Kenneth P. Ishida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kenneth P. Ishida has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Megan H. Plumlee
Research and Development Department Orange County Water District Fountain Valley California USA
6 shared publications - Hitoshi Kodamatani
Chemistry Program, Graduate School of Science and Engineering, Kagoshima University, 1-21-35 Korimoto, Kagoshima 890-0065, Japan
3 shared publications Andrew Poustie
Civil and Environmental Engineering Department, University of Nevada, Reno, NV, USA
2 shared publications- David Hanigan
Department of Civil and Environmental Engineering, University of Nevada, Reno, NV, 89557, USA
2 shared publications - E. Michael Thurman
Center for Environmental Mass Spectrometry, University of Colorado, Boulder, CO, USA
2 shared publications - Imma Ferrer
Center for Environmental Mass Spectrometry, University of Colorado, Boulder, CO, USA
2 shared publications
Latest Publications
- Open Access
- 12 May 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (10) , 4052
Optimization of Dissolved Silica Removal from Reverse Osmosis Concentrate by Gedaniella flavovirens for Enhanced Water Recovery
Photobiological treatment of reverse osmosis concentrate (ROC) using brackish diatoms is a green and sustainable technology that can enhance water recovery by removing dissolved silica from ROC while producing beneficial biomass. This study aimed to determine the optimum conditions for the photobiological treatment of ROC obtained from a full-scale advanced water purification facility using Gedaniella flavovirens Psetr3. While light color presented minor impacts on the silica uptake rate, the impact of color intensity was significant. The uptake rate improved from 28 ± 1 to 48 ± 7 mg/L/day by increasing photosynthetically active radiation (PAR) from 50 to 310 µmol m−2 s−1. Increasing the PAR further did not improve the performance. The optimum temperature was around 23–30 °C. While the silica uptake was slower at 10 °C, G. flavovirens Psetr3 was unable to survive at 40 °C. Experiments using sunlight as a light source verified the impact of temperature on the silica uptake and the detrimental effect of ultraviolet radiation on this diatom. The sunlight-based treatment effectively removed N-nitrosodimethylamine. The results of this study are being used in subsequent pilot-scale investigations and full-scale technoeconomic analysis and will contribute to the further development of this sustainable water technology.
- 12 May 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (10) , 4052
Open AccessOptimization of Dissolved Silica Removal from Reverse Osmosis Concentrate by Gedaniella flavovirens for Enhanced Water Recovery
Photobiological treatment of reverse osmosis concentrate (ROC) using brackish diatoms is a green and sustainable technology that can enhance water recovery by removing dissolved silica from ROC while producing beneficial biomass. This study aimed to determine the optimum conditions for the photobiological treatment of ROC obtained from a full-scale advanced water purification facility using Gedaniella flavovirens Psetr3. While light color presented minor impacts on the silica uptake rate, the impact of color intensity was significant. The uptake rate improved from 28 ± 1 to 48 ± 7 mg/L/day by increasing photosynthetically active radiation (PAR) from 50 to 310 µmol m−2 s−1. Increasing the PAR further did not improve the performance. The optimum temperature was around 23–30 °C. While the silica uptake was slower at 10 °C, G. flavovirens Psetr3 was unable to survive at 40 °C. Experiments using sunlight as a light source verified the impact of temperature on the silica uptake and the detrimental effect of ultraviolet radiation on this diatom. The sunlight-based treatment effectively removed N-nitrosodimethylamine. The results of this study are being used in subsequent pilot-scale investigations and full-scale technoeconomic analysis and will contribute to the further development of this sustainable water technology.
- 26 September 2023
- Published by Elsevier in Chemosphere
- Vol. 344, 140308
Methyl nitrate as a byproduct in advanced water treatment systems: Liquid chromatographic determination method and cause of formation
- 26 September 2023
- Published by Elsevier in Chemosphere
- Vol. 344, 140308
Methyl nitrate as a byproduct in advanced water treatment systems: Liquid chromatographic determination method and cause of formation
- Open Access
- 1 September 2023
- Published by IWA Publishing in Water Reuse
- Vol. 13 (3) , 305-318
Permeate quality, advanced oxidation process treatability, and cost for two concentrate treatment technologies to enhance recovery for potable reuse
Closed circuit reverse osmosis (CCRO) and forward osmosis-RO (FO-RO) were evaluated at a pilot scale to generate additional permeate from RO concentrate – achieving a recovery of 61% for CCRO and 35% for FO-RO – at a full-scale advanced water purification facility. This study assessed permeate water quality, suitability of the permeate for treatment by an ultraviolet-advanced oxidation process (UV-AOP), and cost/footprint for a conceptual 10- or 20-mgd system. Both technologies demonstrated inorganic, organic, and microbiological constituent removal suitable for blending with primary RO permeate. Virus challenge testing with MS coliphage demonstrated ≥3.7-log removal by both technologies. Pilot-scale UV/hydrogen peroxide AOP treatment of CCRO or FO-RO permeate yielded similar performance (∼1.4-log N-nitrosodimethylamine removal and ∼0.5-log 1,4-dioxane removal) as the full-scale UV-AOP that treats the RO permeate from the purification facility. The estimated full-scale total unit cost (capital plus operation and maintenance costs) of product water produced by the two technologies was estimated to range from $0.91 to $1.12 per cubic meter, depending on the design flow rate of RO concentrate treated, and is estimated to be similar between the two technologies given the +50%/–30% expected accuracy of the Class 5 cost estimate.
- 1 September 2023
- Published by IWA Publishing in Water Reuse
- Vol. 13 (3) , 305-318
Open AccessPermeate quality, advanced oxidation process treatability, and cost for two concentrate treatment technologies to enhance recovery for potable reuse
Closed circuit reverse osmosis (CCRO) and forward osmosis-RO (FO-RO) were evaluated at a pilot scale to generate additional permeate from RO concentrate – achieving a recovery of 61% for CCRO and 35% for FO-RO – at a full-scale advanced water purification facility. This study assessed permeate water quality, suitability of the permeate for treatment by an ultraviolet-advanced oxidation process (UV-AOP), and cost/footprint for a conceptual 10- or 20-mgd system. Both technologies demonstrated inorganic, organic, and microbiological constituent removal suitable for blending with primary RO permeate. Virus challenge testing with MS coliphage demonstrated ≥3.7-log removal by both technologies. Pilot-scale UV/hydrogen peroxide AOP treatment of CCRO or FO-RO permeate yielded similar performance (∼1.4-log N-nitrosodimethylamine removal and ∼0.5-log 1,4-dioxane removal) as the full-scale UV-AOP that treats the RO permeate from the purification facility. The estimated full-scale total unit cost (capital plus operation and maintenance costs) of product water produced by the two technologies was estimated to range from $0.91 to $1.12 per cubic meter, depending on the design flow rate of RO concentrate treated, and is estimated to be similar between the two technologies given the +50%/–30% expected accuracy of the Class 5 cost estimate.
- Open Access
- 17 February 2022
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 8 (3) , 686
Correction: Non-target mass spectrometry analysis of NDMA precursors in advanced treatment for potable reuse
Correction for ‘Non-target mass spectrometry analysis of NDMA precursors in advanced treatment for potable reuse’ by Shannon L. Roback et al., Environ. Sci.: Water Res. Technol., 2018, 4, 1944–1955, DOI: 10.1039/C8EW00401C.
- 17 February 2022
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 8 (3) , 686
Open AccessCorrection: Non-target mass spectrometry analysis of NDMA precursors in advanced treatment for potable reuse
Correction for ‘Non-target mass spectrometry analysis of NDMA precursors in advanced treatment for potable reuse’ by Shannon L. Roback et al., Environ. Sci.: Water Res. Technol., 2018, 4, 1944–1955, DOI: 10.1039/C8EW00401C.
- 1 January 2022
- Published by Elsevier in Water Research
- Vol. 208, 117868
Corrigendum to Pilot-scale evaluation of oxidant speciation, 1,4-dioxane degradation and disinfection byproduct formation during UV/hydrogen peroxide, UV/free chlorine and UV/chloramines advanced oxidation process treatment for potable reuse’[Water Research, Volume 164, 1 November 2019, 114939]
- 1 January 2022
- Published by Elsevier in Water Research
- Vol. 208, 117868
Corrigendum to Pilot-scale evaluation of oxidant speciation, 1,4-dioxane degradation and disinfection byproduct formation during UV/hydrogen peroxide, UV/free chlorine and UV/chloramines advanced oxidation process treatment for potable reuse’[Water Research, Volume 164, 1 November 2019, 114939]
- 17 July 2020
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 6 (9) , 2416-2431
UV/chlorine vs. UV/H2O2 for water reuse at Orange County Water District, CA: a pilot study
On-site demonstration tests evaluated 1,4-dioxane removal in reverse osmosis permeate (RO permeate) at the Orange County Water District (OCWD) Advanced Water Purification Facility (AWPF). The study used a pilot-scale ultraviolet (UV) reactor to compare efficacy of UV/chloramine, UV/chloramine/H2O2 and UV/chloramine/HOCl advanced oxidation processes (AOPs). The UV/chloramine process did not achieve the targeted 0.5 log removal of 1,4-dioxane even at a high UV fluence of 4400 mJ cm−2 and the 1,4-dioxane decay did not follow pseudo-first order kinetics. Oxidant concentrations as low as 2.6 mg L−1 H2O2 or ∼1.0 mg L−1 free Cl2 (HOCl) in the RO permeate at ambient quality parameters, e.g. 2.2–2.4 mg L−1 monochloramine (as Cl2), 1.2–1.4 mg L−1 dichloramine (as Cl2), ≤0.08 mg L−1 NO2 − (UV/H2O2 AOP), ∼97.0% T, resulted in 0.56 and ≥0.51 log reduction of 1,4-dioxane with the UV/chloramine/H2O2 and UV/chloramine/HOCl process, respectively, while simultaneously achieving ∼2.0 log reduction of NDMA. Overall, the UV/chloramine/HOCl process showed higher removal efficiency of 1,4-dioxane than UV/chloramine/H2O2 for the same mass-based oxidant concentrations and process conditions. Nitrite ions present in the RO permeate and/or generated from monochloramine photolysis during the UV/AOP impacted significantly the process performance. It was confirmed through these pilot-scale tests that the removal of 1,4-dioxane in the UV/chloramine/H2O2 and UV/chloramine/HOCl processes can be predicted accurately with a comprehensive mechanistic kinetic model that accounts for the molecular and radical reactions that occur in the RO permeate in the UV reactor.
- 17 July 2020
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 6 (9) , 2416-2431
UV/chlorine vs. UV/H2O2 for water reuse at Orange County Water District, CA: a pilot study
On-site demonstration tests evaluated 1,4-dioxane removal in reverse osmosis permeate (RO permeate) at the Orange County Water District (OCWD) Advanced Water Purification Facility (AWPF). The study used a pilot-scale ultraviolet (UV) reactor to compare efficacy of UV/chloramine, UV/chloramine/H2O2 and UV/chloramine/HOCl advanced oxidation processes (AOPs). The UV/chloramine process did not achieve the targeted 0.5 log removal of 1,4-dioxane even at a high UV fluence of 4400 mJ cm−2 and the 1,4-dioxane decay did not follow pseudo-first order kinetics. Oxidant concentrations as low as 2.6 mg L−1 H2O2 or ∼1.0 mg L−1 free Cl2 (HOCl) in the RO permeate at ambient quality parameters, e.g. 2.2–2.4 mg L−1 monochloramine (as Cl2), 1.2–1.4 mg L−1 dichloramine (as Cl2), ≤0.08 mg L−1 NO2 − (UV/H2O2 AOP), ∼97.0% T, resulted in 0.56 and ≥0.51 log reduction of 1,4-dioxane with the UV/chloramine/H2O2 and UV/chloramine/HOCl process, respectively, while simultaneously achieving ∼2.0 log reduction of NDMA. Overall, the UV/chloramine/HOCl process showed higher removal efficiency of 1,4-dioxane than UV/chloramine/H2O2 for the same mass-based oxidant concentrations and process conditions. Nitrite ions present in the RO permeate and/or generated from monochloramine photolysis during the UV/AOP impacted significantly the process performance. It was confirmed through these pilot-scale tests that the removal of 1,4-dioxane in the UV/chloramine/H2O2 and UV/chloramine/HOCl processes can be predicted accurately with a comprehensive mechanistic kinetic model that accounts for the molecular and radical reactions that occur in the RO permeate in the UV reactor.
- 4 October 2018
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 4 (12) , 1944-1955
Non-target mass spectrometry analysis of NDMA precursors in advanced treatment for potable reuse
N-Nitrosodimethylamine (NDMA) is a disinfection by-product of concern in water reuse applications due to its potential human carcinogenicity. NDMA forms via the reaction of organic amine precursors with chloramines during water treatment. Advanced treatment for potable reuse reduces NDMA to non-detectable levels and removes most precursors. However, historical data from a full-scale potable reuse facility indicates NDMA can form after advanced treatment due to the presence of residual chloramine and NDMA precursors that are not removed during advanced treatment. This study used non-target high-resolution mass spectrometry to identify NDMA precursors and other trace organic compounds during advanced treatment for reuse. Inspection of the total ion chromatograms indicated that there was a substantial reduction of total ionizable compounds by reverse osmosis (RO). The RO feed water contained approximately 22 putative identifications of NDMA precursors across two sampling events. Only one of these precursors was found post-RO and none were found in the subsequent UV/advanced oxidation process (AOP) product water. In addition to the 22 NDMA precursors, the RO feed water contained 41 pharmaceuticals and pesticides that are not likely to be NDMA precursors. Similarly, these compounds were generally well removed by RO. Two compounds with unknown NDMA formation potential, one a suspected benzotriazole trimer with chemical formula C18H16N6O3 and the other with an unassigned formula, were identified in the UV/AOP product water that were not present prior to UV/AOP (after RO), indicating they may be transformation products. Overall, this research demonstrates the utility of non-target analysis for water quality investigations.
- 4 October 2018
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 4 (12) , 1944-1955
Non-target mass spectrometry analysis of NDMA precursors in advanced treatment for potable reuse
N-Nitrosodimethylamine (NDMA) is a disinfection by-product of concern in water reuse applications due to its potential human carcinogenicity. NDMA forms via the reaction of organic amine precursors with chloramines during water treatment. Advanced treatment for potable reuse reduces NDMA to non-detectable levels and removes most precursors. However, historical data from a full-scale potable reuse facility indicates NDMA can form after advanced treatment due to the presence of residual chloramine and NDMA precursors that are not removed during advanced treatment. This study used non-target high-resolution mass spectrometry to identify NDMA precursors and other trace organic compounds during advanced treatment for reuse. Inspection of the total ion chromatograms indicated that there was a substantial reduction of total ionizable compounds by reverse osmosis (RO). The RO feed water contained approximately 22 putative identifications of NDMA precursors across two sampling events. Only one of these precursors was found post-RO and none were found in the subsequent UV/advanced oxidation process (AOP) product water. In addition to the 22 NDMA precursors, the RO feed water contained 41 pharmaceuticals and pesticides that are not likely to be NDMA precursors. Similarly, these compounds were generally well removed by RO. Two compounds with unknown NDMA formation potential, one a suspected benzotriazole trimer with chemical formula C18H16N6O3 and the other with an unassigned formula, were identified in the UV/AOP product water that were not present prior to UV/AOP (after RO), indicating they may be transformation products. Overall, this research demonstrates the utility of non-target analysis for water quality investigations.
- 14 September 2017
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 3 (6) , 1032-1036
Near real-time N-nitrosodimethylamine monitoring in potable water reuse via online high-performance liquid chromatography-photochemical reaction-chemiluminescence
Direct potable reuse requires stringent water quality assurance to protect public health. This study developed an online analytical technique—high-performance liquid chromatography followed by photochemical reaction and chemiluminescence detection (HPLC-PR-CL)—for determination of the concentration of N-nitrosodimethylamine (NDMA) and three other N-nitrosamines. Its feasibility for near real-time analysis was evaluated by analyzing an ultrafiltration (UF)-treated wastewater before and after a pilot-scale reverse osmosis (RO) treatment system. The online instrument with a method detection limit of 0.3–2.7 ng L−1 requires a direct injection (i.e., no sample pre-concentration) of only 20–200 μL sample volume for the determination of N-nitrosamine concentrations every 20 min. NDMA concentrations in UF-treated wastewater were successfully monitored in a range of 50–200 ng L−1 over the course of 24 h. Likewise, NDMA concentrations in RO permeate ranged from 26–81 ng L−1 over the course of 48 h. The online monitor was capable of recording variations in N-nitrosamine concentration in RO permeate that occurred following changes in feedwater concentration and temperature. This study demonstrates the potential for online water quality assurance via direct measurement of trace levels of organic contaminants, which is highly relevant to the implementation of potable reuse.
- 14 September 2017
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 3 (6) , 1032-1036
Near real-time N-nitrosodimethylamine monitoring in potable water reuse via online high-performance liquid chromatography-photochemical reaction-chemiluminescence
Direct potable reuse requires stringent water quality assurance to protect public health. This study developed an online analytical technique—high-performance liquid chromatography followed by photochemical reaction and chemiluminescence detection (HPLC-PR-CL)—for determination of the concentration of N-nitrosodimethylamine (NDMA) and three other N-nitrosamines. Its feasibility for near real-time analysis was evaluated by analyzing an ultrafiltration (UF)-treated wastewater before and after a pilot-scale reverse osmosis (RO) treatment system. The online instrument with a method detection limit of 0.3–2.7 ng L−1 requires a direct injection (i.e., no sample pre-concentration) of only 20–200 μL sample volume for the determination of N-nitrosamine concentrations every 20 min. NDMA concentrations in UF-treated wastewater were successfully monitored in a range of 50–200 ng L−1 over the course of 24 h. Likewise, NDMA concentrations in RO permeate ranged from 26–81 ng L−1 over the course of 48 h. The online monitor was capable of recording variations in N-nitrosamine concentration in RO permeate that occurred following changes in feedwater concentration and temperature. This study demonstrates the potential for online water quality assurance via direct measurement of trace levels of organic contaminants, which is highly relevant to the implementation of potable reuse.