Muthuraman Subbiah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Muthuraman Subbiah has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Sivaraj Murugan
Department of Mechanical Engineering, Institute of Technology, Hawassa University, Hawassa, Ethiopia
3 shared publications - Abdul Mutalib Leman
Universiti Tun Hussein Onn Malaysia
1 shared publication - Aissa Nasser Kri̇zOu
Higher College of Technology
1 shared publication Apurba Layek
1 shared publication- Hafiz Zafar Sharif
Universiti Tun Hussein Onn Malaysia
1 shared publication Kumar Ayyappan
Department of Applied Sciences, Amrita College of Engineering and Technology, TN- India
1 shared publication
Latest Publications
- Open Access
- 13 July 2025
- Published by Academic Publishing Pte. Ltd. in Building Engineering
- Vol. 3 (3)
Evaluation of the microbiological indoor air quality at a commercial building in Muscat, Oman, utilizing an all-air multi-zone HVAC system
This study evaluates the microbiological indoor air quality (IAQ) of a commercial office building in Muscat, Oman, equipped with an all-air multi-zone heating, ventilation, and air-conditioning (HVAC) system operating under hot-arid climatic conditions. Active air sampling was conducted at multiple locations, including open-plan offices, outdoor air intake, supply air diffusers, fan coil units, and the humidification water tank of the air handling unit (AHU), across different seasons. Airborne bacteria were analyzed using incubation at 22 ℃ and 37 ℃ to distinguish environmental and human-associated microbial populations, while fungal concentrations were assessed at 25 ℃, with results expressed as colony-forming units per cubic meter (CFU/m3). For analytical consistency, data from the three office spaces investigated were aggregated and evaluated as seasonal averages. Bacterial concentrations in indoor air generally ranged from 32 to 496 CFU/m3 at 37 ℃ and 4 to 500 CFU/m3 at 22 ℃, indicating low to moderate contamination levels under normal operating conditions. In contrast, a pronounced increase in fungal concentrations was observed during the initial winter sampling, exceeding 2000 CFU/m3, which was attributed to an exceptional flooding event. Comparative analysis of outdoor air, AHU-treated air, and indoor air demonstrated that the HVAC system effectively reduced microbial loads during standard climatic conditions. The findings provide region-specific baseline data on microbiological IAQ and highlight the influence of HVAC operation, seasonal variation, and extreme environmental events on indoor bioaerosol levels in commercial buildings located in hot-arid climates.
- 13 July 2025
- Published by Academic Publishing Pte. Ltd. in Building Engineering
- Vol. 3 (3)
Open AccessEvaluation of the microbiological indoor air quality at a commercial building in Muscat, Oman, utilizing an all-air multi-zone HVAC system
This study evaluates the microbiological indoor air quality (IAQ) of a commercial office building in Muscat, Oman, equipped with an all-air multi-zone heating, ventilation, and air-conditioning (HVAC) system operating under hot-arid climatic conditions. Active air sampling was conducted at multiple locations, including open-plan offices, outdoor air intake, supply air diffusers, fan coil units, and the humidification water tank of the air handling unit (AHU), across different seasons. Airborne bacteria were analyzed using incubation at 22 ℃ and 37 ℃ to distinguish environmental and human-associated microbial populations, while fungal concentrations were assessed at 25 ℃, with results expressed as colony-forming units per cubic meter (CFU/m3). For analytical consistency, data from the three office spaces investigated were aggregated and evaluated as seasonal averages. Bacterial concentrations in indoor air generally ranged from 32 to 496 CFU/m3 at 37 ℃ and 4 to 500 CFU/m3 at 22 ℃, indicating low to moderate contamination levels under normal operating conditions. In contrast, a pronounced increase in fungal concentrations was observed during the initial winter sampling, exceeding 2000 CFU/m3, which was attributed to an exceptional flooding event. Comparative analysis of outdoor air, AHU-treated air, and indoor air demonstrated that the HVAC system effectively reduced microbial loads during standard climatic conditions. The findings provide region-specific baseline data on microbiological IAQ and highlight the influence of HVAC operation, seasonal variation, and extreme environmental events on indoor bioaerosol levels in commercial buildings located in hot-arid climates.
- Open Access
- 30 June 2025
- Published by University of Chemistry and Technology - Faculty of Environmental Technology in Paliva
- p. 20-26
Experimental studies on CI engine performance ad emission usingneem-based biodiesel as an alternative fuel
The depletion of fossil fuels and increasing greenhouse gas emissions have intensified interest in biodiesel as a feasible substitute for fossil fuels. Biodiesel has multiple benefits, such as its renewability and reduced emissions of toxic exhaust upon combustion. This study examines the generation of Neem seed biodiesel and its impact on the performance of compression ignition (CI) engines when combined with pure diesel. The biodiesel was produced by the transesterification process. Transesterification occurred in two phases: acid catalysis and base catalysis. Three unique blends were produced by amalgamating neem biodiesel with pure diesel (B10, B15, and B20). The performance of various combinations was evaluated and contrasted with that of pure diesel. As the load increased, the brake thermal efficiency and specific fuel consumption of all blends enhanced. Hydrocarbons, carbon monoxide, and smoke opacity were diminished in comparison to pure diesel. Nitrogen oxides increased with load in all mixes relative to pure diesel. This study indicates that neem-based biodiesel serves as a viable alternative to conventional diesel.
- 30 June 2025
- Published by University of Chemistry and Technology - Faculty of Environmental Technology in Paliva
- p. 20-26
Open AccessExperimental studies on CI engine performance ad emission usingneem-based biodiesel as an alternative fuel
The depletion of fossil fuels and increasing greenhouse gas emissions have intensified interest in biodiesel as a feasible substitute for fossil fuels. Biodiesel has multiple benefits, such as its renewability and reduced emissions of toxic exhaust upon combustion. This study examines the generation of Neem seed biodiesel and its impact on the performance of compression ignition (CI) engines when combined with pure diesel. The biodiesel was produced by the transesterification process. Transesterification occurred in two phases: acid catalysis and base catalysis. Three unique blends were produced by amalgamating neem biodiesel with pure diesel (B10, B15, and B20). The performance of various combinations was evaluated and contrasted with that of pure diesel. As the load increased, the brake thermal efficiency and specific fuel consumption of all blends enhanced. Hydrocarbons, carbon monoxide, and smoke opacity were diminished in comparison to pure diesel. Nitrogen oxides increased with load in all mixes relative to pure diesel. This study indicates that neem-based biodiesel serves as a viable alternative to conventional diesel.
- Open Access
- 1 April 2020
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 6 (3) , 346-358
ANALYSIS OF NEARLY ZERO ENERGY RESIDENTIAL BUILDING IN MUSCAT
The building sector is the largest consumer of the primary sources of energy worldwide. The most commonly used primary sources of energy to generate electricity are oil, coal, peat, shale, natural gas, nuclear, hydro, renewables, biofuels, and waste. The energy demand by the building sector is about 40% of the world’s energy production.Net Zero Energy Buildings (NZEBs) is the best solution recommended by the energy experts to reduce substantial pressure on primary sources of energy contributed by the building sector. There is a marginal gap between estimates made during the design stage and actual energy performance of residential buildings, primarily due to a lack of understanding of the factors affecting energy use and whole building simulations software limitations. The purpose of this research work was to conduct a comparative analysis of a predicted versus actual energy consumption of prototype Net Zero Energy Building (NZEB) constructed at Higher College of Technology, Muscat. Hourly Analysis Program (HAP V4.2) was used to predict energy demand of NZEB at HCT and same size regular house in Muscat. PVWatts calculator was used to determining possible power generation by the PV system installed on the roof in the form of a canopy. The constructed house was tested for one month to perform multiple tasks as per competition requirements in which one of the major tasks was to produce onsite energy production by PV panel’s equivalent to the energy consumed by the house. The actual energy consumption results were compared with the simulated result and observed that actual energy demand of house was approximately 20% lower than that predicted by the simulation tool. The comparison of simulation results between NZEB and regular house indicated 61.24 % less energy demand of NZEB, mainly due to less HVAC load. The simulation result for BEI of NZEB showed 87.20 kWh/m2/year as compare to 225.1 kWh/m2/year for same size regular house. The simulated result obtained from PVWatts calculator for competition period and actual production of an installed PV system at the top roof showed a minor deviation of 0.73% only. It is also observed from the results during the competition period house exported 1221 kWh energy to the grid.
- 1 April 2020
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 6 (3) , 346-358
Open AccessANALYSIS OF NEARLY ZERO ENERGY RESIDENTIAL BUILDING IN MUSCAT
The building sector is the largest consumer of the primary sources of energy worldwide. The most commonly used primary sources of energy to generate electricity are oil, coal, peat, shale, natural gas, nuclear, hydro, renewables, biofuels, and waste. The energy demand by the building sector is about 40% of the world’s energy production.Net Zero Energy Buildings (NZEBs) is the best solution recommended by the energy experts to reduce substantial pressure on primary sources of energy contributed by the building sector. There is a marginal gap between estimates made during the design stage and actual energy performance of residential buildings, primarily due to a lack of understanding of the factors affecting energy use and whole building simulations software limitations. The purpose of this research work was to conduct a comparative analysis of a predicted versus actual energy consumption of prototype Net Zero Energy Building (NZEB) constructed at Higher College of Technology, Muscat. Hourly Analysis Program (HAP V4.2) was used to predict energy demand of NZEB at HCT and same size regular house in Muscat. PVWatts calculator was used to determining possible power generation by the PV system installed on the roof in the form of a canopy. The constructed house was tested for one month to perform multiple tasks as per competition requirements in which one of the major tasks was to produce onsite energy production by PV panel’s equivalent to the energy consumed by the house. The actual energy consumption results were compared with the simulated result and observed that actual energy demand of house was approximately 20% lower than that predicted by the simulation tool. The comparison of simulation results between NZEB and regular house indicated 61.24 % less energy demand of NZEB, mainly due to less HVAC load. The simulation result for BEI of NZEB showed 87.20 kWh/m2/year as compare to 225.1 kWh/m2/year for same size regular house. The simulated result obtained from PVWatts calculator for competition period and actual production of an installed PV system at the top roof showed a minor deviation of 0.73% only. It is also observed from the results during the competition period house exported 1221 kWh energy to the grid.
- 1 August 2016
- Published by Elsevier in Applied Thermal Engineering
- Vol. 107, 625-632
Microstructure characterization and thermal properties of Al-TiC sintered nano composites
- 1 August 2016
- Published by Elsevier in Applied Thermal Engineering
- Vol. 107, 625-632
Microstructure characterization and thermal properties of Al-TiC sintered nano composites
- Open Access
- 1 June 2016
- Published by Elsevier in Engineering Science and Technology, an International Journal
- Vol. 19 (2) , 1018-1026
Exploration of waste cooking oil methyl esters (WCOME) as fuel in compression ignition engines: A critical review
- 1 June 2016
- Published by Elsevier in Engineering Science and Technology, an International Journal
- Vol. 19 (2) , 1018-1026
Open AccessExploration of waste cooking oil methyl esters (WCOME) as fuel in compression ignition engines: A critical review
- Open Access
- 9 March 2012
- Published by IntechOpen
The Characteristics of Brazed Plate Heat Exchangers with Different Chevron Angles
The Characteristics of Brazed Plate Heat Exchangers with Different Chevron Angles | InTechOpen, Published on: 2012-03-09. Authors: M. Subbiah
- 9 March 2012
- Published by IntechOpen
Open AccessThe Characteristics of Brazed Plate Heat Exchangers with Different Chevron Angles