relevant configurations. The phantom was scanned at a Siemens 1.5 Tesla Aera scanner using a T1MPRAGE sequence optimized for clinical use and a T1TSE sequence optimized for research purposes. We varied slice acquisition plane and phase encoding direction and calculated the distance between the caudal tip of the DBS lead MRI artifact and the actual tip of the lead, as estimated from MRI reference markers. Results: Imaging parameters and lead configuration substantially altered the difference in the depth of the lead within its MRI artifact on the scale of several millimeters − with a difference as large as 4.99 mm. The actual tip of the DBS lead was found to be consistently more rostral than the tip estimated from the MR image artifact. The smallest difference between the tip of the DBS lead and the tip of the MRI artifact using the clinically relevant sequence (i.e., T1MPRAGE) was found with the sagittal acquisition plane and anterior-posterior phase encoding direction. Discussion/Conclusion: The actual tip of an implanted DBS lead is located up to several millimeters rostral to the tip of the lead’s artifact on postoperative MR images. This distance depends on the MRI sequence parameters and the DBS system’s extracranial trajectory. MRI parameters may be altered to improve this localization.


  • Neuromuscular transmission defects in myopathies: Rare but worth searching for

    by Behzad Elahi, Ruple S. Laughlin, William J. Litchy, Margherita Milone, Teerin Liewluck

    Introduction: Decremental responses in repetitive nerve stimulation have been reported in a few hereditary myopathies. We examined the frequency of decrement in a cohort of myopathy patients. Methods: We reviewed all patients referred for myopathy who underwent repetitive nerve stimulation between January 2007 and May 2017. We included patients with decrement (>10%) and either a pathological or molecular diagnosis of myopathy. Results: Among 157 patients with myopathies, 4 patients had decrement (2 hydroxychloroquine‐associated vacuolar myopathy, 1 centronuclear myopathy, and 1 distal myopathy). One hydroxychloroquine‐associated vacuolar myopathy patient also had inflammatory myopathy. Pyridostigmine improved weakness in the centronuclear myopathy patient, but not in the distal myopathy patient. No patient with an acquired myopathy received pyridostigmine. Conclusions: Despite the rare occurrence of decrement in myopathy, its presence may urge consideration of pharmacological intervention. Muscle Nerve 59:475–478, 2019


  • Open Access

    Reconfigurable MRI coil technology can substantially reduce RF heating at the tips of bilateral deep brain stimulation implants

    by Laleh Golestanirad, Boris Keil, Sean Downs, John Kirsch, Behzad Elahi, Julie Pilitsis, Lawrence L Wald

    Patients with deep brain stimulation (DBS) implants can significantly benefit from magnetic resonance imaging (MRI) examination, however, access to MRI is restricted in this patients because of safety concerns due to RF heating of the leads. Recently we introduced a patient-adjustable reconfigurable MRI coil system to reduce the SAR at the tip of deep brain stimulation implants during MRI at 1.5T. A simulation study with realistic models of single (unilateral) DBS leads demonstrated a substantial reduction in the local SAR up to 500-fold could be achieved using the coil system compared to quadrature birdcage coils. Many patients however, have bilateral DBS implants and the question arises whether the rotating coil system can be used in for them. This work reports the results of phantom experiments measuring the temperature rise at the tips of bilateral DBS implants with realistic trajectories extracted from postoperative CT images of 10 patients (20 leads in total). A total of 200 measurements were performed to record temperature rise at the tips of the leads during 2 minutes of scanning with the coil rotated to cover all accessible rotation angles. In all patients, we were able to find an optimum coil rotation angle and reduced the heating of both left and right leads to a level below the heating produced by the body coil. An average heat reduction of 65% was achieved for bilateral leads. Reconfigurable coil technology introduces a promising approach for imaging of patients with DBS implants.


  • Open Access

    Dose-response curve of associative plasticity in human motor cortex and interactions with motor practice

    by Behzad Elahi, William D. Hutchison, Z. Jeff Daskalakis, Carolyn Gunraj, Robert Chen

    Associative plasticity is hypothesized to be an important neurophysiological correlate of memory formation and learning with potentials for applications in neurorehabilitation and for the development of new electrophysiological measures to study disorders of cortical plasticity. We hypothesized that the magnitude of the paired associative stimulation (PAS)-induced long-term potentiation (LTP)-like effect depends on the number of pairs in the PAS protocol. We also hypothesized that homeostatic interaction of PAS with subsequent motor learning is related to the magnitude of the PAS-induced LTP-like effect. We studied 10 healthy subjects. In experiment 1a, subjects received 90 (PAS90), 180 (PAS180), or 270 (PAS270) pairs of stimuli, followed by a dynamic motor practice (DMP) 1 h after the end of the PAS protocols. In experiment 1b, the DMP preceded the PAS protocol. In experiment 2, the time course of PAS270 was studied. We found that PAS270 resulted in greater increase in motor evoked potential (MEP) amplitude compared with protocols with fewer pairs of stimuli. Moreover, the interaction between PAS protocols with motor learning differed depending on the number of stimulus pairs used to induce PAS. While DMP alone increased MEP amplitudes, DMP during the LTP-like effects induced by PAS270 led to a long-term depression (LTD)-like effect (homeostatic interaction). This homeostatic interaction did not occur after PAS90 and PAS180. In conclusion, we found a dose-dependent effect of the number of stimulus pairs used in the PAS protocol on cortical plasticity. Homeostatic interaction between PAS and DMP was observed only after PAS270.


    • 1 January 2014
      • Vol. 52  (12) , 922-6

    Selecting emergency medicine: rationales from perspective of Iranian residents.

    by Shervin Farahmand, Seyed Mojtaba Aghili, Saharnaz Nedjat, Maryam Kia, Rokhsareh Aghili, Behzad Elahi

    Emergency medicine is a relatively new specialty in Iran. Therefore, the general public and the medical community do not have enough information on its duties, capabilities, its nature, and its work schedule or its degree of occupational difficulty compared to other specialties. Hence, an insight from the early group of residents who selected this specialty can help identify the strengths and weaknesses of this field in order to promote the scientific quality of this field, and attract medical students. It can also help to alleviate deficiencies and strengthen positive aspects of emergency medicine. The aim of this study was to identify the reasons behind choosing emergency medicine as a specialty. A qualitative study was conducted using semi-structured interviews. Maximum variation opportunistic sampling was done, and face-to-face interviews were held with 23 emergency medicine residents and fellows (4 faculty members and 19 residents). Data were analyzed through thematic analysis, and categories and themes were extracted. The main levels extracted were: 1) Individual priorities, 2) the nature of work and the field of study, and 3) professional future. The themes of each main level were extracted and encoded. This study showed that the majority of residents choose emergency medicine specialty to achieve a better social and professional status in one of the most challenging fields of medicine.


  • Open Access

    Analysis of fractal electrodes for efficient neural stimulation

    by Laleh Golestanirad, Behzad Elahi, Alberto Molina, Juan R. Mosig, Claudio Pollo, Robert Chen, Simon J. Graham

    Planar electrodes are increasingly used in therapeutic neural stimulation techniques such as functional electrical stimulation, epidural spinal cord stimulation and cortical stimulation. Recently, optimized electrode geometries have been shown to increase the efficiency of neural stimulation by increasing the variation of current density on the electrode surface. In the present work, a new family of modified fractal electrode geometries is developed to enhance the efficiency of neural stimulation. It is shown that a promising approach in increasing the neural activation function is to increase the “edginess” of the electrode surface, a concept that is explained and quantified by fractal mathematics. Rigorous finite element simulations were performed to compute electric potential produced by proposed modified fractal geometries. The activation of 256 model axons positioned around the electrodes was then quantified, showing that modified fractal geometries required a 22% less input power while maintaining the same level of neural activation. Preliminary in-vivo experiments investigating muscle evoked potentials due to median nerve stimulation showed encouraging results, supporting the feasibility of increasing neural stimulation efficiency using modified fractal geometries.