Ying Guan
Research Subjects
Ying Guan has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Lu Wang
Donghua University
2 shared publications - Jing Lin
Donghua University
1 shared publication - Jing Lin
Key Laboratory of Textile Science & Technology of Ministry of Education,CHINA. College of Textiles,CHINA. Donghua University, 201620,CHINA. Shanghai Frontiers Science Center of Advanced Textiles,CHINA. College of Textiles,CHINA. Donghua University, 201620,CHINA
1 shared publication - Martin William King
Wilson College of Textiles, North Carolina State University, Raleigh, NC 27695, USA
1 shared publication - Zhihui Dong
Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
1 shared publication
Latest Publications
- Open Access
- 1 January 2018
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2018 (1)
Comparative Study of the Effect of Structural Parameters on the Flexibility of Endovascular Stent Grafts
The complication of stent graft‐induced new entry (SINE) after thoracic endovascular aortic repair (TEVAR) may be caused by the spring‐back force of both ends of the stent grafts. Spring‐back force, which is exerted by the curvature and ends of stent grafts on the greater wall of the aorta, suggests poor flexibility. Research on stent graft flexibility via design optimization has been widely disregarded. Thus, this study investigates the relationship between stent graft structure and flexibility by measuring bending and spring‐back forces. Stent spacing (5, 10, and 15 mm), apex angle (30° and 45°), and strut configuration (Z‐ and M‐stented) were considered for the structural parameters. The overall tendency of spring‐back and bending forces was similar. The stent graft with 15 mm spacing attained the lowest force level. The force difference between samples with 30° and 45° apex angles became prominent as the curving angle increased. The sample with 45° stent apex attained low force value. The Z‐stented graft obtained a lower force than the M‐stented graft with the same number of struts per hoop. Consequently, optimal flexibility was obtained when the structural design was characterized by long stent spacing, big stent apex angle, and Z‐type strut configuration.
- 1 January 2018
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2018 (1)
Open AccessComparative Study of the Effect of Structural Parameters on the Flexibility of Endovascular Stent Grafts
The complication of stent graft‐induced new entry (SINE) after thoracic endovascular aortic repair (TEVAR) may be caused by the spring‐back force of both ends of the stent grafts. Spring‐back force, which is exerted by the curvature and ends of stent grafts on the greater wall of the aorta, suggests poor flexibility. Research on stent graft flexibility via design optimization has been widely disregarded. Thus, this study investigates the relationship between stent graft structure and flexibility by measuring bending and spring‐back forces. Stent spacing (5, 10, and 15 mm), apex angle (30° and 45°), and strut configuration (Z‐ and M‐stented) were considered for the structural parameters. The overall tendency of spring‐back and bending forces was similar. The stent graft with 15 mm spacing attained the lowest force level. The force difference between samples with 30° and 45° apex angles became prominent as the curving angle increased. The sample with 45° stent apex attained low force value. The Z‐stented graft obtained a lower force than the M‐stented graft with the same number of struts per hoop. Consequently, optimal flexibility was obtained when the structural design was characterized by long stent spacing, big stent apex angle, and Z‐type strut configuration.
- Open Access
Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones
Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU) and polyester graft (nitinol-PET) materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.
Open AccessCompliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones
Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU) and polyester graft (nitinol-PET) materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.