Jing Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jing Lin has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Lu Wang
Donghua University
2 shared publications Chaojing Li
Key Laboratory of Textile Science & Technology of Ministry of Education,CHINA. College of Textiles,CHINA. Donghua University, 201620,CHINA. Shanghai Frontiers Science Center of Advanced Textiles,CHINA. College of Textiles,CHINA. Donghua University, 201620,CHINA
1 shared publicationHui Tao
Key Laboratory of Textile Science & Technology of Ministry of Education,CHINA. College of Textiles,CHINA. Donghua University, 201620,CHINA. Shanghai Frontiers Science Center of Advanced Textiles,CHINA. College of Textiles,CHINA. Donghua University, 201620,CHINA
1 shared publication- Tonghe Zhu
School of Chemistry and Chemical Engineering, Shanghai Engineering Research Center of Pharmaceutical Intelligent Equipment, Shanghai Frontiers Science Research Center for Druggability of Cardiovascular Non-Coding RNA, Institute for Frontier Medical Technology, Shanghai University of Engineering Science, 333 Longteng Rd., Shanghai 201620, China
1 shared publication - Ying Guan
Key Laboratory of Textile Science and Technology
1 shared publication - Zhihui Dong
Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
1 shared publication
Latest Publications
- Open Access
- 14 August 2026
- Published by Tsinghua University Press in Nano Research
- Vol. 19 (10) , 94908970
Bioactive nanofibers covered stent with matched mechanics and durable gemcitabine release for treating esophageal cancer
Developing a drug-eluting esophageal stent (DEES), which provides both mechanical support and local chemotherapy, represents a preferred treatment option for patients with advanced esophageal cancer. However, existing DEES have limitations such as drug loading via surface micro/nano-structures or physical blending of drugs into polymer covering, often lead to issues like initial burst release, short-lasting therapeutic effects, or compromised mechanical properties. To address the above challenges, we synthesized gemcitabine (GEM) blocked biodegradable polyurethane (PG) and then covered it around the surface of nickel-titanium (NiTi) stent via electrospinning to form nanofibers covered stent. This electrospun PG nanofibers achieved firm adhesion without compromising the original mechanical integrity of NiTi stent. In vitro data demonstrated that the PG fibers presented prominent antitumor therapy effect and antiangiogenesis ability, as well as enabled degradation-associated drug release, resulting in less than 1% initial burst release within 24 h and sustained release over 24 weeks. In vivo assessments indicated that the PG fibers could continuously inhibit tumor growth by inducing tumor cell apoptosis and suppressing tumor angiogenesis. This study demonstrates the bioactive nanofibers covered stent with matched mechanics and durable efficacious antitumor, which could offer a potential strategy for treating esophageal cancer via local chemotherapy.
- 14 August 2026
- Published by Tsinghua University Press in Nano Research
- Vol. 19 (10) , 94908970
Open AccessBioactive nanofibers covered stent with matched mechanics and durable gemcitabine release for treating esophageal cancer
Developing a drug-eluting esophageal stent (DEES), which provides both mechanical support and local chemotherapy, represents a preferred treatment option for patients with advanced esophageal cancer. However, existing DEES have limitations such as drug loading via surface micro/nano-structures or physical blending of drugs into polymer covering, often lead to issues like initial burst release, short-lasting therapeutic effects, or compromised mechanical properties. To address the above challenges, we synthesized gemcitabine (GEM) blocked biodegradable polyurethane (PG) and then covered it around the surface of nickel-titanium (NiTi) stent via electrospinning to form nanofibers covered stent. This electrospun PG nanofibers achieved firm adhesion without compromising the original mechanical integrity of NiTi stent. In vitro data demonstrated that the PG fibers presented prominent antitumor therapy effect and antiangiogenesis ability, as well as enabled degradation-associated drug release, resulting in less than 1% initial burst release within 24 h and sustained release over 24 weeks. In vivo assessments indicated that the PG fibers could continuously inhibit tumor growth by inducing tumor cell apoptosis and suppressing tumor angiogenesis. This study demonstrates the bioactive nanofibers covered stent with matched mechanics and durable efficacious antitumor, which could offer a potential strategy for treating esophageal cancer via local chemotherapy.
- Open Access
- 1 January 2018
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2018 (1)
Comparative Study of the Effect of Structural Parameters on the Flexibility of Endovascular Stent Grafts
The complication of stent graft‐induced new entry (SINE) after thoracic endovascular aortic repair (TEVAR) may be caused by the spring‐back force of both ends of the stent grafts. Spring‐back force, which is exerted by the curvature and ends of stent grafts on the greater wall of the aorta, suggests poor flexibility. Research on stent graft flexibility via design optimization has been widely disregarded. Thus, this study investigates the relationship between stent graft structure and flexibility by measuring bending and spring‐back forces. Stent spacing (5, 10, and 15 mm), apex angle (30° and 45°), and strut configuration (Z‐ and M‐stented) were considered for the structural parameters. The overall tendency of spring‐back and bending forces was similar. The stent graft with 15 mm spacing attained the lowest force level. The force difference between samples with 30° and 45° apex angles became prominent as the curving angle increased. The sample with 45° stent apex attained low force value. The Z‐stented graft obtained a lower force than the M‐stented graft with the same number of struts per hoop. Consequently, optimal flexibility was obtained when the structural design was characterized by long stent spacing, big stent apex angle, and Z‐type strut configuration.
- 1 January 2018
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2018 (1)
Open AccessComparative Study of the Effect of Structural Parameters on the Flexibility of Endovascular Stent Grafts
The complication of stent graft‐induced new entry (SINE) after thoracic endovascular aortic repair (TEVAR) may be caused by the spring‐back force of both ends of the stent grafts. Spring‐back force, which is exerted by the curvature and ends of stent grafts on the greater wall of the aorta, suggests poor flexibility. Research on stent graft flexibility via design optimization has been widely disregarded. Thus, this study investigates the relationship between stent graft structure and flexibility by measuring bending and spring‐back forces. Stent spacing (5, 10, and 15 mm), apex angle (30° and 45°), and strut configuration (Z‐ and M‐stented) were considered for the structural parameters. The overall tendency of spring‐back and bending forces was similar. The stent graft with 15 mm spacing attained the lowest force level. The force difference between samples with 30° and 45° apex angles became prominent as the curving angle increased. The sample with 45° stent apex attained low force value. The Z‐stented graft obtained a lower force than the M‐stented graft with the same number of struts per hoop. Consequently, optimal flexibility was obtained when the structural design was characterized by long stent spacing, big stent apex angle, and Z‐type strut configuration.