Tomasz Balkowiec
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Tomasz Balkowiec has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Wlodzimierz Koczara
Warsaw University of Technology, Koszykowa 75, 00-662, Poland
9 shared publications - Krzysztof Jackiewicz
Faculty of Electrical Engineering, Warsaw University of Technology, Warsaw, Poland
3 shared publications - Andrzej Straś
Faculty of Electrical Engineering, Warsaw University of Technology, Warsaw, Poland
2 shared publications - Arkadiusz Kaszewski
Institute of Control and Industrial Electronics, Warsaw University of Technology, 75 Koszykowa Street, 00-662 Warsaw, Poland
2 shared publications A. Krasnodebski
1 shared publication- Andrzej Straś
Warsaw Univ Sci & Technol, Inst Sterowania & Elekt Przemyslowej, Ul Koszykowa 75, PL-00662 Warsaw, Poland
1 shared publication
Latest Publications
- Open Access
- 28 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 205791-205804
Design of Discrete State Feedback Current Control for a Drive System With a Permanent Magnet Linear Synchronous Motor and LC Filter in an Application for Small Cargo Transportation
The paper proposes a design procedure for a current control system of a permanent magnet linear synchronous machine for a small cargo transportation system. The drive system utilizes a long stator linear motor, and the vehicle is equipped with permanent magnets. Due to the possible high distance between the inverter and stator, the power circuit contains an LC filter. Therefore, the current controller must deal with a three-phase inductive–capacitive–inductive (LCL) circuit. Moreover, the stator of the machine is divided into segments. This leads to relatively fast changes in the induced voltage when the vehicle is passing through segment boundaries. Therefore, the current controller must deal with fast-changing disturbances. The state feedback control with gains selected using the linear-quadratic regulator approach is used to achieve high-quality system performance. Design and implementation include retuning of the controller gains for variable synchronous frequency. The control system is designed in the discrete domain concerning signal processing delay. The current control system with optimal gains is applied on the digital signal controller and verified experimentally on the test track.
- 28 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 205791-205804
Open AccessDesign of Discrete State Feedback Current Control for a Drive System With a Permanent Magnet Linear Synchronous Motor and LC Filter in an Application for Small Cargo Transportation
The paper proposes a design procedure for a current control system of a permanent magnet linear synchronous machine for a small cargo transportation system. The drive system utilizes a long stator linear motor, and the vehicle is equipped with permanent magnets. Due to the possible high distance between the inverter and stator, the power circuit contains an LC filter. Therefore, the current controller must deal with a three-phase inductive–capacitive–inductive (LCL) circuit. Moreover, the stator of the machine is divided into segments. This leads to relatively fast changes in the induced voltage when the vehicle is passing through segment boundaries. Therefore, the current controller must deal with fast-changing disturbances. The state feedback control with gains selected using the linear-quadratic regulator approach is used to achieve high-quality system performance. Design and implementation include retuning of the controller gains for variable synchronous frequency. The control system is designed in the discrete domain concerning signal processing delay. The current control system with optimal gains is applied on the digital signal controller and verified experimentally on the test track.
- 29 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (1) , 374-391
Generalization of the Transient DC-Bias Current Elimination Scheme in Dual Active Bridge Converters Using the Real-Time Zero Current Crossing Prediction Algorithm
The dual active bridge (DAB) is a power electronic converter widely used in areas such as transportation, renewable energy sources, and battery-based energy storage systems. This type of converter typically serves as an interface between voltage sources, providing galvanic isolation while operating under varying transferred power. As a result, transient dc-bias current may arise, leading to increased losses and potentially causing saturation of magnetic components. Typically, to overcome the aforementioned negative effects, proper converter control is utilized. One recently proposed method for eliminating dc-bias current is based on the idea of shifting the voltage waveforms in phase so that the current waveforms, at the beginning of the switching cycle, start from zero. This approach enables a seamless power transition. However, the aforementioned method has been implemented only for the specific modes of triple-phase shift (TPS) modulation. Another aspect is the dead-time effect, for which compensation has not been shown in a straightforward manner. Given the above, the algorithm called real-time zero current crossing prediction (RT-ZCCP) is proposed to augment the known solution with an arbitrary modulation scheme compatibility, along with a simple dead-time compensation technique. This article outlines the RT-ZCCP algorithm in a step-by-step manner, including the detailed analysis of the dead-time effect, and proposes an optimal method to choose the corrective time value. The circuit-parameter-dependent robustness analysis of the proposed algorithm has also been performed. The RT-ZCCP algorithm was implemented on the TMS320F28379D microcontroller and has been successfully verified on the 1.3-kW laboratory prototype with SiC-based MOSFET modules, operating at a switching frequency of 40 kHz. What is more, the experimental results comparison with the other competitive methods has been performed to prove the effectiveness of the proposed RT-ZCCP algorithm.
- 29 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (1) , 374-391
Generalization of the Transient DC-Bias Current Elimination Scheme in Dual Active Bridge Converters Using the Real-Time Zero Current Crossing Prediction Algorithm
The dual active bridge (DAB) is a power electronic converter widely used in areas such as transportation, renewable energy sources, and battery-based energy storage systems. This type of converter typically serves as an interface between voltage sources, providing galvanic isolation while operating under varying transferred power. As a result, transient dc-bias current may arise, leading to increased losses and potentially causing saturation of magnetic components. Typically, to overcome the aforementioned negative effects, proper converter control is utilized. One recently proposed method for eliminating dc-bias current is based on the idea of shifting the voltage waveforms in phase so that the current waveforms, at the beginning of the switching cycle, start from zero. This approach enables a seamless power transition. However, the aforementioned method has been implemented only for the specific modes of triple-phase shift (TPS) modulation. Another aspect is the dead-time effect, for which compensation has not been shown in a straightforward manner. Given the above, the algorithm called real-time zero current crossing prediction (RT-ZCCP) is proposed to augment the known solution with an arbitrary modulation scheme compatibility, along with a simple dead-time compensation technique. This article outlines the RT-ZCCP algorithm in a step-by-step manner, including the detailed analysis of the dead-time effect, and proposes an optimal method to choose the corrective time value. The circuit-parameter-dependent robustness analysis of the proposed algorithm has also been performed. The RT-ZCCP algorithm was implemented on the TMS320F28379D microcontroller and has been successfully verified on the 1.3-kW laboratory prototype with SiC-based MOSFET modules, operating at a switching frequency of 40 kHz. What is more, the experimental results comparison with the other competitive methods has been performed to prove the effectiveness of the proposed RT-ZCCP algorithm.
- 5 April 2023
- Published by Elsevier in ISA Transactions
- Vol. 139, 724-738
Novel dual thread angle sampled multioscillatory-based control for speed ripple reduction in a switched reluctance machine-based drive
- 5 April 2023
- Published by Elsevier in ISA Transactions
- Vol. 139, 724-738
Novel dual thread angle sampled multioscillatory-based control for speed ripple reduction in a switched reluctance machine-based drive
- 1 January 2021
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 97 (2) , 64-67
Control system of a switched reluctance machine with angle sampled multioscillatory controller for torque ripple reduction
This paper presents control system of a switched reluctance machine for torque ripple reduction. The control method uses oscillatory terms as a part of speed controller. The presented approach uses oscillatory terms in the rotor angle domain (angle sampled), instead of well-known time domain. This method assures synchronization of resonant frequencies of oscillatory terms with the variable rotor speed. The proposed control system is verified with numerical simulations in PLECS software.
- 1 January 2021
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 97 (2) , 64-67
Control system of a switched reluctance machine with angle sampled multioscillatory controller for torque ripple reduction
This paper presents control system of a switched reluctance machine for torque ripple reduction. The control method uses oscillatory terms as a part of speed controller. The presented approach uses oscillatory terms in the rotor angle domain (angle sampled), instead of well-known time domain. This method assures synchronization of resonant frequencies of oscillatory terms with the variable rotor speed. The proposed control system is verified with numerical simulations in PLECS software.
- 18 October 2018
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 29 (3) , e2748
Island operation of a three-phase adjustable speed generation system
- 18 October 2018
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 29 (3) , e2748
Island operation of a three-phase adjustable speed generation system
- 5 September 2017
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (9) , 43-47
Three-Phase Rectifier Dedicated to DC Traction Substation
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 5 September 2017
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (9) , 43-47
Three-Phase Rectifier Dedicated to DC Traction Substation
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Adjustable speed generation system under fault condition
- 1 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Adjustable speed generation system under fault condition
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Island operation of the adjustable speed generation system
The paper presents a fuel saving, adjustable speed, autonomous generation system providing fixed amplitude and frequency sinusoidal voltage. A permanent magnet generator, driven by a Diesel engine, delivers variable frequency and amplitude AC voltage whereas an AC/DC/AC converter produces demanded voltage. Autonomous generation system is dedicated to the AC microgrid as the basic and continuous source of electricity. It supplies a great number of loads and in a case of short circuit, a tripping switch should instantly disconnect the malfunctioning user and continue power supply action. A very high current is required to disconnect the tripping switch, thus an AC/DC/AC power electronic converter must be significantly over-dimensioned. During the short circuit, the bypass made of parallelly connected thyristors (direct converter type cycloconverter) connects the generator to the power electronic converter's output, thus the variable frequency and amplitude of the generator voltage is parallelly connected to the inverter. The paper describes the adjustable speed generation system equipped in the asynchronous bypass and presents experimental results of the 40 kVA generation unit driven by a Diesel engine.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Island operation of the adjustable speed generation system
The paper presents a fuel saving, adjustable speed, autonomous generation system providing fixed amplitude and frequency sinusoidal voltage. A permanent magnet generator, driven by a Diesel engine, delivers variable frequency and amplitude AC voltage whereas an AC/DC/AC converter produces demanded voltage. Autonomous generation system is dedicated to the AC microgrid as the basic and continuous source of electricity. It supplies a great number of loads and in a case of short circuit, a tripping switch should instantly disconnect the malfunctioning user and continue power supply action. A very high current is required to disconnect the tripping switch, thus an AC/DC/AC power electronic converter must be significantly over-dimensioned. During the short circuit, the bypass made of parallelly connected thyristors (direct converter type cycloconverter) connects the generator to the power electronic converter's output, thus the variable frequency and amplitude of the generator voltage is parallelly connected to the inverter. The paper describes the adjustable speed generation system equipped in the asynchronous bypass and presents experimental results of the 40 kVA generation unit driven by a Diesel engine.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Modified Vienna (Warsaw) rectifier under fault condition
Reliability and safety issues of the electrical power generation systems becomes more and more popular research topic - especially analysis of the electrical power supply systems operation under fault conditions like e.g. overload or short circuit. Appropriate topology of the rectifier is required to provide stable output voltage and control of the supplied AC current. One of the rectifier topologies that ensures both requirements is Vienna (Warsaw) rectifier. In case of fault condition, like overload or short circuit, Vienna (Warsaw) rectifier must be equipped in circuit breaker. Therefore, this paper proposes modified topology of the Vienna (Warsaw) rectifier which gives ability to disconnect the electrical power generation system during overload or short circuit (fault condition) without using current protective devices. Proposed rectifier is supplied from three-phase four-wire power generation system - permanent magnet generator driven by a Diesel engine. Two methods of overload and short circuit identification have been also analysed.
- 1 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Modified Vienna (Warsaw) rectifier under fault condition
Reliability and safety issues of the electrical power generation systems becomes more and more popular research topic - especially analysis of the electrical power supply systems operation under fault conditions like e.g. overload or short circuit. Appropriate topology of the rectifier is required to provide stable output voltage and control of the supplied AC current. One of the rectifier topologies that ensures both requirements is Vienna (Warsaw) rectifier. In case of fault condition, like overload or short circuit, Vienna (Warsaw) rectifier must be equipped in circuit breaker. Therefore, this paper proposes modified topology of the Vienna (Warsaw) rectifier which gives ability to disconnect the electrical power generation system during overload or short circuit (fault condition) without using current protective devices. Proposed rectifier is supplied from three-phase four-wire power generation system - permanent magnet generator driven by a Diesel engine. Two methods of overload and short circuit identification have been also analysed.
- 1 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 138-143
Fuel saving integrated adjustable speed generation system dedicated to bipolar DC PERFECT microgrid
High power generating system delivers three-wire DC voltage (bi-polar system) dedicated to DC microgrid. An internal combustion engine in wide speed range drives a six phase permanent magnet generator producing variable frequency and amplitude voltage. The engine operates in high efficiency region. The generator's high frequency voltage is rectified. In the new developed generating system a boost rectifier draws sinusoidal current from the permanent magnet generator and stabilizes output DC voltages. The boost rectifier produces two symmetrical DC voltages - positive and negative referenced to a zero potential. The system topology provides stiff zero potential that is very advantageous in DC/AC conversion producing multiphase AC sinusoidal voltage. The boost rectifier is very robust and represents high short circuit current. Moreover, the generating set is equipped in balancer that in case of asymmetrical load keeps zero current in the neutral wire. It is also equipped in energy storage system, connected in parallel to the DC voltages to stabilize them in case of load change. Computer calculations of the 1224 kW (1950 rpm) generating system confirms general performance of the generation system.
- 1 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 138-143
Fuel saving integrated adjustable speed generation system dedicated to bipolar DC PERFECT microgrid
High power generating system delivers three-wire DC voltage (bi-polar system) dedicated to DC microgrid. An internal combustion engine in wide speed range drives a six phase permanent magnet generator producing variable frequency and amplitude voltage. The engine operates in high efficiency region. The generator's high frequency voltage is rectified. In the new developed generating system a boost rectifier draws sinusoidal current from the permanent magnet generator and stabilizes output DC voltages. The boost rectifier produces two symmetrical DC voltages - positive and negative referenced to a zero potential. The system topology provides stiff zero potential that is very advantageous in DC/AC conversion producing multiphase AC sinusoidal voltage. The boost rectifier is very robust and represents high short circuit current. Moreover, the generating set is equipped in balancer that in case of asymmetrical load keeps zero current in the neutral wire. It is also equipped in energy storage system, connected in parallel to the DC voltages to stabilize them in case of load change. Computer calculations of the 1224 kW (1950 rpm) generating system confirms general performance of the generation system.