Timothy Charles Cope
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Timothy Charles Cope has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
Paul Nardelli
School of Biological Sciences Georgia Institute of Technology Atlanta Georgia USA
14 shared publications- Stephen Nicholas Housley
School of Biological Sciences, Georgia Institute of Technology, Atlanta, USA
11 shared publications - Lena H. Ting
Wallace H. Coulter Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, GA, USA
6 shared publications Stephen N. Housley
School of Biological Sciences, Georgia Institute of Technology, Atlanta, Georgia, UNITED STATES
4 shared publicationsTravis M. Rotterman
School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, United States
4 shared publicationsDario I. Carrasco
School of Biological Sciences, Georgia Institute of Technology, Atlanta, 30332, Georgia
3 shared publications
Latest Publications
- Open Access
- 15 November 2026
- Published by The Company of Biologists in Journal of Experimental Biology
- Vol. 229 (22)
Emulating the influence of exoskeleton stiffness on primary afferent feedback in rat isolated muscle–tendon unit
Exoskeletons assist and augment movement, but their effects on proprioceptive feedback remain poorly understood because of challenges in making direct measures of sensory signals in humans. Here, we leveraged an animal model to explore how mechanical context akin to an elastic exoskeleton operating on a human lower limb joint influences primary muscle spindle firing. In an anesthetized rat preparation, we applied controlled stretches to the medial gastrocnemius with engineered springs (0–0.5 N mm−1) in parallel to the muscle–tendon unit (MTU) while modulating muscle activation to maintain overall system stiffness. Fascicle length was measured with sonomicrometry, force and MTU length with a servo motor, and spindle instantaneous firing rate (IFR) using dorsal root recordings. Trading off increases in exoskeleton stiffness with reductions in muscle activation decreased biological muscle force (3.1±0.6 N to 1.6±0.6 N, P<0.001) and stiffness (4.4±1.5 N mm−1 to 2.3±1.3 N mm−1, P<0.01), and increased fascicle length (7.9±1.3 mm to 8.3±1.5 mm, P<0.005). We found significant correlations between spindle firing and each independent fascicle dynamics factor we investigated (P<0.005). Thus, parallel stiffness modified muscle fascicle dynamics but did not alter spindle firing, possibly due to internal trade-offs in the salient fascicle dynamics that drive spindle behavior. Leveraging in situ experiments that enable monitoring of afferent feedback in complex mechanical contexts such as added parallel stiffness can provide a window into the effects of wearable devices on underlying sensory systems.
- 15 November 2026
- Published by The Company of Biologists in Journal of Experimental Biology
- Vol. 229 (22)
Open AccessEmulating the influence of exoskeleton stiffness on primary afferent feedback in rat isolated muscle–tendon unit
Exoskeletons assist and augment movement, but their effects on proprioceptive feedback remain poorly understood because of challenges in making direct measures of sensory signals in humans. Here, we leveraged an animal model to explore how mechanical context akin to an elastic exoskeleton operating on a human lower limb joint influences primary muscle spindle firing. In an anesthetized rat preparation, we applied controlled stretches to the medial gastrocnemius with engineered springs (0–0.5 N mm−1) in parallel to the muscle–tendon unit (MTU) while modulating muscle activation to maintain overall system stiffness. Fascicle length was measured with sonomicrometry, force and MTU length with a servo motor, and spindle instantaneous firing rate (IFR) using dorsal root recordings. Trading off increases in exoskeleton stiffness with reductions in muscle activation decreased biological muscle force (3.1±0.6 N to 1.6±0.6 N, P<0.001) and stiffness (4.4±1.5 N mm−1 to 2.3±1.3 N mm−1, P<0.01), and increased fascicle length (7.9±1.3 mm to 8.3±1.5 mm, P<0.005). We found significant correlations between spindle firing and each independent fascicle dynamics factor we investigated (P<0.005). Thus, parallel stiffness modified muscle fascicle dynamics but did not alter spindle firing, possibly due to internal trade-offs in the salient fascicle dynamics that drive spindle behavior. Leveraging in situ experiments that enable monitoring of afferent feedback in complex mechanical contexts such as added parallel stiffness can provide a window into the effects of wearable devices on underlying sensory systems.
- Open Access
Oxaliplatin Induces Spontaneous Firing at Sensory Endings Across Touch and Proprioceptive Afferents
Spontaneous activity in primary sensory neurons has been implicated in neuropathic symptoms, yet its earliest origins and immediate functional consequences remain incompletely understood. This gap is especially consequential in chemotherapy-induced peripheral neuropathy (CIPN), where sensory toxicities commonly limit effective cancer treatment. Using in vivo recordings in rats, we show that a single dose of oxaliplatin (OX) induces spontaneous firing within 24 h across touch and proprioceptive low-threshold mechanoreceptor (LTMR) afferents. Spontaneous firing consistently originated distally in peripheral axons and was accompanied by enhanced responses to mechanical stimulation, identifying LTMR sensory endings as the earliest source of spontaneous firing and a common site for spontaneous and stimulus-evoked hyperexcitability. OX also induced early structural abnormalities at sensory endings; however, SF+ LTMRs retained mechanosensory response profiles, indicating that spontaneous firing can emerge within otherwise functional sensory endings. Although coincident spontaneous and stimulus-evoked activity distorted encoding in individual LTMRs, these effects had little impact on population LTMR responses or motor behavior relying on mechanosensory feedback. Together, these findings identify sensory endings as an early target of OX neurotoxicity and demonstrate that spontaneous firing spanning multiple tactile and proprioceptive LTMR submodalities can coexist with largely preserved sensory function, indicating that even broad engagement across mechanosensory pathways is insufficient to disrupt all LTMR-dependent functions. These observations indicate that abnormal afferent activity initiated at sensory endings may be sufficient to engage sensory pathways underlying some paresthetic symptoms while leaving others largely unaffected, whereas progression to chronic neuropathic symptoms may require subsequent recruitment of the dorsal root ganglion. Highlights: Oxaliplatin rapidly induces spontaneous firing across touch and proprioceptors. The earliest spontaneous firing localizes to sensory endings, not the DRG. Sensory endings are a shared site of spontaneous and evoked hyperexcitability. Spontaneous firing engages some sensory pathways while sparing others.
Open AccessOxaliplatin Induces Spontaneous Firing at Sensory Endings Across Touch and Proprioceptive Afferents
Spontaneous activity in primary sensory neurons has been implicated in neuropathic symptoms, yet its earliest origins and immediate functional consequences remain incompletely understood. This gap is especially consequential in chemotherapy-induced peripheral neuropathy (CIPN), where sensory toxicities commonly limit effective cancer treatment. Using in vivo recordings in rats, we show that a single dose of oxaliplatin (OX) induces spontaneous firing within 24 h across touch and proprioceptive low-threshold mechanoreceptor (LTMR) afferents. Spontaneous firing consistently originated distally in peripheral axons and was accompanied by enhanced responses to mechanical stimulation, identifying LTMR sensory endings as the earliest source of spontaneous firing and a common site for spontaneous and stimulus-evoked hyperexcitability. OX also induced early structural abnormalities at sensory endings; however, SF+ LTMRs retained mechanosensory response profiles, indicating that spontaneous firing can emerge within otherwise functional sensory endings. Although coincident spontaneous and stimulus-evoked activity distorted encoding in individual LTMRs, these effects had little impact on population LTMR responses or motor behavior relying on mechanosensory feedback. Together, these findings identify sensory endings as an early target of OX neurotoxicity and demonstrate that spontaneous firing spanning multiple tactile and proprioceptive LTMR submodalities can coexist with largely preserved sensory function, indicating that even broad engagement across mechanosensory pathways is insufficient to disrupt all LTMR-dependent functions. These observations indicate that abnormal afferent activity initiated at sensory endings may be sufficient to engage sensory pathways underlying some paresthetic symptoms while leaving others largely unaffected, whereas progression to chronic neuropathic symptoms may require subsequent recruitment of the dorsal root ganglion. Highlights: Oxaliplatin rapidly induces spontaneous firing across touch and proprioceptors. The earliest spontaneous firing localizes to sensory endings, not the DRG. Sensory endings are a shared site of spontaneous and evoked hyperexcitability. Spontaneous firing engages some sensory pathways while sparing others.
- Open Access
Influence of exoskeleton stiffness on primary afferent feedback during stretch perturbations of isolated muscle-tendon unit
Exoskeletons assist and augment human movement, but their effects on proprioceptive feedback remain poorly understood. We examined how parallel exoskeleton stiffness influences primary muscle spindle firing. In an anesthetized rat preparation, controlled stretches of the medial gastrocnemius were applied with springs (0–0.5 N/mm) attached in parallel to the muscle-tendon unit (MTU) to simulate passive exoskeleton assistance. Fascicle length was measured with sonomicrometry, force and MTU length with a servo motor, and spindle instantaneous firing rate (IFR) with dorsal root recordings. Increasing exoskeleton stiffness decreased biological muscle force (3.1 ± 0.6 N to 1.6 ± 0.6 N, p < 0.001) and stiffness (4.4 ± 1.5 N/mm to 2.3 ± 1.3 N/mm, p < 0.01), while fascicle length increased (7.9 ± 1.3 mm to 8.3 ± 1.5 mm, p < 0.005). Despite these altered mechanics, spindle firing did not significantly change, and showed weak correlations with muscle length, velocity, force, and yank (R 2 ≤ 0.14). These results indicate that exoskeleton stiffness modifies fascicle dynamics without altering spindle firing. Previously proposed models of primary afferent firing did not sufficiently explain these results. This is the first in situ investigation of exoskeleton effects on primary afferent feedback during active contractions.
Open AccessInfluence of exoskeleton stiffness on primary afferent feedback during stretch perturbations of isolated muscle-tendon unit
Exoskeletons assist and augment human movement, but their effects on proprioceptive feedback remain poorly understood. We examined how parallel exoskeleton stiffness influences primary muscle spindle firing. In an anesthetized rat preparation, controlled stretches of the medial gastrocnemius were applied with springs (0–0.5 N/mm) attached in parallel to the muscle-tendon unit (MTU) to simulate passive exoskeleton assistance. Fascicle length was measured with sonomicrometry, force and MTU length with a servo motor, and spindle instantaneous firing rate (IFR) with dorsal root recordings. Increasing exoskeleton stiffness decreased biological muscle force (3.1 ± 0.6 N to 1.6 ± 0.6 N, p < 0.001) and stiffness (4.4 ± 1.5 N/mm to 2.3 ± 1.3 N/mm, p < 0.01), while fascicle length increased (7.9 ± 1.3 mm to 8.3 ± 1.5 mm, p < 0.005). Despite these altered mechanics, spindle firing did not significantly change, and showed weak correlations with muscle length, velocity, force, and yank (R 2 ≤ 0.14). These results indicate that exoskeleton stiffness modifies fascicle dynamics without altering spindle firing. Previously proposed models of primary afferent firing did not sufficiently explain these results. This is the first in situ investigation of exoskeleton effects on primary afferent feedback during active contractions.
- Open Access
- 23 June 2025
- Published by Wiley in Experimental Physiology
- Vol. 110 (10) , 1391-1400
Computing muscle mechanical state variables from combined proprioceptive sensory feedback
Proprioceptive sensory feedback is crucial for the control of movement. In many ways, sensorimotor control loops in the neuromuscular system act as state feedback controllers. These controllers combine input commands and sensory feedback regarding the mechanical state of the muscle, joint or limb to modulate the mechanical output of the muscles. To understand how these control circuits function, it is necessary to understand fully the mechanical state variables that are signalled by proprioceptive sensory (propriosensory) afferents. Using new computational approaches, we demonstrate how combinations of group Ia and II muscle spindle afferent feedback can allow for tuned responses to force and the rate of force (or length and velocity) and how combinations of muscle spindle and Golgi tendon organ feedback can parse external and internal (self‐generated) force. These models suggest that muscle spindle feedback might be used to monitor and control muscle forces in addition to length and velocity and, when combined with tendon organ feedback, can distinguish self‐generated from externally imposed forces. Given that these models combine feedback from different sensory afferent types, they emphasize the utility of analysing muscle propriosensors as an integrated population, rather than independently, to gain a better understanding of propriosensory–motor control. Furthermore, these models propose a framework that links neural connectivity in the spinal cord with neuromechanical control. Although considerable work has been done on propriosensory–motor pathways in the CNS, our aim is to build upon this work by emphasizing the mechanical context.
- 23 June 2025
- Published by Wiley in Experimental Physiology
- Vol. 110 (10) , 1391-1400
Open AccessComputing muscle mechanical state variables from combined proprioceptive sensory feedback
Proprioceptive sensory feedback is crucial for the control of movement. In many ways, sensorimotor control loops in the neuromuscular system act as state feedback controllers. These controllers combine input commands and sensory feedback regarding the mechanical state of the muscle, joint or limb to modulate the mechanical output of the muscles. To understand how these control circuits function, it is necessary to understand fully the mechanical state variables that are signalled by proprioceptive sensory (propriosensory) afferents. Using new computational approaches, we demonstrate how combinations of group Ia and II muscle spindle afferent feedback can allow for tuned responses to force and the rate of force (or length and velocity) and how combinations of muscle spindle and Golgi tendon organ feedback can parse external and internal (self‐generated) force. These models suggest that muscle spindle feedback might be used to monitor and control muscle forces in addition to length and velocity and, when combined with tendon organ feedback, can distinguish self‐generated from externally imposed forces. Given that these models combine feedback from different sensory afferent types, they emphasize the utility of analysing muscle propriosensors as an integrated population, rather than independently, to gain a better understanding of propriosensory–motor control. Furthermore, these models propose a framework that links neural connectivity in the spinal cord with neuromechanical control. Although considerable work has been done on propriosensory–motor pathways in the CNS, our aim is to build upon this work by emphasizing the mechanical context.
- Open Access
- 19 October 2023
- Published by Wiley in Experimental Physiology
- Vol. 109 (1) , 148-158
Attenuation of muscle spindle firing with artificially increased series compliance during stretch of relaxed muscle
Muscle spindles relay vital mechanosensory information for movement and posture, but muscle spindle feedback is coupled to skeletal motion by a compliant tendon. Little is known about the effects of tendon compliance on muscle spindle feedback during movement, and the complex firing of muscle spindles makes these effects difficult to predict. Our goal was to investigate changes in muscle spindle firing using added series elastic elements (SEEs) to mimic a more compliant tendon, and to characterize the accompanying changes in firing with respect to muscle–tendon unit (MTU) and muscle fascicle displacements (recorded via sonomicrometry). Sinusoidal, ramp‐and‐hold and triangular stretches were analysed to examine potential changes in muscle spindle instantaneous firing rates (IFRs) in locomotor‐ and perturbation‐like stretches as well as serial history dependence. Added SEEs effectively reduced overall MTU stiffness and generally reduced muscle spindle firing rates, but the effect differed across stretch types. During sinusoidal stretches, peak and mean firing rates were not reduced and IFR was best‐correlated with fascicle velocity. During ramp stretches, SEEs reduced the initial burst, dynamic and static responses of the spindle. Notably, IFR was negatively related to fascicle displacement during the hold phase. During triangular stretches, SEEs reduced the mean IFR during the first and second stretches, affecting the serial history dependence of mean IFR. Overall, these results demonstrate that tendon compliance may attenuate muscle spindle feedback during movement, but these changes cannot be fully explained by reduced muscle fascicle length or velocity, or MTU force.
- 19 October 2023
- Published by Wiley in Experimental Physiology
- Vol. 109 (1) , 148-158
Open AccessAttenuation of muscle spindle firing with artificially increased series compliance during stretch of relaxed muscle
Muscle spindles relay vital mechanosensory information for movement and posture, but muscle spindle feedback is coupled to skeletal motion by a compliant tendon. Little is known about the effects of tendon compliance on muscle spindle feedback during movement, and the complex firing of muscle spindles makes these effects difficult to predict. Our goal was to investigate changes in muscle spindle firing using added series elastic elements (SEEs) to mimic a more compliant tendon, and to characterize the accompanying changes in firing with respect to muscle–tendon unit (MTU) and muscle fascicle displacements (recorded via sonomicrometry). Sinusoidal, ramp‐and‐hold and triangular stretches were analysed to examine potential changes in muscle spindle instantaneous firing rates (IFRs) in locomotor‐ and perturbation‐like stretches as well as serial history dependence. Added SEEs effectively reduced overall MTU stiffness and generally reduced muscle spindle firing rates, but the effect differed across stretch types. During sinusoidal stretches, peak and mean firing rates were not reduced and IFR was best‐correlated with fascicle velocity. During ramp stretches, SEEs reduced the initial burst, dynamic and static responses of the spindle. Notably, IFR was negatively related to fascicle displacement during the hold phase. During triangular stretches, SEEs reduced the mean IFR during the first and second stretches, affecting the serial history dependence of mean IFR. Overall, these results demonstrate that tendon compliance may attenuate muscle spindle feedback during movement, but these changes cannot be fully explained by reduced muscle fascicle length or velocity, or MTU force.
- 1 October 2023
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 130 (4) , 895-909
Cancer survivors post-chemotherapy exhibit unimpaired short-latency stretch reflexes in the proximal upper extremity
Our results showed that cancer survivors after oxaliplatin (OX) treatment exhibited stretch reflexes that were comparable with age-matched healthy individuals in the proximal upper limb. The lack of OX effect might be linked to differences between the clinical and preclinical testing paradigms. These findings refine our expectations derived from the preclinical study and guide future assessments of OX effects that may have been insensitive to our measurement techniques.
- 1 October 2023
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 130 (4) , 895-909
Cancer survivors post-chemotherapy exhibit unimpaired short-latency stretch reflexes in the proximal upper extremity
Our results showed that cancer survivors after oxaliplatin (OX) treatment exhibited stretch reflexes that were comparable with age-matched healthy individuals in the proximal upper limb. The lack of OX effect might be linked to differences between the clinical and preclinical testing paradigms. These findings refine our expectations derived from the preclinical study and guide future assessments of OX effects that may have been insensitive to our measurement techniques.
- Open Access
- 29 April 2023
- Published by Wiley in Experimental Physiology
- Vol. 109 (1) , 35-44
Mechanosensory encoding in ex vivo muscle–nerve preparations
Our objective was to evaluate an ex vivo muscle–nerve preparation used to study mechanosensory signalling by low threshold mechanosensory receptors (LTMRs). Specifically, we aimed to assess how well the ex vivo preparation represents in vivo firing behaviours of the three major LTMR subtypes of muscle primary sensory afferents, namely type Ia and II muscle spindle (MS) afferents and type Ib tendon organ afferents. Using published procedures for ex vivo study of LTMRs in mouse hindlimb muscles, we replicated earlier reports on afferent firing in response to conventional stretch paradigms applied to non‐contracting, that is passive, muscle. Relative to in vivo studies, stretch‐evoked firing for confirmed MS afferents in the ex vivo preparation was markedly reduced in firing rate and deficient in encoding dynamic features of muscle stretch. These deficiencies precluded conventional means of discriminating type Ia and II afferents. Muscle afferents, including confirmed Ib afferents were often indistinguishable based on their similar firing responses to the same physiologically relevant stretch paradigms. These observations raise uncertainty about conclusions drawn from earlier ex vivo studies that either attribute findings to specific afferent types or suggest an absence of treatment effects on dynamic firing. However, we found that replacing the recording solution with bicarbonate buffer resulted in afferent firing rates and profiles more like those seen in vivo. Improving representation of the distinctive sensory encoding properties in ex vivo muscle–nerve preparations will promote accuracy in assigning molecular markers and mechanisms to heterogeneous types of muscle mechanosensory neurons.
- 29 April 2023
- Published by Wiley in Experimental Physiology
- Vol. 109 (1) , 35-44
Open AccessMechanosensory encoding in ex vivo muscle–nerve preparations
Our objective was to evaluate an ex vivo muscle–nerve preparation used to study mechanosensory signalling by low threshold mechanosensory receptors (LTMRs). Specifically, we aimed to assess how well the ex vivo preparation represents in vivo firing behaviours of the three major LTMR subtypes of muscle primary sensory afferents, namely type Ia and II muscle spindle (MS) afferents and type Ib tendon organ afferents. Using published procedures for ex vivo study of LTMRs in mouse hindlimb muscles, we replicated earlier reports on afferent firing in response to conventional stretch paradigms applied to non‐contracting, that is passive, muscle. Relative to in vivo studies, stretch‐evoked firing for confirmed MS afferents in the ex vivo preparation was markedly reduced in firing rate and deficient in encoding dynamic features of muscle stretch. These deficiencies precluded conventional means of discriminating type Ia and II afferents. Muscle afferents, including confirmed Ib afferents were often indistinguishable based on their similar firing responses to the same physiologically relevant stretch paradigms. These observations raise uncertainty about conclusions drawn from earlier ex vivo studies that either attribute findings to specific afferent types or suggest an absence of treatment effects on dynamic firing. However, we found that replacing the recording solution with bicarbonate buffer resulted in afferent firing rates and profiles more like those seen in vivo. Improving representation of the distinctive sensory encoding properties in ex vivo muscle–nerve preparations will promote accuracy in assigning molecular markers and mechanisms to heterogeneous types of muscle mechanosensory neurons.
- Open Access
- 26 March 2023
- Published by Wiley in Experimental Physiology
- Vol. 109 (1) , 55-65
Biophysical model of muscle spindle encoding
Muscle spindles encode mechanosensory information by mechanisms that remain only partially understood. Their complexity is expressed in mounting evidence of various molecular mechanisms that play essential roles in muscle mechanics, mechanotransduction and intrinsic modulation of muscle spindle firing behaviour. Biophysical modelling provides a tractable approach to achieve more comprehensive mechanistic understanding of such complex systems that would be difficult/impossible by more traditional, reductionist means. Our objective here was to construct the first integrative biophysical model of muscle spindle firing. We leveraged current knowledge of muscle spindle neuroanatomy and in vivo electrophysiology to develop and validate a biophysical model that reproduces key in vivo muscle spindle encoding characteristics. Crucially, to our knowledge, this is the first computational model of mammalian muscle spindle that integrates the asymmetric distribution of known voltage‐gated ion channels (VGCs) with neuronal architecture to generate realistic firing profiles, both of which seem likely to be of great biophysical importance. Results predict that particular features of neuronal architecture regulate specific characteristics of Ia encoding. Computational simulations also predict that the asymmetric distribution and ratios of VGCs is a complementary and, in some instances, orthogonal means to regulate Ia encoding. These results generate testable hypotheses and highlight the integral role of peripheral neuronal structure and ion channel composition and distribution in somatosensory signalling.
- 26 March 2023
- Published by Wiley in Experimental Physiology
- Vol. 109 (1) , 55-65
Open AccessBiophysical model of muscle spindle encoding
Muscle spindles encode mechanosensory information by mechanisms that remain only partially understood. Their complexity is expressed in mounting evidence of various molecular mechanisms that play essential roles in muscle mechanics, mechanotransduction and intrinsic modulation of muscle spindle firing behaviour. Biophysical modelling provides a tractable approach to achieve more comprehensive mechanistic understanding of such complex systems that would be difficult/impossible by more traditional, reductionist means. Our objective here was to construct the first integrative biophysical model of muscle spindle firing. We leveraged current knowledge of muscle spindle neuroanatomy and in vivo electrophysiology to develop and validate a biophysical model that reproduces key in vivo muscle spindle encoding characteristics. Crucially, to our knowledge, this is the first computational model of mammalian muscle spindle that integrates the asymmetric distribution of known voltage‐gated ion channels (VGCs) with neuronal architecture to generate realistic firing profiles, both of which seem likely to be of great biophysical importance. Results predict that particular features of neuronal architecture regulate specific characteristics of Ia encoding. Computational simulations also predict that the asymmetric distribution and ratios of VGCs is a complementary and, in some instances, orthogonal means to regulate Ia encoding. These results generate testable hypotheses and highlight the integral role of peripheral neuronal structure and ion channel composition and distribution in somatosensory signalling.
- Open Access
- 24 November 2022
- Published by Frontiers Media SA in Frontiers in Molecular Biosciences
- Vol. 9, 1017427
Mechanosensory encoding dysfunction emerges from cancer-chemotherapy interaction
Persistent sensory, motor and cognitive disabilities comprise chemotherapy-induced neural disorders (CIND) that limit quality of life with little therapeutic relief for cancer survivors. Our recent preclinical study provides new insight into a condition impacting the severity of chronic CIND. We find that sensorimotor disability observed following cancer treatment exceeds that attributable to chemotherapy alone. A possible explanation for intensified disability emerged from evidence that codependent effects of cancer and chemotherapy amplify defective firing in primary sensory neurons supplying one type of low threshold mechanosensory receptor (LTMR). Here we test whether cancer’s modification of chemotherapy-induced sensory defects generalizes across eight LTMR submodalities that collectively generate the signals of origin for proprioceptive and tactile perception and guidance of body movement. Preclinical study enabled controlled comparison of the independent contributions of chemotherapy and cancer to their clinically relevant combined effects. We compared data sampled from rats that were otherwise healthy or bearing colon cancer and treated, or not, with human-scaled, standard-of-care chemotherapy with oxaliplatin. Action potential firing patterns encoding naturalistic mechanical perturbations of skeletal muscle and skin were measured electrophysiologically in vivo from multiple types of LTMR neurons. All expressed aberrant encoding of dynamic and/or static features of mechanical stimuli in healthy rats treated with chemotherapy, and surprisingly also by some LTMRs in cancer-bearing rats that were not treated. By comparison, chemotherapy and cancer in combination worsened encoding aberrations, especially in slowly adapting LTMRs supplying both muscle and glabrous skin. Probabilistic modeling best predicted observed encoding defects when incorporating interaction effects of cancer and chemotherapy. We conclude that for multiple mechanosensory submodalities, the severity of encoding defects is modulated by a codependence of chemotherapy side effects and cancer’s systemic processes. We propose that the severity of CIND might be reduced by therapeutically targeting the mechanisms, yet to be determined, by which cancer magnifies chemotherapy’s neural side effects as an alternative to reducing chemotherapy and its life-saving benefits.
- 24 November 2022
- Published by Frontiers Media SA in Frontiers in Molecular Biosciences
- Vol. 9, 1017427
Open AccessMechanosensory encoding dysfunction emerges from cancer-chemotherapy interaction
Persistent sensory, motor and cognitive disabilities comprise chemotherapy-induced neural disorders (CIND) that limit quality of life with little therapeutic relief for cancer survivors. Our recent preclinical study provides new insight into a condition impacting the severity of chronic CIND. We find that sensorimotor disability observed following cancer treatment exceeds that attributable to chemotherapy alone. A possible explanation for intensified disability emerged from evidence that codependent effects of cancer and chemotherapy amplify defective firing in primary sensory neurons supplying one type of low threshold mechanosensory receptor (LTMR). Here we test whether cancer’s modification of chemotherapy-induced sensory defects generalizes across eight LTMR submodalities that collectively generate the signals of origin for proprioceptive and tactile perception and guidance of body movement. Preclinical study enabled controlled comparison of the independent contributions of chemotherapy and cancer to their clinically relevant combined effects. We compared data sampled from rats that were otherwise healthy or bearing colon cancer and treated, or not, with human-scaled, standard-of-care chemotherapy with oxaliplatin. Action potential firing patterns encoding naturalistic mechanical perturbations of skeletal muscle and skin were measured electrophysiologically in vivo from multiple types of LTMR neurons. All expressed aberrant encoding of dynamic and/or static features of mechanical stimuli in healthy rats treated with chemotherapy, and surprisingly also by some LTMRs in cancer-bearing rats that were not treated. By comparison, chemotherapy and cancer in combination worsened encoding aberrations, especially in slowly adapting LTMRs supplying both muscle and glabrous skin. Probabilistic modeling best predicted observed encoding defects when incorporating interaction effects of cancer and chemotherapy. We conclude that for multiple mechanosensory submodalities, the severity of encoding defects is modulated by a codependence of chemotherapy side effects and cancer’s systemic processes. We propose that the severity of CIND might be reduced by therapeutically targeting the mechanisms, yet to be determined, by which cancer magnifies chemotherapy’s neural side effects as an alternative to reducing chemotherapy and its life-saving benefits.
- Open Access
- 15 December 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 118 (51)
Neural circuit mechanisms of sensorimotor disability in cancer treatment
Significance: Severe and persistent disability often undermines the life-saving benefits of cancer treatment. Pain and fatigue, together with sensory, motor, and cognitive disorders, are chief among the constellation of side effects that occur with the platinum-based anticancer agents used in a majority of cancer treatments worldwide. These disabilities remain clinically unmitigated and empirically unexplained as research concentrates on peripheral degeneration of sensory neurons while understating the possible involvement of neural processes within the central nervous system. The present findings demonstrate functional defects in the fundamental properties of information processing localized within the central nervous system. We conclude that long-lasting sensorimotor and possibly other disabilities induced by cancer treatment result from independent neural defects compounded across both peripheral and central nervous systems.
- 15 December 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 118 (51)
Open AccessNeural circuit mechanisms of sensorimotor disability in cancer treatment
Significance: Severe and persistent disability often undermines the life-saving benefits of cancer treatment. Pain and fatigue, together with sensory, motor, and cognitive disorders, are chief among the constellation of side effects that occur with the platinum-based anticancer agents used in a majority of cancer treatments worldwide. These disabilities remain clinically unmitigated and empirically unexplained as research concentrates on peripheral degeneration of sensory neurons while understating the possible involvement of neural processes within the central nervous system. The present findings demonstrate functional defects in the fundamental properties of information processing localized within the central nervous system. We conclude that long-lasting sensorimotor and possibly other disabilities induced by cancer treatment result from independent neural defects compounded across both peripheral and central nervous systems.