Shane P. Prejean
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shane P. Prejean has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Mustafa Ahmed
University of Alabama at Birmingham Hospital, USA
4 shared publicationsAmi E. Iskandrian
Division of Cardiovascular Disease, Department of Medicine, University of Alabama at Birmingham, Birmingham, Alabama
3 shared publications- Fadi G. Hage
Division of Cardiovascular Disease, Department of Medicine, University of Alabama at Birmingham, Birmingham, USA
3 shared publications Gregory Von Mering
Division of Cardiovascular Disease, University of Alabama at Birmingham, Birmingham, AL, USA
3 shared publications- Charles W. Hoopes
Department of Cardiac Surgery Thomas Jefferson University Philadelphia Pennsylvania USA
2 shared publications - Hussein Abu Daya
Division of Cardiovascular Disease, Department of Medicine, University of Alabama at Birmingham, Birmingham, Alabama; Section of Cardiology, Birmingham Veteran s Affairs Medical Center, Birmingham, Alabama
2 shared publications
Latest Publications
- Open Access
- 15 June 2022
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (Supplement) , 119
P45: Extracorporeal Membrane Oxygenation as a Bridge to Transcatheter Aortic Valve Replacement in Patients with Cardiogenic Shock due to Critical Aortic Stenosis
- 15 June 2022
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (Supplement) , 119
Open AccessP45: Extracorporeal Membrane Oxygenation as a Bridge to Transcatheter Aortic Valve Replacement in Patients with Cardiogenic Shock due to Critical Aortic Stenosis
- 8 August 2021
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 33 (9) , E687-E693
An Updated Comparison of Conventional Coronary Angiography With Cardiac Magnetic Resonance Imaging to Diagnose the Origin and Proximal Course of Anomalous Coronary Arteries
Dr. Al-Mubarak and colleagues evaluate the accuracy of CCAs compared to CMR imaging in determining the site of origin and proximal course of ACAs.
- 8 August 2021
- Published by HMP Communications, LLC in Journal of Invasive Cardiology
- Vol. 33 (9) , E687-E693
An Updated Comparison of Conventional Coronary Angiography With Cardiac Magnetic Resonance Imaging to Diagnose the Origin and Proximal Course of Anomalous Coronary Arteries
Dr. Al-Mubarak and colleagues evaluate the accuracy of CCAs compared to CMR imaging in determining the site of origin and proximal course of ACAs.
- 1 June 2021
- Published by Elsevier in The American Journal of Cardiology
- Vol. 148, 124-129
Review of Published Cases of Syncope and Sudden Death in Patients With Severe Aortic Stenosis Documented by Electrocardiography
- 1 June 2021
- Published by Elsevier in The American Journal of Cardiology
- Vol. 148, 124-129
Review of Published Cases of Syncope and Sudden Death in Patients With Severe Aortic Stenosis Documented by Electrocardiography
- 25 February 2021
- Published by SAGE Publications in Journal for Vascular Ultrasound
- Vol. 45 (2) , 57-58
Distal Radial Artery Pseudoaneurysm Successfully Treated With Merit PreludeSYNC™ Compression Device
- 25 February 2021
- Published by SAGE Publications in Journal for Vascular Ultrasound
- Vol. 45 (2) , 57-58
Distal Radial Artery Pseudoaneurysm Successfully Treated With Merit PreludeSYNC™ Compression Device
- 22 February 2021
- Published by Wiley in Echocardiography
- Vol. 38 (3) , 493-499
Utility of transesophageal echocardiography to assess real time left atrial pressure changes and dynamic mitral regurgitation following placement of transseptal multistage venous cannula for systemic venous drainage and indirect left ventricular venting in venoarterial extracorporeal membrane oxygenation
A patient with heart failure due to nonischemic cardiomyopathy presented as a transfer to our institution following peripheral (femoral) venoarterial (VA) extracorporeal membrane oxygenation (ECMO) placement. With peripheral VA ECMO cannulation, the patient continued to have unstable ventricular tachyarrhythmias. Echocardiography demonstrated left ventricular (LV) dilation and severe mitral regurgitation (MR) with clinical and chest X‐ray evidence of pulmonary edema. To provide venous drainage and simultaneous decompression of the left atrium (LA) and thereby indirect LV venting, a single multistage venous cannula was placed across the inter‐atrial septum (IAS) using the previously described left atrial venoarterial (LA‐VA) ECMO cannulation technique. Two‐ and three‐dimensional (3D) transesophageal echocardiography (TEE) demonstrated utility in guiding cannula placement into the appropriate position and providing real time assessment of ventricular decompression and MR severity. There was subsequent improvement in pulmonary edema. This case is thought to be the first demonstration of real time resolution of pulmonary venous flow reversal in a patient undergoing LA‐VA ECMO cannulation. This demonstration offers important mechanistic insight into some of the potential benefits of such an approach.
- 22 February 2021
- Published by Wiley in Echocardiography
- Vol. 38 (3) , 493-499
Utility of transesophageal echocardiography to assess real time left atrial pressure changes and dynamic mitral regurgitation following placement of transseptal multistage venous cannula for systemic venous drainage and indirect left ventricular venting in venoarterial extracorporeal membrane oxygenation
A patient with heart failure due to nonischemic cardiomyopathy presented as a transfer to our institution following peripheral (femoral) venoarterial (VA) extracorporeal membrane oxygenation (ECMO) placement. With peripheral VA ECMO cannulation, the patient continued to have unstable ventricular tachyarrhythmias. Echocardiography demonstrated left ventricular (LV) dilation and severe mitral regurgitation (MR) with clinical and chest X‐ray evidence of pulmonary edema. To provide venous drainage and simultaneous decompression of the left atrium (LA) and thereby indirect LV venting, a single multistage venous cannula was placed across the inter‐atrial septum (IAS) using the previously described left atrial venoarterial (LA‐VA) ECMO cannulation technique. Two‐ and three‐dimensional (3D) transesophageal echocardiography (TEE) demonstrated utility in guiding cannula placement into the appropriate position and providing real time assessment of ventricular decompression and MR severity. There was subsequent improvement in pulmonary edema. This case is thought to be the first demonstration of real time resolution of pulmonary venous flow reversal in a patient undergoing LA‐VA ECMO cannulation. This demonstration offers important mechanistic insight into some of the potential benefits of such an approach.
- 2 October 2020
- Published by Wiley in Echocardiography
- Vol. 37 (11) , 1860-1863
Utility of three‐dimensional transesophageal echocardiography to guide transseptal positioning of a single multistage venous cannula to provide both venous drainage and indirect left ventricular venting in veno‐arterial extracorporeal membrane oxygenation
A patient with heart failure due to dilated ischemic cardiomyopathy presented in cardiogenic shock for institution of veno‐arterial extracorporeal membrane oxygenation as a bridge to cardiac transplantation. To provide adequate venous drainage and simultaneous decompression of the left atrium (indirect left ventricular venting), a single venous cannula was placed across the interatrial septum so that the distal orifice and side ports were located within the left atrium and the proximal set of side ports were positioned at the cavoatrial junction. Three‐dimensional transesophageal echocardiography demonstrated utility in guiding cannula placement and appropriate positioning within the left atrium.
- 2 October 2020
- Published by Wiley in Echocardiography
- Vol. 37 (11) , 1860-1863
Utility of three‐dimensional transesophageal echocardiography to guide transseptal positioning of a single multistage venous cannula to provide both venous drainage and indirect left ventricular venting in veno‐arterial extracorporeal membrane oxygenation
A patient with heart failure due to dilated ischemic cardiomyopathy presented in cardiogenic shock for institution of veno‐arterial extracorporeal membrane oxygenation as a bridge to cardiac transplantation. To provide adequate venous drainage and simultaneous decompression of the left atrium (indirect left ventricular venting), a single venous cannula was placed across the interatrial septum so that the distal orifice and side ports were located within the left atrium and the proximal set of side ports were positioned at the cavoatrial junction. Three‐dimensional transesophageal echocardiography demonstrated utility in guiding cannula placement and appropriate positioning within the left atrium.
- 12 June 2020
- Published by Wiley in Echocardiography
- Vol. 37 (7) , 1088-1090
Fusion imaging during balloon mitral valvulopasty: First experience
The EchoNavigator (EchoNav, Philips, The Netherlands) is a tool that fuses live X‐ray with three‐dimensional (3D) transesophageal echocardiogram (TEE) images allowing for enhanced precision and accuracy during interventional cardiac procedures. We present the first case of EchoNav utilization during balloon mitral valvuloplasty using the newest version (EchoNav 3.0.2). The benefits of the EchoNav application include improved procedural precision and safety due to improved demonstration of the relationship between the interventional equipment and neighboring cardiac structures.
- 12 June 2020
- Published by Wiley in Echocardiography
- Vol. 37 (7) , 1088-1090
Fusion imaging during balloon mitral valvulopasty: First experience
The EchoNavigator (EchoNav, Philips, The Netherlands) is a tool that fuses live X‐ray with three‐dimensional (3D) transesophageal echocardiogram (TEE) images allowing for enhanced precision and accuracy during interventional cardiac procedures. We present the first case of EchoNav utilization during balloon mitral valvuloplasty using the newest version (EchoNav 3.0.2). The benefits of the EchoNav application include improved procedural precision and safety due to improved demonstration of the relationship between the interventional equipment and neighboring cardiac structures.
- 23 November 2019
- Published by Wiley in Echocardiography
- Vol. 36 (11) , 2086-2089
Use of echocardiography as an essential tool for targeted transcatheter biopsy of cardiac masses
Echocardiography has emerged as an essential tool to guide targeted, transcatheter biopsy of cardiac masses. Options for imaging include transthoracic or transesophageal echocardiography and intracardiac echocardiography, with appropriate use being dictated by specific patient characteristics and institutional experience. The authors present a case of three‐dimensional (3‐D) transesophageal echocardiography‐guided transcatheter biopsy of a right ventricular mass and review the current use of echocardiography to guide these procedures.
- 23 November 2019
- Published by Wiley in Echocardiography
- Vol. 36 (11) , 2086-2089
Use of echocardiography as an essential tool for targeted transcatheter biopsy of cardiac masses
Echocardiography has emerged as an essential tool to guide targeted, transcatheter biopsy of cardiac masses. Options for imaging include transthoracic or transesophageal echocardiography and intracardiac echocardiography, with appropriate use being dictated by specific patient characteristics and institutional experience. The authors present a case of three‐dimensional (3‐D) transesophageal echocardiography‐guided transcatheter biopsy of a right ventricular mass and review the current use of echocardiography to guide these procedures.
- 15 April 2019
- Published by SAGE Publications in Journal for Vascular Ultrasound
- Vol. 43 (2) , 81-85
Successful Treatment of Pseudoaneurysm Following Left Distal Transradial Cardiac Catheterization With Compression Device
Distal transradial artery access has emerged as a promising new method of access for coronary and endovascular procedures. With the increasing use of distal transradial artery access, operators will need to gain experience in the management of complications in the anatomical snuffbox. We review the rationale behind distal transradial access and summarize rate of vascular complications, based on the review of the literature. We then report a case of pseudoaneurysm in the distal left radial artery occurring 20 hours after cardiac catheterization likely precipitated by intravenous heparin and dual antiplatelet therapy with aspirin and prasugrel received during a second procedure. A modified compression technique with the TR band® (Terumo Medical Corporation, Tokyo, Japan) was used in which the rigid, plastic insert was removed prior to application to facilitate improved apposition of the band on the dorsum of the hand, and waveforms from continuous pulse oximetry were used to guide “patent compression.” Thrombosis of the pseudoaneurysm was achieved in 12 hours, and no further intervention was required.
- 15 April 2019
- Published by SAGE Publications in Journal for Vascular Ultrasound
- Vol. 43 (2) , 81-85
Successful Treatment of Pseudoaneurysm Following Left Distal Transradial Cardiac Catheterization With Compression Device
Distal transradial artery access has emerged as a promising new method of access for coronary and endovascular procedures. With the increasing use of distal transradial artery access, operators will need to gain experience in the management of complications in the anatomical snuffbox. We review the rationale behind distal transradial access and summarize rate of vascular complications, based on the review of the literature. We then report a case of pseudoaneurysm in the distal left radial artery occurring 20 hours after cardiac catheterization likely precipitated by intravenous heparin and dual antiplatelet therapy with aspirin and prasugrel received during a second procedure. A modified compression technique with the TR band® (Terumo Medical Corporation, Tokyo, Japan) was used in which the rigid, plastic insert was removed prior to application to facilitate improved apposition of the band on the dorsum of the hand, and waveforms from continuous pulse oximetry were used to guide “patent compression.” Thrombosis of the pseudoaneurysm was achieved in 12 hours, and no further intervention was required.