Emulating the influence of exoskeleton stiffness on primary afferent feedback in rat isolated muscle–tendon unit
Open Access
- 15 November 2026
- journal article
- Published by The Company of Biologists in Journal of Experimental Biology
- Vol. 229 (22)
Abstract
Exoskeletons assist and augment movement, but their effects on proprioceptive feedback remain poorly understood because of challenges in making direct measures of sensory signals in humans. Here, we leveraged an animal model to explore how mechanical context akin to an elastic exoskeleton operating on a human lower limb joint influences primary muscle spindle firing. In an anesthetized rat preparation, we applied controlled stretches to the medial gastrocnemius with engineered springs (0–0.5 N mm−1) in parallel to the muscle–tendon unit (MTU) while modulating muscle activation to maintain overall system stiffness. Fascicle length was measured with sonomicrometry, force and MTU length with a servo motor, and spindle instantaneous firing rate (IFR) using dorsal root recordings. Trading off increases in exoskeleton stiffness with reductions in muscle activation decreased biological muscle force (3.1±0.6 N to 1.6±0.6 N, P<0.001) and stiffness (4.4±1.5 N mm−1 to 2.3±1.3 N mm−1, P<0.01), and increased fascicle length (7.9±1.3 mm to 8.3±1.5 mm, P<0.005). We found significant correlations between spindle firing and each independent fascicle dynamics factor we investigated (P<0.005). Thus, parallel stiffness modified muscle fascicle dynamics but did not alter spindle firing, possibly due to internal trade-offs in the salient fascicle dynamics that drive spindle behavior. Leveraging in situ experiments that enable monitoring of afferent feedback in complex mechanical contexts such as added parallel stiffness can provide a window into the effects of wearable devices on underlying sensory systems.Keywords
Funding Information
- National Science Foundation
- National Institute of Child Health and Human Development (R01HD090642)
- Georgia Institute of Technology
This publication has 38 references indexed in Scilit:
- Fascicle dynamics of the tibialis anterior muscle reflect whole-body walking economyScientific Reports, 2023
- Ultrasound imaging links soleus muscle neuromechanics and energetics during human walking with elastic ankle exoskeletonsScientific Reports, 2020
- Muscle recruitment and coordination with an ankle exoskeletonJournal of Biomechanics, 2017
- A benchtop biorobotic platform for in vitro observation of muscle-tendon dynamics with parallel mechanical assistance from an elastic exoskeletonJournal of Biomechanics, 2017
- Unconstrained muscle-tendon workloops indicate resonance tuning as a mechanism for elastic limb behavior during terrestrial locomotionProceedings of the National Academy of Sciences, 2015
- The passive properties of muscle fibers are velocity dependentJournal of Biomechanics, 2013
- Invariant ankle moment patterns when walking with and without a robotic ankle exoskeletonJournal of Biomechanics, 2010
- Optimal sensorimotor transformations for balanceNature Neuroscience, 2007
- Percutaneous electrical stimulation of corticospinal pathways at the level of the pyramidal decussation in humansAnnals of Neurology, 1991
- Function of the spindle dynamic response in stiffness regulation—a predictive mechanism provided by non-linear feedback1981