EVEnrico Verroi

Enrico Verroi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Enrico Verroi has a total of 133 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Direct measurement of relative stopping power maps of prosthesis devices and synthetic materials by proton computed tomography

    by Mara Bruzzi, Monica Scaringella, Roberto Righetto, Elena Fogazzi, Francesco Fracchiolla, Francesco Tommasino, Enrico Verroi, Stefano Lorentini, Carlo Civinini

    Objective. Treatment planning in proton therapy requires an accurate estimation of stopping power ratio relative to water (SPR) maps. Presently, about 4% of patients submitted to radiotherapy treatments have metallic implants, which are responsible for an incorrect determination of SPRs in prostheses and surrounding regions. This study presents the first application of the proton computed tomography (pCT) technique, able to directly measure SPRs maps, on complex metallic implants. Approach. A homogeneous Ti6Al4V alloy sample, a set of metallic devices used for prostheses and an intra-vertebral titanium alloy implant have been inspected, by means of a prototype pCT system with a 5 × 20 cm 2 field-of-view (FoV) developed by INFN Firenze (Italy), under a proton beam at Trento Proton Therapy Centre (APSS, Trento, Italy). For comparison, a Multi Layer Ionization Chamber (MLIC) has been used to independently determine the SPR mean value of the Ti6Al4V alloy sample. Main Results. Tomographic reconstructions of all devices and materials have been performed and SPR maps have been obtained. All pCT images and profiles, even of metallic components, are characterized by negligible artifacts. The fine spatial resolution of our pCT system, about 0.7 lp mm −1 , allowed us to resolve details within a millimeter scale. The internal grid of the meshed cage as well as details of the screws’ head of the intra-vertebral titanium alloy implant are clearly visible. The SPR of the Ti6Al4V alloy sample measured with pCT, 3.14 ± 0.02, compares well with what was measured by MLIC: 3.17 ± 0.02. Significance. This study presents the first application of the pCT methodology to directly measure SPR maps of complex metal prostheses. The ability of pCT to correctly determine mean SPR values has been experimentally demonstrated. Furthermore, this technique was shown to reconstruct complex metal structures at the millimeter scale with negligible artifacts.


  • Open Access

    A Nanosatellite-Sized Detector for Sub-MeV Charged Cosmic Ray Fluxes in Low Earth Orbit: The Low-Energy Module (LEM) Onboard the NUSES Space Mission

    by Riccardo Nicolaidis, Andrea Abba, Domenico Borrelli, Adriano Di Giovanni, Luigi Ferrentino, Giovanni Franchi, Francesco Nozzoli, Giancarlo Pepponi, Lorenzo Perillo, David Schledewitz, et al.

    NUSES is a planned space mission aiming to test new observational and technological approaches related to the study of low-energy cosmic rays, gamma rays, and high-energy astrophysical neutrinos. Two scientific payloads will be hosted onboard the NUSES space mission: Terzina and Zirè. Terzina will be an optical telescope readout by SiPM arrays for the detection and study of Cerenkov light emitted by Extensive Air Showers (EASs) generated by high-energy cosmic rays and neutrinos in the atmosphere. Zirè will focus on the detection of protons and electrons up to a few hundred MeV and 0.1–30 MeV photons and will include the Low-Energy Module (LEM). The LEM will be a particle spectrometer devoted to the observation of fluxes of low-energy electrons in the 0.1–7-MeV range and protons in the 3–50 MeV range in low Earth orbit (LEO) followed by the hosting platform. The detection of Particle Bursts (PBs) in this physics channel of interest could provide insights into understanding complex phenomena such as possible correlations between seismic events or volcanic activity with the collective motion of particles in the plasma populating Van Allen belts. With its compact size and limited acceptance, the LEM will allow the exploration of hostile environments such as the South Atlantic Anomaly (SAA) and the inner Van Allen belt, in which the anticipated electron fluxes are on the order of 106 to 107 electrons per square centimeter per steradian per second. Concerning the vast literature on space-based particle spectrometers, the innovative aspect of the LEM resides in its compactness, within 10×10×10 cm3, and in its “active collimation” approach to dealing with the problem of multiple scattering at these low energies. In this work, the geometry of the detector, its detection concept, its operation modes, and the hardware adopted will be presented. Some preliminary results from a Monte Carlo simulation (Geant4) will be shown.

  • Open Access

    A New Measurement of Light Yield Quenching in EJ-200 and LYSO Scintillators

    by Francesco Dimiccoli, Francesco Maria Follega, Luigi Ernesto Ghezzer, Roberto Iuppa, Alessandro Lega, Riccardo Nicolaidis, Francesco Nozzoli, Ester Ricci, Enrico Verroi, Paolo Zuccon

    Lutetium–Yttrium Oxyorthosilicate (LYSO) crystals and EJ-200 plastic scintillators are widely recognized fast scintillating materials, valued for their high light yield and mechanical robustness, which make them well suited for demanding applications in high-energy physics and space research. Their non-proportional light response, along with their non-linear behavior at low-energy X-rays, has been extensively investigated in previous studies, revealing potential systematic effects in existing measurements. In this work, light quenching in both scintillators is measured under charged-particle excitation. The results are interpreted using the modified Birks–Onsager model, which provides a theoretical framework for understanding the underlying quenching mechanisms, as well as a generalized logistic parametrization, offering experimentalists a useful tool to characterize the detector’s light yield and associated uncertainties.


  • Open Access

    High-Efficiency WLS Plastic for a Compact Cherenkov Detector

    by Francesco Nozzoli, Luigi Ernesto Ghezzer, Francesco Bruni, Daniele Corti, Francesco Meinardi, Riccardo Nicolaidis, Leonardo Ricci, Piero Spinnato, Enrico Verroi, Paolo Zuccon

    The Cherenkov effect, whereby a charged particle emits light when traveling faster than the phase velocity of light in a dielectric medium, is widely employed in particle identification techniques. However, Cherenkov light yield is relatively low, typically amounting to only 100–200 visible photons per centimeter of path length in materials like water, plastic, or glass. In this study, we investigate the optical response of FB118, a wavelength-shifting (WLS) plastic developed by Glass to Power, under exposure to ionizing particles. Our measurements confirm the absence of residual scintillation in FB118, allowing for a clean separation of Cherenkov signals. Moreover, the intrinsic WLS properties of the material enable a significant enhancement of light detection in the visible range. These features make FB118 a promising candidate for use in compact Cherenkov detectors, particularly in astroparticle physics experiments where space and power constraints demand efficient, compact solutions.


  • Open Access

    Investigating the Influence of Conventional vs. Ultra-High Dose Rate Proton Irradiation Under Normoxic or Hypoxic Conditions on Multiple Developmental Endpoints in Zebrafish Embryos

    by Alessia Faggian, Gaia Pucci, Enrico Verroi, Alberto Fasolini, Stefano Lorentini, Sara Citter, Maria Caterina Mione, Marco Calvaruso, Giorgio Russo, Emanuele Scifoni, et al.

    Objectives: To investigate how the FLASH effect modulates radiation response on multiple developmental endpoints of zebrafish embryos under normoxic and hypoxic conditions, after irradiation with proton beams at a conventional and an ultra-high dose rate (UHDR). Methods: Embryos were obtained from adult zebrafish and irradiated with a 228 MeV proton beam 24 h post-fertilization (hpf) at a dose rate of 0.6 and 317 Gy/s. For the hypoxic group, samples were kept inside a hypoxic chamber prior to irradiation, while standard incubation was adopted for the normoxic group. After irradiation, images of single embryos were acquired, and radiation effects on larval length, yolk absorption, pericardial edema, head size, eye size, and spinal curvature were assessed at specific time points. Results: Data indicate a general trend of significantly reduced toxicity after exposure to a UHDR compared to conventional regimes, which is maintained under both normoxic and hypoxic conditions. Differences are significant for the levels of pericardial edema induced by a UHDR versus conventional irradiation in normoxic conditions, and for eye and head size in hypoxic conditions. The toxicity scoring analysis shows a tendency toward a protective effect of the UHDR, which appears to be associated with a lower percentage of embryos in the high score categories. Conclusions: A radioprotective effect at a UHDR is observed both for normoxic (pericardial edema) and hypoxic (head and eye size) conditions. These results suggest that while the UHDR may preserve a potential to reduce radiation-induced damage, its protective effects are endpoint-dependent; the role of oxygenation might also be dependent on the tissue involved.


  • Open Access

    New measurements of light yield quenching in EJ-200 and LYSO scintillators

    by A. Lega, R. Nicolaidis, F. Nozzoli, F. Dimiccoli, F.M. Follega, L.E. Ghezzer, R. Iuppa, E. Ricci, E. Verroi, P. Zuccon


  • Open Access

    Antideuteron Identification in Space with Helium Calorimeter

    by Francesco Nozzoli, Irina Rashevskaya, Leonardo Ricci, Francesco Rossi, Piero Spinnato, Enrico Verroi, Paolo Zuccon, Gregorio Giovanazzi

    The search for low-energy antideuterons in cosmic rays allows the addressing of fundamental physics problems testing for the presence of primordial antimatter and the nature of Dark Matter. The PHeSCAMI (Pressurized Helium Scintillating Calorimeter for AntiMatter Identification) project aims to exploit the long-living metastable states of the helium target for the identification of low-energy antideuterons in cosmic rays. A space-based pressurized helium calorimeter would provide a characteristic identification signature based on the coincident detection of a prompt scintillation signal emitted by the antideuteron energy loss during the slowing-down phase in the gas, and the (≈µs) delayed scintillation signal provided by the charged pions produced in the subsequent annihilation. The performance of a high-pressure (200-bar) helium scintillator prototype, tested in the INFN-TIFPA laboratory, will be summarized.


  • Open Access

    Performance of LGAD strip detectors for particle counting of therapeutic proton beams

    by Vincenzo Monaco, Omar Hammad Ali, Davide Bersani, Mohammed Abujami, Maurizio Boscardin, Nicolò Cartiglia, Gian Franco Dalla Betta, Emanuele Data, Marco Donetti, Marco Ferrero, et al.

    Objective . The performance of silicon detectors with moderate internal gain, named low-gain avalanche diodes (LGADs), was studied to investigate their capability to discriminate and count single beam particles at high fluxes, in view of future applications for beam characterization and on-line beam monitoring in proton therapy. Approach . Dedicated LGAD detectors with an active thickness of 55 μ m and segmented in 2 mm 2 strips were characterized at two Italian proton-therapy facilities, CNAO in Pavia and the Proton Therapy Center of Trento, with proton beams provided by a synchrotron and a cyclotron, respectively. Signals from single beam particles were discriminated against a threshold and counted. The number of proton pulses for fixed energies and different particle fluxes was compared with the charge collected by a compact ionization chamber, to infer the input particle rates. Main results . The counting inefficiency due to the overlap of nearby signals was less than 1% up to particle rates in one strip of 1 MHz, corresponding to a mean fluence rate on the strip of about 5 × 10 7 p/(cm 2 ·s). Count-loss correction algorithms based on the logic combination of signals from two neighboring strips allow to extend the maximum counting rate by one order of magnitude. The same algorithms give additional information on the fine time structure of the beam. Significance . The direct counting of the number of beam protons with segmented silicon detectors allows to overcome some limitations of gas detectors typically employed for beam characterization and beam monitoring in particle therapy, providing faster response times, higher sensitivity, and independence of the counts from the particle energy.


  • Open Access

    Epitaxial SiC Dosimeters and Flux Monitoring Detectors for Proton Therapy Beams

    by Mara Bruzzi, Enrico Verroi

    The exceptional optoelectronic properties and high radiation resistance of epitaxial silicon carbide make this material attractive for high-energy beam dosimetry and radiation monitoring, especially when strict requirements such as high signal-to-noise ratios, high time and spatial resolutions and low detectivity levels are required. A 4H-SiC Schottky diode has been characterized as a proton-flux-monitoring detector and dosimeter under proton beams for proton therapy. The diode was composed of an epitaxial film grown on 4H-SiC n+-type substrate equipped with a gold Schottky contact. The diode was embedded in a tissue-equivalent epoxy resin and then characterized in terms of capacitance vs. voltage (C-V) and current vs. voltage (I-V) characteristics in the dark in the range of 0–40 V. The dark currents at room temperature are in the order of 1 pA, while the doping and active thicknesses extracted from the C-V are 2.5 × 1015 cm−3 and 2–4 μm, respectively. Proton beam tests have been carried out at the Proton Therapy Center of the Trento Institute for Fundamental Physics and Applications (TIFPA-INFN). They have been carried out with energies and extraction currents of 83–220 MeV and 1–10 nA, respectively, as typical for proton therapy applications, corresponding to dose rates in the range of 5 mGy/s to 2.7 Gy/s. The I-V characteristics measured under proton beam irradiation at the lowest dose rate showed a typical diode photocurrent response and a signal-to-noise ratio well above 10. Investigations with null bias evidenced a very good performance in terms of the diode’s sensitivity, fast rise and decay times and response stability. The diode’s sensitivity was in agreement with the expected theoretical values, and its response was linear throughout the whole investigated dose rate range.


  • Open Access

    Study of SEU effects in circuits developed in 110 nm CMOS technology

    by Daniela Calvo, Paolo DE Remigis, Maria Fisichella, Richard Wheadon, André Zambanini, Serena Mattiazzo, Enrico Verroi, Francesco Tommasino

    Channel configuration registers of a full size prototype for the custom readout circuit of silicon double-sided microstrips of PANDA Micro Vertex Detector were tested for upset effects. The ASIC is developed in a commercial 110 nm CMOS technology and implements both Triple Modular Redundancy and Hamming Encoding techniques. Results from tests with ion and proton beams show the robustness level of these two techniques against the upset effects and allow the evaluation of that commercial 110 nm technology in the PANDA experiment.