AGArjan J. Geers

Arjan J. Geers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Arjan J. Geers has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Uncertainty quantification of wall shear stress in intracranial aneurysms using a data-driven statistical model of systemic blood flow variability

    by Ali Sarrami-Foroushani, Toni Lassila, Ali Gooya, Arjan J. Geers, Alejandro F. Frangi


  • Open Access

    Does Arterial Flow Rate Affect the Assessment of Flow-Diverter Stent Performance?

    by H.G. Morales, O. Bonnefous, A.J. Geers, O. Brina, V.M. Pereira, L. Spelle, J. Moret, I. Larrabide

    BACKGROUND AND PURPOSE: Our aim was to assess the performance of flow-diverter stents. The pre- and end-of-treatment angiographies are commonly compared. However, the arterial flow rate may change between acquisitions; therefore, a better understanding of its influence on the local intra-aneurysmal hemodynamics before and after flow-diverter stent use is required. MATERIALS AND METHODS: Twenty-five image-based aneurysm models extracted from 3D rotational angiograms were conditioned for computational fluid dynamics simulations. Pulsatile simulations were performed at different arterial flow rates, covering a wide possible range of physiologic flows among 1–5 mL/s. The effect of flow-diverter stents on intra-aneurysmal hemodynamics was numerically simulated with a porous medium model. Spatiotemporal-averaged intra-aneurysmal flow velocity and flow rate were calculated for each case to quantify the hemodynamics after treatment. The short-term flow-diverter stent performance was characterized by the relative velocity reduction inside the aneurysm. RESULTS: Spatiotemporal-averaged intra-aneurysmal flow velocity before and after flow-diverter stent use is linearly proportional to the mean arterial flow rate (minimum R2 > 0.983 of the linear regression models for untreated and stented models). Relative velocity reduction asymptotically decreases with increasing mean arterial flow rate. When the most probable range of arterial flow rate was considered (3–5 mL/s), instead of the wide possible flow range, the mean SD of relative velocity reduction was reduced from 3.6% to 0.48%. CONCLUSIONS: Both intra-aneurysmal aneurysm velocity and flow-diverter stent performance depend on the arterial flow rate. The performance could be considered independent of the arterial flow rates within the most probable range of physiologic flows.


  • Wall shear stress at the initiation site of cerebral aneurysms

    by A. J. Geers, H. G. Morales, I. Larrabide, C. Butakoff, P. Bijlenga, A. F. Frangi

    Hemodynamics are believed to play an important role in the initiation of cerebral aneurysms. In particular, studies have focused on wall shear stress (WSS), which is a key regulator of vascular biology and pathology. In line with the observation that aneurysms predominantly occur at regions of high WSS, such as bifurcation apices or outer walls of vascular bends, correlations have been found between the aneurysm initiation site and high WSS. The aim of our study was to analyze the WSS field at an aneurysm initiation site that was neither a bifurcation apex nor the outer wall of a vascular bend. Ten cases with aneurysms on the A1 segment of the anterior cerebral artery were analyzed and compared with ten controls. Aneurysms were virtually removed from the vascular models of the cases to mimic the pre-aneurysm geometry. Computational fluid dynamics (CFD) simulations were created to assess the magnitude, gradient, multidirectionality, and pulsatility of the WSS. To aid the inter-subject comparison of hemodynamic variables, we mapped the branch surfaces onto a two-dimensional parametric space. This approach made it possible to view the whole branch at once for qualitative evaluation. It also allowed us to empirically define a patch for quantitative analysis, which was consistent among subjects and encapsulated the aneurysm initiation sites in our dataset. To test the sensitivity of our results, CFD simulations were repeated with a second independent observer virtually removing the aneurysms and with a 20 % higher flow rate at the inlet. We found that branches harboring aneurysms were characterized by high WSS and high WSS gradients. Among all assessed variables, the aneurysm initiation site most consistently coincided with peaks of temporal variation in the WSS magnitude.


  • Open Access

    Patient-specific modelling of abdominal aortic aneurysms: The influence of wall thickness on predicted clinical outcomes

    by Noel Conlisk, Arjan J. Geers, Olivia M.B. McBride, David E. Newby, Peter R. Hoskins

    Rupture of abdominal aortic aneurysms (AAAs) is linked to aneurysm morphology. This study investigates the influence of patient-specific (PS) AAA wall thickness on predicted clinical outcomes. Eight patients under surveillance for AAAs were selected from the MA(3)RS clinical trial based on the complete absence of intraluminal thrombus. Two finite element (FE) models per patient were constructed; the first incorporated variable wall thickness from CT (PS_wall), and the second employed a 1.9mm uniform wall (Uni_wall). Mean PS wall thickness across all patients was 1.77±0.42mm. Peak wall stress (PWS) for PS_wall and Uni_wall models was 0.6761±0.3406N/mm(2) and 0.4905±0.0850N/mm(2), respectively. In 4 out of 8 patients the Uni_wall underestimated stress by as much as 55%; in the remaining cases it overestimated stress by up to 40%. Rupture risk more than doubled in 3 out of 8 patients when PS_wall was considered. Wall thickness influenced the location and magnitude of PWS as well as its correlation with curvature. Furthermore, the volume of the AAA under elevated stress increased significantly in AAAs with higher rupture risk indices. This highlights the sensitivity of standard rupture risk markers to the specific wall thickness strategy employed.


  • Accuracy and Reproducibility of Patient-Specific Hemodynamic Models of Stented Intracranial Aneurysms: Report on the Virtual Intracranial Stenting Challenge 2011

    by S. Cito, A. J. Geers, M. P. Arroyo, V. R. Palero, J. Pallarés, A. Vernet, J. Blasco, L. San Román, W. Fu, A. Qiao, et al.

    Validation studies are prerequisites for computational fluid dynamics (CFD) simulations to be accepted as part of clinical decision-making. This paper reports on the 2011 edition of the Virtual Intracranial Stenting Challenge. The challenge aimed to assess the reproducibility with which research groups can simulate the velocity field in an intracranial aneurysm, both untreated and treated with five different configurations of high-porosity stents. Particle imaging velocimetry (PIV) measurements were obtained to validate the untreated velocity field. Six participants, totaling three CFD solvers, were provided with surface meshes of the vascular geometry and the deployed stent geometries, and flow rate boundary conditions for all inlets and outlets. As output, they were invited to submit an abstract to the 8th International Interdisciplinary Cerebrovascular Symposium 2011 (ICS’11), outlining their methods and giving their interpretation of the performance of each stent configuration. After the challenge, all CFD solutions were collected and analyzed. To quantitatively analyze the data, we calculated the root-mean-square error (RMSE) over uniformly distributed nodes on a plane slicing the main flow jet along its axis and normalized it with the maximum velocity on the slice of the untreated case (NRMSE). Good agreement was found between CFD and PIV with a NRMSE of 7.28%. Excellent agreement was found between CFD solutions, both untreated and treated. The maximum difference between any two groups (along a line perpendicular to the main flow jet) was 4.0 mm/s, i.e. 4.1% of the maximum velocity of the untreated case, and the average NRMSE was 0.47% (range 0.28–1.03%). In conclusion, given geometry and flow rates, research groups can accurately simulate the velocity field inside an intracranial aneurysm—as assessed by comparison with in vitro measurements—and find excellent agreement on the hemodynamic effect of different stent configurations.


  • Approximating hemodynamics of cerebral aneurysms with steady flow simulations

    by A.J. Geers, I. Larrabide, H.G. Morales, A.F. Frangi