Justin Hanenberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Justin Hanenberg has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Conchita Chua
Memorial Sloan-Kettering Cancer Center, New York, NY
1 shared publicationJean Lynch
Memorial Sloan-Kettering Cancer Center, New York, NY
1 shared publicationJingqui Yao
Memorial Sloan-Kettering Cancer Center, New York, NY
1 shared publicationJosephine Rafael
Memorial Sloan-Kettering Cancer Center, New York, NY
1 shared publication- Nenita Francisco
Memorial Sloan-Kettering Cancer Center, New York, NY
1 shared publication - Peter Maslak
Memorial Sloan Kettering Cancer Center, New York, NY
1 shared publication
Latest Publications
- 5 June 2014
- Published by American Society of Hematology in Blood
- Vol. 123 (23) , 3541
Cytospin preparation of AML in pleural fluid
- 5 June 2014
- Published by American Society of Hematology in Blood
- Vol. 123 (23) , 3541
Cytospin preparation of AML in pleural fluid
- Open Access
- 1 November 2013
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 140 (5) , 747-754
Comparison of Automated Platelet Counts and Potential Effect on Transfusion Decisions in Cancer Patients
Objectives: To evaluate the accuracy of platelet counts from various hematology analyzers using a reference immunologic method. Methods: We tested 403 samples with platelet counts less than 50 × 109/L with the Advia (Siemens, Tarrytown, NY), Sysmex (Mundelein, IL), and Abbott (Santa Clara, CA) analyzers. Results: All methods showed a positive bias, especially at less than 20 × 109/L and less than 10 × 109/L. Undertransfusion risk ranged from 9.1% to 43.3 % in the groups below 20 × 109/L and below 10 × 109/L, respectively. For patients with optical counts more than 10 × 109/L and CD61 less than 10 × 109/L, 64.5% were transfused within 24 hours of the reported count, while 35.5% were transfused in more than 24 hours, after a subsequent optical platelet count of 10 × 109/L or less was reported. Conclusions: Although optical and impedance methods were shown to be falsely increased in severely thrombocytopenic samples, further studies are needed to determine if more accurate methods would be clinically useful.
- 1 November 2013
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 140 (5) , 747-754
Open AccessComparison of Automated Platelet Counts and Potential Effect on Transfusion Decisions in Cancer Patients
Objectives: To evaluate the accuracy of platelet counts from various hematology analyzers using a reference immunologic method. Methods: We tested 403 samples with platelet counts less than 50 × 109/L with the Advia (Siemens, Tarrytown, NY), Sysmex (Mundelein, IL), and Abbott (Santa Clara, CA) analyzers. Results: All methods showed a positive bias, especially at less than 20 × 109/L and less than 10 × 109/L. Undertransfusion risk ranged from 9.1% to 43.3 % in the groups below 20 × 109/L and below 10 × 109/L, respectively. For patients with optical counts more than 10 × 109/L and CD61 less than 10 × 109/L, 64.5% were transfused within 24 hours of the reported count, while 35.5% were transfused in more than 24 hours, after a subsequent optical platelet count of 10 × 109/L or less was reported. Conclusions: Although optical and impedance methods were shown to be falsely increased in severely thrombocytopenic samples, further studies are needed to determine if more accurate methods would be clinically useful.