GHGhulam Hussain

Ghulam Hussain

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ghulam Hussain has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Gulfam Nasar

    Department of Chemistry, BUITEMS, Quetta, Pakistan

    1 shared publication
  • H M Noor Ul Huda Khan Asghar

    Department of Physics, Balochistan University of Information Technology, Engineering & Management Sciences (BUITEMS), Quetta, Pakistan

    1 shared publication
  • Jalil Ur Rehman

    Department of Physics, Balochistan University of Information Technology, Engineering & Management Sciences, Quetta, Pakistan

    1 shared publication
  • Malik M Akhter

    Department of Environmental Science, BUITEMS, Quetta, Pakistan

    1 shared publication
  • Muhammad Isa

    Department of Physics, Hafiz Hayat Campus University of Gujrat, Gujrat, Pakistan

    1 shared publication
  • Nisar Ahmad

    Department of Physics, Balochistan University of Information Technology, Engineering and Management Sciences

    1 shared publication

Latest Publications

  • Dose verification of volumetric-modulated arc therapy using one-dimensional and two-dimensional dosimeters

    by Jalil Ur Rehman, Zahra Syed, Ghulam Hussain, Nisar Ahmad, H M Noor Ul Huda Khan Asghar, Zaheer Abbas Gilani, Gulfam Nasar, Malik M Akhter, Muhammad Isa, Tahir Iqbal

    PurposeTo verify dose delivery and quality assurance of volumetric-modulated arc therapy (VMAT) for head and neck (H&N) cancer.MethodThe Imaging and Radiation Oncology Core Houston (IROC-H) H&N phantom with thermoluminescent dosimeters (TLDs) and films, were imaged with computed tomography scan and the reconstructed image was transferred to pinnacle treatment planning system (TPS). On TPS, the planning target volume (PTV), secondary target volume (STV) and organ at risk (OAR) were delineated manually and a treatment plan was made. The dose constraints were determined for the concerned organs according to IROC-H prescription. The treatment plan was optimised using adoptive convolution algorithm to improve dose homogeneity and conformity. The dose calculation was performed using C.C Convolution algorithm and a Varian True Beam linear accelerator was used to deliver the treatment plan to the H&N phantom. The delivered radiation dose to the phantom was measured through TLDs and GafChromic external beam radiotherapy 2 (EBT2) films. The dosimetric performance of the VMAT delivery was studied by analysing percent dose difference, isodose line profile and gamma analysis of the TPS-computed dose and linac-delivered doses.ResultThe percent dose difference of 3.8% was observed between the planned and measured doses of TLDs and a 1.5-mm distance to agreement (DTA) was observed by comparing isodose line profiles. Passed the gamma criteria of 3%/3 mm was with good percentages.ConclusionThe dosimetric performance of VMAT delivery for a challenging H&N radiotherapy can be verified using TLDs and films embedded in an anthropomorphic H&N phantom.