Serhii S. Rudenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Serhii S. Rudenko has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Denys G. Koliushko
Національний технічний університет «Харківський політехнічний інститут», м. Харків, Україна
22 shared publications - A. N. Saliba
TMC Group
3 shared publications Oleksandr Istomin
3 shared publicationsG. M. Koliushko
НИПКИ «Молния» Национальный технический университет «Харьковский политехнический институт
2 shared publications- O. Ye. Istomin
National technical university «Kharkiv polytechnic institute
2 shared publications - Oleg Glebov2 shared publications
Latest Publications
- Open Access
- 2 April 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 1(27),p. 127-134
DISTRIBUTION OF HIGH POTENTIALS IN A PV PLANT – SUBSTATION SYSTEM UNDER FAULT CONDITIONS
The research investigates the features of generation and transfer of electric potentials in a system of spatially adjacent electrical installations galvanically interconnected by power cable lines, using a 150/10 kV substation and a photovoltaic power plant as a case study. The relevance of the study is driven by the wide deployment of the Smart Grid concept and Ukraine’s transition toward a hybrid power system combining the interconnected power system with distributed generation based on renewable energy sources. This transition results in the formation of complex non-equipotential grounding systems, which may be exposed to emergency electromagnetic disturbances affecting the operation of sensitive microprocessor-based equipment and personnel safety. The distribution of touch voltage and grounding system potential under single-phase-to-ground faults and direct lightning strikes is analyzed for different geo-electrical soil structures. A simulation model of a real substation grounding system is developed, considering its topology, the parameters of a three-layer soil, and galvanic connections with the grounding system of the PV plant. The adequacy of the proposed model is confirmed by comparing numerical simulation results with experimental measurements. Four types of three-layer soil differing in the relationship between layer resistivities are analyzed, and a correlation between the geo-electrical soil structure and the levels of hazardous potentials is established. It is shown that, under single-phase ground faults, exceedance of permissible touch voltage limits at the substation site is possible for soils of types H and Q, whereas the corresponding values at the PV plant remain within safe limits. In the case of a direct lightning strike, a pronounced localization of extreme potentials is observed in the immediate current injection area, accompanied by a significant reduction of potential levels at the remote installation. The obtained results are of practical importance for assessing the electromagnetic robustness of modern power facilities, selecting technical solutions for grounding and lightning protection, and improving the reliability of secondary and measuring circuits in complex power supply systems.
- 2 April 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 1(27),p. 127-134
Open AccessDISTRIBUTION OF HIGH POTENTIALS IN A PV PLANT – SUBSTATION SYSTEM UNDER FAULT CONDITIONS
The research investigates the features of generation and transfer of electric potentials in a system of spatially adjacent electrical installations galvanically interconnected by power cable lines, using a 150/10 kV substation and a photovoltaic power plant as a case study. The relevance of the study is driven by the wide deployment of the Smart Grid concept and Ukraine’s transition toward a hybrid power system combining the interconnected power system with distributed generation based on renewable energy sources. This transition results in the formation of complex non-equipotential grounding systems, which may be exposed to emergency electromagnetic disturbances affecting the operation of sensitive microprocessor-based equipment and personnel safety. The distribution of touch voltage and grounding system potential under single-phase-to-ground faults and direct lightning strikes is analyzed for different geo-electrical soil structures. A simulation model of a real substation grounding system is developed, considering its topology, the parameters of a three-layer soil, and galvanic connections with the grounding system of the PV plant. The adequacy of the proposed model is confirmed by comparing numerical simulation results with experimental measurements. Four types of three-layer soil differing in the relationship between layer resistivities are analyzed, and a correlation between the geo-electrical soil structure and the levels of hazardous potentials is established. It is shown that, under single-phase ground faults, exceedance of permissible touch voltage limits at the substation site is possible for soils of types H and Q, whereas the corresponding values at the PV plant remain within safe limits. In the case of a direct lightning strike, a pronounced localization of extreme potentials is observed in the immediate current injection area, accompanied by a significant reduction of potential levels at the remote installation. The obtained results are of practical importance for assessing the electromagnetic robustness of modern power facilities, selecting technical solutions for grounding and lightning protection, and improving the reliability of secondary and measuring circuits in complex power supply systems.
- Open Access
- 20 July 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 2(24),p. 124-129
EXPERIMENTAL DETERMINATION OF ELECTROMAGNETIC INTERFERENCE LEVELS IN SECONDARY CIRCUITS OF INSTRUMENT TRANSFORMERS UNDER LIGHTNING STRIKE CONDITIONS
The results of an experimental study on the level of electromagnetic interference in the secondary circuits of voltage and current measuring transformers during the simulation of a direct lightning strike to lightning rods located on the territory of an operational substation are presented. Attention is focused on the issue of overvoltages caused by the dissipation of lightning currents through the grounding system and their impact on the insulation of secondary circuit cables. It is shown that the resulting voltages under such conditions may exceed the permissible limits defined by regulatory standards, including IEC 61000-2-5, by several times, reaching tens of kilovolts while the allowable level is 4000 V. A method for simulating lightning current on a live power facility using an aperiodic impulse generator is discussed, which allows the reproduction of pulse front and duration with parameters 1.2/50 µs at an amplitude of 1000 V. The proposed method was tested at a 330/35/10 kV substation for various current circuit configurations and lightning rod locations. Measurement results of current and voltage in secondary circuits are provided along with recalculated values based on a probable lightning current. It is demonstrated that the highest overvoltages occur in circuits grounded in the main control panel. The obtained results help assess the risk of insulation breakdown due to direct lightning strikes and justify the implementation of additional protective measures. The developed approach can be further applied to improve methods for evaluating and ensuring electromagnetic compatibility of energy infrastructure facilities, particularly in the context of digitalization and SmartGrid deployment.
- 20 July 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 2(24),p. 124-129
Open AccessEXPERIMENTAL DETERMINATION OF ELECTROMAGNETIC INTERFERENCE LEVELS IN SECONDARY CIRCUITS OF INSTRUMENT TRANSFORMERS UNDER LIGHTNING STRIKE CONDITIONS
The results of an experimental study on the level of electromagnetic interference in the secondary circuits of voltage and current measuring transformers during the simulation of a direct lightning strike to lightning rods located on the territory of an operational substation are presented. Attention is focused on the issue of overvoltages caused by the dissipation of lightning currents through the grounding system and their impact on the insulation of secondary circuit cables. It is shown that the resulting voltages under such conditions may exceed the permissible limits defined by regulatory standards, including IEC 61000-2-5, by several times, reaching tens of kilovolts while the allowable level is 4000 V. A method for simulating lightning current on a live power facility using an aperiodic impulse generator is discussed, which allows the reproduction of pulse front and duration with parameters 1.2/50 µs at an amplitude of 1000 V. The proposed method was tested at a 330/35/10 kV substation for various current circuit configurations and lightning rod locations. Measurement results of current and voltage in secondary circuits are provided along with recalculated values based on a probable lightning current. It is demonstrated that the highest overvoltages occur in circuits grounded in the main control panel. The obtained results help assess the risk of insulation breakdown due to direct lightning strikes and justify the implementation of additional protective measures. The developed approach can be further applied to improve methods for evaluating and ensuring electromagnetic compatibility of energy infrastructure facilities, particularly in the context of digitalization and SmartGrid deployment.
- Open Access
- 2 July 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 4,p. 80-85
Application of the multilayer soil equivalence method in determining the normalized parameters of the grounding system
Introduction. Normalized parameters of the grounding system, such as touch voltage and resistance, are critically important for ensuring electrical safety and reliability of power plants and substations. The complexity of the multi-layered soil structure makes it difficult to determine mentioned parameters. This is due to the fact that real soils on the territory of energy facilities of Ukraine have three or more layers, and the specified parameters are determined by software with two-layer calculation models. Therefore, the need to provide multilayer geoelectric structures into equivalence two-layer models for practical application is an urgent task. Goal. Determination of the application limits of the multilayer soils equivalence method based on the calculating results analysis of the grounding system normalized parameters. Methodology. The study considered a three-layer model for four soil types (A, H, Q, K) common in Ukraine. The calculations were performed using the LiGro software package, which is based on the method of integro-differential equations, applied to the analytical solution of the problem of the electric field potential of a point current source in a three-layer conducting half-space. As a criterion for the possibility of applying the equivalence method, a relative error value of 10 % was chosen when determining the normalized parameters of a grounding system of the given topology and soil type. When determining the error, the calculation results in the original three-layer soil structure for the given topology of the grounding system were taken as the true value. The results show that the effectiveness of equivalent technique significantly depends on the type of soil and the area of the grounding system. In particular, for soil type A, replacing the upper and middle layers with the equivalent first layer (the lower layer with the second) provides a smaller error in the calculations of the grounding resistance than representing the upper layer as the first, and the middle and lower layers as the second equivalent layer. At the same time, there is a tendency for the error to decrease with increasing area of the object: from 225 m2 to 14400 m2, for the first case, the error decreased from –14.6 % to –2.6 %, and for the second case, it changed from –9.3 % to 14.6 %, respectively. Originality. For the first time, the results of the methodical error evaluation of the equivalence techniques of multilayered soils of different types when calculating the normalized parameters of grounding system are presented. Practical value. Determination of the conditions and limits of the use of the equivalence method when calculating the normalized parameters of grounding system by software complexes can be used in the design of new or reconstruction of existing energy facilities of Ukraine. References 20, tables 5, figures 4.
- 2 July 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 4,p. 80-85
Open AccessApplication of the multilayer soil equivalence method in determining the normalized parameters of the grounding system
Introduction. Normalized parameters of the grounding system, such as touch voltage and resistance, are critically important for ensuring electrical safety and reliability of power plants and substations. The complexity of the multi-layered soil structure makes it difficult to determine mentioned parameters. This is due to the fact that real soils on the territory of energy facilities of Ukraine have three or more layers, and the specified parameters are determined by software with two-layer calculation models. Therefore, the need to provide multilayer geoelectric structures into equivalence two-layer models for practical application is an urgent task. Goal. Determination of the application limits of the multilayer soils equivalence method based on the calculating results analysis of the grounding system normalized parameters. Methodology. The study considered a three-layer model for four soil types (A, H, Q, K) common in Ukraine. The calculations were performed using the LiGro software package, which is based on the method of integro-differential equations, applied to the analytical solution of the problem of the electric field potential of a point current source in a three-layer conducting half-space. As a criterion for the possibility of applying the equivalence method, a relative error value of 10 % was chosen when determining the normalized parameters of a grounding system of the given topology and soil type. When determining the error, the calculation results in the original three-layer soil structure for the given topology of the grounding system were taken as the true value. The results show that the effectiveness of equivalent technique significantly depends on the type of soil and the area of the grounding system. In particular, for soil type A, replacing the upper and middle layers with the equivalent first layer (the lower layer with the second) provides a smaller error in the calculations of the grounding resistance than representing the upper layer as the first, and the middle and lower layers as the second equivalent layer. At the same time, there is a tendency for the error to decrease with increasing area of the object: from 225 m2 to 14400 m2, for the first case, the error decreased from –14.6 % to –2.6 %, and for the second case, it changed from –9.3 % to 14.6 %, respectively. Originality. For the first time, the results of the methodical error evaluation of the equivalence techniques of multilayered soils of different types when calculating the normalized parameters of grounding system are presented. Practical value. Determination of the conditions and limits of the use of the equivalence method when calculating the normalized parameters of grounding system by software complexes can be used in the design of new or reconstruction of existing energy facilities of Ukraine. References 20, tables 5, figures 4.
- Open Access
- 29 December 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 4(22),p. 62-68
PROCESSING OF MEASUREMENT RESULTS DURING TESTING THE OBJECT UNDER THE INFLUENCE OF A DIRECT LIGHTNING STRIKE
The current state of the problem of evaluating oscillograms during tests for the action of pulsed currents and voltages are analyzed, and the lack of interpretation tools that would meet the requirements of specialized standards for electromagnetic compatibility testing was shown. The program algorithm has been developed for interpreting the results of testing technical objects for resistance to a direct lightning strike in terms of processing oscillograms of various current components. The use of the trapezoidal method for numerical integration enabled the implementation of the algorithm as software for oscillogram interpretation in the Embarcadero RAD Studio XE8 programming environment. Standardized methods for determining pulse front, rise time, and pulse duration were taken into account during the implementation. In addition, the program allows you to determine the charge value and the integral of the current action in accordance with normalized values. Manual adjustment of the analysis interval was added, allowing the filtering of other current components and "noise" effects. The developed software found practical application in the verification testing of artificial lightning current generator complexes. The correctness of the program operation was confirmed by an empirical method. To obtain oscillograms, a measuring shunt with a range of up to 300 kA, lightning component pulse current generators and a simulated test object were used. The analysis was performed for all four components of artificial lightning, including the shortened constant component C*. Comparison of the interpretation results with "manual" analysis proved the high accuracy of the calculation (deviation up to 3%) with significantly less (5-10 times) time costs. Its extensive capabilities make the tool suitable for high-voltage testing and research in power engineering and related fields.
- 29 December 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 4(22),p. 62-68
Open AccessPROCESSING OF MEASUREMENT RESULTS DURING TESTING THE OBJECT UNDER THE INFLUENCE OF A DIRECT LIGHTNING STRIKE
The current state of the problem of evaluating oscillograms during tests for the action of pulsed currents and voltages are analyzed, and the lack of interpretation tools that would meet the requirements of specialized standards for electromagnetic compatibility testing was shown. The program algorithm has been developed for interpreting the results of testing technical objects for resistance to a direct lightning strike in terms of processing oscillograms of various current components. The use of the trapezoidal method for numerical integration enabled the implementation of the algorithm as software for oscillogram interpretation in the Embarcadero RAD Studio XE8 programming environment. Standardized methods for determining pulse front, rise time, and pulse duration were taken into account during the implementation. In addition, the program allows you to determine the charge value and the integral of the current action in accordance with normalized values. Manual adjustment of the analysis interval was added, allowing the filtering of other current components and "noise" effects. The developed software found practical application in the verification testing of artificial lightning current generator complexes. The correctness of the program operation was confirmed by an empirical method. To obtain oscillograms, a measuring shunt with a range of up to 300 kA, lightning component pulse current generators and a simulated test object were used. The analysis was performed for all four components of artificial lightning, including the shortened constant component C*. Comparison of the interpretation results with "manual" analysis proved the high accuracy of the calculation (deviation up to 3%) with significantly less (5-10 times) time costs. Its extensive capabilities make the tool suitable for high-voltage testing and research in power engineering and related fields.
- Open Access
- 24 December 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 4(18),p. 90-97
DEVELOPMENT OF THE CALCULATION PROCEDURE ALGORITHM FOR THE CALCULATION OF LIGHTNING RODS PROTECTION ZONES ACCORDING TO THE INTERNATIONAL STANDARD IEC 62305
Продовжено серію публікацій щодо проблеми захисту від проявів блискавки в електричних станціях та підстанціях, особливо в умовах зниження стабільності функціонування енергосистеми України. Додатково актуальність роботи аргументовано збільшенням грозової активності на планеті в цілому та даними національної енергокомпанії в Україні, що призводить до аварійних вимкнень на лініях електропередачі. Розроблено систему алгоритмів для обчислювальної процедури при розрахунку зон захисту системи, яка складається з багаточисельних стрижньових і тросових блискавковідводів та захисних сіток, за методом сфери, що котиться. Зазначено, що більшість стратегічних енергооб'єктів в Україні мають системи блискавкозахисту, побудовані згідно застарілих стандартів, тому необхідна їх перевірка та модернізація з урахуванням діючих нормативних документів. Розроблено узагальнений алгоритм побудови зони захисту з використаннням методу Делоне та отриманих раніше математичних виразів, який в свою чергу складається з підалгоритмів: побудови полігональної сітки по точкам координат блискавковідводів, знаходження зон торкання сфери вершин полігональної сітки, побудови сітки вузлів точок аналізу, знаходження координати висоти для кожної точки аналізу, побудова поверхні захисту по координатам сітки вузлів точок аналізу. Виконано програмну реалізацію та показано приклад застосування алгоритмів при розрахунку захищеності діючої підстанції класом напруги 150 кВ. Наведено загальні особливості програмної реалізації в програмному комплексі LiGro. Розроблений програмний продукт знайшов своє застосування при модернізацію існуючих систем блискавкозахисту діючих енергетичних об’єктів України класом напруги 35-750 кВ.
- 24 December 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 4(18),p. 90-97
Open AccessDEVELOPMENT OF THE CALCULATION PROCEDURE ALGORITHM FOR THE CALCULATION OF LIGHTNING RODS PROTECTION ZONES ACCORDING TO THE INTERNATIONAL STANDARD IEC 62305
Продовжено серію публікацій щодо проблеми захисту від проявів блискавки в електричних станціях та підстанціях, особливо в умовах зниження стабільності функціонування енергосистеми України. Додатково актуальність роботи аргументовано збільшенням грозової активності на планеті в цілому та даними національної енергокомпанії в Україні, що призводить до аварійних вимкнень на лініях електропередачі. Розроблено систему алгоритмів для обчислювальної процедури при розрахунку зон захисту системи, яка складається з багаточисельних стрижньових і тросових блискавковідводів та захисних сіток, за методом сфери, що котиться. Зазначено, що більшість стратегічних енергооб'єктів в Україні мають системи блискавкозахисту, побудовані згідно застарілих стандартів, тому необхідна їх перевірка та модернізація з урахуванням діючих нормативних документів. Розроблено узагальнений алгоритм побудови зони захисту з використаннням методу Делоне та отриманих раніше математичних виразів, який в свою чергу складається з підалгоритмів: побудови полігональної сітки по точкам координат блискавковідводів, знаходження зон торкання сфери вершин полігональної сітки, побудови сітки вузлів точок аналізу, знаходження координати висоти для кожної точки аналізу, побудова поверхні захисту по координатам сітки вузлів точок аналізу. Виконано програмну реалізацію та показано приклад застосування алгоритмів при розрахунку захищеності діючої підстанції класом напруги 150 кВ. Наведено загальні особливості програмної реалізації в програмному комплексі LiGro. Розроблений програмний продукт знайшов своє застосування при модернізацію існуючих систем блискавкозахисту діючих енергетичних об’єктів України класом напруги 35-750 кВ.
- Open Access
- 28 August 2023
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2023 (5) , 64-73
DETERMINATION OF THE RESISTANCE OF GROUNDING DEVICES OF SUBSTATIONS 330(220) kV
In the electric power industry of Ukraine, the main system-forming objects are power transmission lines and substations with 330(220) kV switchgear. The most powerful sources of danger at substations are short circuits on the busbars, a direct lightning strike or the operation of overvoltage limiters and arresters.The purpose of the article is to develop a method for determining the resistance of the grounding system of substations with open switchgear 330(220) kV, aimed at increasing accuracy, taking into account the most influential independent factors. The provisions of the theory of experiment planning, the theory of electric circuits, mathematical modeling in the package Grounding 1.0, LiGro and Microsoft Excel were used to conduct the research. In the paper, a comparative analysis of the known formulas for determining the resistance of the grounding system is carried out: the formula of the GOST 12.1.30-81 standard, Ohlendorf-Laurant, Laurent and Neumann, Schwartz, Sverak formulas, as well as the formula of the international standard IEEE Std 80-2013. The results of multifactorial experiments to determine the dependence of the resistance of the grounding system on its area, the size of the grid cell, the perimeter of the cross-section of the grounding, the equivalent specific resistance of the soil, the short-circuit current and the depth of the grid location are given. A graphical comparison of the results of determining the resistance according to the considered formulas was carried out. In the paper, the method of determining the parameters of grounding system of 330(220) kV substations was further developed, aimed at ensuring standardized values of the resistance of the grounding system and the ground potential rise using formulas obtained from the results of multifactorial experiments. The results obtained in the work will make it possible to reduce the probability of damage to the insulation of 6-10 kV cables, as well as cables of secondary circuits from low-frequency and high-frequency (pulse) voltages when large currents flow into the grounding system in the mode of a single-phase short-circuit to the ground in electrical grid with a grounded neutral. References 9, tables 2, figures 6. В електроенергетиці України основними системоутворюючими об'єктами є лінії електропередачі та підстанції з розподільними пристроями 330(220) кВ. Найбільш потужними джерелами небезпеки на підстанціях є короткі замикання на шинах, прямий удар блискавки або спрацювання обмежувачів перенапруги і розрядників. Метою статті є вдосконалення способу визначення опору заземлювального пристрою підстанцій з відкритими розподільними пристроями 330(220) кВ, спрямованого на підвищення точності з урахуванням найбільш впливових незалежних факторів. Для проведення досліджень використовувалися положення теорії планування експериментів, теорія електричних кіл, математичне моделювання в пакеті Grounding 1.0, LiGro та Microsoft Excel. У роботі наведено результати багатофакторних експериментів задля визначення залежності опору заземлювального пристрою з рівномірною сіткою від його площі, розміру чарунки сітки, периметра поперечного перерізу заземлювачів, еквівалентного питомого опору ґрунту, струму короткого замикання та глибини залягання сітки. У роботі отримала подальший розвиток методика визначення параметрів заземлювальних пристроїв підстанцій 330(220) кВ, спрямована на забезпечення нормованих значень опору заземлювального пристрою та напруги на заземлювальному пристрої з використанням формул, отриманих за результатами багатофакторних експериментів. Отримані в роботі результати надають змогу забезпечити зменшення ймовірності пошкодження ізоляції кабелів 6-10 кВ, а також кабелів вторинних кіл від низькочастотних та високочастотних (імпульсних) напруг у разі стікання в заземлювальний пристрій великих струмів в режимі однофазного замикання на землю в електричних мережах з заземленою нейтраллю. Бібл. 9, табл. 2, рис. 6.
- 28 August 2023
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Tekhnichna Elektrodynamika
- Vol. 2023 (5) , 64-73
Open AccessDETERMINATION OF THE RESISTANCE OF GROUNDING DEVICES OF SUBSTATIONS 330(220) kV
In the electric power industry of Ukraine, the main system-forming objects are power transmission lines and substations with 330(220) kV switchgear. The most powerful sources of danger at substations are short circuits on the busbars, a direct lightning strike or the operation of overvoltage limiters and arresters.The purpose of the article is to develop a method for determining the resistance of the grounding system of substations with open switchgear 330(220) kV, aimed at increasing accuracy, taking into account the most influential independent factors. The provisions of the theory of experiment planning, the theory of electric circuits, mathematical modeling in the package Grounding 1.0, LiGro and Microsoft Excel were used to conduct the research. In the paper, a comparative analysis of the known formulas for determining the resistance of the grounding system is carried out: the formula of the GOST 12.1.30-81 standard, Ohlendorf-Laurant, Laurent and Neumann, Schwartz, Sverak formulas, as well as the formula of the international standard IEEE Std 80-2013. The results of multifactorial experiments to determine the dependence of the resistance of the grounding system on its area, the size of the grid cell, the perimeter of the cross-section of the grounding, the equivalent specific resistance of the soil, the short-circuit current and the depth of the grid location are given. A graphical comparison of the results of determining the resistance according to the considered formulas was carried out. In the paper, the method of determining the parameters of grounding system of 330(220) kV substations was further developed, aimed at ensuring standardized values of the resistance of the grounding system and the ground potential rise using formulas obtained from the results of multifactorial experiments. The results obtained in the work will make it possible to reduce the probability of damage to the insulation of 6-10 kV cables, as well as cables of secondary circuits from low-frequency and high-frequency (pulse) voltages when large currents flow into the grounding system in the mode of a single-phase short-circuit to the ground in electrical grid with a grounded neutral. References 9, tables 2, figures 6. В електроенергетиці України основними системоутворюючими об'єктами є лінії електропередачі та підстанції з розподільними пристроями 330(220) кВ. Найбільш потужними джерелами небезпеки на підстанціях є короткі замикання на шинах, прямий удар блискавки або спрацювання обмежувачів перенапруги і розрядників. Метою статті є вдосконалення способу визначення опору заземлювального пристрою підстанцій з відкритими розподільними пристроями 330(220) кВ, спрямованого на підвищення точності з урахуванням найбільш впливових незалежних факторів. Для проведення досліджень використовувалися положення теорії планування експериментів, теорія електричних кіл, математичне моделювання в пакеті Grounding 1.0, LiGro та Microsoft Excel. У роботі наведено результати багатофакторних експериментів задля визначення залежності опору заземлювального пристрою з рівномірною сіткою від його площі, розміру чарунки сітки, периметра поперечного перерізу заземлювачів, еквівалентного питомого опору ґрунту, струму короткого замикання та глибини залягання сітки. У роботі отримала подальший розвиток методика визначення параметрів заземлювальних пристроїв підстанцій 330(220) кВ, спрямована на забезпечення нормованих значень опору заземлювального пристрою та напруги на заземлювальному пристрої з використанням формул, отриманих за результатами багатофакторних експериментів. Отримані в роботі результати надають змогу забезпечити зменшення ймовірності пошкодження ізоляції кабелів 6-10 кВ, а також кабелів вторинних кіл від низькочастотних та високочастотних (імпульсних) напруг у разі стікання в заземлювальний пристрій великих струмів в режимі однофазного замикання на землю в електричних мережах з заземленою нейтраллю. Бібл. 9, табл. 2, рис. 6.
- Open Access
- 21 August 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 5,p. 63-68
Determination of the electric field strength of high-voltage substations
The electric field strength is one of the main factors influencing sensitive microprocessor equipment and personnel on power stations and substations, power lines. Determining its level is an important applied task for ensuring the safe operation of electrical installations. The aim is to develop calculation relationships for determining the electric field strength created by the busbar of high-voltage substations in the working areas of personnel. The solution of the problem was based on the use of the method of equivalent charges to determine the strength of the electric field created by the complex busbar of high-voltage substations. Methodology. The development was based on solving the problem of the potential of the electric field of a point charge located in a dielectric half-space for a cylindrical coordinate system. By representing the electrode in the form of a set of point charges and subsequent integration, an expression for calculating the potential is obtained, created by a busbar of arbitrary orientation of finite length in an analytical form. Using the principle of superposition of fields and the definition of the derivative, expressions were obtained for calculating the vertical component of the electric field strength at given heights. Results. Based on the obtained expressions, using Visual Basic, the simulation of the distribution of the electric field strength under a three-phase power line with a voltage of 150 kV was performed. Comparison with the known calculation results obtained on the basis of analytical expressions for infinitely long conductors showed that the obtained expressions have an error of no more than 7%. The scientific novelty lies in the fact that for the first time expressions were obtained for determining the electric field strength created by a system of electrodes of finite length, based on the analytical method for solving differential equations. Practical significance. The proposed technique is implemented as a test module of the LiGro specialized software package, which allows modeling complex busbar systems typical for power stations and substations and power lines. A test calculation was carried out for an operating substation of regional electric networks with a voltage class of 110 kV. By comparing the duration of the calculation of switchgears with a diagonal of about 500 m, it was found that the calculation time in the LiGro complex based on the analytical method is several tens of times less than the calculation based on the finite element method. In addition, a more powerful computer was used for the end element simulation.
- 21 August 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 5,p. 63-68
Open AccessDetermination of the electric field strength of high-voltage substations
The electric field strength is one of the main factors influencing sensitive microprocessor equipment and personnel on power stations and substations, power lines. Determining its level is an important applied task for ensuring the safe operation of electrical installations. The aim is to develop calculation relationships for determining the electric field strength created by the busbar of high-voltage substations in the working areas of personnel. The solution of the problem was based on the use of the method of equivalent charges to determine the strength of the electric field created by the complex busbar of high-voltage substations. Methodology. The development was based on solving the problem of the potential of the electric field of a point charge located in a dielectric half-space for a cylindrical coordinate system. By representing the electrode in the form of a set of point charges and subsequent integration, an expression for calculating the potential is obtained, created by a busbar of arbitrary orientation of finite length in an analytical form. Using the principle of superposition of fields and the definition of the derivative, expressions were obtained for calculating the vertical component of the electric field strength at given heights. Results. Based on the obtained expressions, using Visual Basic, the simulation of the distribution of the electric field strength under a three-phase power line with a voltage of 150 kV was performed. Comparison with the known calculation results obtained on the basis of analytical expressions for infinitely long conductors showed that the obtained expressions have an error of no more than 7%. The scientific novelty lies in the fact that for the first time expressions were obtained for determining the electric field strength created by a system of electrodes of finite length, based on the analytical method for solving differential equations. Practical significance. The proposed technique is implemented as a test module of the LiGro specialized software package, which allows modeling complex busbar systems typical for power stations and substations and power lines. A test calculation was carried out for an operating substation of regional electric networks with a voltage class of 110 kV. By comparing the duration of the calculation of switchgears with a diagonal of about 500 m, it was found that the calculation time in the LiGro complex based on the analytical method is several tens of times less than the calculation based on the finite element method. In addition, a more powerful computer was used for the end element simulation.
- Open Access
- 8 June 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 2(16),p. 18-25
SOFTWARE FOR INTERPRETING THE RESULTS OF VERTICAL ELECTRICAL SOUNDING IN THE FORM OF A THREE-LAYER GEOELECTRIC STRUCTURE
By monitoring the state of the grounding system, electrical engineering personnel must independently solve the problem of interpreting the results of vertical electrical sounding (VES) of the soil using their own knowledge and practical experience. During the interpretation, outdated palettes or expensive software complexes are used, which allow analyzing only two-layer soils. This leads to a large number of errors and inaccuracies in the assessment of the state of the grounding system and worsens their operation. In this regard, a program was developed for the interpretation of the results of the VES in the form of a three-layer geoelectrical structure. The program is implemented in the Delphi programming language and contains two parts: computational and graphic. The computational part of the program uses point source current, Hooke-Jives, equivalence and reliability theory methods to optimize the determination of geoelectric model parameters. The graphical part allows the user to visualize the obtained results and perform their analysis. To confirm the reliability of the developed program, a comparison of the results of the experimental measurement of the resistance of the grounding arrangmants with the results of the calculation using the program was made for 65 substations with a voltage class of 35 kV of one of the regional energy companies of Ukraine. The obtained results showed that the program gives reliable results and can improve the quality of monitoring the condition of grounding systems, and accordingly increase the reliability and safety of operation of electrical stations and substations.
- 8 June 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 2(16),p. 18-25
Open AccessSOFTWARE FOR INTERPRETING THE RESULTS OF VERTICAL ELECTRICAL SOUNDING IN THE FORM OF A THREE-LAYER GEOELECTRIC STRUCTURE
By monitoring the state of the grounding system, electrical engineering personnel must independently solve the problem of interpreting the results of vertical electrical sounding (VES) of the soil using their own knowledge and practical experience. During the interpretation, outdated palettes or expensive software complexes are used, which allow analyzing only two-layer soils. This leads to a large number of errors and inaccuracies in the assessment of the state of the grounding system and worsens their operation. In this regard, a program was developed for the interpretation of the results of the VES in the form of a three-layer geoelectrical structure. The program is implemented in the Delphi programming language and contains two parts: computational and graphic. The computational part of the program uses point source current, Hooke-Jives, equivalence and reliability theory methods to optimize the determination of geoelectric model parameters. The graphical part allows the user to visualize the obtained results and perform their analysis. To confirm the reliability of the developed program, a comparison of the results of the experimental measurement of the resistance of the grounding arrangmants with the results of the calculation using the program was made for 65 substations with a voltage class of 35 kV of one of the regional energy companies of Ukraine. The obtained results showed that the program gives reliable results and can improve the quality of monitoring the condition of grounding systems, and accordingly increase the reliability and safety of operation of electrical stations and substations.
- Open Access
- 4 January 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 1,p. 77-82
Determination of the scope of the experimental-calculation method for measuring the touch voltage
The work is devoted to the improvement of methods for determining the normalized parameters of the grounding system (GS) of operating power stations and substations. The aim of the work is determination of the scope of the experimental-calculated method for measuring the touch voltage, depending on short-circuit (SC) current value for the given dimensions of the GS and the type of soil. Methodology. The study analyzed the non-linear effect of the SC current value on the touch voltage, taking into account such factors as the GS size and the soil type. The calculation used statistical data on the GS size and the characteristics of the soil obtained by monitoring the GS state of 585 operating electrical substations with a voltage class of 110-750 kV using the induction method and the method of vertical soil sounding, respectively. For the calculation, a mathematical model of a non-equipotential GS located in a three-layer semiconductor space with plane-parallel boundaries was used, this model was developed using the method of integro-differential equations. Results. To determine the scope of the method, in this work it is proposed to use the linearity criterion, which is determined due to the ratio of the constant of reduced touch voltage to the current value. The example shows the method for determining the threshold minimum and maximum values of the measuring current of the soil, in the range between which the measurements by experimental-calculated methods are impossible. A table of threshold current values has been formed and recommendations have been developed on the possibility of using experimental-measuring methods for determining the touch voltage depending on the GS size and soil characteristics.
- 4 January 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 1,p. 77-82
Open AccessDetermination of the scope of the experimental-calculation method for measuring the touch voltage
The work is devoted to the improvement of methods for determining the normalized parameters of the grounding system (GS) of operating power stations and substations. The aim of the work is determination of the scope of the experimental-calculated method for measuring the touch voltage, depending on short-circuit (SC) current value for the given dimensions of the GS and the type of soil. Methodology. The study analyzed the non-linear effect of the SC current value on the touch voltage, taking into account such factors as the GS size and the soil type. The calculation used statistical data on the GS size and the characteristics of the soil obtained by monitoring the GS state of 585 operating electrical substations with a voltage class of 110-750 kV using the induction method and the method of vertical soil sounding, respectively. For the calculation, a mathematical model of a non-equipotential GS located in a three-layer semiconductor space with plane-parallel boundaries was used, this model was developed using the method of integro-differential equations. Results. To determine the scope of the method, in this work it is proposed to use the linearity criterion, which is determined due to the ratio of the constant of reduced touch voltage to the current value. The example shows the method for determining the threshold minimum and maximum values of the measuring current of the soil, in the range between which the measurements by experimental-calculated methods are impossible. A table of threshold current values has been formed and recommendations have been developed on the possibility of using experimental-measuring methods for determining the touch voltage depending on the GS size and soil characteristics.
- Open Access
- 28 December 2022
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 4(14),p. 75-81
SELECTION OF THE TECHNIQUE OF ARRANGEMENT OF EQUIPMENT SERVICE AREA TO PROVIDE THE PERMISSIBLE TOUCH VOLTAGE
Ensuring the permissible value of the touch voltage in operating electrical installations is a necessary condition for the electrical safety of personnel and third parties. In the study, based on literature data, it is analyzed in which cases it is impossible to achieve the permissible values of the touch voltage only with the help of the design of the grounding system. It is shown that ensuring the permissible value of the touch voltage is performed by arranging in a special way both the place of operational maintenance of the equipment and the territory of the opendoor switchgear. It is study the selection a technique of arrangement of the service place to ensure the permissible value of the touch voltage on the equipment of the opendoor switchgear during a single-phase short circuit to the ground. When performing the work, statistical methods of analysis, the ammeter-voltmeter method for experimental determination of the resistance of the base according to the method of Research&Design institute "Molniya" NTU "KhPI" were used. For the first time, on the basis of statistical data, the necessity of arrangement of equipment service area to ensure an acceptable value of touch voltage at operating substations of class 110 (150) kV and 330 (220) kV was analyzed. The spread of base resistance (ground resistance of human foot) values was determined experimentally. The most common ways of arrangement of equipment service area were analyzed: technological (natural), namely: a reinforced concrete pool with a layer of crushed stone, a cable channel or tray, asphalt paths and specially created (artificial) ones, namely: a metal structure , a layer of crushed stone, reinforced concrete slabs, concrete slabs without scaffolding, paving slabs, concrete slabs (paving slabs) with gravel admixtures, polymer sand slabs. The base resistance was measured for the listed techniques at operating substations. The advantages and disadvantages of various arrangement of equipment service area are determined, and recommendations for their use are provided.
- 28 December 2022
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University «KhPI» Series: New solutions in modern technologies
- No. 4(14),p. 75-81
Open AccessSELECTION OF THE TECHNIQUE OF ARRANGEMENT OF EQUIPMENT SERVICE AREA TO PROVIDE THE PERMISSIBLE TOUCH VOLTAGE
Ensuring the permissible value of the touch voltage in operating electrical installations is a necessary condition for the electrical safety of personnel and third parties. In the study, based on literature data, it is analyzed in which cases it is impossible to achieve the permissible values of the touch voltage only with the help of the design of the grounding system. It is shown that ensuring the permissible value of the touch voltage is performed by arranging in a special way both the place of operational maintenance of the equipment and the territory of the opendoor switchgear. It is study the selection a technique of arrangement of the service place to ensure the permissible value of the touch voltage on the equipment of the opendoor switchgear during a single-phase short circuit to the ground. When performing the work, statistical methods of analysis, the ammeter-voltmeter method for experimental determination of the resistance of the base according to the method of Research&Design institute "Molniya" NTU "KhPI" were used. For the first time, on the basis of statistical data, the necessity of arrangement of equipment service area to ensure an acceptable value of touch voltage at operating substations of class 110 (150) kV and 330 (220) kV was analyzed. The spread of base resistance (ground resistance of human foot) values was determined experimentally. The most common ways of arrangement of equipment service area were analyzed: technological (natural), namely: a reinforced concrete pool with a layer of crushed stone, a cable channel or tray, asphalt paths and specially created (artificial) ones, namely: a metal structure , a layer of crushed stone, reinforced concrete slabs, concrete slabs without scaffolding, paving slabs, concrete slabs (paving slabs) with gravel admixtures, polymer sand slabs. The base resistance was measured for the listed techniques at operating substations. The advantages and disadvantages of various arrangement of equipment service area are determined, and recommendations for their use are provided.