Megan H. Plumlee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Megan H. Plumlee has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Kenneth P. Ishida
Orange County Water District, Fountain Valley, CA 92708, USA
6 shared publications - Shannon L. Roback
Environmental Science and Engineering Program, Institute for the Environment and Sustainability, University of California, Los Angeles, La Kretz Hall, Suite 300, Box 951496, Los Angeles, CA 90095-1496, USA; Metropolitan Water District of Southern California, 700 Moreno Avenue, La Verne, CA 91750, USA
4 shared publications - Christine Pham
Research and Development Department Orange County Water District Anaheim California USA
3 shared publications - Hitoshi Kodamatani
Chemistry Program, Graduate School of Science and Engineering, Kagoshima University, 1-21-35 Korimoto, Kagoshima 890-0065, Japan
3 shared publications - Jana Safarik
Orange County Water District, 18700 Ward St, Fountain Valley, CA 92708, USA
3 shared publications - Manmeet W. Pannu
Research and Development Department Orange County Water District Fountain Valley California USA
3 shared publications
Latest Publications
- 8 September 2026
- Published by Wiley in AWWA Water Science
- Vol. 8 (5)
PIGE to Measure AOF Reveals Limited PFAS Removal by Adsorbents in Water
Rapid, gravity‐driven solid‐phase extraction (SPE) using graphitized activated carbon felt (GACF) followed by Particle‐Induced Gamma‐ray Emission (PIGE) spectroscopy is useful for aqueous per/poly‐fluoroalkyl substances (PFAS) screening via measurement of Adsorbable Organic Fluorine (AOF, reporting limit: 100 ppt as F). Moderately high dissolved organic content may compete for PFAS binding sites on the GACF, and inorganic fluoride may result in AOF overestimation due to PIGE's lack of selectivity. Here, sample pre‐treatment with Fenton's reagent and acidification improved method performance by mitigating matrix interferences. The modified method was used to rapidly screen AOF in > 200 surface‐, recycled‐, and ground‐water samples from Orange County, California. Comparison to LC–MS/MS measurements indicated that GACF/PIGE captured substantial additional organic fluorine not measured by targeted methods. GACF/PIGE tests revealed limited removal of AOF by commercial PFAS adsorbents from groundwater in a drinking water treatment application. The current data collected on ultra short chains are insufficient to determine their relative contribution to the total measured AOF and requires further investigation.
- 8 September 2026
- Published by Wiley in AWWA Water Science
- Vol. 8 (5)
PIGE to Measure AOF Reveals Limited PFAS Removal by Adsorbents in Water
Rapid, gravity‐driven solid‐phase extraction (SPE) using graphitized activated carbon felt (GACF) followed by Particle‐Induced Gamma‐ray Emission (PIGE) spectroscopy is useful for aqueous per/poly‐fluoroalkyl substances (PFAS) screening via measurement of Adsorbable Organic Fluorine (AOF, reporting limit: 100 ppt as F). Moderately high dissolved organic content may compete for PFAS binding sites on the GACF, and inorganic fluoride may result in AOF overestimation due to PIGE's lack of selectivity. Here, sample pre‐treatment with Fenton's reagent and acidification improved method performance by mitigating matrix interferences. The modified method was used to rapidly screen AOF in > 200 surface‐, recycled‐, and ground‐water samples from Orange County, California. Comparison to LC–MS/MS measurements indicated that GACF/PIGE captured substantial additional organic fluorine not measured by targeted methods. GACF/PIGE tests revealed limited removal of AOF by commercial PFAS adsorbents from groundwater in a drinking water treatment application. The current data collected on ultra short chains are insufficient to determine their relative contribution to the total measured AOF and requires further investigation.
- Open Access
- 11 April 2026
- Published by Elsevier in SSRN Electronic Journal
Nanopore Sequencing to Track Core Microbial Communities in Potable Reuse: Considerations for Utility-Driven Water Quality Monitoring
Potable water reuse facilities require reliable and robust monitoring practices to verify the removal of both chemical and biological constituents. Microbial monitoring relies primarily on fecal indicator bacteria, an approach that has changed little in decades and provides limited insight into the broader microbial community. We conducted a two-year environmental DNA (eDNA) monitoring program at four locations within an advanced water purification facility (AWPF) to evaluate the feasibility of implementing nanopore sequencing for routine microbial assessment. eDNA was detected at all treatment stages, with greater concentrations observed in secondary-treated wastewater (77 µg/L before and 57 µg/L after chloramine addition) which serves as the AWPF influent. Substantially lower concentrations were observed after microfiltration/ultrafiltration (MF/UF) (5 µg/L), which serves as pretreatment before reverse osmosis (RO), and in ultraviolet advanced oxidation process (UV-AOP) product water (0.6 µg/L). Due to low eDNA yields despite optimization attempts, only AWPF influent samples (before and after chloramine addition) could be sequenced, indicating nanopore sequencing is not yet practical for later treatment steps that produce increasingly treated (purified) water. A total of 7,734 and 7,617 unique species were identified in AWPF influent and chloraminated influent, respectively. Findings suggest that a core bacterial community persists over time in influent samples. Although molecular tools have become increasingly affordable, characterizing the limited available quantities of eDNA isolated from highly treated water proved impractical for feasible implementation by utilities. As an alternative, monitoring total eDNA mass could serve as a practical tool for continuous monitoring.
- 11 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNanopore Sequencing to Track Core Microbial Communities in Potable Reuse: Considerations for Utility-Driven Water Quality Monitoring
Potable water reuse facilities require reliable and robust monitoring practices to verify the removal of both chemical and biological constituents. Microbial monitoring relies primarily on fecal indicator bacteria, an approach that has changed little in decades and provides limited insight into the broader microbial community. We conducted a two-year environmental DNA (eDNA) monitoring program at four locations within an advanced water purification facility (AWPF) to evaluate the feasibility of implementing nanopore sequencing for routine microbial assessment. eDNA was detected at all treatment stages, with greater concentrations observed in secondary-treated wastewater (77 µg/L before and 57 µg/L after chloramine addition) which serves as the AWPF influent. Substantially lower concentrations were observed after microfiltration/ultrafiltration (MF/UF) (5 µg/L), which serves as pretreatment before reverse osmosis (RO), and in ultraviolet advanced oxidation process (UV-AOP) product water (0.6 µg/L). Due to low eDNA yields despite optimization attempts, only AWPF influent samples (before and after chloramine addition) could be sequenced, indicating nanopore sequencing is not yet practical for later treatment steps that produce increasingly treated (purified) water. A total of 7,734 and 7,617 unique species were identified in AWPF influent and chloraminated influent, respectively. Findings suggest that a core bacterial community persists over time in influent samples. Although molecular tools have become increasingly affordable, characterizing the limited available quantities of eDNA isolated from highly treated water proved impractical for feasible implementation by utilities. As an alternative, monitoring total eDNA mass could serve as a practical tool for continuous monitoring.
- Open Access
- 27 September 2023
- Published by Public Library of Science (PLoS) in PLOS Water
- Vol. 2 (9) , e0000052
Enteric virus removal by municipal wastewater treatment to achieve requirements for potable reuse
Primary and secondary treatment of municipal wastewater contributes to virus removal upstream of advanced purification to produce water for potable reuse. In this study, virus occurrence by cultivable and molecular methods was measured over a 24-month period in raw wastewater influents and secondary effluents from two municipal wastewater treatment plants that together provide the recycled water source for an advanced water purification facility. Using a rank-paired, covariance-based statistical approach, virus log removal values were determined for four wastewater treatment processes that operate in parallel at the two facilities (two activated sludge processes, trickling filter process, and trickling filter/solids contactor process). The trickling filter process exhibited the lowest observed removal of cultivable enteric virus with a median removal of 1.0 log10 (or 90% removal) and a 5th percentile log removal of 0.73 (or 82%), compared to the greatest removal observed for one of the activated sludge processes (median log removal of 2.4 or 99.6% and 5th percentile of 2.1 or 99.2%). Median log removal observed for male-specific (MS) and somatic (SOM) coliphage was 1.8 (98.6% removal) and 0.5 (70%), respectively, for trickling filter and 2.9 (99.9%) and 2.0 (99%) for activated sludge. Thus, coliphage removal was fairly similar to removal observed for cultivable enteric virus. The cultivable enteric virus 5th percentile removal (0.7) from the trickling filter treatment process was proposed to the state regulator for credit towards state requirements for virus removal related to groundwater augmentation with purified recycled water. Receiving pathogen removal credits for secondary wastewater treatment would allow for an improved margin (safety factor) of credits beyond the minimum required; and in this case may also increase the number of viable future groundwater recharge sites closer to drinking water production wells by reducing the underground travel time otherwise required to obtain sufficient credits.
- 27 September 2023
- Published by Public Library of Science (PLoS) in PLOS Water
- Vol. 2 (9) , e0000052
Open AccessEnteric virus removal by municipal wastewater treatment to achieve requirements for potable reuse
Primary and secondary treatment of municipal wastewater contributes to virus removal upstream of advanced purification to produce water for potable reuse. In this study, virus occurrence by cultivable and molecular methods was measured over a 24-month period in raw wastewater influents and secondary effluents from two municipal wastewater treatment plants that together provide the recycled water source for an advanced water purification facility. Using a rank-paired, covariance-based statistical approach, virus log removal values were determined for four wastewater treatment processes that operate in parallel at the two facilities (two activated sludge processes, trickling filter process, and trickling filter/solids contactor process). The trickling filter process exhibited the lowest observed removal of cultivable enteric virus with a median removal of 1.0 log10 (or 90% removal) and a 5th percentile log removal of 0.73 (or 82%), compared to the greatest removal observed for one of the activated sludge processes (median log removal of 2.4 or 99.6% and 5th percentile of 2.1 or 99.2%). Median log removal observed for male-specific (MS) and somatic (SOM) coliphage was 1.8 (98.6% removal) and 0.5 (70%), respectively, for trickling filter and 2.9 (99.9%) and 2.0 (99%) for activated sludge. Thus, coliphage removal was fairly similar to removal observed for cultivable enteric virus. The cultivable enteric virus 5th percentile removal (0.7) from the trickling filter treatment process was proposed to the state regulator for credit towards state requirements for virus removal related to groundwater augmentation with purified recycled water. Receiving pathogen removal credits for secondary wastewater treatment would allow for an improved margin (safety factor) of credits beyond the minimum required; and in this case may also increase the number of viable future groundwater recharge sites closer to drinking water production wells by reducing the underground travel time otherwise required to obtain sufficient credits.
- 26 September 2023
- Published by Elsevier in Chemosphere
- Vol. 344, 140308
Methyl nitrate as a byproduct in advanced water treatment systems: Liquid chromatographic determination method and cause of formation
- 26 September 2023
- Published by Elsevier in Chemosphere
- Vol. 344, 140308
Methyl nitrate as a byproduct in advanced water treatment systems: Liquid chromatographic determination method and cause of formation
- Open Access
- 1 September 2023
- Published by IWA Publishing in Water Reuse
- Vol. 13 (3) , 305-318
Permeate quality, advanced oxidation process treatability, and cost for two concentrate treatment technologies to enhance recovery for potable reuse
Closed circuit reverse osmosis (CCRO) and forward osmosis-RO (FO-RO) were evaluated at a pilot scale to generate additional permeate from RO concentrate – achieving a recovery of 61% for CCRO and 35% for FO-RO – at a full-scale advanced water purification facility. This study assessed permeate water quality, suitability of the permeate for treatment by an ultraviolet-advanced oxidation process (UV-AOP), and cost/footprint for a conceptual 10- or 20-mgd system. Both technologies demonstrated inorganic, organic, and microbiological constituent removal suitable for blending with primary RO permeate. Virus challenge testing with MS coliphage demonstrated ≥3.7-log removal by both technologies. Pilot-scale UV/hydrogen peroxide AOP treatment of CCRO or FO-RO permeate yielded similar performance (∼1.4-log N-nitrosodimethylamine removal and ∼0.5-log 1,4-dioxane removal) as the full-scale UV-AOP that treats the RO permeate from the purification facility. The estimated full-scale total unit cost (capital plus operation and maintenance costs) of product water produced by the two technologies was estimated to range from $0.91 to $1.12 per cubic meter, depending on the design flow rate of RO concentrate treated, and is estimated to be similar between the two technologies given the +50%/–30% expected accuracy of the Class 5 cost estimate.
- 1 September 2023
- Published by IWA Publishing in Water Reuse
- Vol. 13 (3) , 305-318
Open AccessPermeate quality, advanced oxidation process treatability, and cost for two concentrate treatment technologies to enhance recovery for potable reuse
Closed circuit reverse osmosis (CCRO) and forward osmosis-RO (FO-RO) were evaluated at a pilot scale to generate additional permeate from RO concentrate – achieving a recovery of 61% for CCRO and 35% for FO-RO – at a full-scale advanced water purification facility. This study assessed permeate water quality, suitability of the permeate for treatment by an ultraviolet-advanced oxidation process (UV-AOP), and cost/footprint for a conceptual 10- or 20-mgd system. Both technologies demonstrated inorganic, organic, and microbiological constituent removal suitable for blending with primary RO permeate. Virus challenge testing with MS coliphage demonstrated ≥3.7-log removal by both technologies. Pilot-scale UV/hydrogen peroxide AOP treatment of CCRO or FO-RO permeate yielded similar performance (∼1.4-log N-nitrosodimethylamine removal and ∼0.5-log 1,4-dioxane removal) as the full-scale UV-AOP that treats the RO permeate from the purification facility. The estimated full-scale total unit cost (capital plus operation and maintenance costs) of product water produced by the two technologies was estimated to range from $0.91 to $1.12 per cubic meter, depending on the design flow rate of RO concentrate treated, and is estimated to be similar between the two technologies given the +50%/–30% expected accuracy of the Class 5 cost estimate.
- Open Access
- 1 May 2023
- Published by Wiley in AWWA Water Science
- Vol. 5 (3)
Comparing PFAS removal across multiple groundwaters for eight GACs and alternative adsorbent
Eight granular activated carbons (GACs) and one alternative adsorbent (AA) were evaluated using rapid small‐scale column tests (RSSCTs) to remove low level per‐ and polyfluoroalkyl substances (PFAS) from several groundwaters. Results suggested variability among waters for adsorbents to reach breakthrough. Time to reach breakthrough appeared to be inversely proportional to the background dissolved organic carbon (DOC). Bituminous GACs (particularly F400 and UC1240LD) were more effective than non‐bituminous. The elution order for PFAS was PFHxA (C6) > PFBS (C4) > PFOA (C8) > PFHxS (C6) > PFOS (C8). Multivariate regression predicted bed volumes at which F400 reached significant exhaustion (defined here as 60%) for PFOA using only two parameters (humic acid, DOC). This merits further study as these parameters could potentially be incorporated into models for predicting PFAS breakthrough. VOCs presence negatively impacted PFAS adsorption on GAC. Relative to GACs, the AA was not nearly as impacted by DOC and showed superior performance.
- 1 May 2023
- Published by Wiley in AWWA Water Science
- Vol. 5 (3)
Open AccessComparing PFAS removal across multiple groundwaters for eight GACs and alternative adsorbent
Eight granular activated carbons (GACs) and one alternative adsorbent (AA) were evaluated using rapid small‐scale column tests (RSSCTs) to remove low level per‐ and polyfluoroalkyl substances (PFAS) from several groundwaters. Results suggested variability among waters for adsorbents to reach breakthrough. Time to reach breakthrough appeared to be inversely proportional to the background dissolved organic carbon (DOC). Bituminous GACs (particularly F400 and UC1240LD) were more effective than non‐bituminous. The elution order for PFAS was PFHxA (C6) > PFBS (C4) > PFOA (C8) > PFHxS (C6) > PFOS (C8). Multivariate regression predicted bed volumes at which F400 reached significant exhaustion (defined here as 60%) for PFOA using only two parameters (humic acid, DOC). This merits further study as these parameters could potentially be incorporated into models for predicting PFAS breakthrough. VOCs presence negatively impacted PFAS adsorption on GAC. Relative to GACs, the AA was not nearly as impacted by DOC and showed superior performance.
- Open Access
- 22 October 2022
- Published by Elsevier in Science of The Total Environment
- Vol. 859 (Pt 1) , 159575
SARS-CoV-2 genetic material is removed during municipal wastewater treatment and is undetectable after advanced treatment
- 22 October 2022
- Published by Elsevier in Science of The Total Environment
- Vol. 859 (Pt 1) , 159575
Open AccessSARS-CoV-2 genetic material is removed during municipal wastewater treatment and is undetectable after advanced treatment
- 1 September 2022
- Published by Wiley in AWWA Water Science
- Vol. 4 (5)
Pilot‐scale comparison of granular activated carbons, ion exchange, and alternative adsorbents for per‐ and polyfluoroalkyl substances removal
Eight granular activated carbons (GAC), four anion exchange (IX) resins, and two alternative adsorbents (AAs) were tested for the removal of per‐ and polyfluoroalkyl substances (PFAS) from a groundwater source used for drinking water. The study was conducted using pilot(meter)‐scale columns operated in continuous‐flow mode for 16–26 months. Comparison between GAC adsorbents showed that bituminous GACs exhibited higher adsorption than non‐/sub‐bituminous GACs. Testing of a reactivated and new GAC showed no significant differences with respect to PFAS adsorption. Of the four IX resins tested, one resin showed superior adsorption when compared with all three IX resins. A surface‐modified bentonite adsorbent showed superior removal efficiencies over all adsorbent types tested here. These results provide benchmark performance and adsorption capacities at pilot‐scale for various adsorbents and highlight the promise of AAs to remove PFAS from water sources with low (ng/L) concentrations.
- 1 September 2022
- Published by Wiley in AWWA Water Science
- Vol. 4 (5)
Pilot‐scale comparison of granular activated carbons, ion exchange, and alternative adsorbents for per‐ and polyfluoroalkyl substances removal
Eight granular activated carbons (GAC), four anion exchange (IX) resins, and two alternative adsorbents (AAs) were tested for the removal of per‐ and polyfluoroalkyl substances (PFAS) from a groundwater source used for drinking water. The study was conducted using pilot(meter)‐scale columns operated in continuous‐flow mode for 16–26 months. Comparison between GAC adsorbents showed that bituminous GACs exhibited higher adsorption than non‐/sub‐bituminous GACs. Testing of a reactivated and new GAC showed no significant differences with respect to PFAS adsorption. Of the four IX resins tested, one resin showed superior adsorption when compared with all three IX resins. A surface‐modified bentonite adsorbent showed superior removal efficiencies over all adsorbent types tested here. These results provide benchmark performance and adsorption capacities at pilot‐scale for various adsorbents and highlight the promise of AAs to remove PFAS from water sources with low (ng/L) concentrations.
- 15 March 2022
- Published by Elsevier in Water Research
- Vol. 217, 118300
Online colloidal particle monitoring for controlled coagulation pretreatment to lower microfiltration membrane fouling at a potable water reuse facility
- 15 March 2022
- Published by Elsevier in Water Research
- Vol. 217, 118300
Online colloidal particle monitoring for controlled coagulation pretreatment to lower microfiltration membrane fouling at a potable water reuse facility
- Open Access
- 17 February 2022
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 8 (3) , 687
Correction: Validation of a novel direct-injection chemiluminescence-based method for N -nitrosamine analysis in advanced-treated recycled water, drinking water, and wastewater
Correction for ‘Validation of a novel direct-injection chemiluminescence-based method for N -nitrosamine analysis in advanced-treated recycled water, drinking water, and wastewater’ by Shannon L. Roback et al. , Environ. Sci.: Water Res. Technol. , 2020, 6 , 1106–1115, DOI: 10.1039/C9EW00943D.
- 17 February 2022
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 8 (3) , 687
Open AccessCorrection: Validation of a novel direct-injection chemiluminescence-based method for N -nitrosamine analysis in advanced-treated recycled water, drinking water, and wastewater
Correction for ‘Validation of a novel direct-injection chemiluminescence-based method for N -nitrosamine analysis in advanced-treated recycled water, drinking water, and wastewater’ by Shannon L. Roback et al. , Environ. Sci.: Water Res. Technol. , 2020, 6 , 1106–1115, DOI: 10.1039/C9EW00943D.