SWStefan Wentaschek

Stefan Wentaschek

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stefan Wentaschek has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Accuracy, insertion torque and ISQ of keyless versus drill-key guided implant surgery: in vitro comparison of two implant macro-designs in healed ridges and molar extraction sites

    by Malte Bagratuni, Gülce Cakmak, Omar Elattar, Samir Abou-Ayash, Stefan Wentaschek, Florian Beuer, Lauren Bohner, Stefano Pieralli

  • Open Access

    Influence of 3D Printing, Implant Macro-Design and Alveolar Ridge Morphology on Accuracy and Primary Stability in Static Computer-Assisted Implant Surgery: An In Vitro Study

    by Malte Bagratuni, Samir Abou-Ayash, Justus Pook, Stefan Wentaschek, Lauren Bohner, Gülce Cakmak, Florian Beuer, Stefano Pieralli

  • Open Access

    Effect of cold atmospheric pressure plasma on wettability of implant prosthetic materials: an in-vitro study

    by Moataz Bayadse, Leonie Grander, Lisa Steiner, Samir Abou-Ayash, Stefan Wentaschek

    Purpose: Surface wettability is a key factor in bonding of dental materials. The aim of the present study was to investigate the influence of different exposure times of cold atmospheric pressure plasma at constant power on the surface wettability of various dental materials employed in implantology, using the “Piezo-Brush ® ” PZ3 cold atmospheric pressure plasma device. Methods: Seventy-five standardized specimens made of titanium alloy, zirconia, lithium disilicate and polymer-infiltrated hybrid ceramic network were manufactured and polished. Specimens of each material were divided into 5 groups (each n = 15). Four groups were cold atmospheric pressure plasma treated for 5, 10, 20, 30 s and compared to the untreated control group. Surface wettability was assessed by measuring the contact angle of distilled water using a goniometer. Statistical analysis was performed using one-way ANOVA. Results: The mean contact angle was significantly reduced by 60–80% after 5 s of cold atmospheric pressure plasma treatment for all investigated materials ( p < 0.001). Prolonged cold atmospheric pressure plasma exposure resulted in further reduction in mean contact angle values for titanium at each additional treatment duration ( p < 0.001), whereas for lithium disilicate a reduction was observed only up to 10 s. For zirconia and polymer-infiltrated hybrid ceramic network, no further reduction in contact angle was observed beyond 5 s of cold atmospheric pressure plasma treatment. Conclusion: Cold atmospheric pressure plasma treatment significantly increases surface wettability after short exposure times. Within the limitations of this study, these findings may indicate a potential improvement in adhesion behavior. However, under the plasma parameters applied, extending treatment beyond 5 s for zirconia and polymer-infiltrated hybrid ceramic network or beyond 10 s for titanium and lithium disilicate did not result in further reduction of contact angle. The clinical relevance of these findings requires further investigation. Graphical

  • Open Access

    Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study

    by Monika Bjelopavlovic, Michael Weyhrauch, Herbert Scheller, Stefan Wentaschek, Karl Martin Lehmann

    Objectives: This study aimed to determine the retentive strength of monolithic hybrid-all-ceramic crowns luted on titanium implant abutments. Material and Methods: In total, 450 crowns (75 each of Mark II, Empress CAD, e.max CAD, Suprinity, Enamic, Celtra Duo) were milled using a CAD/CAM system. The crowns were cemented onto sandblasted titanium implant abutments using five luting agents (Multilink Implant, Variolink II, RelyX Unicem, Fujicem, and Panavia 2.0). After thermocycling was performed (5000 cycles: 5–55 °C, 30-s dwell time), the crowns were removed using a universal testing machine. The location of luting-agent residue on the abutment and inner crown surfaces was evaluated. Analyses of variance (ANOVA) with the Bonferroni correction were performed to evaluate differences of retentive strength depending on the crown material and the kind of the luting agent. Results: The retentive strengths for the different ceramic materials were Vita Mark II: 652N-759N (SD:134N-146N), Empress CAD: 681N-822N (SD: 89N-146N), e.max CAD: 784N-1044N (SD: 109N-176N), Vita Enamic: 716N-1177N (SD: 132N-220N), Vita Suprinity: 867N-1488N (SD: 202N-278N), and Celtra Duo 772N-1335N (SD:151N-229N). After the removal trials, the visual documentation showed different adhesive residue location depending on the ceramic materials. Furthermore, the pull-off force was dependent on the choice of adhesives. No significant differences were found between different luting agents and the ceramic material Vita Mark II and Empress CAD. EmaxCAD showed significant differences with Unicem and FujiCem compared to Panavia, as did VitaSuprinity, VitaEnamic, and Celtra Duo (p < 0.001). Conclusions: The ceramic material used seems to influence the retentive strength and the use of certain luting agents results in a higher retentive strength for some ceramic materials.


  • Open Access

    Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems

    by Karl Martin Lehmann, Michael Weyhrauch, Monika Bjelopavlovic, Herbert Scheller, Henning Staedt, Peter Ottl, Peer W. Kaemmerer, Stefan Wentaschek

    Background: CAD/CAM systems enable the production of fixed partial dentures with small and reproducible internal and marginal gaps. Purpose: The purpose of this study was to evaluate the reproducibility of the marginal and internal adaptations of four-unit fixed partial denture frameworks produced using four CAD/CAM systems. Materials and Methods: Prepared dies of a master model that simulated the loss of the first left molar were measured. Fifteen frameworks were manufactured using four CAD/CAM systems (A–D). The internal fit was determined by the replica technique, and the marginal gap was determined by microscopy. ANOVA was carried out to detect significant differences, and the Bonferroni adjustment was performed. The global level of significance was set at 5%. Results: The mean gap size ranged from 84 to 132 µm (SD 43–71 µm). The CAD/CAM systems showed significant variance (p < 0.001), and system A (VHF) showed the smallest gaps. The smallest gaps for each system were in the molar part and in the marginal region of the frameworks (p < 0.001). Conclusions: The CAD/CAM systems showed significantly different gap sizes, particularly between premolars and molars and among the marginal, axial and occlusal regions. All of the systems are suitable for clinical application.


  • Open Access

    Six-implant-supported immediate fixed rehabilitation of atrophic edentulous maxillae with tilted distal implants

    by S. Wentaschek, S. Hartmann, C. Walter, W. Wagner

    The aim of this retrospective study was to evaluate the treatment outcome of six Bredent blueSky™ implants (Bredent GmbH, Senden, Germany) immediately loaded with a fixed full-arch prosthesis (two tilted posterior and four axial frontal and premolar implants). All 10 patients with atrophic edentulous maxillae being treated with a standardized procedure from 09/2009 to 01/2013, who had a follow-up of at least 3 years, were included. Sixty implants were placed to support 10 screwed prostheses. Twenty-one of them were inserted in fresh extraction sockets. Lab-side-prepared provisional fixed prostheses were placed at the day of implantation. Periotest (PT) values and implant stability quotient (ISQ) were measured after implant surgery and after 3 months of healing in all patients. The analyzed implants were in function in mean 64 ± 13 months (range 42 to 84 months). One axial and two tilted implants failed in three patients. The mean PT values decreased, and ISQ increased significantly after the first 3 months at the osseointegrated tilted and axial implants. With an area under the curve of 0.503 and 0.506 in the receiver operating characteristic, the PT values and the ISQ were unspecific parameters and unsuitable as a predictor for the risk of non-osseointegration. Within the limits of this small group (n = 10 patients/60 implants), the failure rate of the analyzed implant system (n = 3 respective 5% implant loss) seems to be comparable with other immediate-loading protocols. The failure rate of tilted implants in the atrophic upper jaw was quite high, but the aimed treatment concept could be achieved in every patient. The rehabilitation of the posterior region in edentulous maxilla remains a challenge.


  • Polygonal Area of Prosthesis Support with Straight and Tilted Dental Implants in Edentulous Maxillae

    by Stefan Wentaschek, Karl Lehmann, Herbert Scheller, Gernot Weibrich, Nikolaus Behneke

    Stefan Wentaschek, DMD, MSc/Karl Martin Lehmann, DMD, PhD/Herbert Scheller, DMD, PhD/Gernot Weibrich, MD, DMD, PhD/Nikolaus Behneke, DMD, PhD: Purpose: The aim of this in vitro study was to assess the increase in the polygonal area of implant-retained prosthesis supports in edentulous maxillae with the use of tilted distal implants compared with the use of straight distal implants, using a variety of implant lengths. Materials and Methods: A total of 25 DICOM datasets of atrophic edentulous maxillae were provided. Bone augmentations in the molar region had to be avoided. Two straight reference implants were virtually inserted in the anterior region. Two additional implants were placed far distally on both sides (4 groups: [1] straight, 12-mm length; [2] straight, 10 mm; [3] straight, 8 mm; [4] tilted, 12?16 mm). The resulting implant-supported polygon was measured for each of the 4 groups using three-dimensional planning software. Results: The mean sagittal depth of the supported polygon in Group 1 was 9.9 mm (standard deviation [SD] 4.4) on the right and 10.2 mm (SD 4.4) on the left, and it was 33.7 mm (SD 5.8) in width. For Group 2, the mean sagittal depth was 11.5 mm (SD 5.0) on the right and 11.9 mm (SD 4.7) on the left, and the width was 35.2 mm (SD 5.6). The measurements for Group 3 were 13.8 mm (SD 4.9) deep on the right, 13.8 mm (SD 5.1) deep on the left, and 37.0 mm (SD 5.4) in width. For Group 4, the depth was 15.8 mm (SD 4.9) on the right and 16.4 mm (SD 5.8) on the left, and the width was 39.0 mm (SD 5.1). Conclusion: The area of implant-retained prosthesis support can be enlarged by the use of tilted implants (12 to 16 mm in length, 42 to 45 degrees) compared to the use of straight 8-mm implants (resulting increase: about 15%).


  • Sensitivity and Specificity of Stability Criteria for Immediately Loaded Splinted Maxillary Implants

    by Stefan Wentaschek, Herbert Scheller, Irene Schmidtmann, Sinsa Hartmann, Michael Weyhrauch, Gernot Weibrich, Karl Martin Lehmann

    Background: To assess the suitability of dental implants for immediate loading, primary stability is usually evaluated intraoperatively.Purpose: This retrospective study aimed to assess the suitability of three stability parameters – namely, insertion torque (IT), implant stability quotient (ISQ; measured by resonance frequency analysis), and Periotest (PT) values – as potential predictors for the risk of nonosseointegration of immediately loaded splinted implants. The stability parameters were routinely collected under immediate loading.Materials and Methods: Nineteen patients with 11 edentulous and 8 partially edentulous maxillae were treated with 105 dental implants, which were immediately loaded using temporary fixed dentures. The IT results, PT values, and ISQ results were recorded. Receiver operating characteristic analysis was performed to assess the quality of each parameter as a diagnostic test.Results: After a 3‐month observation period, 11 implants in four patients were not osseointegrated. The IT and ISQ (IT 25.0 ± 12.5 Ncm and 8.4 ± 2.3 Ncm; PT −1.5 ± 3.0 and +2.7 ± 3.0; and ISQ 62.6 ± 6.7 and 54.7 ± 6.2) differed significantly between the osseointegrated and failed implants (p < .005). The IT showed the greatest specificity at a sensitivity of 1 and the greatest area under the curve (AUC; 0.929), followed by the PT value (AUC = 0.836) and ISQ (AUC = 0.811).Conclusions: Among the intraoperative parameters analyzed, IT showed the highest specificity at a high sensitivity of 1. Therefore, the IT can be considered the most valid prognostic factor for osseointegration of immediately loaded splinted dental implants.