Antonio Giuseppe Amico
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Antonio Giuseppe Amico has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Bettinelli
Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy
3 shared publications - Samuele Cavinato
Medical Physics Department, Veneto Institute of Oncology IOV-IRCCS, 35128 Padova, Italy
3 shared publications - Alessandro Scaggion
Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy
2 shared publications - Badr El Khouzai
Radiation Oncology Department, Veneto Institute of Oncology IOV-IRCCS, 35128 Padova, Italy
2 shared publications - Federica Guida
Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy
2 shared publications - Giada Petringa
INFN Laboratori Nazionali del Sud, via S.Sofia 62, 95123 Catania, Italy
2 shared publications
Latest Publications
- Open Access
Characterization of Plan Complexity and Its Role in Quality Assurance for AI-Assisted CBCT-Based Online Adaptive Radiotherapy of Prostate Cancer
Background/Objectives: Online adaptive radiotherapy (oART) generates plans at each fraction by exploiting AI-assisted optimization engines without explicit user control over modulation. This process challenges quality assurance since measurement-based Patient Specific Quality Assurance (PSQA) cannot be performed daily. This study aimed: (i) to characterize plan complexity in IOE-generated plans for prostate cancer using a reproducible set of PCMs, including the decomposition of inter-patient and intra-patient variability sources; (ii) to evaluate the association between PCMs and delivery accuracy within a cohort-informed SPC framework validated through leave-one-patient-out cross-validation; (iii) to investigate whether inter-fraction anatomical variations explain the observed plan complexity patterns, or whether complexity is predominantly an intrinsic signature of the AI-assisted optimizer. Methods: Twenty-one prostate cancer patients treated on a CBCT-based oART platform were retrospectively analyzed across three anatomical targets: prostatic bed (PrB), prostate (Pr), and prostate with seminal vesicles (PrSV). Six PCMs, namely MU/cGy, Modulation Complexity Score (MCS), Aperture Area Variability (AAV), Leaf Sequence Variability (LSV), Average Leaf Gap (ALG) and Plan Irregularity, were extracted. Additionally, five anatomical metrics (AMs) were computed from daily contours. Linear mixed-effects models (LMEMs) compared reference/online plans, decomposed variance via intraclass correlation coefficients (ICCs), and assessed PCM–gamma passing rate (GPR) associations. Leave-one-patient-out cross-validation (LOPO-CV) evaluated SPC threshold stability. The relationships between PCMs and AMs were investigated using LMEMs. Results: The AI-assisted optimization engine generated plans characterized by elevated monitor unit demand (average MU/cGy ≥ 6.8 ± 0.9) and narrow MLC apertures (ALG ≤ 17.7 mm ± 1.9 mm). No complexity differences emerged between offline and online-adapted plans, nor between anatomical targets. All PCMs showed significant associations with global GPR (p ≤ 0.027), though marginal R2 remained low (≤0.122). Notably, GPR dispersion increased systematically at higher complexity values, indicating that highly modulated plans exhibit reduced delivery predictability. LOPO-CV demonstrated stable tolerance/action limits. Anatomical variations explained less than 35% of the total variance in PCMs. Conclusions: Plan complexity in oART reflects the optimization paradigm and patient-specific anatomy rather than daily adaptation. PCMs can serve as surveillance indicators flagging high-risk fractions to support SPC-based monitoring.
Open AccessCharacterization of Plan Complexity and Its Role in Quality Assurance for AI-Assisted CBCT-Based Online Adaptive Radiotherapy of Prostate Cancer
Background/Objectives: Online adaptive radiotherapy (oART) generates plans at each fraction by exploiting AI-assisted optimization engines without explicit user control over modulation. This process challenges quality assurance since measurement-based Patient Specific Quality Assurance (PSQA) cannot be performed daily. This study aimed: (i) to characterize plan complexity in IOE-generated plans for prostate cancer using a reproducible set of PCMs, including the decomposition of inter-patient and intra-patient variability sources; (ii) to evaluate the association between PCMs and delivery accuracy within a cohort-informed SPC framework validated through leave-one-patient-out cross-validation; (iii) to investigate whether inter-fraction anatomical variations explain the observed plan complexity patterns, or whether complexity is predominantly an intrinsic signature of the AI-assisted optimizer. Methods: Twenty-one prostate cancer patients treated on a CBCT-based oART platform were retrospectively analyzed across three anatomical targets: prostatic bed (PrB), prostate (Pr), and prostate with seminal vesicles (PrSV). Six PCMs, namely MU/cGy, Modulation Complexity Score (MCS), Aperture Area Variability (AAV), Leaf Sequence Variability (LSV), Average Leaf Gap (ALG) and Plan Irregularity, were extracted. Additionally, five anatomical metrics (AMs) were computed from daily contours. Linear mixed-effects models (LMEMs) compared reference/online plans, decomposed variance via intraclass correlation coefficients (ICCs), and assessed PCM–gamma passing rate (GPR) associations. Leave-one-patient-out cross-validation (LOPO-CV) evaluated SPC threshold stability. The relationships between PCMs and AMs were investigated using LMEMs. Results: The AI-assisted optimization engine generated plans characterized by elevated monitor unit demand (average MU/cGy ≥ 6.8 ± 0.9) and narrow MLC apertures (ALG ≤ 17.7 mm ± 1.9 mm). No complexity differences emerged between offline and online-adapted plans, nor between anatomical targets. All PCMs showed significant associations with global GPR (p ≤ 0.027), though marginal R2 remained low (≤0.122). Notably, GPR dispersion increased systematically at higher complexity values, indicating that highly modulated plans exhibit reduced delivery predictability. LOPO-CV demonstrated stable tolerance/action limits. Anatomical variations explained less than 35% of the total variance in PCMs. Conclusions: Plan complexity in oART reflects the optimization paradigm and patient-specific anatomy rather than daily adaptation. PCMs can serve as surveillance indicators flagging high-risk fractions to support SPC-based monitoring.
- Open Access
- 22 November 2025
- Published by Elsevier in Physica Medica
- Vol. 140, 105677
Bladder surface-based analysis proves the advantages of online adaptive radiotherapy over plan of the day
- 22 November 2025
- Published by Elsevier in Physica Medica
- Vol. 140, 105677
Open AccessBladder surface-based analysis proves the advantages of online adaptive radiotherapy over plan of the day
- Open Access
- 20 June 2025
- Published by Elsevier in Physica Medica
- Vol. 136, 105026
Exploring plan quality: using plan complexity to quantitatively analyse the tradeoff between clinical suitability and dosimetric accuracy
- 20 June 2025
- Published by Elsevier in Physica Medica
- Vol. 136, 105026
Open AccessExploring plan quality: using plan complexity to quantitatively analyse the tradeoff between clinical suitability and dosimetric accuracy
- 1 August 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (8) , 083303
A new energy spectrum reconstruction method for time-of-flight diagnostics of high-energy laser-driven protons
The Time-of-Flight (TOF) technique coupled with semiconductorlike detectors, as silicon carbide and diamond, is one of the most promising diagnostic methods for high-energy, high repetition rate, laser-accelerated ions allowing a full on-line beam spectral characterization. A new analysis method for reconstructing the energy spectrum of high-energy laser-driven ion beams from TOF signals is hereby presented and discussed. The proposed method takes into account the detector’s working principle, through the accurate calculation of the energy loss in the detector active layer, using Monte Carlo simulations. The analysis method was validated against well-established diagnostics, such as the Thomson parabola spectrometer, during an experimental campaign carried out at the Rutherford Appleton Laboratory (UK) with the high-energy laser-driven protons accelerated by the VULCAN Petawatt laser.
- 1 August 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (8) , 083303
A new energy spectrum reconstruction method for time-of-flight diagnostics of high-energy laser-driven protons
The Time-of-Flight (TOF) technique coupled with semiconductorlike detectors, as silicon carbide and diamond, is one of the most promising diagnostic methods for high-energy, high repetition rate, laser-accelerated ions allowing a full on-line beam spectral characterization. A new analysis method for reconstructing the energy spectrum of high-energy laser-driven ion beams from TOF signals is hereby presented and discussed. The proposed method takes into account the detector’s working principle, through the accurate calculation of the energy loss in the detector active layer, using Monte Carlo simulations. The analysis method was validated against well-established diagnostics, such as the Thomson parabola spectrometer, during an experimental campaign carried out at the Rutherford Appleton Laboratory (UK) with the high-energy laser-driven protons accelerated by the VULCAN Petawatt laser.
- Open Access
- 19 September 2017
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 7, 223
Clinical and Research Activities at the CATANA Facility of INFN-LNS: From the Conventional Hadrontherapy to the Laser-Driven Approach
The CATANA protontherapy center was the first Italian clinical facility making use of energetic (62 MeV) proton beams for the radiative treatment of solid tumours. Since the date of the first patient treatment in 2002, 400 patients have been successful treated whose majority was affected by choroidal and iris melanomas. In this paper we report on the actual clinical and physical status of the CATANA facility describing the last dosimetric studies and reporting on the last patient follow-up results. The last part of the paper is dedicated to the description of the INFN ongoing activities on the realisation of a beamline for the transport of laser-accelerated ion beams. The ELIMED (ELI-BEamlines MEDical and multidisciplinary applications) project is intruded and its main scientific aspects described.
- 19 September 2017
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 7, 223
Open AccessClinical and Research Activities at the CATANA Facility of INFN-LNS: From the Conventional Hadrontherapy to the Laser-Driven Approach
The CATANA protontherapy center was the first Italian clinical facility making use of energetic (62 MeV) proton beams for the radiative treatment of solid tumours. Since the date of the first patient treatment in 2002, 400 patients have been successful treated whose majority was affected by choroidal and iris melanomas. In this paper we report on the actual clinical and physical status of the CATANA facility describing the last dosimetric studies and reporting on the last patient follow-up results. The last part of the paper is dedicated to the description of the INFN ongoing activities on the realisation of a beamline for the transport of laser-accelerated ion beams. The ELIMED (ELI-BEamlines MEDical and multidisciplinary applications) project is intruded and its main scientific aspects described.