Ersan Çelik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ersan Çelik has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Caner Öztürk
Ankara Medipol University
4 shared publications - Sezgi Cinel Sahin
Department of Prosthodontics, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
4 shared publications - Doğu Ömür Dede
Ordu Üniversitesi
3 shared publications - Büşra Göktepe
Çanakkale Oral and Dental Health Center, Çanakkale, Türkiye
2 shared publications - Fatih Cakici
Ordu University
2 shared publications - A. Nehir Özden
Yakın Doğu Üniversitesi Diş Hekimliği Fakültesi Protetik Diş Tedavisi AD
1 shared publication
Latest Publications
- Open Access
- 12 January 2026
- Published by LookUs Bilisim A.S. in Medical Records
- No. 1
Effect of bleaching agents on microhardness of different resin matrix ceramics
Aim: The objective of this study is to assess the effect of different bleaching protocols and concentrations on the microhardness of CAD/CAM materials in vitro. Material and Methods: Five contemporary CAD/CAM blocks; resin nanoceramic, flexible nano-hybrid ceramic, hybrid ceramic, resin-infiltrated ceramic, reinforced composite were used. One hundred samples were prepared for every block and bleaching procedure (n=10) with a thickness of 1.5 mm. Finishing and polishing were applied in accordance with the manufacturers' recommendations. Opalescence PF bleaching gel with a 16% carbamide peroxide content was applied to the at-home bleaching group for 14 days for 6 hours a day, whereas Opalescence Boost bleaching gel with a hydrogen peroxide content of 40% was applied to the in-office bleaching group for 20 minutes 2 times per session on days 1 and 7. The microhardness of the samples was measured with a Vickers hardness device before and after processing. The data were statistically evaluated with the repeated-measures analysis of variance and the Bonferroni correction. Results: After bleaching, the highest microhardness values were in the resin-infiltrated ceramic (p
- 12 January 2026
- Published by LookUs Bilisim A.S. in Medical Records
- No. 1
Open AccessEffect of bleaching agents on microhardness of different resin matrix ceramics
Aim: The objective of this study is to assess the effect of different bleaching protocols and concentrations on the microhardness of CAD/CAM materials in vitro. Material and Methods: Five contemporary CAD/CAM blocks; resin nanoceramic, flexible nano-hybrid ceramic, hybrid ceramic, resin-infiltrated ceramic, reinforced composite were used. One hundred samples were prepared for every block and bleaching procedure (n=10) with a thickness of 1.5 mm. Finishing and polishing were applied in accordance with the manufacturers' recommendations. Opalescence PF bleaching gel with a 16% carbamide peroxide content was applied to the at-home bleaching group for 14 days for 6 hours a day, whereas Opalescence Boost bleaching gel with a hydrogen peroxide content of 40% was applied to the in-office bleaching group for 20 minutes 2 times per session on days 1 and 7. The microhardness of the samples was measured with a Vickers hardness device before and after processing. The data were statistically evaluated with the repeated-measures analysis of variance and the Bonferroni correction. Results: After bleaching, the highest microhardness values were in the resin-infiltrated ceramic (p
- 26 December 2025
- Published by Marmara University in Clinical and Experimental Health Sciences
- Vol. 15 (4) , 891-896
Color Stability of Bleached Resin Based Hybrid CAD/CAM Restorative Materials: An in vitro Study
Objective: The color stability of restorative materials is a major factor for the long-term success of a restoration. The aim of this study is to evaluate the color stability of bleached resin matrix ceramic block materials in coffee immersion. Methods: Five different A2 shaded CAD/CAM resin matrix ceramic block materials (Lava Ultimate-LU, Shofu Blok HC- SHC, GC Cerasmart- GCER, Vita Enamic-VE, Brilliant Crios-BE) were used in this study (n:10). The color stability of the samples after different bleaching procedures (Opalescence BOOST and Opalescence PF) and coffee immersion were calculated using ∆E00 formula. The L*, a*, b* values were measured by using a spectrophotometer and data were analyzed by using Repeated-Measures ANOVA and ΔE00 values were evaluated Two-way ANOVA test at the significance level of p0.05), but after coffee immersion L* values significantly decreased (p
- 26 December 2025
- Published by Marmara University in Clinical and Experimental Health Sciences
- Vol. 15 (4) , 891-896
Color Stability of Bleached Resin Based Hybrid CAD/CAM Restorative Materials: An in vitro Study
Objective: The color stability of restorative materials is a major factor for the long-term success of a restoration. The aim of this study is to evaluate the color stability of bleached resin matrix ceramic block materials in coffee immersion. Methods: Five different A2 shaded CAD/CAM resin matrix ceramic block materials (Lava Ultimate-LU, Shofu Blok HC- SHC, GC Cerasmart- GCER, Vita Enamic-VE, Brilliant Crios-BE) were used in this study (n:10). The color stability of the samples after different bleaching procedures (Opalescence BOOST and Opalescence PF) and coffee immersion were calculated using ∆E00 formula. The L*, a*, b* values were measured by using a spectrophotometer and data were analyzed by using Repeated-Measures ANOVA and ΔE00 values were evaluated Two-way ANOVA test at the significance level of p0.05), but after coffee immersion L* values significantly decreased (p
- Open Access
- 10 July 2025
- Published by AVES YAYINCILIK A.Ş. in Essentials of Dentistry
- Vol. 4 (1) , 1-7
Effect of Thickness of Resin Matrix Ceramics on Polymerization of Resin Cements
Background: This study aimed to assess how the thickness of resin matrix ceramics (RMC) impacted the microhardness of the underlying resin cement. Methods: Three types of RMC were analyzed: polymer infiltrated ceramic, resin nano ceramic, and nano ceramic. Every ceramic block had sections 0.5, 1, and 1.5 mm thick and 8 mm in diameter. Nine groups, each containing 10 RMC discs (n = 10), were produced by combining all the parameters. Central-holed stainless steel that was 6 mm in diameter and 0.5 mm deep was used for applying translucent light-cured luting resin. The resin cement underwent polymerization in direct contact with the RMC. Under a 50 g load and a 15-second indentation duration, Vickers measurements were taken from the underside of the resin cement specimens using 3 distinct indentation locations. The average of the 3 measurements for each specimen was utilized to determine the Vickers hardness value. The data were analyzed using two-way ANOVA and Tukey post hoc tests. Results: In the case of resin cements with underlying thicknesses of 0.5 mm and 1 mm, the groups GC Cerasmart and Vita Enamic demonstrated significantly higher average microhardness in comparison to the Lava Ultimate group (P < .05). Compared to the GC Cerasmart and Vita Enamic groups, the Lava Ultimate group’s mean microhardness of the resin cements for a thickness of 1.5 mm was significantly lower (P < .05). Conclusion: Resin matrix ceramics thickness and type had a significant effect on microhardness values in all kinds of RMC. Cite this article as: Göktepe B, Çelik E, Gönüldaş F. Effect of thickness of resin matrix ceramics on polymerization of resin cements. Essent Dent. 2025, 4, 0052, doi: 10.5152/EssentDent.2025.25052.
- 10 July 2025
- Published by AVES YAYINCILIK A.Ş. in Essentials of Dentistry
- Vol. 4 (1) , 1-7
Open AccessEffect of Thickness of Resin Matrix Ceramics on Polymerization of Resin Cements
Background: This study aimed to assess how the thickness of resin matrix ceramics (RMC) impacted the microhardness of the underlying resin cement. Methods: Three types of RMC were analyzed: polymer infiltrated ceramic, resin nano ceramic, and nano ceramic. Every ceramic block had sections 0.5, 1, and 1.5 mm thick and 8 mm in diameter. Nine groups, each containing 10 RMC discs (n = 10), were produced by combining all the parameters. Central-holed stainless steel that was 6 mm in diameter and 0.5 mm deep was used for applying translucent light-cured luting resin. The resin cement underwent polymerization in direct contact with the RMC. Under a 50 g load and a 15-second indentation duration, Vickers measurements were taken from the underside of the resin cement specimens using 3 distinct indentation locations. The average of the 3 measurements for each specimen was utilized to determine the Vickers hardness value. The data were analyzed using two-way ANOVA and Tukey post hoc tests. Results: In the case of resin cements with underlying thicknesses of 0.5 mm and 1 mm, the groups GC Cerasmart and Vita Enamic demonstrated significantly higher average microhardness in comparison to the Lava Ultimate group (P < .05). Compared to the GC Cerasmart and Vita Enamic groups, the Lava Ultimate group’s mean microhardness of the resin cements for a thickness of 1.5 mm was significantly lower (P < .05). Conclusion: Resin matrix ceramics thickness and type had a significant effect on microhardness values in all kinds of RMC. Cite this article as: Göktepe B, Çelik E, Gönüldaş F. Effect of thickness of resin matrix ceramics on polymerization of resin cements. Essent Dent. 2025, 4, 0052, doi: 10.5152/EssentDent.2025.25052.
- 6 October 2021
- Published by Wiley in Microscopy Research and Technique
- Vol. 85 (3) , 840-847
The effect of different cleaning agents and resin cement materials on the bond strength of contaminated zirconia
The purpose of this study was to examine the effect of different cleaning methods and resin cements on the shear bond strength (SBS) of contaminated zirconia. A total of 92 disc‐shaped zirconia specimens were contaminated with different procedures. Then, the specimens were grouped according to cleaning methods and resin cements: no cleaning + Variolink Esthetic DC (CNV), no cleaning + Panavia V5 (CNP), sandblasted + Variolink Esthetic DC (SBV), sandblasted + Panavia V5 (SBP), Ivoclean + Variolink Esthetic DC (ICV), Ivoclean + Panavia V5 (ICP), Katana Cleaner + Variolink Esthetic DC (KCV), and Katana Cleaner + Panavia V5 (KCP). Following an aging protocol in a 37°C for 1 week, SBS analysis was performed with a universal test machine. For the surface topography and elemental analysis, scanning electron microscopy and energy‐dispersive X‐ray spectroscopy (EDS) were used. Significance was evaluated as p < .05 and p < .01. The highest SBS results were found in the SBP group, showing a statistically significant difference from all other groups (p < .05). For the same cleaning method, Panavia V5 showed statistically significantly higher SBS values than Variolink Esthetic DC (p < .01), except the CNP–CNV (p = .880) and KCP–KCV (p = .082) groups. The most detected surface elements by EDS were Zr, O, C, and N, respectively. The contaminated zirconia surfaces must be cleaned for successful adhesion. The use of phosphate‐containing adhesives in combination with sandblasting will increase the adhesion strength, and universal cleaning agents can be a good alternative to sandblasting.
- 6 October 2021
- Published by Wiley in Microscopy Research and Technique
- Vol. 85 (3) , 840-847
The effect of different cleaning agents and resin cement materials on the bond strength of contaminated zirconia
The purpose of this study was to examine the effect of different cleaning methods and resin cements on the shear bond strength (SBS) of contaminated zirconia. A total of 92 disc‐shaped zirconia specimens were contaminated with different procedures. Then, the specimens were grouped according to cleaning methods and resin cements: no cleaning + Variolink Esthetic DC (CNV), no cleaning + Panavia V5 (CNP), sandblasted + Variolink Esthetic DC (SBV), sandblasted + Panavia V5 (SBP), Ivoclean + Variolink Esthetic DC (ICV), Ivoclean + Panavia V5 (ICP), Katana Cleaner + Variolink Esthetic DC (KCV), and Katana Cleaner + Panavia V5 (KCP). Following an aging protocol in a 37°C for 1 week, SBS analysis was performed with a universal test machine. For the surface topography and elemental analysis, scanning electron microscopy and energy‐dispersive X‐ray spectroscopy (EDS) were used. Significance was evaluated as p < .05 and p < .01. The highest SBS results were found in the SBP group, showing a statistically significant difference from all other groups (p < .05). For the same cleaning method, Panavia V5 showed statistically significantly higher SBS values than Variolink Esthetic DC (p < .01), except the CNP–CNV (p = .880) and KCP–KCV (p = .082) groups. The most detected surface elements by EDS were Zr, O, C, and N, respectively. The contaminated zirconia surfaces must be cleaned for successful adhesion. The use of phosphate‐containing adhesives in combination with sandblasting will increase the adhesion strength, and universal cleaning agents can be a good alternative to sandblasting.
- Open Access
- 1 January 2021
- Published by Termedia Sp. z.o.o. in Journal of Stomatology
- Vol. 74 (2) , 89-94
Evaluation of bond strength of resin nano-ceramic as post material
Introduction Different usage areas of newly developed restorative materials have increased.. Objectives: The purpose of this study was to investigate usability of a newly produced resin nano-ceramic (RNC) as a post material, and how to increase bond strength of different post systems to root...
- 1 January 2021
- Published by Termedia Sp. z.o.o. in Journal of Stomatology
- Vol. 74 (2) , 89-94
Open AccessEvaluation of bond strength of resin nano-ceramic as post material
Introduction Different usage areas of newly developed restorative materials have increased.. Objectives: The purpose of this study was to investigate usability of a newly produced resin nano-ceramic (RNC) as a post material, and how to increase bond strength of different post systems to root...
- 1 August 2020
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 7 (2) , 200-205
Materyal Kalınlığının Rezin Matriks Seramik Blokların Renk Değişimi Üzerine Etkisi
Amaç: Estetik olarak başarılı bir restorasyonun doğal diş morfolojisine benzer olmasının yanında, doğal diş dokusuna benzer renk karakterine sahip olması beklenir. Bu çalışmanın amacı farklı yapılara sahip rezin matriks seramik materyallerinin renk parametreleri ve renk değişimi üzerinde materyal kalınlığının etkisini değerlendirmektir.Gereç ve Yöntemler: Bu çalışmada 3 farklı yapıya sahip üç farklı kalınlıkta ve 8 mm ± 0,2 mm çapında toplam 90 adet A2 renginde dairesel rezin matriks seramik örnekler kullanıldı. Örnekler farklı yapı ve kalınlıklarına göre her grupta 10 ar adet örnek olacak şekilde 9 alt gruba ayrıldı. Örneklerin renk parametreleri (L*,a* ve b*) spektrofotometre cihazı kullanılarak tespit edildi ve cihaz restorasyon moduna getirilerek A2 rengine göre örneklerin renk değişimleri değerleri tespit edildi. Ayrıca örneklerin hue ve chroma değerleri de elde edilen a* ve b* değerleri kullanılarak hesaplandı. Elde edilen veriler iki yönlü varyans analizi (Two-way ANOVA) ve Tukey çoklu karşılaştırma testi ile p˂0,05 anlamlılık düzeyinde değerlendirildi.Bulgular: İstatistiksel analiz sonuçlarına göre L* değeri için materyal faktörünün etkili olmadığı, kalınlık faktörü ve kalınlıkXmateryal faktör etkileşiminin anlamlı olduğu görüldü (p˂0,05). a*, b*, hue, chroma ve ΔE değerleri için materyal faktörü, kalınlık faktörü ve kalınlıkXmateryal faktör etkileşiminin anlamlı olduğu görüldü (p˂0,05). Gruplar içerisinde sadece Grup E 1.5 mm kalınlığındaki örneklerden elde edilen ortalama ΔE değerinin klinik olarak kabul edilebilir sınırların altında olduğu tespit edildi. Sonuç: Materyal tipi ve kalınlığı rezin matriks seramiklerin renk karakteri üzerinde anlamlı bir etkiye sahiptir. Grupların renk parametre değişimleri için kritik kalınlık değeri 1mm dir.
- 1 August 2020
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 7 (2) , 200-205
Materyal Kalınlığının Rezin Matriks Seramik Blokların Renk Değişimi Üzerine Etkisi
Amaç: Estetik olarak başarılı bir restorasyonun doğal diş morfolojisine benzer olmasının yanında, doğal diş dokusuna benzer renk karakterine sahip olması beklenir. Bu çalışmanın amacı farklı yapılara sahip rezin matriks seramik materyallerinin renk parametreleri ve renk değişimi üzerinde materyal kalınlığının etkisini değerlendirmektir.Gereç ve Yöntemler: Bu çalışmada 3 farklı yapıya sahip üç farklı kalınlıkta ve 8 mm ± 0,2 mm çapında toplam 90 adet A2 renginde dairesel rezin matriks seramik örnekler kullanıldı. Örnekler farklı yapı ve kalınlıklarına göre her grupta 10 ar adet örnek olacak şekilde 9 alt gruba ayrıldı. Örneklerin renk parametreleri (L*,a* ve b*) spektrofotometre cihazı kullanılarak tespit edildi ve cihaz restorasyon moduna getirilerek A2 rengine göre örneklerin renk değişimleri değerleri tespit edildi. Ayrıca örneklerin hue ve chroma değerleri de elde edilen a* ve b* değerleri kullanılarak hesaplandı. Elde edilen veriler iki yönlü varyans analizi (Two-way ANOVA) ve Tukey çoklu karşılaştırma testi ile p˂0,05 anlamlılık düzeyinde değerlendirildi.Bulgular: İstatistiksel analiz sonuçlarına göre L* değeri için materyal faktörünün etkili olmadığı, kalınlık faktörü ve kalınlıkXmateryal faktör etkileşiminin anlamlı olduğu görüldü (p˂0,05). a*, b*, hue, chroma ve ΔE değerleri için materyal faktörü, kalınlık faktörü ve kalınlıkXmateryal faktör etkileşiminin anlamlı olduğu görüldü (p˂0,05). Gruplar içerisinde sadece Grup E 1.5 mm kalınlığındaki örneklerden elde edilen ortalama ΔE değerinin klinik olarak kabul edilebilir sınırların altında olduğu tespit edildi. Sonuç: Materyal tipi ve kalınlığı rezin matriks seramiklerin renk karakteri üzerinde anlamlı bir etkiye sahiptir. Grupların renk parametre değişimleri için kritik kalınlık değeri 1mm dir.
- 17 March 2020
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 32 (5) , 530-535
Influence of bleaching agents on the color change and translucency of resin matrix ceramics
Objective: The aim of this study was to investigate the color change, translucency, and whiteness index of three different resin matrix ceramics and a resin composite subjected to different bleaching agents.Materials and Methods: Twenty disc‐shaped specimens (A2 shaded) for three different resin matrix ceramic brands (Groups Ena, Ulti, and Cera) (totally 60) were prepared using the CAD/CAM technique and 20 nanofiller composite specimens (Group Comp) (A2 shaded) with the same dimensions were prepared as the control group. The color change (∆E00), relative translucency parameter (RTP), and whiteness index (WID) of the specimens initial and after different bleaching procedures (home‐bleaching and office‐bleaching) were calculated using ∆E00, TP00, and WID formulas. Two‐way analysis of variance (ANOVA) and multiple comparison test with Bonferroni correction (α = .05) at the significance level of P < .05 were performed for the comparisons of ∆E00 values. The RTP and WID values were evaluated by using repeated measures ANOVA and multiple‐comparison test with Bonferroni corrections (α = .05) at the significance level of P < .05.Results: Bleaching procedure and material type were found to be significant regardless of bleaching type for RTP and WID values. Material type has a significant effect on the ∆E00 values. The highest color change values were determined in Group Comp (P < .05).Conclusions: Bleaching procedures significantly affected the RTP values of Groups Ulti and Cera (P < .05). ∆E00 values for the resin matrix ceramics after the bleaching procedures were below the clinically acceptable values, regardless of the bleaching agent.Clinical Significance: Optically, materials such as resin matrix ceramics have properties different from not only enamel and dentin but also among themselves. The possible effect of bleaching agents on these materials should be considered carefully while choosing the restorative material.
- 17 March 2020
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 32 (5) , 530-535
Influence of bleaching agents on the color change and translucency of resin matrix ceramics
Objective: The aim of this study was to investigate the color change, translucency, and whiteness index of three different resin matrix ceramics and a resin composite subjected to different bleaching agents.Materials and Methods: Twenty disc‐shaped specimens (A2 shaded) for three different resin matrix ceramic brands (Groups Ena, Ulti, and Cera) (totally 60) were prepared using the CAD/CAM technique and 20 nanofiller composite specimens (Group Comp) (A2 shaded) with the same dimensions were prepared as the control group. The color change (∆E00), relative translucency parameter (RTP), and whiteness index (WID) of the specimens initial and after different bleaching procedures (home‐bleaching and office‐bleaching) were calculated using ∆E00, TP00, and WID formulas. Two‐way analysis of variance (ANOVA) and multiple comparison test with Bonferroni correction (α = .05) at the significance level of P < .05 were performed for the comparisons of ∆E00 values. The RTP and WID values were evaluated by using repeated measures ANOVA and multiple‐comparison test with Bonferroni corrections (α = .05) at the significance level of P < .05.Results: Bleaching procedure and material type were found to be significant regardless of bleaching type for RTP and WID values. Material type has a significant effect on the ∆E00 values. The highest color change values were determined in Group Comp (P < .05).Conclusions: Bleaching procedures significantly affected the RTP values of Groups Ulti and Cera (P < .05). ∆E00 values for the resin matrix ceramics after the bleaching procedures were below the clinically acceptable values, regardless of the bleaching agent.Clinical Significance: Optically, materials such as resin matrix ceramics have properties different from not only enamel and dentin but also among themselves. The possible effect of bleaching agents on these materials should be considered carefully while choosing the restorative material.
- Open Access
- 17 December 2019
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 6 (3) , 324-334
Evaluation of the Effect of Crown/Implant Ratio on Stress Distribution in Dynamic Loaded Short Implants
Tr en Amaç: Bu çalışmanın amacı farklı kron/implant oranına sahip kısa implantlar üzerine uygulanan statik ve dinamik yüklerin implantı çevreleyen kemik doku ve implantta meydana getirdiği stresin sonlu elemanlar stres analiz yöntemiyle incelenmesidir. Gereç ve Yöntemler: Çalışmada, 4.1 mm çapında ve üç farklı uzunlukta (6 mm, 8 mm ve 10 mm) toplam 3 adet dental implant seçilmiştir. Bu üç implantın üzerine kron/implant oranı 1/1, 1.5/1 ve 2/1 olacak şekilde üçer adet alt birinci molar metal destekli seramik kron bilgisayar ortamında tasarlanmış ve implant destekli kronlar yine bilgisayar ortamında mandibula modeline yerleştirilerek toplam 9 adet çalışma modeli elde edilmiştir. Elde edilen bu modellere, vertikal ve oblik fonksiyonel kuvvetler uygulanarak, kortikal ve spongioz kemikte oluşan maksimum ve minimum asal stres değerlerine, implantta oluşan Von Mises stres değerlerine, implantlarda meydana gelen yorulma değerlerine kron/implant oranının etkisi üç boyutlu sonlu elemanlar stres analiz yöntemiyle incelenmiştir. Bulgular: Aynı miktarda kuvvet uygulanmasına rağmen, oblik yükleme yapılan modellerde dik yükleme yapılan modellere oranla implant sistemini oluşturan parçalarda ve kemik dokuda stres seviyelerinde belirgin bir artış olmuştur. Tüm modellerde, kron/implant oranındaki artış implant sistemini oluşturan parçalarda ve kemik dokuda stres seviyelerinde belirgin bir artışa neden olmuştur. Sonuçlar: Bu çalışmanın limitleri dahilinde elde edilen sayısal değerler, kron/implant oranının yük transfer mekanizmalarını ve implantların klinik başarı sürelerini etkilediğini göstermiştir. Mandibular molar bölgede tek diş eksikliklerinde uygulanacak implant tedavisinde 1/1 kron/implant oranının diğer oranlara göre daha iyi sonuçlar verdiği tespit edilmiştir. Kron/implant oranındaki artış stres miktarlarının artmasına ve implantların klinik başarı sürelerinin kısalmasına neden olmuştur. Anahtar Kelimeler: Dinamik yükleme, kısa implant, kron/implant oranı, sonlu eleman stres analizi Background: The aim of this study is to investigate the stress distribution in surrounding bone tissue and implant caused by static and dynamic loaded short implants with different crown/implant ratios by finite element stress analysis method. Methods: A total of 3 dental implants with a diameter of 4.1 mm and three different lengths (6 mm, 8 mm and 10 mm) were selected. These three implants are designed with three lower first molar metal-supported ceramic crowns on the crown/implant ratio of 1/1, 1.5 / 1 and 2/1 and implant-supported crowns were placed into the mandible model and a total of 9 study models were obtained. For the evaluation of the effect of crown/implant ratio, the vertical and oblique functional forces applied to these models, the maximum and minimum principle stress values in the cortical and spongious bone, the Von Mises stress values on the implant and the fatigue values occurring in the implants were investigated by three dimensional finite element stress analysis method. Results: Although the same amount of force was applied, there was a significant increase in stress levels in the parts of the implant system and in the bone tissue compared to the models with oblique loading. In all models, the increase in crown/implant ratio caused a significant increase in stress levels in the parts of the implant system and bone tissue. Conclusions: The numerical values obtained within the limitations of this study showed that the crown/implant ratio affected the load transfer mechanisms and the clinical success times of the implants. It has been determined that 1/1 crown/implant ratio gives better results compared to other ratios in implant treatment which will be applied in one tooth deficiency in mandibular molar region. The increase in crown/implant ratio resulted in increased stress levels and shortening the clinical success times of implants. Keywords: Dynamic loading, short implant, crown/implant ratio, finite element stress analysis.
- 17 December 2019
- Published by Selcuk Dental Journal in Selcuk Dental Journal
- Vol. 6 (3) , 324-334
Open AccessEvaluation of the Effect of Crown/Implant Ratio on Stress Distribution in Dynamic Loaded Short Implants
Tr en Amaç: Bu çalışmanın amacı farklı kron/implant oranına sahip kısa implantlar üzerine uygulanan statik ve dinamik yüklerin implantı çevreleyen kemik doku ve implantta meydana getirdiği stresin sonlu elemanlar stres analiz yöntemiyle incelenmesidir. Gereç ve Yöntemler: Çalışmada, 4.1 mm çapında ve üç farklı uzunlukta (6 mm, 8 mm ve 10 mm) toplam 3 adet dental implant seçilmiştir. Bu üç implantın üzerine kron/implant oranı 1/1, 1.5/1 ve 2/1 olacak şekilde üçer adet alt birinci molar metal destekli seramik kron bilgisayar ortamında tasarlanmış ve implant destekli kronlar yine bilgisayar ortamında mandibula modeline yerleştirilerek toplam 9 adet çalışma modeli elde edilmiştir. Elde edilen bu modellere, vertikal ve oblik fonksiyonel kuvvetler uygulanarak, kortikal ve spongioz kemikte oluşan maksimum ve minimum asal stres değerlerine, implantta oluşan Von Mises stres değerlerine, implantlarda meydana gelen yorulma değerlerine kron/implant oranının etkisi üç boyutlu sonlu elemanlar stres analiz yöntemiyle incelenmiştir. Bulgular: Aynı miktarda kuvvet uygulanmasına rağmen, oblik yükleme yapılan modellerde dik yükleme yapılan modellere oranla implant sistemini oluşturan parçalarda ve kemik dokuda stres seviyelerinde belirgin bir artış olmuştur. Tüm modellerde, kron/implant oranındaki artış implant sistemini oluşturan parçalarda ve kemik dokuda stres seviyelerinde belirgin bir artışa neden olmuştur. Sonuçlar: Bu çalışmanın limitleri dahilinde elde edilen sayısal değerler, kron/implant oranının yük transfer mekanizmalarını ve implantların klinik başarı sürelerini etkilediğini göstermiştir. Mandibular molar bölgede tek diş eksikliklerinde uygulanacak implant tedavisinde 1/1 kron/implant oranının diğer oranlara göre daha iyi sonuçlar verdiği tespit edilmiştir. Kron/implant oranındaki artış stres miktarlarının artmasına ve implantların klinik başarı sürelerinin kısalmasına neden olmuştur. Anahtar Kelimeler: Dinamik yükleme, kısa implant, kron/implant oranı, sonlu eleman stres analizi Background: The aim of this study is to investigate the stress distribution in surrounding bone tissue and implant caused by static and dynamic loaded short implants with different crown/implant ratios by finite element stress analysis method. Methods: A total of 3 dental implants with a diameter of 4.1 mm and three different lengths (6 mm, 8 mm and 10 mm) were selected. These three implants are designed with three lower first molar metal-supported ceramic crowns on the crown/implant ratio of 1/1, 1.5 / 1 and 2/1 and implant-supported crowns were placed into the mandible model and a total of 9 study models were obtained. For the evaluation of the effect of crown/implant ratio, the vertical and oblique functional forces applied to these models, the maximum and minimum principle stress values in the cortical and spongious bone, the Von Mises stress values on the implant and the fatigue values occurring in the implants were investigated by three dimensional finite element stress analysis method. Results: Although the same amount of force was applied, there was a significant increase in stress levels in the parts of the implant system and in the bone tissue compared to the models with oblique loading. In all models, the increase in crown/implant ratio caused a significant increase in stress levels in the parts of the implant system and bone tissue. Conclusions: The numerical values obtained within the limitations of this study showed that the crown/implant ratio affected the load transfer mechanisms and the clinical success times of the implants. It has been determined that 1/1 crown/implant ratio gives better results compared to other ratios in implant treatment which will be applied in one tooth deficiency in mandibular molar region. The increase in crown/implant ratio resulted in increased stress levels and shortening the clinical success times of implants. Keywords: Dynamic loading, short implant, crown/implant ratio, finite element stress analysis.
- Open Access
- 31 May 2019
- Published by Cumhuriyet University in Cumhuriyet Dental Journal
- Vol. 22 (2) , 176-184
Optical Properties of Novel Resin Matrix Ceramic Systems at Different Thicknesses
Objectives: The purpose of this study was to investigate the effect of material and thickness on the translucency parameters (TP) and opalescence parameters (OP) for resin matrix ceramic blocks. Materials and Methods: 90 disc-shaped specimens (8 mm diameter and A2 shade, High Translucency) were fabricated from Vita Enamic, Lava Ultimate and GC Cerasmart resin-matrix ceramic blocks and prepared to thicknesses of 0.5 mm, 1 mm and 1.5 mm (n=10). A dental spectrophotometer (VITA Easyshade Advance) was used to calculate the TP and OP. All specimens were placed on white and black backgrounds. The color measurements were repeated three times for each of the specimens and the mean values of L, a and b were calculated. Data were analyzed by a two-way analysis of variance (ANOVA) and Tukey’s test. Results: For the 0.5 mm thickness groups, GC Cerasmart had the highest and Vita Enamic had the lowest TP values. For the 1 mm thickness groups, GC Cerasmart had the highest TP, whereas Vita Enamic had the lowest TP. For the 1.5 mm thickness groups, Lava Ultimate had the highest TP, whereas Vita Enamic had the lowest TP. For the 0.5 mm thickness groups, Vita Enamic, and GC Cerasmart had the highest and lowest OP, respectively. The OP values in the 1 mm thickness group of Vita Enamic groups were higher than the GC Cerasmart and Lava Ultimate groups. The OP values in the 1.5 mm thickness group Lava Ultimate group were higher than the GC Cerasmart and Vita Enamic groups. In all groups, the OP values showed an increase in parallel with the increase in thicknesses, in contrast, the TP values showed a decrease. Conclusions: Type and thickness of the resin matrix ceramics affect the optical properties of the materials.
- 31 May 2019
- Published by Cumhuriyet University in Cumhuriyet Dental Journal
- Vol. 22 (2) , 176-184
Open AccessOptical Properties of Novel Resin Matrix Ceramic Systems at Different Thicknesses
Objectives: The purpose of this study was to investigate the effect of material and thickness on the translucency parameters (TP) and opalescence parameters (OP) for resin matrix ceramic blocks. Materials and Methods: 90 disc-shaped specimens (8 mm diameter and A2 shade, High Translucency) were fabricated from Vita Enamic, Lava Ultimate and GC Cerasmart resin-matrix ceramic blocks and prepared to thicknesses of 0.5 mm, 1 mm and 1.5 mm (n=10). A dental spectrophotometer (VITA Easyshade Advance) was used to calculate the TP and OP. All specimens were placed on white and black backgrounds. The color measurements were repeated three times for each of the specimens and the mean values of L, a and b were calculated. Data were analyzed by a two-way analysis of variance (ANOVA) and Tukey’s test. Results: For the 0.5 mm thickness groups, GC Cerasmart had the highest and Vita Enamic had the lowest TP values. For the 1 mm thickness groups, GC Cerasmart had the highest TP, whereas Vita Enamic had the lowest TP. For the 1.5 mm thickness groups, Lava Ultimate had the highest TP, whereas Vita Enamic had the lowest TP. For the 0.5 mm thickness groups, Vita Enamic, and GC Cerasmart had the highest and lowest OP, respectively. The OP values in the 1 mm thickness group of Vita Enamic groups were higher than the GC Cerasmart and Lava Ultimate groups. The OP values in the 1.5 mm thickness group Lava Ultimate group were higher than the GC Cerasmart and Vita Enamic groups. In all groups, the OP values showed an increase in parallel with the increase in thicknesses, in contrast, the TP values showed a decrease. Conclusions: Type and thickness of the resin matrix ceramics affect the optical properties of the materials.
- 9 March 2019
- Published by Wiley in Color Research & Application
- Vol. 44 (3) , 473-478
Do repeated firings affect the color properties of porcelain‐fused‐metal restorations that are fabricated differently?
Repeated firings can affect the quality of the porcelain color. The purpose of this study is to evaluate the effect of repeated firings on the color changes of porcelain‐fused‐metal restorations that are manufactured using different methods. A total of 60 cylindrical shaped cobalt–chromium alloys (Ø = 10 mm and h = 1.5 mm) were fabricated using casting (C), milling (M), direct metal laser sintering with and without annealing (EL+, EL‐), and selective laser melting with and without annealing (CL+, CL‐). The samples were veneered with A2 (as indicated by the Vita Shade Guide) dentin porcelain of 2 mm thickness. Then the samples subjected to the repeated firings (2nd, 4th, 6th, 8th, and 10th), and the color of each sample was recorded using a spectrophotometer. The CIEDE2000 (ΔE00) formula was used to calculate color differences of the samples on repeated firings. Repeated measures analysis of variance (ANOVA) and post‐hoc Tukey's test were utilized to analyze the results (a = 05). The L*, a*, and b* values of porcelain‐fused‐metal specimens were significantly affected by the number of firings (P < 0.001) and fabrication techniques (P < 0.001). The ΔE00 values for C, M, CL‐, and EL‐ groups after 10th firing were above 0.8 unit, which indicates that visually perceivable color differences are clinically acceptable. On the other hand, the ΔE00 values for CL+ and EL+ groups were above the PT value after 8th repeated firings. The color properties of porcelain‐fused‐metal restorations were affected by the fabrication techniques and the number of firings.
- 9 March 2019
- Published by Wiley in Color Research & Application
- Vol. 44 (3) , 473-478
Do repeated firings affect the color properties of porcelain‐fused‐metal restorations that are fabricated differently?
Repeated firings can affect the quality of the porcelain color. The purpose of this study is to evaluate the effect of repeated firings on the color changes of porcelain‐fused‐metal restorations that are manufactured using different methods. A total of 60 cylindrical shaped cobalt–chromium alloys (Ø = 10 mm and h = 1.5 mm) were fabricated using casting (C), milling (M), direct metal laser sintering with and without annealing (EL+, EL‐), and selective laser melting with and without annealing (CL+, CL‐). The samples were veneered with A2 (as indicated by the Vita Shade Guide) dentin porcelain of 2 mm thickness. Then the samples subjected to the repeated firings (2nd, 4th, 6th, 8th, and 10th), and the color of each sample was recorded using a spectrophotometer. The CIEDE2000 (ΔE00) formula was used to calculate color differences of the samples on repeated firings. Repeated measures analysis of variance (ANOVA) and post‐hoc Tukey's test were utilized to analyze the results (a = 05). The L*, a*, and b* values of porcelain‐fused‐metal specimens were significantly affected by the number of firings (P < 0.001) and fabrication techniques (P < 0.001). The ΔE00 values for C, M, CL‐, and EL‐ groups after 10th firing were above 0.8 unit, which indicates that visually perceivable color differences are clinically acceptable. On the other hand, the ΔE00 values for CL+ and EL+ groups were above the PT value after 8th repeated firings. The color properties of porcelain‐fused‐metal restorations were affected by the fabrication techniques and the number of firings.