Artifacts Can Be Deceiving: The Actual Location of Deep Brain Stimulation Electrodes Differs from the Artifact Seen on Magnetic Resonance Images
Open Access
- 16 December 2022
- journal article
- research article
- Published by S. Karger AG in Stereotactic and Functional Neurosurgery
- Vol. 101 (1) , 47-59
Abstract
Introduction: Deep brain stimulation (DBS) is a common treatment for a variety of neurological and psychiatric disorders. Recent studies have highlighted the role of neuroimaging in localizing the position of electrode contacts relative to target brain areas in order to optimize DBS programming. Among different imaging methods, postoperative magnetic resonance imaging (MRI) has been widely used for DBS electrode localization; however, the geometrical distortion induced by the lead limits its accuracy. In this work, we investigated to what degree the difference between the actual location of the lead’s tip and the location of the tip estimated from the MRI artifact varies depending on the MRI sequence parameters such as acquisition plane and phase encoding direction, as well as the lead’s extracranial configuration. Accordingly, an imaging technique to increase the accuracy of lead localization was devised and discussed. Methods: We designed and constructed an anthropomorphic phantom with an implanted DBS system following 18 clinically relevant configurations. The phantom was scanned at a Siemens 1.5 Tesla Aera scanner using a T1MPRAGE sequence optimized for clinical use and a T1TSE sequence optimized for research purposes. We varied slice acquisition plane and phase encoding direction and calculated the distance between the caudal tip of the DBS lead MRI artifact and the actual tip of the lead, as estimated from MRI reference markers. Results: Imaging parameters and lead configuration substantially altered the difference in the depth of the lead within its MRI artifact on the scale of several millimeters − with a difference as large as 4.99 mm. The actual tip of the DBS lead was found to be consistently more rostral than the tip estimated from the MR image artifact. The smallest difference between the tip of the DBS lead and the tip of the MRI artifact using the clinically relevant sequence (i.e., T1MPRAGE) was found with the sagittal acquisition plane and anterior-posterior phase encoding direction. Discussion/Conclusion: The actual tip of an implanted DBS lead is located up to several millimeters rostral to the tip of the lead’s artifact on postoperative MR images. This distance depends on the MRI sequence parameters and the DBS system’s extracranial trajectory. MRI parameters may be altered to improve this localization.Keywords
All Related Versions
This publication has 56 references indexed in Scilit:
- Is MRI a reliable tool to locate the electrode after deep brain stimulation surgery? Comparison study of CT and MRI for the localization of electrodes after DBSActa Neurochirurgica, 2010
- Long-term results of thalamic deep brain stimulation for essential tremorJournal of Neurosurgery, 2010
- Intraoperative X-Ray Detection and MRI-Based Quantification of Brain Shift Effects Subsequent to Implantation of the First Electrode in Bilateral Implantation of Deep Brain Stimulation ElectrodesStereotactic and Functional Neurosurgery, 2009
- Effect of brain shift on the creation of functional atlases for deep brain stimulation surgeryInternational Journal of Computer Assisted Radiology and Surgery, 2009
- Contact position analysis of deep brain stimulation electrodes on post-operative CT imagesActa Neurochirurgica, 2009
- Deep Brain Stimulation of the Ventral Capsule/Ventral Striatum for Treatment-Resistant DepressionBiological Psychiatry, 2009
- Accuracy and Distortion of Deep Brain Stimulation Electrodes on Postoperative MRI and CTCentral European Neurosurgery, 2008
- Bilateral Deep-Brain Stimulation of the Globus Pallidus in Primary Generalized DystoniaNew England Journal of Medicine, 2005
- Electric field and stimulating influence generated by deep brain stimulation of the subthalamic nucleusClinical Neurophysiology, 2004
- Determining the position and size of the subthalamic nucleus based on magnetic resonance imaging results in patients with advanced Parkinson diseaseJournal of Neurosurgery, 2004