Kiyoshi Mabuchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kiyoshi Mabuchi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Kentaro Uchida
Department of Orthopaedic Surgery, Kitasato University School of Medicine, 1-15-1 Minami-ku, Kitasato, Sagamihara 252-0374, Kanagawa, Japan
4 shared publications - Rina Sakai
Department of Medical Engineering and Technology, Kitasato University School of Allied Health Sciences
2 shared publications - Gen Inoue
Department of Orthopaedic Surgery, Kitasato University School of Medicine, 1-15-1 Minami-ku, Kitasato, Sagamihara 252-0374, Kanagawa, Japan
1 shared publication Gongfa Chen
Institute of Health and Biomedical Innovation, Institute of Health and Biomedical Innovation, School
1 shared publicationHiroaki Minehara
Department of Orthpedic Surgery, School of Medicine, Kitasato University
1 shared publicationHiroko Iwashita
Department of Ophthalmology, School of Medicine, Toho University
1 shared publication
Latest Publications
- Open Access
- 31 October 2024
- Published by Japanese Society of Tribologists in Tribology Online
- Vol. 19 (6) , 486-489
Accuracy of Stanton’s Formula Used for the Data Processing of a Pendulum Friction Test
Pendulum friction-tester is specifically useful for experiments in biotribological field because that is good at the measure on circular sliding surfaces, like as synovial joints, joint prostheses, eye balls, or contact lenses. Stanton’s formula has been generally used for the data processing as the calculation of friction coefficient from the amplitude decay during a pendulum libration. Because Stanton used the balance of moment to analyze the pendulum motion, his analysis must inevitably include an approximation of sin θ as angle θ. However, the error in the formula has not been evaluated because the strict analysis was thought to be impossible. In the present study, the strict analysis was clarified by energy balance in a pendulum. As the result, error in Stanton’s formula was able to be evaluated.
- 31 October 2024
- Published by Japanese Society of Tribologists in Tribology Online
- Vol. 19 (6) , 486-489
Open AccessAccuracy of Stanton’s Formula Used for the Data Processing of a Pendulum Friction Test
Pendulum friction-tester is specifically useful for experiments in biotribological field because that is good at the measure on circular sliding surfaces, like as synovial joints, joint prostheses, eye balls, or contact lenses. Stanton’s formula has been generally used for the data processing as the calculation of friction coefficient from the amplitude decay during a pendulum libration. Because Stanton used the balance of moment to analyze the pendulum motion, his analysis must inevitably include an approximation of sin θ as angle θ. However, the error in the formula has not been evaluated because the strict analysis was thought to be impossible. In the present study, the strict analysis was clarified by energy balance in a pendulum. As the result, error in Stanton’s formula was able to be evaluated.
- Open Access
- 21 July 2014
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-6
Comparison of Internal Fixations for Distal Clavicular Fractures Based on Loading Tests and Finite Element Analyses
It is difficult to apply strong and stable internal fixation to a fracture of the distal end of the clavicle because it is unstable, the distal clavicle fragment is small, and the fractured region is near the acromioclavicular joint. In this study, to identify a superior internal fixation method for unstable distal clavicular fracture, we compared three types of internal fixation (tension band wiring, scorpion, and LCP clavicle hook plate). Firstly, loading tests were performed, in which fixations were evaluated using bending stiffness and torsional stiffness as indices, followed by finite element analysis to evaluate fixability using the stress and strain as indices. The bending and torsional stiffness were significantly higher in the artificial clavicles fixed with the two types of plate than in that fixed by tension band wiring (). No marked stress concentration on the clavicle was noted in the scorpion because the arm plate did not interfere with the acromioclavicular joint, suggesting that favorable shoulder joint function can be achieved. The stability of fixation with the LCP clavicle hook plate and the scorpion was similar, and plate fixations were stronger than fixation by tension band wiring.- 21 July 2014
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-6
Open AccessComparison of Internal Fixations for Distal Clavicular Fractures Based on Loading Tests and Finite Element Analyses
It is difficult to apply strong and stable internal fixation to a fracture of the distal end of the clavicle because it is unstable, the distal clavicle fragment is small, and the fractured region is near the acromioclavicular joint. In this study, to identify a superior internal fixation method for unstable distal clavicular fracture, we compared three types of internal fixation (tension band wiring, scorpion, and LCP clavicle hook plate). Firstly, loading tests were performed, in which fixations were evaluated using bending stiffness and torsional stiffness as indices, followed by finite element analysis to evaluate fixability using the stress and strain as indices. The bending and torsional stiffness were significantly higher in the artificial clavicles fixed with the two types of plate than in that fixed by tension band wiring (). No marked stress concentration on the clavicle was noted in the scorpion because the arm plate did not interfere with the acromioclavicular joint, suggesting that favorable shoulder joint function can be achieved. The stability of fixation with the LCP clavicle hook plate and the scorpion was similar, and plate fixations were stronger than fixation by tension band wiring. - 1 January 2014
- Published by Springer Nature
- p. 339-342
Response of a Femoral Bone to Stationary and Continuous Load from within Outward
- 1 January 2014
- Published by Springer Nature
- p. 339-342
Response of a Femoral Bone to Stationary and Continuous Load from within Outward
- Open Access
- 1 January 2011
- Published by Society of Biomechanisms Japan in Journal of the Society of Biomechanisms
- Vol. 35 (2) , 130-136
Prediction of the fixation conditions of murine fracture fixation plates
- 1 January 2011
- Published by Society of Biomechanisms Japan in Journal of the Society of Biomechanisms
- Vol. 35 (2) , 130-136
Open AccessPrediction of the fixation conditions of murine fracture fixation plates