MPMegan H. Plumlee

Megan H. Plumlee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Megan H. Plumlee has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • PIGE to Measure AOF Reveals Limited PFAS Removal by Adsorbents in Water

    by Yukun Jin, Manmeet W. Pannu, Anthony M. Miller, Meghanne Tighe, Alyssa Wicks, Megan H. Plumlee, Graham F. Peaslee

    Rapid, gravity‐driven solid‐phase extraction (SPE) using graphitized activated carbon felt (GACF) followed by Particle‐Induced Gamma‐ray Emission (PIGE) spectroscopy is useful for aqueous per/poly‐fluoroalkyl substances (PFAS) screening via measurement of Adsorbable Organic Fluorine (AOF, reporting limit: 100 ppt as F). Moderately high dissolved organic content may compete for PFAS binding sites on the GACF, and inorganic fluoride may result in AOF overestimation due to PIGE's lack of selectivity. Here, sample pre‐treatment with Fenton's reagent and acidification improved method performance by mitigating matrix interferences. The modified method was used to rapidly screen AOF in > 200 surface‐, recycled‐, and ground‐water samples from Orange County, California. Comparison to LC–MS/MS measurements indicated that GACF/PIGE captured substantial additional organic fluorine not measured by targeted methods. GACF/PIGE tests revealed limited removal of AOF by commercial PFAS adsorbents from groundwater in a drinking water treatment application. The current data collected on ultra short chains are insufficient to determine their relative contribution to the total measured AOF and requires further investigation.

  • Open Access

    Nanopore Sequencing to Track Core Microbial Communities in Potable Reuse: Considerations for Utility-Driven Water Quality Monitoring

    by Julio A. Polanco, Jana Safarik, Andrew Huang, Megan H. Plumlee

    Potable water reuse facilities require reliable and robust monitoring practices to verify the removal of both chemical and biological constituents. Microbial monitoring relies primarily on fecal indicator bacteria, an approach that has changed little in decades and provides limited insight into the broader microbial community. We conducted a two-year environmental DNA (eDNA) monitoring program at four locations within an advanced water purification facility (AWPF) to evaluate the feasibility of implementing nanopore sequencing for routine microbial assessment. eDNA was detected at all treatment stages, with greater concentrations observed in secondary-treated wastewater (77 µg/L before and 57 µg/L after chloramine addition) which serves as the AWPF influent. Substantially lower concentrations were observed after microfiltration/ultrafiltration (MF/UF) (5 µg/L), which serves as pretreatment before reverse osmosis (RO), and in ultraviolet advanced oxidation process (UV-AOP) product water (0.6 µg/L). Due to low eDNA yields despite optimization attempts, only AWPF influent samples (before and after chloramine addition) could be sequenced, indicating nanopore sequencing is not yet practical for later treatment steps that produce increasingly treated (purified) water. A total of 7,734 and 7,617 unique species were identified in AWPF influent and chloraminated influent, respectively. Findings suggest that a core bacterial community persists over time in influent samples. Although molecular tools have become increasingly affordable, characterizing the limited available quantities of eDNA isolated from highly treated water proved impractical for feasible implementation by utilities. As an alternative, monitoring total eDNA mass could serve as a practical tool for continuous monitoring.

  • Open Access

    Enteric virus removal by municipal wastewater treatment to achieve requirements for potable reuse

    by Julio A. Polanco, Jana Safarik, Jason S. Dadakis, Claire Johnson, Megan H. Plumlee

    Primary and secondary treatment of municipal wastewater contributes to virus removal upstream of advanced purification to produce water for potable reuse. In this study, virus occurrence by cultivable and molecular methods was measured over a 24-month period in raw wastewater influents and secondary effluents from two municipal wastewater treatment plants that together provide the recycled water source for an advanced water purification facility. Using a rank-paired, covariance-based statistical approach, virus log removal values were determined for four wastewater treatment processes that operate in parallel at the two facilities (two activated sludge processes, trickling filter process, and trickling filter/solids contactor process). The trickling filter process exhibited the lowest observed removal of cultivable enteric virus with a median removal of 1.0 log10 (or 90% removal) and a 5th percentile log removal of 0.73 (or 82%), compared to the greatest removal observed for one of the activated sludge processes (median log removal of 2.4 or 99.6% and 5th percentile of 2.1 or 99.2%). Median log removal observed for male-specific (MS) and somatic (SOM) coliphage was 1.8 (98.6% removal) and 0.5 (70%), respectively, for trickling filter and 2.9 (99.9%) and 2.0 (99%) for activated sludge. Thus, coliphage removal was fairly similar to removal observed for cultivable enteric virus. The cultivable enteric virus 5th percentile removal (0.7) from the trickling filter treatment process was proposed to the state regulator for credit towards state requirements for virus removal related to groundwater augmentation with purified recycled water. Receiving pathogen removal credits for secondary wastewater treatment would allow for an improved margin (safety factor) of credits beyond the minimum required; and in this case may also increase the number of viable future groundwater recharge sites closer to drinking water production wells by reducing the underground travel time otherwise required to obtain sufficient credits.


  • Methyl nitrate as a byproduct in advanced water treatment systems: Liquid chromatographic determination method and cause of formation

    by Hitoshi Kodamatani, Kenta Sugihara, Stephen P. Mezyk, Kenneth P. Ishida, Shannon L. Roback, Megan H. Plumlee


  • Open Access

    Permeate quality, advanced oxidation process treatability, and cost for two concentrate treatment technologies to enhance recovery for potable reuse

    by Han Gu, Julio Polanco, Kenneth P. Ishida, Megan H. Plumlee, Michael Boyd, Erik Desormeaux, Graham J. G. Juby, Mojtaba Farrokh Shad

    Closed circuit reverse osmosis (CCRO) and forward osmosis-RO (FO-RO) were evaluated at a pilot scale to generate additional permeate from RO concentrate – achieving a recovery of 61% for CCRO and 35% for FO-RO – at a full-scale advanced water purification facility. This study assessed permeate water quality, suitability of the permeate for treatment by an ultraviolet-advanced oxidation process (UV-AOP), and cost/footprint for a conceptual 10- or 20-mgd system. Both technologies demonstrated inorganic, organic, and microbiological constituent removal suitable for blending with primary RO permeate. Virus challenge testing with MS coliphage demonstrated ≥3.7-log removal by both technologies. Pilot-scale UV/hydrogen peroxide AOP treatment of CCRO or FO-RO permeate yielded similar performance (∼1.4-log N-nitrosodimethylamine removal and ∼0.5-log 1,4-dioxane removal) as the full-scale UV-AOP that treats the RO permeate from the purification facility. The estimated full-scale total unit cost (capital plus operation and maintenance costs) of product water produced by the two technologies was estimated to range from $0.91 to $1.12 per cubic meter, depending on the design flow rate of RO concentrate treated, and is estimated to be similar between the two technologies given the +50%/–30% expected accuracy of the Class 5 cost estimate.


  • Open Access

    Comparing PFAS removal across multiple groundwaters for eight GACs and alternative adsorbent

    by Manmeet W. Pannu, Joseph Chang, Ricardo Medina, Scott A. Grieco, Michael Hwang, Megan H. Plumlee

    Eight granular activated carbons (GACs) and one alternative adsorbent (AA) were evaluated using rapid small‐scale column tests (RSSCTs) to remove low level per‐ and polyfluoroalkyl substances (PFAS) from several groundwaters. Results suggested variability among waters for adsorbents to reach breakthrough. Time to reach breakthrough appeared to be inversely proportional to the background dissolved organic carbon (DOC). Bituminous GACs (particularly F400 and UC1240LD) were more effective than non‐bituminous. The elution order for PFAS was PFHxA (C6) > PFBS (C4) > PFOA (C8) > PFHxS (C6) > PFOS (C8). Multivariate regression predicted bed volumes at which F400 reached significant exhaustion (defined here as 60%) for PFOA using only two parameters (humic acid, DOC). This merits further study as these parameters could potentially be incorporated into models for predicting PFAS breakthrough. VOCs presence negatively impacted PFAS adsorption on GAC. Relative to GACs, the AA was not nearly as impacted by DOC and showed superior performance.


  • Open Access

    SARS-CoV-2 genetic material is removed during municipal wastewater treatment and is undetectable after advanced treatment

    by Julio A. Polanco, Bradley Schmitz, Samuel Choi, Jana Safarik, Sarah Prasek, Megan H. Plumlee


  • Pilot‐scale comparison of granular activated carbons, ion exchange, and alternative adsorbents for per‐ and polyfluoroalkyl substances removal

    by Ricardo Medina, Manmeet W. Pannu, Scott A. Grieco, Michael Hwang, Christine Pham, Megan H. Plumlee

    Eight granular activated carbons (GAC), four anion exchange (IX) resins, and two alternative adsorbents (AAs) were tested for the removal of per‐ and polyfluoroalkyl substances (PFAS) from a groundwater source used for drinking water. The study was conducted using pilot(meter)‐scale columns operated in continuous‐flow mode for 16–26 months. Comparison between GAC adsorbents showed that bituminous GACs exhibited higher adsorption than non‐/sub‐bituminous GACs. Testing of a reactivated and new GAC showed no significant differences with respect to PFAS adsorption. Of the four IX resins tested, one resin showed superior adsorption when compared with all three IX resins. A surface‐modified bentonite adsorbent showed superior removal efficiencies over all adsorbent types tested here. These results provide benchmark performance and adsorption capacities at pilot‐scale for various adsorbents and highlight the promise of AAs to remove PFAS from water sources with low (ng/L) concentrations.


  • Open Access

    Correction: Validation of a novel direct-injection chemiluminescence-based method for N -nitrosamine analysis in advanced-treated recycled water, drinking water, and wastewater

    by Shannon L. Roback, Hitoshi Kodamatani, Takahiro Fujioka, Megan H. Plumlee

    Correction for ‘Validation of a novel direct-injection chemiluminescence-based method for N -nitrosamine analysis in advanced-treated recycled water, drinking water, and wastewater’ by Shannon L. Roback et al. , Environ. Sci.: Water Res. Technol. , 2020, 6 , 1106–1115, DOI: 10.1039/C9EW00943D.