SSSri Sundaram

Sri Sundaram

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sri Sundaram has a total of 136 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Monitored anesthesia care versus general anesthesia for balloon-in-basket pulsed-field ablation of atrial fibrillation: an age-matched analysis of procedural timing and acute procedural outcomes

    by Sri Sundaram, Nicholas Palmeri, Dan Alyesh, Lukasz Cerbin, Kareena Sundaram, Ariella Rappaport, Andres Javier Dorado Montoya, Henry Zheng, William Choe, J. R. Stanton, et al.

    Background: General anesthesia (GA) has been the preferred sedation strategy for atrial fibrillation (AF) catheter ablation in the United States, in part because pulsed-field ablation (PFA) systems cause skeletal muscle stimulation and discomfort that can be poorly tolerated under lighter sedation. A recently introduced balloon-in-basket (BiB) PFA system (VOLT) has been reported to produce less muscle stimulation and pain, potentially allowing Monitored Anesthesia Care (MAC) instead of GA. Whether MAC offers procedural efficiency advantages without compromising ablation efficacy in this context has not been well characterized. Objective: To compare procedural timing, ablation efficacy, and safety between MAC and GA in patients undergoing BiB PFA (VOLT) for AF, using an age-matched design. Methods: We retrospectively analyzed 39 consecutive MAC cases and a pool of 83 GA cases undergoing VOLT BiB PFA from a two-site electrophysiology registry. Each MAC patient was matched 1:1 to the nearest age available GA patient yielding 39 age-matched controls. Six different time intervals were collected: total room time, pre-procedure setup time, core procedure time, post-procedure turnover time, transseptal-to-left atrial (LA) sheath-out (dwell) time, and ablation catheter dwell time. Total ablation lesions delivered, acute procedural success (isolation of all four pulmonary veins), and procedural complications were also compared. Group comparisons were then made. In addition, EP laboratory facility cost savings and scheduling opportunity cost associated with the observed difference in total room time, using published EP/procedural-suite per-minute cost estimates were also determined. Results: Total room time (103.5 ± 20.0 vs. 126.2 ± 33.1 min; p = 0.0004), pre-procedure setup time (33.4 ± 10.0 vs. 50.3 ± 28.0 min; p = 0.0007), and post-procedure turnover time (14.8 ± 9.3 vs. 21.4 ± 8.3 min; p = 0.0030) were significantly shorter with MAC. Core procedure time (55.3 ± 20.5 vs. 55.3 ± 23.9 min), transseptal-to-LA-sheath-out time (34.2 ± 12.9 vs. 35.7 ± 18.5 min) did not differ significantly between groups (both p ≥ 0.62). Ablation catheter dwell time was modestly longer with MAC (27.7 ± 11.9 vs. 24.2 ± 15.5 min; p = 0.036). Total ablation lesions delivered (17.6 ± 5.1 vs. 18.8 ± 7.2, p = 0.68) and acute procedural success (39/39 [100%] vs. 39/39 [100%]) were similar between MAC and GA, with no procedural complications in either group. One MAC case (2.6%) was converted to general anesthesia interprocedurally for coughing attributed to airway secretions. Applying published EP/procedural-suite per-minute cost estimates ($29–$60/minute) to the observed 22.7-min reduction in total room time, MAC was associated with an estimated $658–$1,362 in facility cost savings per case, with potential opportunity cost benefit for additional case scheduling. Conclusion: In an age-matched cohort undergoing BiB PFA (VOLT) for AF, MAC was associated with shorter total room time, pre-procedure setup time, and post-procedure turnover time than GA, with no difference in ablation lesion delivery, acute success, or complications. Anesthesia related time savings with MAC appear concentrated in room logistics rather than the ablation procedure itself, with no detectable difference in acute procedural outcomes in this small cohort, supporting MAC as a reasonable alternative to GA for BiB PFA.

  • Open Access

    Safety and effectiveness of a novel dual-energy radiofrequency/pulsed field ablation catheter: 12-month results of the FlexPulse study

    by Ayman A Hussein, Gediminas Rackauskas, Sri Sundaram, Jonathan P Piccini, Franz Xaver Roithinger, Patricia Tung, Jose Osorio, B Judson Colley, Usman R Siddiqui, Dhanunjaya R Lakkireddy, et al.

    Aims: Pulsed field (PF) ablation is increasingly used to treat paroxysmal atrial fibrillation (PAF). FlexPulse (NCT06676072) was conducted to evaluate safety and effectiveness of a novel dual-energy, flexible-tip focal ablation catheter with radiofrequency and PF for treatment of symptomatic, drug-refractory PAF. Methods and results: FlexPulse was a global, prospective, single-arm, multicentre study. The ablation procedures targeted pulmonary vein isolation (PVI) and adjunctive ablation at operators’ discretion. The primary safety endpoint was occurrence of pre-defined safety events within 7 days of any ablation procedure. The primary effectiveness endpoint was freedom from a composite of recurrent AF/atrial tachycardia/atrial flutter, repeat procedure, new use or escalation of class I/III AAD, and/or cardioversion through 12-months. Overall, 180 subjects underwent PAF ablation. Successful PVI was achieved in all participants. Additional non-PV ablations were performed in 37.2% (67/180) of subjects. The primary safety endpoint event rate was 1.7%. The primary effectiveness endpoint was 74.6% at 12 months, and freedom from documented AF/AFL/AT recurrence was 77.4% (92.6% without weekly transtelephonic monitoring). In 15 subjects who underwent repeat ablation after the blanking period, remapping indicated that 79.7% (47/59) of the PVs were durably isolated from the index procedures. Retrospective analysis found that workflows with PFA Index (PI) ≥ 30 and AutoMark distance up to 6 mm target had a 12-month freedom from AF/AFL/AT of 84.6%. Conclusion: In this trial, ablation with TactiFlex Duo in patients with symptomatic, drug-refractory PAF was safe and effective.


  • Concurrent SVT and atrial fibrillation ablation using a dual-energy linear ablation catheter

    by Sri Sundaram, Daniel Alyesh, Nicholas O. Palmeri, Jose Osorio, Monica Lo

  • One year outcomes of a fluoroless pulsed field ablation approach for atrial fibrillation

    by Daniel Alyesh, Nicholas O. Palmeri, Luke Cerbin, Henry Zheng, Cooper Erickson, Kristian Hooker, William Choe, Sri Sundaram

  • Safety and effectiveness of zero fluoroscopy procedures using a novel dual-energy ablation catheter

    by Sri Sundaram, Patricia Tung, Dale Yoo, Dhanunjaya Lakkireddy, Usman Siddiqui, Jose Osorio, Kent Nilsson, Dipak Shah, Philipp Sommer, Monica Lo

  • Microbubble and thermal profile of an eight-spline pulsed field ablation system in a pre-clinical model

    by Ben Niemiera, Ravi Ranjan, Jonathan P. Piccini, John Nguyen, Lakshya Mittal, Catherine Pipenhagen, Jed Overmann, Taylor Spangler, Sri Sundaram

    Background Pulsed field ablation (PFA) has become a clinically accepted energy modality for catheter ablation of atrial fibrillation. As PFA catheters improve and evolve, iatrogenic cerebral events remain an important consideration when evaluating the safety of new devices. Several factors unique to each PFA system have the potential to lead to embolic events, including but not limited to thermal effects leading to char or coagulum formation and microbubble production. Objectives To characterize the thermal profile and microbubble production from an 8-spline balloon-in-basket PFA catheter. Methods PFA applications from a 12.5 F, over-the-wire, balloon-in-basket PFA catheter were performed on non-perfused ex vivo bovine tissue. Fiber-optic thermometry probes were used to assess temperature (surface, 3 mm, and 7 mm intramurally) after 8, 16, and 70 consecutive PFA applications. Gross and histopathological assessments were completed to assess for indicators of thermal tissue damage. Microbubble production was evaluated using an extracorporeal blood loop (left femoral vein and right femoral artery loop in N = 6 swine) with an ultrasonic bubble counter and flow meter. For each application, microbubble quantity, size, and gas volume were measured. Results None of the ablations resulted in a tissue temperature above 50 °C. A single ablation produced, on average, 187 microbubbles and 30.3 nL of gas. The PFA system produced bubbles with an average diameter of 43 µm. All measures were significantly below the RF derived thresholds of 1174 microbubbles, 1128 nL, and 49 µm, respectively. Conclusion This 12.5 F, over-the-wire, balloon-in-basket PFA catheter and associated therapy did not lead to clinically significant temperature rises that may cause thermal necrosis, char, and coagulum. In addition, this PFA catheter produced fewer and smaller microbubbles with less total gas volume compared to radiofrequency (RF) devices with available data. Graphical Abstract


  • Remote monitoring of leadless pacemakers using a novel conductive telemetry communication method

    by Sri Sundaram, Nitika Chellappa, Kunal Chaniary, Monica Lo, Devi Nair, Rajesh Banker

    Background Remote care has become part of the standard of care for cardiac rhythm device management. The Aveir™ single-chamber (AR and VR) and dual-chamber (DR) leadless pacemaker (LP) systems (Abbott, Abbott Park, IL) utilize a novel conductive telemetry communication schema for device interrogation and programming. A patient transmitter is designed as an at-home remote monitoring solution that interrogates the Aveir leadless pacemaker system via conductive telemetry and transmits the patient data. Objective To characterize the performance of a remote care system that interrogates implanted Aveir LP systems via conductive telemetry. Methods Patients implanted with an Aveir DR, VR, or AR system were enrolled in a data collection study upon hospital IRB approval of the study. The study protocol included (1) in-clinic interrogation of the LP system using the patient transmitter in a controlled setting, in two modes of use (hand-held and wired modes); and (2) optional at-home interrogation using the patient transmitter. Results Thirty-one (25 males/6 females) subjects in three centers completed in-clinic interrogation of their Aveir system using the patient transmitter in both modes of use. Eighteen subjects completed at-home interrogation. Transmitter performance was comparable between modes of use, and between in-clinic and at-home interrogation. In all subjects 31/31 (100%), end-to-end remote care system use was successful. Conclusion The initial, real-world experience of utilizing an end-to-end remote care system with Aveir LP patients demonstrated feasibility of this technology to offer an at-home remote monitoring solution for leadless pacemaker patients via conductive telemetry (Funded by Abbott Laboratories; Clinical Trials.gov ID:NCT06542133). Graphical Abstract


  • Preclinical evaluation of a novel 8-spline pulsed field ablation system

    by Sri Sundaram, John Nguyen, Daniel J. Friedman, Ravi Ranjan, Toshimasa Okabe, Jonathan P. Piccini, Mackenzi Mbai, Monica Lo, Taylor Spangler, Catherine Pipenhagen, et al.


  • Open Access

    Sex differences in leadless pacemakers: pacing is still not a woman’s world

    by Nicholas O. Palmeri, Margot Yopes, Daniel Alyesh, Sri Sundaram