Ayça Tulga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ayça Tulga has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ahmet Serkan Küçükekenci
Ordu Üniversitesi
1 shared publication - Doğu Ömür Dede
Ordu Üniversitesi
1 shared publication Duygu Saraç
1 shared publicationElif Bahar Çakıcı
Department of Endodontics, Faculty of Dentistry, Ordu University, Turkey
1 shared publicationElçin Sağırkaya
Department of Prosthodontics, School of Dentistry, Ordu University, Turkey
1 shared publication- Ersan Çelik
Ordu University
1 shared publication
Latest Publications
- Open Access
- 1 January 2021
- Published by Termedia Sp. z.o.o. in Journal of Stomatology
- Vol. 74 (2) , 89-94
Evaluation of bond strength of resin nano-ceramic as post material
Introduction Different usage areas of newly developed restorative materials have increased.. Objectives: The purpose of this study was to investigate usability of a newly produced resin nano-ceramic (RNC) as a post material, and how to increase bond strength of different post systems to root...
- 1 January 2021
- Published by Termedia Sp. z.o.o. in Journal of Stomatology
- Vol. 74 (2) , 89-94
Open AccessEvaluation of bond strength of resin nano-ceramic as post material
Introduction Different usage areas of newly developed restorative materials have increased.. Objectives: The purpose of this study was to investigate usability of a newly produced resin nano-ceramic (RNC) as a post material, and how to increase bond strength of different post systems to root...
- 22 March 2019
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 33 (10) , 1102-1111
The effects of universal adhesive and innovative fabrication techniques of metal-ceramic restorations on repair strength of porcelain fracture with metal exposure
This study was to evaluate the effects of universal adhesive and innovative fabrication techniques of Cobalt-Chromium (Co-Cr) alloys on shear bond strength (SBS) between the repair material. One hundred forty-four Co-Cr alloys specimens were fabricated by casting (C), milling (M), direct process powder-bed method (CL), and direct metal laser sintering (DMLS) (EL). Each group was then divided randomly into three groups, according to the chemical agent used: alloy primer (Z), universal adhesive (A), or both (AZ). The composite resin cylinders were built on metal specimens. SBSs were determined after water storage and thermocycling, and data were statistically analyzed. The method used for the fabrication of Co-Cr alloy had a significant effect on bond strength (p = 0.016). AZ (12.077 ± 0.575 MPa) groups showed highest SBS values. Co-Cr alloys fabricated with DMLS method have a superior repair capacity. The universal adhesive increased the repair strength when applied with an alloy primer.
- 22 March 2019
- Published by Taylor & Francis in Journal of Adhesion Science and Technology
- Vol. 33 (10) , 1102-1111
The effects of universal adhesive and innovative fabrication techniques of metal-ceramic restorations on repair strength of porcelain fracture with metal exposure
This study was to evaluate the effects of universal adhesive and innovative fabrication techniques of Cobalt-Chromium (Co-Cr) alloys on shear bond strength (SBS) between the repair material. One hundred forty-four Co-Cr alloys specimens were fabricated by casting (C), milling (M), direct process powder-bed method (CL), and direct metal laser sintering (DMLS) (EL). Each group was then divided randomly into three groups, according to the chemical agent used: alloy primer (Z), universal adhesive (A), or both (AZ). The composite resin cylinders were built on metal specimens. SBSs were determined after water storage and thermocycling, and data were statistically analyzed. The method used for the fabrication of Co-Cr alloy had a significant effect on bond strength (p = 0.016). AZ (12.077 ± 0.575 MPa) groups showed highest SBS values. Co-Cr alloys fabricated with DMLS method have a superior repair capacity. The universal adhesive increased the repair strength when applied with an alloy primer.
- 17 April 2018
- Published by SDU Journal of Health Sciences in SDÜ SAĞLIK BİLİMLERİ DERGİSİ
- Vol. 9 (1) , 34-39
Shear bond strength of veneer composite to cobalt-chromium alloys fabricated differently
Objective: The purpose of this study was to assess and contrast the shear bond strength of a veneer composite resin bonded to cobalt-chromium (CoCr) dental alloys produced by different techniques. Material-Method: Ninety cylindrical specimens (10mm in diameter, 8mm in height) made of CoCr dental alloys were prepared by casting (C), milling (M), LaserCUSING with and without annealing (CL+, CL), and direct metal laser sintering (DMLS) with and without annealing (EL+, EL). Veneer composite cylinders (5mm in diameter, 3mm in height) were built on metal specimens using a silicone jig. After storage in water for 24 hours, the specimens were assessed for bond strength with a shear force test at a crosshead speed of 0.5 mm/min. The shear bond strengths (SBSs) were statistically analyzed using the Kolmogorow-Smirnow test and Tukey-HSD multiple comparison test (α=.05). Results: When the SBS values of the groups were compared, significant differences were found among the groups (P<.05). While statistically significant differences were found between the CL+ group (9.36 ∓ 2.62) and the M group (13.34 ∓ 2.53) (P<.05), there were no significant differences among the others (P>.05). The debonded surfaces of the specimens exhibited mostly mixed failure types. Conclusions: The CoCr alloy fabrication technique has an effect on the SBSs between the veneer composite resin and the metal used. LaserCUSING casting, a new technology, seems to have the lowest metal-resin bond strength among all the techniques tested.
- 17 April 2018
- Published by SDU Journal of Health Sciences in SDÜ SAĞLIK BİLİMLERİ DERGİSİ
- Vol. 9 (1) , 34-39
Shear bond strength of veneer composite to cobalt-chromium alloys fabricated differently
Objective: The purpose of this study was to assess and contrast the shear bond strength of a veneer composite resin bonded to cobalt-chromium (CoCr) dental alloys produced by different techniques. Material-Method: Ninety cylindrical specimens (10mm in diameter, 8mm in height) made of CoCr dental alloys were prepared by casting (C), milling (M), LaserCUSING with and without annealing (CL+, CL), and direct metal laser sintering (DMLS) with and without annealing (EL+, EL). Veneer composite cylinders (5mm in diameter, 3mm in height) were built on metal specimens using a silicone jig. After storage in water for 24 hours, the specimens were assessed for bond strength with a shear force test at a crosshead speed of 0.5 mm/min. The shear bond strengths (SBSs) were statistically analyzed using the Kolmogorow-Smirnow test and Tukey-HSD multiple comparison test (α=.05). Results: When the SBS values of the groups were compared, significant differences were found among the groups (P<.05). While statistically significant differences were found between the CL+ group (9.36 ∓ 2.62) and the M group (13.34 ∓ 2.53) (P<.05), there were no significant differences among the others (P>.05). The debonded surfaces of the specimens exhibited mostly mixed failure types. Conclusions: The CoCr alloy fabrication technique has an effect on the SBSs between the veneer composite resin and the metal used. LaserCUSING casting, a new technology, seems to have the lowest metal-resin bond strength among all the techniques tested.
- 1 September 2017
- Published by Quintessence Publishing in International Journal of Periodontics & Restorative Dentistry
- Vol. 35 (5) , e66-e74
Effects of Dentin Surface Treatments on Hypersensitivity to Bond Strength of Restorations: An In Vitro Study
Ay?a Tulga, DDS, PhD/Duygu Sara?, DDS, PhD: This study evaluated the effects of desensitizing treatments on the shear bond strength (SBS) of adhesive resin cement (Rely X U100) applied to dentin. Human molars (n = 120) with exposed dentin were divided into 12 groups. In the experimental groups, dentin surfaces were treated with (1) an erbium:yttrium? aluminium?garnet (Er:YAG) laser, (2) a neodymium:yttrium?aluminium?garnet (Nd:YAG) laser, (3) glutaraldehyde (Gluma)?, (4) fluoride (Aqua Prep-F)?, and (5) oxalate (BisBlock)?containing desensitizing agents, (6) Gluma preceding the Er:YAG laser, (7) Aqua Prep-F preceding the Er:YAG laser, (8) BisBlock preceding the Er:YAG laser, (9) Gluma preceding the Nd:YAG laser, (10) Aqua Prep-F preceding the Nd:YAG laser, (11) and BisBlock preceding the Nd:YAG laser, in groups EL, NL, G, F, O, EL-G, EL-F, EL-O, NL-G , NL-F, and NL-O, respectively. Then, lithium disilicate ceramics were cemented to the treated surfaces. Subsequently, an SBS test was performed and the data were statistically analyzed (α = .001). The results suggested that the combined treatment of Gluma preceding Er:YAG laser increased the bond strength of ceramic to the dentin surface using a self-adhesive resin cement.
- 1 September 2017
- Published by Quintessence Publishing in International Journal of Periodontics & Restorative Dentistry
- Vol. 35 (5) , e66-e74
Effects of Dentin Surface Treatments on Hypersensitivity to Bond Strength of Restorations: An In Vitro Study
Ay?a Tulga, DDS, PhD/Duygu Sara?, DDS, PhD: This study evaluated the effects of desensitizing treatments on the shear bond strength (SBS) of adhesive resin cement (Rely X U100) applied to dentin. Human molars (n = 120) with exposed dentin were divided into 12 groups. In the experimental groups, dentin surfaces were treated with (1) an erbium:yttrium? aluminium?garnet (Er:YAG) laser, (2) a neodymium:yttrium?aluminium?garnet (Nd:YAG) laser, (3) glutaraldehyde (Gluma)?, (4) fluoride (Aqua Prep-F)?, and (5) oxalate (BisBlock)?containing desensitizing agents, (6) Gluma preceding the Er:YAG laser, (7) Aqua Prep-F preceding the Er:YAG laser, (8) BisBlock preceding the Er:YAG laser, (9) Gluma preceding the Nd:YAG laser, (10) Aqua Prep-F preceding the Nd:YAG laser, (11) and BisBlock preceding the Nd:YAG laser, in groups EL, NL, G, F, O, EL-G, EL-F, EL-O, NL-G , NL-F, and NL-O, respectively. Then, lithium disilicate ceramics were cemented to the treated surfaces. Subsequently, an SBS test was performed and the data were statistically analyzed (α = .001). The results suggested that the combined treatment of Gluma preceding Er:YAG laser increased the bond strength of ceramic to the dentin surface using a self-adhesive resin cement.
- Open Access
- 1 January 2017
- Published by The Korean Academy of Prosthodontics in The Journal of Advanced Prosthodontics
- Vol. 9 (6) , 439-446
Influence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement
Kömürcüoğlu MB, et al. J Adv Prosthodont. 2017 Dec;9(6):439-446. https://doi.org/10.4047/jap.2017.9.6.439
- 1 January 2017
- Published by The Korean Academy of Prosthodontics in The Journal of Advanced Prosthodontics
- Vol. 9 (6) , 439-446
Open AccessInfluence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement
Kömürcüoğlu MB, et al. J Adv Prosthodont. 2017 Dec;9(6):439-446. https://doi.org/10.4047/jap.2017.9.6.439