Charles W. Hoopes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Charles W. Hoopes has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Erik J. Orozco-Hernandez
Division of Cardiothoracic Surgery, Department of Cardiac Surgery, University of Alabama at Birmingham, Birmingham, AL 35294, USA
4 shared publications - Shane P. Prejean
Division of Cardiovascular Disease, Department of Medicine, University of Alabama at Birmingham, Birmingham, Alabama
2 shared publications - Ahmed Mustafa
Affiliation Department of Biological Sciences, Purdue University Fort Wayne, Fort Wayne, Indiana, United States of America
1 shared publication Alex Abdullayev
Cardiothoracic Surgery, University of Alabama at Birmingham, Birmingham, AL, United States
1 shared publicationAndrew Lenneman
Department of Medicine Division of Cardiovascular Disease University of Alabama at Birmingham School of Medicine Birmingham AL USA
1 shared publication- Benjamin Smood
University of Pennsylvania
1 shared publication
Latest Publications
- Open Access
- 9 April 2026
- Published by Wiley in Clinical Transplantation
- Vol. 40 (4) , e70505
Utility of Right Ventricular Mass Ratios in Recipients With Pulmonary Hypertension: A United Network for Organ‐Sharing Database Analysis
Purpose: There is a lack of data reviewing the role of predicted cardiac mass ratio (PCMR) in transplant recipients with pulmonary hypertension (PH). In particular, the right ventricular (RV) mass ratio (RVMR) is a component of PCMR not yet studied separately for this purpose. We aimed to review the relationship of PCMR and RVMR with PH in terms of post‐transplant overall survival. Methods: The United Network for Organ‐Sharing (UNOS) database was queried for primary heart transplant (HTx) patients from 2004 to 2023. Predicted RVMR was calculated for donors and recipients. A parsimonious multivariable model Cox model was formed for risk adjustment. Covariates with statistically significant relationships to the outcomes were further evaluated with tensor product spline models. Results: A total of 37 904 patients were identified. After risk adjustment, diastolic pulmonary artery pressure (dPAP) was protective (HR 0.993 [0.989–0.997], p = 0.001), whereas increasing systolic pulmonary artery pressures (sPAPs) (HR 1.007 [1.005–1.009], p < 0.001) and diastolic pulmonary gradient (DPG) (HR 1.011 [1.007–1.015], p < 0.001) were associated with increased overall mortality. Increasing RV mass ratio (RVMR) was protective (OR 0.663 [0.589–0.747], p < 0.001)). This was appreciated in a restricted cubic spline analysis as a nonlinear relation was evident with any RVMR less than 1 ( p < 0.001). Subsequent tensor product spline models evaluating the complex relationship between RVMR and pulmonary pressures demonstrated increasing relative hazards in patients with PH and smaller RVMR ( p < 0.001). Conclusion: In HTx patients with PH, RVMR ≥ 1 is significantly associated with a reduced hazard of overall mortality. This indicates RV undersizing may be harmful in the population.
- 9 April 2026
- Published by Wiley in Clinical Transplantation
- Vol. 40 (4) , e70505
Open AccessUtility of Right Ventricular Mass Ratios in Recipients With Pulmonary Hypertension: A United Network for Organ‐Sharing Database Analysis
Purpose: There is a lack of data reviewing the role of predicted cardiac mass ratio (PCMR) in transplant recipients with pulmonary hypertension (PH). In particular, the right ventricular (RV) mass ratio (RVMR) is a component of PCMR not yet studied separately for this purpose. We aimed to review the relationship of PCMR and RVMR with PH in terms of post‐transplant overall survival. Methods: The United Network for Organ‐Sharing (UNOS) database was queried for primary heart transplant (HTx) patients from 2004 to 2023. Predicted RVMR was calculated for donors and recipients. A parsimonious multivariable model Cox model was formed for risk adjustment. Covariates with statistically significant relationships to the outcomes were further evaluated with tensor product spline models. Results: A total of 37 904 patients were identified. After risk adjustment, diastolic pulmonary artery pressure (dPAP) was protective (HR 0.993 [0.989–0.997], p = 0.001), whereas increasing systolic pulmonary artery pressures (sPAPs) (HR 1.007 [1.005–1.009], p < 0.001) and diastolic pulmonary gradient (DPG) (HR 1.011 [1.007–1.015], p < 0.001) were associated with increased overall mortality. Increasing RV mass ratio (RVMR) was protective (OR 0.663 [0.589–0.747], p < 0.001)). This was appreciated in a restricted cubic spline analysis as a nonlinear relation was evident with any RVMR less than 1 ( p < 0.001). Subsequent tensor product spline models evaluating the complex relationship between RVMR and pulmonary pressures demonstrated increasing relative hazards in patients with PH and smaller RVMR ( p < 0.001). Conclusion: In HTx patients with PH, RVMR ≥ 1 is significantly associated with a reduced hazard of overall mortality. This indicates RV undersizing may be harmful in the population.
- Open Access
- 15 June 2022
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (Supplement) , 119
P45: Extracorporeal Membrane Oxygenation as a Bridge to Transcatheter Aortic Valve Replacement in Patients with Cardiogenic Shock due to Critical Aortic Stenosis
- 15 June 2022
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (Supplement) , 119
Open AccessP45: Extracorporeal Membrane Oxygenation as a Bridge to Transcatheter Aortic Valve Replacement in Patients with Cardiogenic Shock due to Critical Aortic Stenosis
- 22 December 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (10) , e172
Pulmonary Transplant After More Than 1 Year of Continuous Ambulatory Extracorporeal Support
While extracorporeal support of patients awaiting pulmonary transplantation is now well-established, extracorporeal membrane oxygenation (ECMO) remains a nondurable technology deployed for short-term support or recovery in patients with progressive disease. Here, we describe an anecdotal experience with pulmonary transplant after more than 1 year of continuous veno-venous ECMO support. The case highlights several issues relevant to the increasing use of bridging technologies: (1) the potential impact of extracorporeal circulation on immune sensitization, (2) the safety and questionable need for anticoagulation in long-term ambulatory veno-venous extracorporeal support, and (3) the increasing durability of contemporary ECMO support technologies.
- 22 December 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (10) , e172
Pulmonary Transplant After More Than 1 Year of Continuous Ambulatory Extracorporeal Support
While extracorporeal support of patients awaiting pulmonary transplantation is now well-established, extracorporeal membrane oxygenation (ECMO) remains a nondurable technology deployed for short-term support or recovery in patients with progressive disease. Here, we describe an anecdotal experience with pulmonary transplant after more than 1 year of continuous veno-venous ECMO support. The case highlights several issues relevant to the increasing use of bridging technologies: (1) the potential impact of extracorporeal circulation on immune sensitization, (2) the safety and questionable need for anticoagulation in long-term ambulatory veno-venous extracorporeal support, and (3) the increasing durability of contemporary ECMO support technologies.
- Open Access
- 19 June 2021
- Published by Elsevier in JTCVS Techniques
- Vol. 9, 199-201
Ambulatory femoral venovenous extracorporeal membrane oxygenation with a dual-lumen cannula
- 19 June 2021
- Published by Elsevier in JTCVS Techniques
- Vol. 9, 199-201
Open AccessAmbulatory femoral venovenous extracorporeal membrane oxygenation with a dual-lumen cannula
- Open Access
- 1 March 2021
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 9 (6) , 522
Pulmonary vasodilator use in continuous-flow left ventricular assist device management
Pulmonary hypertension (PH) due to left heart disease is the most common etiology for PH. PH in patients with heart failure with reduced fraction (HFrEF) is associated with reduced functional capacity and increased mortality. PH-HFrEF can be isolated post-capillary or combined pre- and post-capillary PH. Chronic elevation of left-sided filling pressures may lead to reverse remodeling of the pulmonary vasculature with development of precapillary component of PH. Untreated PH in patients with HFrEF results in predominant right heart failure (RHF) with irreversible end-organ dysfunction. Management of PH-HFrEF includes diuretics, vasodilators like angiotensin-converting enzyme inhibitors or angiotensin-receptor blockers or angiotensin-receptor blocker-neprilysin inhibitors, hydralazine and nitrates. There is no role for pulmonary vasodilator use in patients with PH-HFrEF due to increased mortality in clinical trials. In patients with end-stage HFrEF and fixed PH unresponsive to vasodilator challenge, implantation of continuous-flow left ventricular assist device (cfLVAD) results in marked improvement in pulmonary artery pressures within 6 months due to left ventricular (LV) mechanical unloading. The role of pulmonary vasodilators in management of precapillary component of PH after cfLVAD is not well-defined. The purpose of this review is to discuss the pharmacologic management of PH after cfLVAD implantation.
- 1 March 2021
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 9 (6) , 522
Open AccessPulmonary vasodilator use in continuous-flow left ventricular assist device management
Pulmonary hypertension (PH) due to left heart disease is the most common etiology for PH. PH in patients with heart failure with reduced fraction (HFrEF) is associated with reduced functional capacity and increased mortality. PH-HFrEF can be isolated post-capillary or combined pre- and post-capillary PH. Chronic elevation of left-sided filling pressures may lead to reverse remodeling of the pulmonary vasculature with development of precapillary component of PH. Untreated PH in patients with HFrEF results in predominant right heart failure (RHF) with irreversible end-organ dysfunction. Management of PH-HFrEF includes diuretics, vasodilators like angiotensin-converting enzyme inhibitors or angiotensin-receptor blockers or angiotensin-receptor blocker-neprilysin inhibitors, hydralazine and nitrates. There is no role for pulmonary vasodilator use in patients with PH-HFrEF due to increased mortality in clinical trials. In patients with end-stage HFrEF and fixed PH unresponsive to vasodilator challenge, implantation of continuous-flow left ventricular assist device (cfLVAD) results in marked improvement in pulmonary artery pressures within 6 months due to left ventricular (LV) mechanical unloading. The role of pulmonary vasodilators in management of precapillary component of PH after cfLVAD is not well-defined. The purpose of this review is to discuss the pharmacologic management of PH after cfLVAD implantation.
- 22 February 2021
- Published by Wiley in Echocardiography
- Vol. 38 (3) , 493-499
Utility of transesophageal echocardiography to assess real time left atrial pressure changes and dynamic mitral regurgitation following placement of transseptal multistage venous cannula for systemic venous drainage and indirect left ventricular venting in venoarterial extracorporeal membrane oxygenation
A patient with heart failure due to nonischemic cardiomyopathy presented as a transfer to our institution following peripheral (femoral) venoarterial (VA) extracorporeal membrane oxygenation (ECMO) placement. With peripheral VA ECMO cannulation, the patient continued to have unstable ventricular tachyarrhythmias. Echocardiography demonstrated left ventricular (LV) dilation and severe mitral regurgitation (MR) with clinical and chest X‐ray evidence of pulmonary edema. To provide venous drainage and simultaneous decompression of the left atrium (LA) and thereby indirect LV venting, a single multistage venous cannula was placed across the inter‐atrial septum (IAS) using the previously described left atrial venoarterial (LA‐VA) ECMO cannulation technique. Two‐ and three‐dimensional (3D) transesophageal echocardiography (TEE) demonstrated utility in guiding cannula placement into the appropriate position and providing real time assessment of ventricular decompression and MR severity. There was subsequent improvement in pulmonary edema. This case is thought to be the first demonstration of real time resolution of pulmonary venous flow reversal in a patient undergoing LA‐VA ECMO cannulation. This demonstration offers important mechanistic insight into some of the potential benefits of such an approach.
- 22 February 2021
- Published by Wiley in Echocardiography
- Vol. 38 (3) , 493-499
Utility of transesophageal echocardiography to assess real time left atrial pressure changes and dynamic mitral regurgitation following placement of transseptal multistage venous cannula for systemic venous drainage and indirect left ventricular venting in venoarterial extracorporeal membrane oxygenation
A patient with heart failure due to nonischemic cardiomyopathy presented as a transfer to our institution following peripheral (femoral) venoarterial (VA) extracorporeal membrane oxygenation (ECMO) placement. With peripheral VA ECMO cannulation, the patient continued to have unstable ventricular tachyarrhythmias. Echocardiography demonstrated left ventricular (LV) dilation and severe mitral regurgitation (MR) with clinical and chest X‐ray evidence of pulmonary edema. To provide venous drainage and simultaneous decompression of the left atrium (LA) and thereby indirect LV venting, a single multistage venous cannula was placed across the inter‐atrial septum (IAS) using the previously described left atrial venoarterial (LA‐VA) ECMO cannulation technique. Two‐ and three‐dimensional (3D) transesophageal echocardiography (TEE) demonstrated utility in guiding cannula placement into the appropriate position and providing real time assessment of ventricular decompression and MR severity. There was subsequent improvement in pulmonary edema. This case is thought to be the first demonstration of real time resolution of pulmonary venous flow reversal in a patient undergoing LA‐VA ECMO cannulation. This demonstration offers important mechanistic insight into some of the potential benefits of such an approach.
- Open Access
- 13 August 2020
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 35 (10) , 2825-2828
Pedicle flap coverage for infected ventricular assist device augmented with dissolving antibiotic beads: Creation of an antibacterial pocket
Infectious complications following left ventricular assist device implantation can carry significant morbidity and mortality. The main tenet of treatment is source control which entails local wound care, intravenous antimicrobial therapy, surgical debridement, and at times, soft tissue flap coverage. The mode of therapy depends on the severity, etiology, and location of infection as well as the clinical status of the patient. We describe a case of a 46‐year‐old male who underwent left ventricular assist device placement complicated by pump thrombosis, recurrent infection, and hardware exposure who was successfully treated with a novel method of staged, soft tissue reconstruction.
- 13 August 2020
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 35 (10) , 2825-2828
Open AccessPedicle flap coverage for infected ventricular assist device augmented with dissolving antibiotic beads: Creation of an antibacterial pocket
Infectious complications following left ventricular assist device implantation can carry significant morbidity and mortality. The main tenet of treatment is source control which entails local wound care, intravenous antimicrobial therapy, surgical debridement, and at times, soft tissue flap coverage. The mode of therapy depends on the severity, etiology, and location of infection as well as the clinical status of the patient. We describe a case of a 46‐year‐old male who underwent left ventricular assist device placement complicated by pump thrombosis, recurrent infection, and hardware exposure who was successfully treated with a novel method of staged, soft tissue reconstruction.
- 1 April 2019
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 38 (4) , 456-465
Evaluation of flow-modulation approaches in ventricular assist devices using an in-vitro endothelial cell culture model
- 1 April 2019
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 38 (4) , 456-465
Evaluation of flow-modulation approaches in ventricular assist devices using an in-vitro endothelial cell culture model