Samuele Cavinato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Samuele Cavinato has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Scaggion
Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy
6 shared publications - Marta Paiusco
Medical Physics Department, Veneto Institute of Oncology IOV-IRCCS, via Gattamelata 64, 35128 Padova, Italy
6 shared publications - Andrea Bettinelli
Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy
4 shared publications - Antonio Giuseppe Amico
Medical Physics Department, Veneto Institute of Oncology IOV-IRCCS, 35128 Padova, Italy
3 shared publications - Federica Guida
Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy
3 shared publications - Sonia Sapignoli
Medical Physics Department, Veneto Institute of Oncology IOV-IRCCS, 35128 Padova, Italy
3 shared publications
Latest Publications
- Open Access
- 11 May 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 220, 111587
Resource sharing and open-source software in radiation oncology: From challenges to opportunities for community-wide benefit
- 11 May 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 220, 111587
Open AccessResource sharing and open-source software in radiation oncology: From challenges to opportunities for community-wide benefit
- Open Access
Characterization of Plan Complexity and Its Role in Quality Assurance for AI-Assisted CBCT-Based Online Adaptive Radiotherapy of Prostate Cancer
Background/Objectives: Online adaptive radiotherapy (oART) generates plans at each fraction by exploiting AI-assisted optimization engines without explicit user control over modulation. This process challenges quality assurance since measurement-based Patient Specific Quality Assurance (PSQA) cannot be performed daily. This study aimed: (i) to characterize plan complexity in IOE-generated plans for prostate cancer using a reproducible set of PCMs, including the decomposition of inter-patient and intra-patient variability sources; (ii) to evaluate the association between PCMs and delivery accuracy within a cohort-informed SPC framework validated through leave-one-patient-out cross-validation; (iii) to investigate whether inter-fraction anatomical variations explain the observed plan complexity patterns, or whether complexity is predominantly an intrinsic signature of the AI-assisted optimizer. Methods: Twenty-one prostate cancer patients treated on a CBCT-based oART platform were retrospectively analyzed across three anatomical targets: prostatic bed (PrB), prostate (Pr), and prostate with seminal vesicles (PrSV). Six PCMs, namely MU/cGy, Modulation Complexity Score (MCS), Aperture Area Variability (AAV), Leaf Sequence Variability (LSV), Average Leaf Gap (ALG) and Plan Irregularity, were extracted. Additionally, five anatomical metrics (AMs) were computed from daily contours. Linear mixed-effects models (LMEMs) compared reference/online plans, decomposed variance via intraclass correlation coefficients (ICCs), and assessed PCM–gamma passing rate (GPR) associations. Leave-one-patient-out cross-validation (LOPO-CV) evaluated SPC threshold stability. The relationships between PCMs and AMs were investigated using LMEMs. Results: The AI-assisted optimization engine generated plans characterized by elevated monitor unit demand (average MU/cGy ≥ 6.8 ± 0.9) and narrow MLC apertures (ALG ≤ 17.7 mm ± 1.9 mm). No complexity differences emerged between offline and online-adapted plans, nor between anatomical targets. All PCMs showed significant associations with global GPR (p ≤ 0.027), though marginal R2 remained low (≤0.122). Notably, GPR dispersion increased systematically at higher complexity values, indicating that highly modulated plans exhibit reduced delivery predictability. LOPO-CV demonstrated stable tolerance/action limits. Anatomical variations explained less than 35% of the total variance in PCMs. Conclusions: Plan complexity in oART reflects the optimization paradigm and patient-specific anatomy rather than daily adaptation. PCMs can serve as surveillance indicators flagging high-risk fractions to support SPC-based monitoring.
Open AccessCharacterization of Plan Complexity and Its Role in Quality Assurance for AI-Assisted CBCT-Based Online Adaptive Radiotherapy of Prostate Cancer
Background/Objectives: Online adaptive radiotherapy (oART) generates plans at each fraction by exploiting AI-assisted optimization engines without explicit user control over modulation. This process challenges quality assurance since measurement-based Patient Specific Quality Assurance (PSQA) cannot be performed daily. This study aimed: (i) to characterize plan complexity in IOE-generated plans for prostate cancer using a reproducible set of PCMs, including the decomposition of inter-patient and intra-patient variability sources; (ii) to evaluate the association between PCMs and delivery accuracy within a cohort-informed SPC framework validated through leave-one-patient-out cross-validation; (iii) to investigate whether inter-fraction anatomical variations explain the observed plan complexity patterns, or whether complexity is predominantly an intrinsic signature of the AI-assisted optimizer. Methods: Twenty-one prostate cancer patients treated on a CBCT-based oART platform were retrospectively analyzed across three anatomical targets: prostatic bed (PrB), prostate (Pr), and prostate with seminal vesicles (PrSV). Six PCMs, namely MU/cGy, Modulation Complexity Score (MCS), Aperture Area Variability (AAV), Leaf Sequence Variability (LSV), Average Leaf Gap (ALG) and Plan Irregularity, were extracted. Additionally, five anatomical metrics (AMs) were computed from daily contours. Linear mixed-effects models (LMEMs) compared reference/online plans, decomposed variance via intraclass correlation coefficients (ICCs), and assessed PCM–gamma passing rate (GPR) associations. Leave-one-patient-out cross-validation (LOPO-CV) evaluated SPC threshold stability. The relationships between PCMs and AMs were investigated using LMEMs. Results: The AI-assisted optimization engine generated plans characterized by elevated monitor unit demand (average MU/cGy ≥ 6.8 ± 0.9) and narrow MLC apertures (ALG ≤ 17.7 mm ± 1.9 mm). No complexity differences emerged between offline and online-adapted plans, nor between anatomical targets. All PCMs showed significant associations with global GPR (p ≤ 0.027), though marginal R2 remained low (≤0.122). Notably, GPR dispersion increased systematically at higher complexity values, indicating that highly modulated plans exhibit reduced delivery predictability. LOPO-CV demonstrated stable tolerance/action limits. Anatomical variations explained less than 35% of the total variance in PCMs. Conclusions: Plan complexity in oART reflects the optimization paradigm and patient-specific anatomy rather than daily adaptation. PCMs can serve as surveillance indicators flagging high-risk fractions to support SPC-based monitoring.
- Open Access
- 22 November 2025
- Published by Elsevier in Physica Medica
- Vol. 140, 105677
Bladder surface-based analysis proves the advantages of online adaptive radiotherapy over plan of the day
- 22 November 2025
- Published by Elsevier in Physica Medica
- Vol. 140, 105677
Open AccessBladder surface-based analysis proves the advantages of online adaptive radiotherapy over plan of the day
- Open Access
- 20 June 2025
- Published by Elsevier in Physica Medica
- Vol. 136, 105026
Exploring plan quality: using plan complexity to quantitatively analyse the tradeoff between clinical suitability and dosimetric accuracy
- 20 June 2025
- Published by Elsevier in Physica Medica
- Vol. 136, 105026
Open AccessExploring plan quality: using plan complexity to quantitatively analyse the tradeoff between clinical suitability and dosimetric accuracy
- Open Access
- 2 May 2024
- Published by Elsevier in Physica Medica
- Vol. 121, 103364
On the necessity of specialized knowledge-based models for SBRT prostate treatments plans
- 2 May 2024
- Published by Elsevier in Physica Medica
- Vol. 121, 103364
Open AccessOn the necessity of specialized knowledge-based models for SBRT prostate treatments plans
- 8 November 2023
- Published by Elsevier in Physica Medica
- Vol. 115, 102714
A MULTICENTRIC COOPERATIVE EFFORT ON A SHARED CLOUD-BASED PLATFORM FOR PEDIATRIC RADIOTHERAPY QA
- 8 November 2023
- Published by Elsevier in Physica Medica
- Vol. 115, 102714
A MULTICENTRIC COOPERATIVE EFFORT ON A SHARED CLOUD-BASED PLATFORM FOR PEDIATRIC RADIOTHERAPY QA
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S1426-S1428
PO-1712 Quality Assurance of Pediatric Radiotherapy: a KBP multicentric cooperative initiative
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S1426-S1428
PO-1712 Quality Assurance of Pediatric Radiotherapy: a KBP multicentric cooperative initiative
- Open Access
- 28 March 2023
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 26, 100435
Prediction models as decision-support tools for virtual patient-specific quality assurance of helical tomotherapy plans
- 28 March 2023
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 26, 100435
Open AccessPrediction models as decision-support tools for virtual patient-specific quality assurance of helical tomotherapy plans
- 4 November 2021
- Published by American Physical Society (APS) in Physical Review D
- Vol. 104 (9) , 096004
Quantum algorithm for the classification of supersymmetric top quark events
The search for supersymmetric particles is one of the major goals of the Large Hadron Collider (LHC). Supersymmetric top (stop) searches play a very important role in this respect, but the unprecedented collision rate to be attained at the next high luminosity phase of the LHC poses new challenges for the separation between any new signal and the standard model background. The massive parallelism provided by quantum computing techniques may yield an efficient solution for this problem. In this paper we show a novel application of the zoomed quantum annealing machine learning approach to classify the stop signal versus the background, and implement it in a quantum annealer machine. We show that this approach together with the preprocessing of the data with principal component analysis may yield better results than conventional multivariate approaches.
- 4 November 2021
- Published by American Physical Society (APS) in Physical Review D
- Vol. 104 (9) , 096004
Quantum algorithm for the classification of supersymmetric top quark events
The search for supersymmetric particles is one of the major goals of the Large Hadron Collider (LHC). Supersymmetric top (stop) searches play a very important role in this respect, but the unprecedented collision rate to be attained at the next high luminosity phase of the LHC poses new challenges for the separation between any new signal and the standard model background. The massive parallelism provided by quantum computing techniques may yield an efficient solution for this problem. In this paper we show a novel application of the zoomed quantum annealing machine learning approach to classify the stop signal versus the background, and implement it in a quantum annealer machine. We show that this approach together with the preprocessing of the data with principal component analysis may yield better results than conventional multivariate approaches.
- 17 May 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (12) , 125015
Optimizing radiotherapy plans for cancer treatment with Tensor Networks
We present a novel application of Tensor Network methods in cancer treatment as a potential tool to solve the dose optimization problem in radiotherapy. In particular, the Intensity-Modulated Radiation Therapy (IMRT) technique -- that allows treating irregular and inhomogeneous tumors while reducing the radiation toxicity on healthy organs -- is based on the optimization problem of the beamlets intensities that shall result in a maximal delivery of the therapy dose to cancer while avoiding the organs at risk of being damaged by the radiation. The resulting optimization problem is expressed as a cost function to be optimized. Here, we map the cost function into an Ising-like Hamiltonian, describing a system of long-range interacting Qubits. Finally, we solve the dose optimization problem by finding the ground-state of the Hamiltonian using a Tree Tensor Network algorithm. In particular, we present an anatomical scenario exemplifying a prostate cancer treatment. A similar approach can be applied to future hybrid classical-quantum algorithms, paving the way for the use of quantum technologies in future medical treatments.
- 17 May 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (12) , 125015
Optimizing radiotherapy plans for cancer treatment with Tensor Networks
We present a novel application of Tensor Network methods in cancer treatment as a potential tool to solve the dose optimization problem in radiotherapy. In particular, the Intensity-Modulated Radiation Therapy (IMRT) technique -- that allows treating irregular and inhomogeneous tumors while reducing the radiation toxicity on healthy organs -- is based on the optimization problem of the beamlets intensities that shall result in a maximal delivery of the therapy dose to cancer while avoiding the organs at risk of being damaged by the radiation. The resulting optimization problem is expressed as a cost function to be optimized. Here, we map the cost function into an Ising-like Hamiltonian, describing a system of long-range interacting Qubits. Finally, we solve the dose optimization problem by finding the ground-state of the Hamiltonian using a Tree Tensor Network algorithm. In particular, we present an anatomical scenario exemplifying a prostate cancer treatment. A similar approach can be applied to future hybrid classical-quantum algorithms, paving the way for the use of quantum technologies in future medical treatments.