Arthur Furtado de Mendonça
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Arthur Furtado de Mendonça has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Ayman Ellakwa
School of Dentistry, The University of Sydney, Westmead NSW 2145, Australia
1 shared publication Cresus Vinicius Depes de Gouvêa
Department of Prosthodontics, Fluminense Federal University, Niterói, Brazil
1 shared publicationDarren Littlefair
University of Manchester (Formerly UMIST), Manchester, UK
1 shared publicationGeorge Shelby White
Department of Prosthodontics, Columbia University College of Dental Medicine, New York, NY, USA
1 shared publicationGeorges Sara
Department of Prosthodontics, Columbia University College of Dental Medicine, New York, NY, USA
1 shared publication- Grace Mendonca De Souza
Department of Restorative Dentistry University at Buffalo School of Dental Medicine Buffalo New York USA
1 shared publication
Latest Publications
- 18 August 2018
- Published by Wiley in Journal of Prosthodontics
- Vol. 28 (2) , E587-E594
Microstructural and Mechanical Characterization of CAD/CAM Materials for Monolithic Dental Restorations
Purpose: To determine and compare the microstructure, flexural strength, flexural modulus, fracture strength, and microhardness of four types of computer‐aided design/computer‐aided manufacturing (CAD/CAM) materials for monolithic dental restorations.Materials and Methods: A lithium disilicate (LD; IPS e.max CAD), a zirconia‐reinforced lithium silicate (ZLS; VITA Suprinity), a hybrid high‐performance polymer (HPP) composite resin (GC Cerasmart), and a hybrid polymer‐infiltrated ceramic network (PICN) material (VITA Enamic) were used to manufacture monolithic ceramic posterior crowns (n = 10) that were adhesively cemented on resin‐based composite dies and loaded until fracture. In addition, 40 rectangular bars (n = 10) were milled and polished for three‐point flexural strength testing. Microhardness (Vickers indentation), as well as quantitative (energy dispersive spectroscopy) and qualitative (scanning electron microscopy) structural analysis were conducted on fracture surfaces. Data were analyzed by one‐way ANOVA and Tukey HSD post‐hoc test (p = 0.05).Results: Mechanical testing results showed that the material type has a significant effect on the fracture strength (p < 0.0001) of the monolithic crowns with ZLS and LD presenting significantly higher fracture strength than the PICN and HPP hybrid materials. LD showed the highest flexural strength (p < 0.0001) followed by ZLS, HPP, and PICN, respectively. The lowest flexural modulus and hardness were presented by HPP whereas ZLS had the highest flexural modulus and hardness. The LD presented the highest modulus of resilience and the PICN the lowest.Conclusions: All CAD/CAM crown materials exhibited high values of fracture and flexural resistance, making them suitable materials for posterior full‐crown restorations. Glass‐ceramics suffered more from catastrophic and nonreparable fracture patterns, whereas minimal chipping and type II fracture patterns were more common in hybrid materials. The combination of more flexibility, less stiffness, and increased softness with satisfactory flexural and fracture strength values observed in PICN and HPP makes these two hybrid materials suitable choices for chairside monolithic crown fabrication.
- 18 August 2018
- Published by Wiley in Journal of Prosthodontics
- Vol. 28 (2) , E587-E594
Microstructural and Mechanical Characterization of CAD/CAM Materials for Monolithic Dental Restorations
Purpose: To determine and compare the microstructure, flexural strength, flexural modulus, fracture strength, and microhardness of four types of computer‐aided design/computer‐aided manufacturing (CAD/CAM) materials for monolithic dental restorations.Materials and Methods: A lithium disilicate (LD; IPS e.max CAD), a zirconia‐reinforced lithium silicate (ZLS; VITA Suprinity), a hybrid high‐performance polymer (HPP) composite resin (GC Cerasmart), and a hybrid polymer‐infiltrated ceramic network (PICN) material (VITA Enamic) were used to manufacture monolithic ceramic posterior crowns (n = 10) that were adhesively cemented on resin‐based composite dies and loaded until fracture. In addition, 40 rectangular bars (n = 10) were milled and polished for three‐point flexural strength testing. Microhardness (Vickers indentation), as well as quantitative (energy dispersive spectroscopy) and qualitative (scanning electron microscopy) structural analysis were conducted on fracture surfaces. Data were analyzed by one‐way ANOVA and Tukey HSD post‐hoc test (p = 0.05).Results: Mechanical testing results showed that the material type has a significant effect on the fracture strength (p < 0.0001) of the monolithic crowns with ZLS and LD presenting significantly higher fracture strength than the PICN and HPP hybrid materials. LD showed the highest flexural strength (p < 0.0001) followed by ZLS, HPP, and PICN, respectively. The lowest flexural modulus and hardness were presented by HPP whereas ZLS had the highest flexural modulus and hardness. The LD presented the highest modulus of resilience and the PICN the lowest.Conclusions: All CAD/CAM crown materials exhibited high values of fracture and flexural resistance, making them suitable materials for posterior full‐crown restorations. Glass‐ceramics suffered more from catastrophic and nonreparable fracture patterns, whereas minimal chipping and type II fracture patterns were more common in hybrid materials. The combination of more flexibility, less stiffness, and increased softness with satisfactory flexural and fracture strength values observed in PICN and HPP makes these two hybrid materials suitable choices for chairside monolithic crown fabrication.
- Open Access
- 16 November 2016
- Published by Wiley in Case Reports in Dentistry
- Vol. 2016, 1-5
Total CAD/CAM Supported Method for Manufacturing Removable Complete Dentures
The incorporation of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture fabrication brings about several advantages to the fabrication process, providing better predictability of the desired outcomes and high accuracy of denture fit, mainly because the milling of prepolymerized acrylic resin eliminates the shrinkage of the acrylic base. Also, there is a decrease in the porosity when compared to a conventionally processed denture, and consequently there is a decrease in the retention ofCandida albicanson the denture base. The presented workflow for complete denture fabrication presents a totally wax-free manufacturing process, combining rapid prototyping (RP) and rapid milling. With the presented technique, the maxillomandibular relation (MMR) and the ideal setup of the tooth arrangement are developed by using occlusion rims and trial setup made with RP. For the definitive final denture, the denture base and the basal surfaces of the conventional denture teeth were milled according to the individual clinical situation. Posteriorly, the teeth were adapted and bonded into the milled sockets of the milled base.
- 16 November 2016
- Published by Wiley in Case Reports in Dentistry
- Vol. 2016, 1-5
Open AccessTotal CAD/CAM Supported Method for Manufacturing Removable Complete Dentures
The incorporation of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture fabrication brings about several advantages to the fabrication process, providing better predictability of the desired outcomes and high accuracy of denture fit, mainly because the milling of prepolymerized acrylic resin eliminates the shrinkage of the acrylic base. Also, there is a decrease in the porosity when compared to a conventionally processed denture, and consequently there is a decrease in the retention ofCandida albicanson the denture base. The presented workflow for complete denture fabrication presents a totally wax-free manufacturing process, combining rapid prototyping (RP) and rapid milling. With the presented technique, the maxillomandibular relation (MMR) and the ideal setup of the tooth arrangement are developed by using occlusion rims and trial setup made with RP. For the definitive final denture, the denture base and the basal surfaces of the conventional denture teeth were milled according to the individual clinical situation. Posteriorly, the teeth were adapted and bonded into the milled sockets of the milled base.
- Top Cited Papers
- 12 March 2014
- Published by Wiley in Clinical Oral Implants Research
- Vol. 26 (4) , 407-412
Ridge alterations following grafting of fresh extraction sockets in man. A randomized clinical trial
Objective: To evaluate dimensional alterations of the alveolar ridge that occurred following tooth extraction at sites grafted with Bio‐Oss® Collagen.Material and methods: Twenty‐eight subjects with maxillary incisors, canines, and premolars scheduled for extraction were included. The tooth was carefully removed. The patients were randomly assigned to a test or a control group. In the test group patients, Bio‐Oss® Collagen was placed in the fresh extraction socket while in the controls no grafting was performed.Radiographic examination (cone beam computed tomograms, CBCT) was performed immediately after tooth extraction and socket treatment. Four months later, a new CBCT was obtained. In the radiographs, (i) the distance (mm) between base of the alveolar process (apex) and the buccal and palatal crests was determined, (ii) the outer profile of alveolar process of the experimental sites was outlined, and the cross section of the area (mm2) determined.Results: After 4 months of healing, the buccal and to a less extent also the palatal bone plate had become markedly reduced in height. The placement of a biomaterial in the socket failed to prevent resorption of the buccal and palatal bone walls. The cross‐sectional area of the control ridge was reduced about 25% and of the test ridge with 3%.Conclusion: The placement of a xenograft in fresh extraction sockets markedly counteracted the reduction in the hard tissue component of the edentulous sites.
- 12 March 2014
- Published by Wiley in Clinical Oral Implants Research
- Vol. 26 (4) , 407-412
Top Cited PapersRidge alterations following grafting of fresh extraction sockets in man. A randomized clinical trial
Objective: To evaluate dimensional alterations of the alveolar ridge that occurred following tooth extraction at sites grafted with Bio‐Oss® Collagen.Material and methods: Twenty‐eight subjects with maxillary incisors, canines, and premolars scheduled for extraction were included. The tooth was carefully removed. The patients were randomly assigned to a test or a control group. In the test group patients, Bio‐Oss® Collagen was placed in the fresh extraction socket while in the controls no grafting was performed.Radiographic examination (cone beam computed tomograms, CBCT) was performed immediately after tooth extraction and socket treatment. Four months later, a new CBCT was obtained. In the radiographs, (i) the distance (mm) between base of the alveolar process (apex) and the buccal and palatal crests was determined, (ii) the outer profile of alveolar process of the experimental sites was outlined, and the cross section of the area (mm2) determined.Results: After 4 months of healing, the buccal and to a less extent also the palatal bone plate had become markedly reduced in height. The placement of a biomaterial in the socket failed to prevent resorption of the buccal and palatal bone walls. The cross‐sectional area of the control ridge was reduced about 25% and of the test ridge with 3%.Conclusion: The placement of a xenograft in fresh extraction sockets markedly counteracted the reduction in the hard tissue component of the edentulous sites.