Nicholas O. Palmeri
Research Subjects
Nicholas O. Palmeri has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Alyesh
Cardiac Electrophysiology, South Denver Cardiology Associates, Littleton, USA
4 shared publications - Sri Sundaram
Cardiac Electrophysiology, South Denver Cardiology Associates, Littleton, USA
4 shared publications - William Choe
Cardiac Electrophysiology, South Denver Cardiology Associates, Littleton, USA
3 shared publications - Benjamin Jones
Abbott Laboratories, North Chicago, USA
1 shared publication - Cooper Erickson
South Denver Cardiology Associates, Littleton, USA
1 shared publication - Cooper Erickson
Alice Walton School of Medicine, Bentonville, USA
1 shared publication
Latest Publications
- 10 March 2026
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 69 (8) , 2225-2231
One year outcomes of a fluoroless pulsed field ablation approach for atrial fibrillation
- 10 March 2026
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 69 (8) , 2225-2231
One year outcomes of a fluoroless pulsed field ablation approach for atrial fibrillation
- Open Access
- 22 October 2024
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 68 (5) , 969-970
Sex differences in leadless pacemakers: pacing is still not a woman’s world
- 22 October 2024
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 68 (5) , 969-970
Open AccessSex differences in leadless pacemakers: pacing is still not a woman’s world
- 23 August 2024
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 68 (4) , 757-765
Pulsed-field ablation for atrial fibrillation without the use of fluoroscopy
Introduction Pulsed-field ablation (PFA) and fluoroless ablation (FA) are emerging techniques in contemporary in electrophysiology. With widespread use of 3D electroanatomic mapping systems and advanced intracardiac echo (ICE) imaging, fluoroless ablation has become more widely adopted. However, with the importance of tissue contact for lesion durability, initial PFA has been used with fluoroscopic guidance, but both ICE and electroanatomic mapping make fluoroless PFA feasible. The objective of this study is to demonstrate that PFA can be done safely and effectively without fluoroscopy. Methods At a single center, consecutive patients undergoing ablation with a pentaspline PFA catheter using a fluoroless approach are described. The standard 3D anatomic map settings were adjusted with changes in interior and exterior projection, respiratory compensation, and interpolation. In addition, projection map lesions were used to confirm adequate circumferential ablation lesions. ICE was used extensively for wire guidance and evaluation of contact with tissue. Results Beginning on March 15, 2024, 50 consecutive subjects (19 female/31 male) aged 68.0 (± 13.7) underwent PFA ablation. The average CHA2DS2-VA2Sc score was 3.0 (± 1.9). The average LVEF was 57.3% (± 10.0) and the average LA size was 3.9 cm (± 1.2). Projection lesions were placed with every application of PFA. An average of 41.7 (± 8.5) PFA applications were placed. In 100% (50/50) of subjects, acute isolation of the pulmonary veins was achieved. Eighteen subjects also underwent concomitant posterior wall isolation and in 100% of these subjects, posterior isolation was achieved. There were zero complications in this cohort. In 50/50 subjects (100%), fluoroscopy was not used. In comparison to the control cohort, the LA dwell time of the ablation catheter was similar (p = 0.34). Conclusion In comparison to the traditional PFA with fluoroscopy, this proof-of-concept study shows fluoroless PFA ablation can be performed safely and with similar acute success rates as with use of fluoroscopy.
- 23 August 2024
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 68 (4) , 757-765
Pulsed-field ablation for atrial fibrillation without the use of fluoroscopy
Introduction Pulsed-field ablation (PFA) and fluoroless ablation (FA) are emerging techniques in contemporary in electrophysiology. With widespread use of 3D electroanatomic mapping systems and advanced intracardiac echo (ICE) imaging, fluoroless ablation has become more widely adopted. However, with the importance of tissue contact for lesion durability, initial PFA has been used with fluoroscopic guidance, but both ICE and electroanatomic mapping make fluoroless PFA feasible. The objective of this study is to demonstrate that PFA can be done safely and effectively without fluoroscopy. Methods At a single center, consecutive patients undergoing ablation with a pentaspline PFA catheter using a fluoroless approach are described. The standard 3D anatomic map settings were adjusted with changes in interior and exterior projection, respiratory compensation, and interpolation. In addition, projection map lesions were used to confirm adequate circumferential ablation lesions. ICE was used extensively for wire guidance and evaluation of contact with tissue. Results Beginning on March 15, 2024, 50 consecutive subjects (19 female/31 male) aged 68.0 (± 13.7) underwent PFA ablation. The average CHA2DS2-VA2Sc score was 3.0 (± 1.9). The average LVEF was 57.3% (± 10.0) and the average LA size was 3.9 cm (± 1.2). Projection lesions were placed with every application of PFA. An average of 41.7 (± 8.5) PFA applications were placed. In 100% (50/50) of subjects, acute isolation of the pulmonary veins was achieved. Eighteen subjects also underwent concomitant posterior wall isolation and in 100% of these subjects, posterior isolation was achieved. There were zero complications in this cohort. In 50/50 subjects (100%), fluoroscopy was not used. In comparison to the control cohort, the LA dwell time of the ablation catheter was similar (p = 0.34). Conclusion In comparison to the traditional PFA with fluoroscopy, this proof-of-concept study shows fluoroless PFA ablation can be performed safely and with similar acute success rates as with use of fluoroscopy.
- 1 August 2024
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 68 (2) , 433-439
Cardioneural ablation—the first case series without the use of fluoroscopy
Introduction Cardioneural ablation (CNA) and fluoroless ablation (FA) are emerging procedures and movements in contemporary in electrophysiology. Ablation of ganglionated plexus (GP) inputs in the atrium has been successfully targeted as a treatment for symptomatic bradyarrhythmias due to increased parasympathetic tone. As most of these patients are young, avoidance of ionizing radiation is of critical importance to limit potential long term deleterious effects. With widespread use of 3D electroanatomic mapping systems and advanced intracardiac echo (ICE) imaging, fluoroless ablation has become more widely adopted. However, fluoroless CNA has not been widely performed. The objective of this study is to demonstrate that CNA can be done safely and effectively without fluoroscopy. Methods At a single-center, consecutive patients undergoing CNA with a fluoroless approach are described. GP mapping and ablation were performed in both atria. From the right atrium (RA), the right atrium-superior vena cava (RA-SVC GP), the posteromedial ganglionated plexus (PMLGP), which can be accessed from the right atrium-coronary sinus ostium, and the Vein of Marshall GP (VOM-GP) were evaluated. From the left atrium (LA), the superior left atrial ganglionated plexus (LSGP), the left inferior ganglionated plexus (LIGP), the right anterior ganglionated plexus (RAGP), and the right inferior ganglionated plexus (RIGP) were targeted. Results Over the study period, beginning on January 31, 2021, 30 consecutive subjects (15 females/15 males) aged 42.9 ± 13.6 years underwent GP ablation. The average subject had 9.5 (± 9.2) episodes of syncope prior to ablation. The average CHADS2-VA2SC score was zero. The average LVEF was 64.8% (± 4.9). Two of the subjects had concomitant ablations, six failed prior medical therapy, and one had a prior pacemaker placed. All of the procedures were done without fluoroscopy. The average follow-up was 604 (± 366) days. There were 8 patients that did not improve symptomatically postfirst ablation. Four of the eight underwent repeat ablation and have subsequently improved. 26/30 patients symptomatically improved after the 1st or 2nd ablation. There were no complications noted. Conclusion In comparison to the traditional CNA with fluoroscopy, this proof of concept study reveals fluoroless GP ablation can be performed safely. In addition, the durability and success rate are comparable to other studies of CNA. Given the young age of the cohort and the longitudinal risks of ionizing radiation, fluoroless CNA is a feasible procedure for this patient population. Graphical Abstract
- 1 August 2024
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 68 (2) , 433-439
Cardioneural ablation—the first case series without the use of fluoroscopy
Introduction Cardioneural ablation (CNA) and fluoroless ablation (FA) are emerging procedures and movements in contemporary in electrophysiology. Ablation of ganglionated plexus (GP) inputs in the atrium has been successfully targeted as a treatment for symptomatic bradyarrhythmias due to increased parasympathetic tone. As most of these patients are young, avoidance of ionizing radiation is of critical importance to limit potential long term deleterious effects. With widespread use of 3D electroanatomic mapping systems and advanced intracardiac echo (ICE) imaging, fluoroless ablation has become more widely adopted. However, fluoroless CNA has not been widely performed. The objective of this study is to demonstrate that CNA can be done safely and effectively without fluoroscopy. Methods At a single-center, consecutive patients undergoing CNA with a fluoroless approach are described. GP mapping and ablation were performed in both atria. From the right atrium (RA), the right atrium-superior vena cava (RA-SVC GP), the posteromedial ganglionated plexus (PMLGP), which can be accessed from the right atrium-coronary sinus ostium, and the Vein of Marshall GP (VOM-GP) were evaluated. From the left atrium (LA), the superior left atrial ganglionated plexus (LSGP), the left inferior ganglionated plexus (LIGP), the right anterior ganglionated plexus (RAGP), and the right inferior ganglionated plexus (RIGP) were targeted. Results Over the study period, beginning on January 31, 2021, 30 consecutive subjects (15 females/15 males) aged 42.9 ± 13.6 years underwent GP ablation. The average subject had 9.5 (± 9.2) episodes of syncope prior to ablation. The average CHADS2-VA2SC score was zero. The average LVEF was 64.8% (± 4.9). Two of the subjects had concomitant ablations, six failed prior medical therapy, and one had a prior pacemaker placed. All of the procedures were done without fluoroscopy. The average follow-up was 604 (± 366) days. There were 8 patients that did not improve symptomatically postfirst ablation. Four of the eight underwent repeat ablation and have subsequently improved. 26/30 patients symptomatically improved after the 1st or 2nd ablation. There were no complications noted. Conclusion In comparison to the traditional CNA with fluoroscopy, this proof of concept study reveals fluoroless GP ablation can be performed safely. In addition, the durability and success rate are comparable to other studies of CNA. Given the young age of the cohort and the longitudinal risks of ionizing radiation, fluoroless CNA is a feasible procedure for this patient population. Graphical Abstract