Teuku Husaini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Teuku Husaini has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Edy Herianto Majlan
Universiti Kebangsaan Malaysia
8 shared publications - Masli Irwan Rosli
Department of Chemical and Process Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, UKM, Bangi, Malaysia
5 shared publications Edy Herianto Majlan
4 shared publications- Mohd Shahbudin Masdar
Fuel Cell Institute, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia
4 shared publications Abu Bakar Sulong
3 shared publications- Abu Bakar Sulong
Universiti Kebangsaan Malaysia
3 shared publications
Latest Publications
- 16 June 2026
- Published by Elsevier in Chemical Engineering Research and Design
- Vol. 231, 438-448
A wavy-parallel flow field channel for a bipolar plate of a lightweight metallic proton exchange membrane fuel cell
- 16 June 2026
- Published by Elsevier in Chemical Engineering Research and Design
- Vol. 231, 438-448
A wavy-parallel flow field channel for a bipolar plate of a lightweight metallic proton exchange membrane fuel cell
- Open Access
- 1 January 2026
- Published by Wiley in International Journal of Chemical Engineering
- Vol. 2026 (1) , 9945399
Impact of Substrate Type and Membrane Scaling on Catalyst Transfer Efficiency in PEM Water Electrolyzers via the Decal Method
Catalyst‐coated membranes (CCMs) were fabricated using the decal transfer method to enhance catalyst transfer efficiency, performance, and stability in polymer electrolyte membrane water electrolyzers (PEMWEs). Nafion 117 and Nafion 212 membranes with active 5, 25, and 36 cm 2 areas were used, incorporating IrO 2 (anode) and Pt/C (cathode) catalysts. Catalyst inks were sprayed onto PTFE sheet, Kapton film, and Teflon‐coated fiberglass substrates, followed by hot‐pressing at 130°C and 700 psi for 5 min. A thin Nafion ionomer layer facilitated efficient catalyst transfer. Among the substrates, Teflon‐coated fiberglass achieved the highest transfer efficiency (> 95%) and uniform catalyst distribution. At 60°C and 2.0 V, the 5 cm 2 Nafion 212 and Nafion 117 CCMs delivered maximum peak current densities of 1791 and 1497 mA/cm 2 , respectively. While Nafion 212 showed higher initial performance due to its lower thickness and resistance, Nafion 117 demonstrated superior durability during 48‐h stability testing, particularly at larger membrane sizes. These results underscore the potential of the decal method for scalable CCM fabrication and highlight the importance of membrane thickness and substrate selection in developing high‐performance, durable PEMWE systems for hydrogen production.
- 1 January 2026
- Published by Wiley in International Journal of Chemical Engineering
- Vol. 2026 (1) , 9945399
Open AccessImpact of Substrate Type and Membrane Scaling on Catalyst Transfer Efficiency in PEM Water Electrolyzers via the Decal Method
Catalyst‐coated membranes (CCMs) were fabricated using the decal transfer method to enhance catalyst transfer efficiency, performance, and stability in polymer electrolyte membrane water electrolyzers (PEMWEs). Nafion 117 and Nafion 212 membranes with active 5, 25, and 36 cm 2 areas were used, incorporating IrO 2 (anode) and Pt/C (cathode) catalysts. Catalyst inks were sprayed onto PTFE sheet, Kapton film, and Teflon‐coated fiberglass substrates, followed by hot‐pressing at 130°C and 700 psi for 5 min. A thin Nafion ionomer layer facilitated efficient catalyst transfer. Among the substrates, Teflon‐coated fiberglass achieved the highest transfer efficiency (> 95%) and uniform catalyst distribution. At 60°C and 2.0 V, the 5 cm 2 Nafion 212 and Nafion 117 CCMs delivered maximum peak current densities of 1791 and 1497 mA/cm 2 , respectively. While Nafion 212 showed higher initial performance due to its lower thickness and resistance, Nafion 117 demonstrated superior durability during 48‐h stability testing, particularly at larger membrane sizes. These results underscore the potential of the decal method for scalable CCM fabrication and highlight the importance of membrane thickness and substrate selection in developing high‐performance, durable PEMWE systems for hydrogen production.
- 7 June 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 144, 336-358
A direct seawater electrolysis (DSWEL) for hydrogen production: A review of system design components and advancements
- 7 June 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 144, 336-358
A direct seawater electrolysis (DSWEL) for hydrogen production: A review of system design components and advancements
- Open Access
- 30 January 2023
- Published by Penerbit Universiti Kebangsaan Malaysia (UKM Press) in Jurnal Kejuruteraan
- Vol. 35 (1) , 223-230
Static Stress Analysis of Membrane Electrode Assembly (MEA) and Gasket in Proton Exchange Membrane Fuel Cell Stack Assembly Pressure
The proton exchange membrane fuel cell (PEMFC) system was an electrochemical device that generates electricity through the reaction of hydrogen and oxygen without combustion. Proton Exchange Membrane (PEM) stacks typically consisted of components combined into one unit and equipped with suitable clamping torque. This was to prevent reactant gas leakage and minimize the contact resistance between the gas diffusion medium and the bipolar plate. The combined components consisted of a bipolar plate with a flow field, current collector, membrane electrode assembly (MEA), endplate, and gasket. PEMFC performance was measured concerning its power output, which depends on temperature and the operating pressure. Various efforts had been made to determine the optimal compaction pressure and its distribution through simulations and experiments. Therefore, this research analyzed the static stress of membrane electrode assembly (MEA) and gasket in PEMFC stack assembly pressure. The components’ geometric dimensions and mechanical properties, such as endplates, current collectors, bipolar plates, MEAs, and gaskets, were combined for electricity. Pressure-sensitive film (Fuji measure film prescale) was also used to visualize contact pressure distribution between the MEA and the bipolar plate. The result showed that the color variation of the pressure film indicates the exact distribution of pressure entering the stacking design and the contact image. In conclusion, the detailed contact pressure distribution was an important influence on heat transfer processes and local electrochemical reactions in cell stacks.
- 30 January 2023
- Published by Penerbit Universiti Kebangsaan Malaysia (UKM Press) in Jurnal Kejuruteraan
- Vol. 35 (1) , 223-230
Open AccessStatic Stress Analysis of Membrane Electrode Assembly (MEA) and Gasket in Proton Exchange Membrane Fuel Cell Stack Assembly Pressure
The proton exchange membrane fuel cell (PEMFC) system was an electrochemical device that generates electricity through the reaction of hydrogen and oxygen without combustion. Proton Exchange Membrane (PEM) stacks typically consisted of components combined into one unit and equipped with suitable clamping torque. This was to prevent reactant gas leakage and minimize the contact resistance between the gas diffusion medium and the bipolar plate. The combined components consisted of a bipolar plate with a flow field, current collector, membrane electrode assembly (MEA), endplate, and gasket. PEMFC performance was measured concerning its power output, which depends on temperature and the operating pressure. Various efforts had been made to determine the optimal compaction pressure and its distribution through simulations and experiments. Therefore, this research analyzed the static stress of membrane electrode assembly (MEA) and gasket in PEMFC stack assembly pressure. The components’ geometric dimensions and mechanical properties, such as endplates, current collectors, bipolar plates, MEAs, and gaskets, were combined for electricity. Pressure-sensitive film (Fuji measure film prescale) was also used to visualize contact pressure distribution between the MEA and the bipolar plate. The result showed that the color variation of the pressure film indicates the exact distribution of pressure entering the stacking design and the contact image. In conclusion, the detailed contact pressure distribution was an important influence on heat transfer processes and local electrochemical reactions in cell stacks.
- Top Cited Papers
- 23 September 2022
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 47 (85) , 35976-35989
Factors influencing the performance and durability of polymer electrolyte membrane water electrolyzer: A review
- 23 September 2022
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 47 (85) , 35976-35989
Top Cited PapersFactors influencing the performance and durability of polymer electrolyte membrane water electrolyzer: A review
- Top Cited Papers
- 14 July 2022
- Published by Elsevier in Energy Conversion and Management
- Vol. 268
High-pressure PEM water electrolyser: A review on challenges and mitigation strategies towards green and low-cost hydrogen production
- 14 July 2022
- Published by Elsevier in Energy Conversion and Management
- Vol. 268
Top Cited PapersHigh-pressure PEM water electrolyser: A review on challenges and mitigation strategies towards green and low-cost hydrogen production
- 16 August 2021
- Published by Wiley in International Journal of Energy Research
- Vol. 45 (15) , 20583-20600
Review on bipolar plates for low‐temperature polymer electrolyte membrane water electrolyzer
- 16 August 2021
- Published by Wiley in International Journal of Energy Research
- Vol. 45 (15) , 20583-20600
Review on bipolar plates for low‐temperature polymer electrolyte membrane water electrolyzer
- 30 November 2020
- Published by Penerbit Universiti Kebangsaan Malaysia (UKM Press) in Jurnal Kejuruteraan
- Vol. 32 (4) , 591-597
Single Stack Performance using Chromium Carbide (Cr‒C) and Niobium Carbide (Nb‒C) Coated on 316 L Bipolar Plates
- 30 November 2020
- Published by Penerbit Universiti Kebangsaan Malaysia (UKM Press) in Jurnal Kejuruteraan
- Vol. 32 (4) , 591-597
Single Stack Performance using Chromium Carbide (Cr‒C) and Niobium Carbide (Nb‒C) Coated on 316 L Bipolar Plates
- 1 November 2019
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 44 (58) , 30618-30626
Fibre orientation effect on polypropylene/milled carbon fiber composites in the presence of carbon nanotubes or graphene as a secondary filler: Application on PEM fuel cell bipolar plate
- 1 November 2019
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 44 (58) , 30618-30626
Fibre orientation effect on polypropylene/milled carbon fiber composites in the presence of carbon nanotubes or graphene as a secondary filler: Application on PEM fuel cell bipolar plate