Patricia Petromilli Nordi Sasso Garcia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Patricia Petromilli Nordi Sasso Garcia has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
- Juliana Alvares Duarte Bonini Campos
Universidade Estadual Paulista, Brazil
13 shared publications - Júlia Margato Pazos
Department of Social Dentistry São Paulo State University (UNESP), School of Dentistry Araraquara São Paulo Brazil
13 shared publications - Danielle Wajngarten
Sao Paulo State University
10 shared publications Danielle Wajngarten
Department of Social Dentistry, School of Dentistry of Araraquara, São Paulo State University (UNESP), SP, Brazil
9 shared publicationsJúlia Margato Pazos
Department of Social Dentistry, School of Dentistry, São Paulo State University (Unesp), Araraquara, São Paulo, Brazil
8 shared publications- Lívia Nordi Dovigo
Universidade Estadual Paulista (UNESP)
5 shared publications
Latest Publications
- 30 January 2026
- Published by Sciencedomain International in Journal of Advances in Medicine and Medical Research
- Vol. 38 (2) , 155-167
Effect of Different Types of Stools on Working Posture, Discomfort and Productivity in Dentistry
Objective: This study evaluated different stools on working posture, discomfort and productivity during cavity preparations. Methods: An experimental laboratory-based simulated study was performed. The response variables were the variation in bilateral muscle contraction of the abdominal, lumbar, and posterior thigh regions using surface thermography as proxy measure; the risk of developing musculoskeletal disorders in the upper limbs using the Rapid Upper Limb Assessment; adherence to ergonomic posture requirements through the modified Compliance Assessment Dental Ergonomic Posture; angular deviation from the neutral position of the neck and trunk; perception of discomfort in the abdominal, lower back, and thighs using the visual analogue scale; and productivity. Independent variables were the type of stool (conventional, saddle, or Seatball) and arch (upper or lower). A single operator performed class I tooth preparations on arch simulator plates during 90-minutes per period. For each experimental condition, 10 postural assessment periods were used (N=60 postures). Descriptive statistics were analyzed, and the assumptions of normality and homoscedasticity were verified. Two-way parametric and non-parametric ANOVA with Tukey’s post-hoc test were performed (α=0.05). Results: There was no significant interaction between stool and arch for any evaluated variable (p=0.449–0.915). There was higher muscle contraction during work with conventional stool for the lumbar region (p<0.001), better angular deviation from the neutral position of trunk (p<0.001) and better compliance with ergonomic posture requirements (p=0.004) when working on the lower arch. It was also observed an increased perception of discomfort in the thigh region with the saddle seat (p<0.001). Conclusion: The different types of stools influenced only muscle contraction and perceived discomfort. The conventional stool increased lumbar region muscle contraction, while the saddle seat produced greater discomfort in the thigh region. Procedures performed on the upper arch were associated with reduced compliance with ergonomic posture requirements and greater angular deviation of the trunk.
- 30 January 2026
- Published by Sciencedomain International in Journal of Advances in Medicine and Medical Research
- Vol. 38 (2) , 155-167
Effect of Different Types of Stools on Working Posture, Discomfort and Productivity in Dentistry
Objective: This study evaluated different stools on working posture, discomfort and productivity during cavity preparations. Methods: An experimental laboratory-based simulated study was performed. The response variables were the variation in bilateral muscle contraction of the abdominal, lumbar, and posterior thigh regions using surface thermography as proxy measure; the risk of developing musculoskeletal disorders in the upper limbs using the Rapid Upper Limb Assessment; adherence to ergonomic posture requirements through the modified Compliance Assessment Dental Ergonomic Posture; angular deviation from the neutral position of the neck and trunk; perception of discomfort in the abdominal, lower back, and thighs using the visual analogue scale; and productivity. Independent variables were the type of stool (conventional, saddle, or Seatball) and arch (upper or lower). A single operator performed class I tooth preparations on arch simulator plates during 90-minutes per period. For each experimental condition, 10 postural assessment periods were used (N=60 postures). Descriptive statistics were analyzed, and the assumptions of normality and homoscedasticity were verified. Two-way parametric and non-parametric ANOVA with Tukey’s post-hoc test were performed (α=0.05). Results: There was no significant interaction between stool and arch for any evaluated variable (p=0.449–0.915). There was higher muscle contraction during work with conventional stool for the lumbar region (p<0.001), better angular deviation from the neutral position of trunk (p<0.001) and better compliance with ergonomic posture requirements (p=0.004) when working on the lower arch. It was also observed an increased perception of discomfort in the thigh region with the saddle seat (p<0.001). Conclusion: The different types of stools influenced only muscle contraction and perceived discomfort. The conventional stool increased lumbar region muscle contraction, while the saddle seat produced greater discomfort in the thigh region. Procedures performed on the upper arch were associated with reduced compliance with ergonomic posture requirements and greater angular deviation of the trunk.
- Open Access
- 31 December 2025
- Published by Wiley in European Journal of Dental Education
- Vol. 30 (3) , 1316-1324
Training Program for the Use of Magnification Loupes in Dentistry
Introduction: Although magnification loupes offer well‐documented advantages, their initial adaptation can be challenging, often deterring widespread adoption. Without sufficient training during this critical period, students may feel inadequately prepared, limiting their ability to benefit from loupes and contributing to reluctance in their use. To address this issue, this study designed and evaluated a training program focused on the use of Galilean loupes, aiming to enhance the ergonomic posture of dental students. Methods: Thirty‐one second‐year dental students were divided into an experimental group and a control group. Response variables were compliance with ergonomic posture requirements, neck angular deviation, muscle contraction of the back and neck and self‐reported perception of pain/discomfort. The independent variables were training program and timing of evaluation (T0, before the program; T1, 1 week after the program). Data analysis used mixed repeated‐measures ANOVA and nonparametric mixed repeated‐measures ANOVA ( α = 5%). Results: For posture compliance, the experimental group showed improved scores at T1 ( p = 0.044), while the control group showed no change. Angular deviation was smaller at T1. No significant interaction was found for muscle contractions. Pain/discomfort perception significantly decreased over time ( p = 0.006). Discussion: The training program significantly improved students' compliance to ergonomic posture requirements, though it had no measurable effect on the other variables assessed. These findings are noteworthy, as they indicate that targeted training in the use of magnification loupes can effectively improve students' compliance to ergonomic posture standards. Notably, changes in neck angular deviation and reported pain or discomfort were associated with the timing of assessment rather than the training itself. This suggests that the use of magnification loupes may contribute to reducing angular deviation in the neck as students gain confidence and become more accustomed to magnification. Overall, the training program demonstrated a clear benefit in supporting ergonomic compliance among dental students.
- 31 December 2025
- Published by Wiley in European Journal of Dental Education
- Vol. 30 (3) , 1316-1324
Open AccessTraining Program for the Use of Magnification Loupes in Dentistry
Introduction: Although magnification loupes offer well‐documented advantages, their initial adaptation can be challenging, often deterring widespread adoption. Without sufficient training during this critical period, students may feel inadequately prepared, limiting their ability to benefit from loupes and contributing to reluctance in their use. To address this issue, this study designed and evaluated a training program focused on the use of Galilean loupes, aiming to enhance the ergonomic posture of dental students. Methods: Thirty‐one second‐year dental students were divided into an experimental group and a control group. Response variables were compliance with ergonomic posture requirements, neck angular deviation, muscle contraction of the back and neck and self‐reported perception of pain/discomfort. The independent variables were training program and timing of evaluation (T0, before the program; T1, 1 week after the program). Data analysis used mixed repeated‐measures ANOVA and nonparametric mixed repeated‐measures ANOVA ( α = 5%). Results: For posture compliance, the experimental group showed improved scores at T1 ( p = 0.044), while the control group showed no change. Angular deviation was smaller at T1. No significant interaction was found for muscle contractions. Pain/discomfort perception significantly decreased over time ( p = 0.006). Discussion: The training program significantly improved students' compliance to ergonomic posture requirements, though it had no measurable effect on the other variables assessed. These findings are noteworthy, as they indicate that targeted training in the use of magnification loupes can effectively improve students' compliance to ergonomic posture standards. Notably, changes in neck angular deviation and reported pain or discomfort were associated with the timing of assessment rather than the training itself. This suggests that the use of magnification loupes may contribute to reducing angular deviation in the neck as students gain confidence and become more accustomed to magnification. Overall, the training program demonstrated a clear benefit in supporting ergonomic compliance among dental students.
- Open Access
- 3 July 2025
- Published by Wiley in European Journal of Dental Education
- Vol. 30 (2) , 639-643
Effects of Galilean Loupes on Dental Students' Posture and Cavity Preparation Quality
Objectives: This study investigated the effect of different magnification levels of the Galilean system loupes on dental students' working posture and the quality of cavity preparations. Materials and Methods: An experimental study was conducted, with the response variables being compliance with ergonomic posture requirements (measured using the Compliance Assessment of Dental Ergonomic Posture—CADEP) and quality of cavity preparation (assessed using the Class One Cavity Preparation Assessment—COCA). The independent variable was the magnification level of the Galilean system loupe, tested at four levels: naked eyes, 2.5×, 3.0×, and 3.5×. Second‐year undergraduate dental students ( N = 40) participated and were divided into Groups I and II. Each student performed cavity preparation at each magnification level, resulting in four preparations per student. Group I started with the naked eye, whereas Group II began with loupes at different magnifications. After 1 week, the conditions were reversed. Working postures were captured in photographs and analysed using CADEP, whereas the quality of the cavity preparations was assessed using COCA. After verifying normality and sphericity, a one‐way repeated measures ANOVA with Bonferroni post hoc test ( α = 5%) was conducted. Results: The second results showed that at 3.0× magnification, both compliance with ergonomic posture and the quality of class I cavity preparations were significantly superior compared to the naked eye ( p < 0.001). Conclusions: Galilean loupes of 3.0× provided the best balance, improved working posture, and enhanced procedural quality.
- 3 July 2025
- Published by Wiley in European Journal of Dental Education
- Vol. 30 (2) , 639-643
Open AccessEffects of Galilean Loupes on Dental Students' Posture and Cavity Preparation Quality
Objectives: This study investigated the effect of different magnification levels of the Galilean system loupes on dental students' working posture and the quality of cavity preparations. Materials and Methods: An experimental study was conducted, with the response variables being compliance with ergonomic posture requirements (measured using the Compliance Assessment of Dental Ergonomic Posture—CADEP) and quality of cavity preparation (assessed using the Class One Cavity Preparation Assessment—COCA). The independent variable was the magnification level of the Galilean system loupe, tested at four levels: naked eyes, 2.5×, 3.0×, and 3.5×. Second‐year undergraduate dental students ( N = 40) participated and were divided into Groups I and II. Each student performed cavity preparation at each magnification level, resulting in four preparations per student. Group I started with the naked eye, whereas Group II began with loupes at different magnifications. After 1 week, the conditions were reversed. Working postures were captured in photographs and analysed using CADEP, whereas the quality of the cavity preparations was assessed using COCA. After verifying normality and sphericity, a one‐way repeated measures ANOVA with Bonferroni post hoc test ( α = 5%) was conducted. Results: The second results showed that at 3.0× magnification, both compliance with ergonomic posture and the quality of class I cavity preparations were significantly superior compared to the naked eye ( p < 0.001). Conclusions: Galilean loupes of 3.0× provided the best balance, improved working posture, and enhanced procedural quality.
- 15 June 2025
- Published by Elsevier in Applied Ergonomics
- Vol. 129, 104579
Magnification of the Galilean system and work posture in dental students: a crossover study
- 15 June 2025
- Published by Elsevier in Applied Ergonomics
- Vol. 129, 104579
Magnification of the Galilean system and work posture in dental students: a crossover study
- 22 April 2025
- Published by Wiley in European Journal of Dental Education
- Vol. 30 (1) , 155-162
Effect of Different Types of Dental Stools on Muscle Activity During Execution of Preclinical Procedures
Objectives: This study investigated the effect of different dental stools on muscular activity in the upper and abdominal regions, and the angular deviation of the neck and trunk during preclinical procedures. Material and Methods: An experimental laboratory study was conducted with the response variables including (1) muscular activity of the trapezius, rectus abdominis, and paravertebral muscles, measured by surface electromyography and (2) angular deviation from the neutral position of the neck and trunk. The independent variable was the type of dental stool (conventional stool, saddle seat, or seatball). Class I preparations were performed ( N = 120) on artificial first molars. Working postures were recorded and angular deviations were measured using the “ Postural Assessment Software— SAPO .” A one‐way analysis of variance, Tukey and Games‐Howell post hoc tests were performed. Results: Stool type did not affect the activity of the paravertebral and rectus abdominis muscles ( p > 0.05). Less activity was observed in the right trapezius muscle during cavity preparations of teeth 26 ( p = 0.006) and 36 ( p = 0.046) with conventional stool. The saddle seat led to less activity in the left trapezius during work on tooth 26 ( p = 0.040). For the neck, a greater angular deviation was observed with the saddle seat on the upper left hemiarch ( p = 0.020), and with the saddle seat and seatball on the lower left hemiarch ( p = 0.019). The trunk showed greater angular deviation during work with the saddle seat and seatball for all hemiarches ( p < 0.001–0.003). Conclusion: Stool type did not influence muscle activity, but the unconventional stools led to greater angular deviations in the neck and trunk.
- 22 April 2025
- Published by Wiley in European Journal of Dental Education
- Vol. 30 (1) , 155-162
Effect of Different Types of Dental Stools on Muscle Activity During Execution of Preclinical Procedures
Objectives: This study investigated the effect of different dental stools on muscular activity in the upper and abdominal regions, and the angular deviation of the neck and trunk during preclinical procedures. Material and Methods: An experimental laboratory study was conducted with the response variables including (1) muscular activity of the trapezius, rectus abdominis, and paravertebral muscles, measured by surface electromyography and (2) angular deviation from the neutral position of the neck and trunk. The independent variable was the type of dental stool (conventional stool, saddle seat, or seatball). Class I preparations were performed ( N = 120) on artificial first molars. Working postures were recorded and angular deviations were measured using the “ Postural Assessment Software— SAPO .” A one‐way analysis of variance, Tukey and Games‐Howell post hoc tests were performed. Results: Stool type did not affect the activity of the paravertebral and rectus abdominis muscles ( p > 0.05). Less activity was observed in the right trapezius muscle during cavity preparations of teeth 26 ( p = 0.006) and 36 ( p = 0.046) with conventional stool. The saddle seat led to less activity in the left trapezius during work on tooth 26 ( p = 0.040). For the neck, a greater angular deviation was observed with the saddle seat on the upper left hemiarch ( p = 0.020), and with the saddle seat and seatball on the lower left hemiarch ( p = 0.019). The trunk showed greater angular deviation during work with the saddle seat and seatball for all hemiarches ( p < 0.001–0.003). Conclusion: Stool type did not influence muscle activity, but the unconventional stools led to greater angular deviations in the neck and trunk.
- Open Access
- 4 December 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (12) , e0311973
Effectiveness of manual dexterity assessment methods for preclinical training in Dentistry
Objective: This study aimed to verify the predictive capacity of manual dexterity assessment methods for pre-clinical training in Dentistry. Method: Students from the fifth year of the undergraduate course in Dentistry (N = 95) participated in this study. Manual dexterity was investigated as a variable of interest, measured by the O’Connor Finger Dexterity Test methods—Model 32021, Purdue Pegboard Test—Model 32020A, Dental Manual Dexterity Assessment—DMDA, Class One Cavity Preparation Assessent—COCA and Class One Composite Resin Restoration Assessment—COCRA. The average score obtained in the evaluation of the quality of the cavity preparations and restorations was considered as gold standard, and from these data the sensitivity and specificity of the tests were estimated. Receiver Operating Characteristic (ROC) curves were constructed to assess the diagnostic performance of each dexterity test. The analysis included calculating the Area Under the Curve (AUROC) to evaluate their discriminative power, and cutoff points were determined that optimize the balance between sensitivity and specificity. Results: The DMDA test showed better performance, with statistical significance (p <0.001) and acceptable predictive ability (AUROC = 0.775), while the O’Connor test (AUROC = 0.644, p = 0.050) and Purdue Pegboard test (Purdue 1: AUROC = 0.542, p = 0.560; Purdue 2: AUROC = 0.564, p = 0.423; Purdue 3: AUROC = 0.517, p = 0.828; Purdue 4: AUROC = 0.608, p = 0.083) were not statistically significant. Conclusion: The DMDA test presented the best performance, with statistical significance and acceptable discrimination, showing greater effectiveness for assessing students’ manual dexterity. Therefore, the implementation of the DMDA test can significantly contribute to the early identification of motor dexterity difficulties in dental students, enabling more effective and targeted interventions.
- 4 December 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (12) , e0311973
Open AccessEffectiveness of manual dexterity assessment methods for preclinical training in Dentistry
Objective: This study aimed to verify the predictive capacity of manual dexterity assessment methods for pre-clinical training in Dentistry. Method: Students from the fifth year of the undergraduate course in Dentistry (N = 95) participated in this study. Manual dexterity was investigated as a variable of interest, measured by the O’Connor Finger Dexterity Test methods—Model 32021, Purdue Pegboard Test—Model 32020A, Dental Manual Dexterity Assessment—DMDA, Class One Cavity Preparation Assessent—COCA and Class One Composite Resin Restoration Assessment—COCRA. The average score obtained in the evaluation of the quality of the cavity preparations and restorations was considered as gold standard, and from these data the sensitivity and specificity of the tests were estimated. Receiver Operating Characteristic (ROC) curves were constructed to assess the diagnostic performance of each dexterity test. The analysis included calculating the Area Under the Curve (AUROC) to evaluate their discriminative power, and cutoff points were determined that optimize the balance between sensitivity and specificity. Results: The DMDA test showed better performance, with statistical significance (p <0.001) and acceptable predictive ability (AUROC = 0.775), while the O’Connor test (AUROC = 0.644, p = 0.050) and Purdue Pegboard test (Purdue 1: AUROC = 0.542, p = 0.560; Purdue 2: AUROC = 0.564, p = 0.423; Purdue 3: AUROC = 0.517, p = 0.828; Purdue 4: AUROC = 0.608, p = 0.083) were not statistically significant. Conclusion: The DMDA test presented the best performance, with statistical significance and acceptable discrimination, showing greater effectiveness for assessing students’ manual dexterity. Therefore, the implementation of the DMDA test can significantly contribute to the early identification of motor dexterity difficulties in dental students, enabling more effective and targeted interventions.
- Open Access
Magnification in preclinical procedures: effect on muscle activity and angular deviations of the neck and trunk
Objectives This study aimed to assess the effects of different magnification systems on the angular deviations of the neck and trunk and the muscle activities of the upper back and neck during preclinical cavity preparation. Methods This was an experimental laboratory study, with the angular deviations from the neutral positions of the neck and trunk and the activities of the bilateral upper back (the descending and ascending trapezius) and neck (sternocleidomastoid) muscles as the dependent variables. The independent variables were the different magnification systems used (Simple, Galilean, and Keplerian loupes, with direct vision as the control) and prepared teeth (teeth 16, 26, 36, and 46). A dental mannequin phantom head with artificial resin teeth was used, and Class I cavity preparations for composite resin were performed on teeth 16, 26, 36, and 46 using a 1012 round diamond bur at low speed. To analyze the angular deviations, the postures adopted during the procedure were recorded using a tripod-mounted camera positioned to provide a lateral view of the operator. A trained researcher measured the angular deviations using the software entitled “Software for Postural Assessment”—SAPO (version 0.69). Bilateral muscle activity was assessed using surface electromyography. Descriptive statistical analysis was performed, and after verifying the assumptions of normality and homoscedasticity, two-way analysis of variance and the Tukey and Games-Howell post-hoc tests were used to compare the data (α=0.05). Results The angular deviation from the neutral position of the neck was found to be significantly higher during cavity preparations performed with the naked eye and the Simple loupe, irrespective of the prepared tooth. With regard to tooth location, the angular deviation of the neck was significantly greater during cavity preparation on teeth 16 and 26, and the angular deviation of the trunk was significantly greater during cavity preparation on tooth 26, regardless of the magnification system used. There were significant differences in right sternocleidomastoid muscle activity between the Simple, Galilean, and Keplerian loupes, with activity being the lowest for the Galilean loupe (p = 0.008). There were no significant differences in left sternocleidomastoid muscle activity between the loupes, regardless of the prepared tooth (p = 0.077). The activities of the bilateral descending trapezius and the right ascending trapezius muscles were significantly lower when the Galilean loupe was used (p < 0.010). Conclusion These results suggest that the Galilean loupe resulted in lower muscle activity in the neck and back regions and that the Galilean and Keplerian loupes resulted in less angular deviations of the neck and trunk during cavity preparation.
Open AccessMagnification in preclinical procedures: effect on muscle activity and angular deviations of the neck and trunk
Objectives This study aimed to assess the effects of different magnification systems on the angular deviations of the neck and trunk and the muscle activities of the upper back and neck during preclinical cavity preparation. Methods This was an experimental laboratory study, with the angular deviations from the neutral positions of the neck and trunk and the activities of the bilateral upper back (the descending and ascending trapezius) and neck (sternocleidomastoid) muscles as the dependent variables. The independent variables were the different magnification systems used (Simple, Galilean, and Keplerian loupes, with direct vision as the control) and prepared teeth (teeth 16, 26, 36, and 46). A dental mannequin phantom head with artificial resin teeth was used, and Class I cavity preparations for composite resin were performed on teeth 16, 26, 36, and 46 using a 1012 round diamond bur at low speed. To analyze the angular deviations, the postures adopted during the procedure were recorded using a tripod-mounted camera positioned to provide a lateral view of the operator. A trained researcher measured the angular deviations using the software entitled “Software for Postural Assessment”—SAPO (version 0.69). Bilateral muscle activity was assessed using surface electromyography. Descriptive statistical analysis was performed, and after verifying the assumptions of normality and homoscedasticity, two-way analysis of variance and the Tukey and Games-Howell post-hoc tests were used to compare the data (α=0.05). Results The angular deviation from the neutral position of the neck was found to be significantly higher during cavity preparations performed with the naked eye and the Simple loupe, irrespective of the prepared tooth. With regard to tooth location, the angular deviation of the neck was significantly greater during cavity preparation on teeth 16 and 26, and the angular deviation of the trunk was significantly greater during cavity preparation on tooth 26, regardless of the magnification system used. There were significant differences in right sternocleidomastoid muscle activity between the Simple, Galilean, and Keplerian loupes, with activity being the lowest for the Galilean loupe (p = 0.008). There were no significant differences in left sternocleidomastoid muscle activity between the loupes, regardless of the prepared tooth (p = 0.077). The activities of the bilateral descending trapezius and the right ascending trapezius muscles were significantly lower when the Galilean loupe was used (p < 0.010). Conclusion These results suggest that the Galilean loupe resulted in lower muscle activity in the neck and back regions and that the Galilean and Keplerian loupes resulted in less angular deviations of the neck and trunk during cavity preparation.
- 16 January 2024
- Published by Wiley in Journal of Dental Education
- Vol. 88 (4) , 461-467
The effect of Galilean magnification loupes on the visual acuity and working distance of dental students
Objective: This study aimed to evaluate the visual acuity and working distance of dental students using Galilean loupes at different magnification levels.Methods: The participants included 50 undergraduate dentistry students selected from each class in the second to fifth years (N = 200) of São Paulo State University, School of Dentistry, Araraquara. The response variables were (i) the working distance between the operator's eyes and the mouth of the dental phantom head, and (ii) visual acuity. The independent variables were the five levels of the Galilean magnification system (naked eye, Galilean loupe simulator without magnification, and Galilean loupes with 2.5×, 3.0×, or 3.5× magnification) and academic year. Visual acuity was measured using a miniature Snellen eye chart inserted into the Class I cavities of the maxillary molars. After verifying the assumptions of normality and sphericity, a mixed repeated measures analysis was performed (α = 0.05).Results: Statistical significance was found between the “magnification system” and “academic year” for visual acuity (p < 0.001). For the second‐, fourth‐, and fifth‐year participants, there were no significant differences in visual acuity between the naked eye and different magnifications of the Galilean loupes, which were superior to and significantly different from that of the loupe simulator. For the working distance, statistical significance was observed in the interaction between “magnification system” and “academic year” (p = 0.008). For the third‐, fourth‐, and fifth‐year participants, there was no significant difference in the working distance between the naked eye and different magnifications of the Galilean loupes, which were superior to and significantly different from that of the simulator.Conclusion: It was concluded that the different magnification levels of the Galilean loupes did not influence the visual acuity or distance between the eyes of the operator and the mouth of the dental phantom head in the evaluated students.
- 16 January 2024
- Published by Wiley in Journal of Dental Education
- Vol. 88 (4) , 461-467
The effect of Galilean magnification loupes on the visual acuity and working distance of dental students
Objective: This study aimed to evaluate the visual acuity and working distance of dental students using Galilean loupes at different magnification levels.Methods: The participants included 50 undergraduate dentistry students selected from each class in the second to fifth years (N = 200) of São Paulo State University, School of Dentistry, Araraquara. The response variables were (i) the working distance between the operator's eyes and the mouth of the dental phantom head, and (ii) visual acuity. The independent variables were the five levels of the Galilean magnification system (naked eye, Galilean loupe simulator without magnification, and Galilean loupes with 2.5×, 3.0×, or 3.5× magnification) and academic year. Visual acuity was measured using a miniature Snellen eye chart inserted into the Class I cavities of the maxillary molars. After verifying the assumptions of normality and sphericity, a mixed repeated measures analysis was performed (α = 0.05).Results: Statistical significance was found between the “magnification system” and “academic year” for visual acuity (p < 0.001). For the second‐, fourth‐, and fifth‐year participants, there were no significant differences in visual acuity between the naked eye and different magnifications of the Galilean loupes, which were superior to and significantly different from that of the loupe simulator. For the working distance, statistical significance was observed in the interaction between “magnification system” and “academic year” (p = 0.008). For the third‐, fourth‐, and fifth‐year participants, there was no significant difference in the working distance between the naked eye and different magnifications of the Galilean loupes, which were superior to and significantly different from that of the simulator.Conclusion: It was concluded that the different magnification levels of the Galilean loupes did not influence the visual acuity or distance between the eyes of the operator and the mouth of the dental phantom head in the evaluated students.
- Open Access
Effect of finger rest positions on upper limb muscle activity during pre-clinical procedures
Objectives: This study aimed to observe the effect of different finger rest positions on the muscular activity of the hand, forearm, arm, shoulder, thorax, and neck, as well as on the angular deviation from the neutral position of the neck, trunk, upper arm, and forearm on the working side during pre-clinical procedures. Methods: An experimental laboratory study was performed. Response variables were muscle activation of the abductor pollicis, brachioradialis, biceps brachii, deltoid, pectoralis major, and right sternocleidomastoid muscles and angular deviation from the neutral position of the neck, trunk, arm, and forearm during simulated clinical procedures. Independent variable was finger-rest position during cavity preparation (no finger rest, usual rest, and ergonomic rest). Class I cavity preparations (N = 120) were performed on artificial first molars (16, 26, 36, and 46) (N = 120). Muscular activation was assessed by surface electromyography and angular deviations using Software for Postural Assessment (SAPO) version 0.69. One-way analysis of variance and Tukey’s or Games-Howell’s post-hoc tests were performed (α = 0.05). Results: For the sternocleidomastoid muscle, there was no statistically significant difference between the different rest positions. For the deltoid muscle, work with no finger rest resulted in greater muscle activation (p < 0.001) during work on tooth 36. Regarding the pectoralis major and right brachioradialis muscles, we observed that for both teeth 16 and 26, working with ergonomic rest showed less muscle activation. Muscle activation of the right biceps brachii was higher for work with no rest in both the upper and lower arches, differing significantly only from the usual rest in tooth 16 (p < 0.001), usual rest and ergonomic rest in teeth 26 and 46 (p < 0.001), and only ergonomic rest in tooth 36 (p = 0.044). In the right abductor pollicis muscle, work with ergonomic rest resulted in less muscle activation for cavity preparation in teeth 16, 26, and 36, which was significantly different from work with no rest (p = 0.029, p < 0.001, and p = 0.013, respectively). Regarding angular deviation, it was observed that for tooth 16, there was a greater angular deviation of the arm when performing cavity preparations with no finger rest. For teeth 26 and 46, the ergonomic finger rest provided lower angular deviation from the neutral position of the right arm. For tooth 36, ergonomic rest provided less angular deviation from the neutral neck position. Conclusion: In general, the use of non-active finger rest during simulated cavity preparations, regardless of the type of rest, provided less muscle activation and angular deviation from the neutral position of the body’s upper extremity when performing pre-clinical procedures.
Open AccessEffect of finger rest positions on upper limb muscle activity during pre-clinical procedures
Objectives: This study aimed to observe the effect of different finger rest positions on the muscular activity of the hand, forearm, arm, shoulder, thorax, and neck, as well as on the angular deviation from the neutral position of the neck, trunk, upper arm, and forearm on the working side during pre-clinical procedures. Methods: An experimental laboratory study was performed. Response variables were muscle activation of the abductor pollicis, brachioradialis, biceps brachii, deltoid, pectoralis major, and right sternocleidomastoid muscles and angular deviation from the neutral position of the neck, trunk, arm, and forearm during simulated clinical procedures. Independent variable was finger-rest position during cavity preparation (no finger rest, usual rest, and ergonomic rest). Class I cavity preparations (N = 120) were performed on artificial first molars (16, 26, 36, and 46) (N = 120). Muscular activation was assessed by surface electromyography and angular deviations using Software for Postural Assessment (SAPO) version 0.69. One-way analysis of variance and Tukey’s or Games-Howell’s post-hoc tests were performed (α = 0.05). Results: For the sternocleidomastoid muscle, there was no statistically significant difference between the different rest positions. For the deltoid muscle, work with no finger rest resulted in greater muscle activation (p < 0.001) during work on tooth 36. Regarding the pectoralis major and right brachioradialis muscles, we observed that for both teeth 16 and 26, working with ergonomic rest showed less muscle activation. Muscle activation of the right biceps brachii was higher for work with no rest in both the upper and lower arches, differing significantly only from the usual rest in tooth 16 (p < 0.001), usual rest and ergonomic rest in teeth 26 and 46 (p < 0.001), and only ergonomic rest in tooth 36 (p = 0.044). In the right abductor pollicis muscle, work with ergonomic rest resulted in less muscle activation for cavity preparation in teeth 16, 26, and 36, which was significantly different from work with no rest (p = 0.029, p < 0.001, and p = 0.013, respectively). Regarding angular deviation, it was observed that for tooth 16, there was a greater angular deviation of the arm when performing cavity preparations with no finger rest. For teeth 26 and 46, the ergonomic finger rest provided lower angular deviation from the neutral position of the right arm. For tooth 36, ergonomic rest provided less angular deviation from the neutral neck position. Conclusion: In general, the use of non-active finger rest during simulated cavity preparations, regardless of the type of rest, provided less muscle activation and angular deviation from the neutral position of the body’s upper extremity when performing pre-clinical procedures.
- 25 May 2023
- Published by Sciencedomain International in Journal of Advances in Medicine and Medical Research
- Vol. 35 (15) , 71-78
Importance of Teaching Ergonomics in Dental School Education
Aims: The aim of this study was to present the prevalence of musculoskeletal symptoms in dental students and their ergonomics knowledge, the challenges of the implementation of ergonomics in dental school curriculum, and the teaching of ergonomics in dental courses. Methodology: This manuscript was supported by scientific evidence found in the literature obtained from Science Direct, Scientific Electronic Library Online (SCIELO), and National Library of Medicine (MEDLINE) databases, as well as the authors’ experience in ergonomics education and research studies. Results: Most dental students have reported pain in their neck, lower back, and shoulders. Although students have experienced musculoskeletal symptoms, they have a limited perception of work risk factors due to the lack of ergonomics education while in dental school. The challenges of its incorporation could be addressed through curricular revisions. Conclusion: Implementation of ergonomics in the dental curriculum at the beginning of preclinical training and its reinforcement later in clinical practice can prevent musculoskeletal disorders in dental students. Curricular revision needs to be accompanied by epidemiologic studies, faculty development, and timely evaluation in order to customize ergonomics educational programs in dental curriculum and identify areas of success as well as those needing improvement.
- 25 May 2023
- Published by Sciencedomain International in Journal of Advances in Medicine and Medical Research
- Vol. 35 (15) , 71-78
Importance of Teaching Ergonomics in Dental School Education
Aims: The aim of this study was to present the prevalence of musculoskeletal symptoms in dental students and their ergonomics knowledge, the challenges of the implementation of ergonomics in dental school curriculum, and the teaching of ergonomics in dental courses. Methodology: This manuscript was supported by scientific evidence found in the literature obtained from Science Direct, Scientific Electronic Library Online (SCIELO), and National Library of Medicine (MEDLINE) databases, as well as the authors’ experience in ergonomics education and research studies. Results: Most dental students have reported pain in their neck, lower back, and shoulders. Although students have experienced musculoskeletal symptoms, they have a limited perception of work risk factors due to the lack of ergonomics education while in dental school. The challenges of its incorporation could be addressed through curricular revisions. Conclusion: Implementation of ergonomics in the dental curriculum at the beginning of preclinical training and its reinforcement later in clinical practice can prevent musculoskeletal disorders in dental students. Curricular revision needs to be accompanied by epidemiologic studies, faculty development, and timely evaluation in order to customize ergonomics educational programs in dental curriculum and identify areas of success as well as those needing improvement.