Gurunath Gurrala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gurunath Gurrala has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Durvesh Kalke
Department of Electrical Engineering, Indian Institute of Science, Bengaluru, India
3 shared publications - Francis C. Joseph
Department of Electrical Engineering, Indian Institute of Science, Bengaluru, India
3 shared publications - Tanmay Mishra
Department of Electrical and Biomedical Engineering, University of Vermont, USA
3 shared publications - Ashish Joglekar
Robert Bosch Centre for CyberPhysical Systems and the AI and Robots Technology Park, Indian Institute of Science, Bengaluru, India
2 shared publications - Himanshu Tyagi
Electrical Communication Engineering department, Indian Institute of Science, Bengaluru, India
2 shared publications - K. R. Sahasranand
Department of Electrical Communication Engineering, Indian Institute of Science, Bengaluru, India
2 shared publications
Latest Publications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 24 (5) , 80-95
Guarding Digital Substations: Securing IEC 61850 Digital Substations with AI: Challenges, Opportunities, and the Path Forward
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power and Energy Magazine
- Vol. 24 (5) , 80-95
Guarding Digital Substations: Securing IEC 61850 Digital Substations with AI: Challenges, Opportunities, and the Path Forward
- 17 July 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 264
Exploiting the data from digital protective relays for generator model validation in power systems
- 17 July 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 264
Exploiting the data from digital protective relays for generator model validation in power systems
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 17 (4) , 1-14
Emulation of Ternary Pumped Storage Hydro Plants on a Laboratory Micro-Alternator
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 17 (4) , 1-14
Emulation of Ternary Pumped Storage Hydro Plants on a Laboratory Micro-Alternator
- 29 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (3) , 2191-2204
Synchronous Generator Emulation Using Output Matching Control Through Feedback Linearization
Micro-machines possessing parameters similar to those of large synchronous machines can be used to analyze the dynamic performance of the large machines in the laboratory. However, the scalability of the emulation experimental platform is constrained, given that a micro-machine can replicate solely the dynamics of a single turbo-generator. In this paper, an output matching controller based on the output feedback linearization technique has been proposed to emulate different synchronous machines on a single laboratory micro-machine. Synchronous generators with ratings of 128 MVA, 192 MVA, and 247.5 MVA have been emulated on a 5 kVA micro-machine. The IEEE 1.1 synchronous generator model is used as the reference machine model to be emulated. The dynamics observed in terminal voltage and the generator speed of the reference machine are emulated on the micro-machine. The efficacy of the proposed emulation approach is validated under both small and large disturbances created within the experimental testbed.
- 29 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (3) , 2191-2204
Synchronous Generator Emulation Using Output Matching Control Through Feedback Linearization
Micro-machines possessing parameters similar to those of large synchronous machines can be used to analyze the dynamic performance of the large machines in the laboratory. However, the scalability of the emulation experimental platform is constrained, given that a micro-machine can replicate solely the dynamics of a single turbo-generator. In this paper, an output matching controller based on the output feedback linearization technique has been proposed to emulate different synchronous machines on a single laboratory micro-machine. Synchronous generators with ratings of 128 MVA, 192 MVA, and 247.5 MVA have been emulated on a 5 kVA micro-machine. The IEEE 1.1 synchronous generator model is used as the reference machine model to be emulated. The dynamics observed in terminal voltage and the generator speed of the reference machine are emulated on the micro-machine. The efficacy of the proposed emulation approach is validated under both small and large disturbances created within the experimental testbed.
- 8 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (2) , 1401-1413
Adaptive Homotopy Based Coarse Solver for Parareal-in-Time Transient Stability Simulations
The Parareal-in-time algorithm belongs to a class of temporal decomposition methods for parallel solutions of differential equations. Parareal utilizes two solvers: a coarse solver and a fine solver. The Parareal algorithm's performance depends on selecting the suitable solvers and the best time step for the coarse solver. In this paper, a new adaptive coarse solver based on homotopy analysis, by controlling the local truncation error (LTE), has been proposed with an option to adapt either the time step or both the time step and the auxiliary parameter $c$ of homotopy. Using two communication paradigms, Master Worker and Distributed, in message passing interface (MPI), the proposed coarse solvers are evaluated for transient stability simulations. Fixed step Runge-Kutta $4^{th}$ order (RK4), modified Euler (ME) and homotopy analysis method (HM) are used as the fine solvers. In addition, comparisons are made with the ME, HM, and an adaptive homotopy-assisted ME as coarse solvers. Many disturbance scenarios have been simulated on the Polish 2383 bus system and PEGASE 13569 bus system using a 32-core server-grade machine. The Master Worker paradigm is found to be faster than the Distributed paradigm. Using lighter solvers (ME, HM) for coarse and fine solvers has shown the best execution times. The proposed coarse solver, notably with both the time step & $c$ adaptation, using LTE specification higher than the Parareal convergence tolerance has shown better execution time and faster than real-time performance while maintaining acceptable accuracy in both the paradigms with lighter fine solvers consistently.
- 8 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (2) , 1401-1413
Adaptive Homotopy Based Coarse Solver for Parareal-in-Time Transient Stability Simulations
The Parareal-in-time algorithm belongs to a class of temporal decomposition methods for parallel solutions of differential equations. Parareal utilizes two solvers: a coarse solver and a fine solver. The Parareal algorithm's performance depends on selecting the suitable solvers and the best time step for the coarse solver. In this paper, a new adaptive coarse solver based on homotopy analysis, by controlling the local truncation error (LTE), has been proposed with an option to adapt either the time step or both the time step and the auxiliary parameter $c$ of homotopy. Using two communication paradigms, Master Worker and Distributed, in message passing interface (MPI), the proposed coarse solvers are evaluated for transient stability simulations. Fixed step Runge-Kutta $4^{th}$ order (RK4), modified Euler (ME) and homotopy analysis method (HM) are used as the fine solvers. In addition, comparisons are made with the ME, HM, and an adaptive homotopy-assisted ME as coarse solvers. Many disturbance scenarios have been simulated on the Polish 2383 bus system and PEGASE 13569 bus system using a 32-core server-grade machine. The Master Worker paradigm is found to be faster than the Distributed paradigm. Using lighter solvers (ME, HM) for coarse and fine solvers has shown the best execution times. The proposed coarse solver, notably with both the time step & $c$ adaptation, using LTE specification higher than the Parareal convergence tolerance has shown better execution time and faster than real-time performance while maintaining acceptable accuracy in both the paradigms with lighter fine solvers consistently.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (4) , 2253-2263
Solid-State Point-on-Wave Fault Branch With Fault Clearing Capability
A Point-on-Wave Fault Branch (PWFB) can be used to create various balanced and unbalanced electrical faults in an experimental testbed. Utilizing fully controllable semiconductor switches, the PWFB offers unique advantages of precise fault creation and clearance at user-defined angles relative to the input reference voltage. In contrast to the traditional fault branches utilizing Four-Quadrant Switches (FQSes), which necessitate one or two capacitors or surge arresters for over-voltage protection per FQS, this paper proposes a PWFB design that incorporates a single capacitor to protect all FQSes from over-voltage conditions during various fault scenarios. The proposed method significantly reduces the overall size and cost of the PWFB. Furthermore, the paper introduces a novel FQS configuration, leveraging commercially available half-bridge Insulated Gate Bipolar Transistor (IGBT) and power diode modules. A PWFB prototype is developed and rigorously tested on two distinct systems: (i) a 5 kVA grid-connected transformer with an inductive load and (ii) a Single-Machine Infinite Bus (SMIB) system. These experiments demonstrate the single capacitor's efficacy in clamping peak voltages and validate the PWFB's ability to generate consistent and reproducible faults while protecting all associated FQSes.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (4) , 2253-2263
Solid-State Point-on-Wave Fault Branch With Fault Clearing Capability
A Point-on-Wave Fault Branch (PWFB) can be used to create various balanced and unbalanced electrical faults in an experimental testbed. Utilizing fully controllable semiconductor switches, the PWFB offers unique advantages of precise fault creation and clearance at user-defined angles relative to the input reference voltage. In contrast to the traditional fault branches utilizing Four-Quadrant Switches (FQSes), which necessitate one or two capacitors or surge arresters for over-voltage protection per FQS, this paper proposes a PWFB design that incorporates a single capacitor to protect all FQSes from over-voltage conditions during various fault scenarios. The proposed method significantly reduces the overall size and cost of the PWFB. Furthermore, the paper introduces a novel FQS configuration, leveraging commercially available half-bridge Insulated Gate Bipolar Transistor (IGBT) and power diode modules. A PWFB prototype is developed and rigorously tested on two distinct systems: (i) a 5 kVA grid-connected transformer with an inductive load and (ii) a Single-Machine Infinite Bus (SMIB) system. These experiments demonstrate the single capacitor's efficacy in clamping peak voltages and validate the PWFB's ability to generate consistent and reproducible faults while protecting all associated FQSes.
- 8 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Design of IEC/IEEE 60255-118-1-2018 Compliant SOGI-PLL for Synchrophasor Measurements
A second-order generalized integrator (SOGI) phase-locked loop (PLL) with a linear quadratic regulator (LQR)-based bumpless compensator (BC) switching mechanism is proposed in this article for acquiring synchrophasor measurements compliant with IEC/IEEE 60255-118-1-2018. It has been shown that the SOGI-PLL, without any pre/post-filtering stages, requires two distinct ranges of parameter sets—Set-1 to satisfy steady-state scan, dynamic tests and Set-2 to meet out-of-band (OOB) and harmonic rejection (HR) tests. Therefore, the instance of switching the parameters must be ascertained along with a mechanism to switch between two sets of parameters. Hence, an LQR-based BC switching mechanism is proposed in this article to switch between two parameter sets. The input signal’s unwanted frequency components (harmonic or interharmonic frequency) are quantified using a notch filter and a moving average filter (MAF) to generate the switching signal that activates the transition between the two parameter sets. The performance of SOGI-PLL is tested under steady-state and dynamic test conditions as per IEC/IEEE 60255-118-1-2018 and compared with the enhanced PLL-based approach. The SOGI-PLL performance is found to be better than the enhanced PLL-based approach and is compliant with IEC/IEEE 60255-118-1-2018 under all specified tests. The performance is also tested with an actual voltage signal measured at the laboratory supply, and compliance with the standard was ascertained.
- 8 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Design of IEC/IEEE 60255-118-1-2018 Compliant SOGI-PLL for Synchrophasor Measurements
A second-order generalized integrator (SOGI) phase-locked loop (PLL) with a linear quadratic regulator (LQR)-based bumpless compensator (BC) switching mechanism is proposed in this article for acquiring synchrophasor measurements compliant with IEC/IEEE 60255-118-1-2018. It has been shown that the SOGI-PLL, without any pre/post-filtering stages, requires two distinct ranges of parameter sets—Set-1 to satisfy steady-state scan, dynamic tests and Set-2 to meet out-of-band (OOB) and harmonic rejection (HR) tests. Therefore, the instance of switching the parameters must be ascertained along with a mechanism to switch between two sets of parameters. Hence, an LQR-based BC switching mechanism is proposed in this article to switch between two parameter sets. The input signal’s unwanted frequency components (harmonic or interharmonic frequency) are quantified using a notch filter and a moving average filter (MAF) to generate the switching signal that activates the transition between the two parameter sets. The performance of SOGI-PLL is tested under steady-state and dynamic test conditions as per IEC/IEEE 60255-118-1-2018 and compared with the enhanced PLL-based approach. The SOGI-PLL performance is found to be better than the enhanced PLL-based approach and is compliant with IEC/IEEE 60255-118-1-2018 under all specified tests. The performance is also tested with an actual voltage signal measured at the laboratory supply, and compliance with the standard was ascertained.
- 3 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (3) , 1881-1892
Emulation of IEEE STD 421.5/Industrial Excitation Systems Using a Micro-Alternator's Exciter
Micro-alternators, having similar parameters as turbo-alternators, play a significant role in the experimental evaluation of power system dynamics. Early thyristor excitation systems of micro-alternators have limited re-configurable options. Three possible control structures, two closed-loop control structures proposed in the literature and one open-loop control structure proposed in this paper, including a time constant regulator to mimic large machine time constants, are evaluated to emulate any IEEE 421.5 standard excitation system model or interface an industrial excitation system controller hardware in the loop (CHIL). It is shown that the communication delay introduced in CHIL does not impact the closed-loop stability within the bandwidth requirements of the excitation systems. One of the closed-loop structures, which is more generalized, and the open-loop structure performances are compared for emulating IEEE AC4C, DC1C, and ST1C excitation systems on a laboratory micro-machine based single machine infinite bus test system with buck exciter and H-bridge chopper (HBC) exciter using EMTP simulations under small and large disturbances. HBC exciter is used in the experimental validation with both the closed-loop and the open-loop control structures. The proposed open-loop structure is easy to implement and performs better than the closed-loop structure.
- 3 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (3) , 1881-1892
Emulation of IEEE STD 421.5/Industrial Excitation Systems Using a Micro-Alternator's Exciter
Micro-alternators, having similar parameters as turbo-alternators, play a significant role in the experimental evaluation of power system dynamics. Early thyristor excitation systems of micro-alternators have limited re-configurable options. Three possible control structures, two closed-loop control structures proposed in the literature and one open-loop control structure proposed in this paper, including a time constant regulator to mimic large machine time constants, are evaluated to emulate any IEEE 421.5 standard excitation system model or interface an industrial excitation system controller hardware in the loop (CHIL). It is shown that the communication delay introduced in CHIL does not impact the closed-loop stability within the bandwidth requirements of the excitation systems. One of the closed-loop structures, which is more generalized, and the open-loop structure performances are compared for emulating IEEE AC4C, DC1C, and ST1C excitation systems on a laboratory micro-machine based single machine infinite bus test system with buck exciter and H-bridge chopper (HBC) exciter using EMTP simulations under small and large disturbances. HBC exciter is used in the experimental validation with both the closed-loop and the open-loop control structures. The proposed open-loop structure is easy to implement and performs better than the closed-loop structure.
- 20 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2005, 1-6
Excitation Limiters Design for a Micro-Alternator Buck Converter Based Static Excitation System
This paper presents the design of excitation limiters such as an under-excitation limiter, over-excitation limiter and V/Hz limiter as per IEEE std 421.5 and implemented on a DC-DC buck converter-based static excitation system to protect the generator during abnormal conditions such as overloading, overheating and over-fluxing of the machine. A digital time constant regulator (TCR) is incorporated to modify the field’s time constant of micro-alternator, to mimic the dynamics of large synchronous machines. The detailed tuning procedure of limiters and TCR is discussed to comply with IEEE STD 421.2 and IEEE STD 421.5. The performance of the developed excitation system with limiters is tested under various small and large disturbances.
- 20 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2005, 1-6
Excitation Limiters Design for a Micro-Alternator Buck Converter Based Static Excitation System
This paper presents the design of excitation limiters such as an under-excitation limiter, over-excitation limiter and V/Hz limiter as per IEEE std 421.5 and implemented on a DC-DC buck converter-based static excitation system to protect the generator during abnormal conditions such as overloading, overheating and over-fluxing of the machine. A digital time constant regulator (TCR) is incorporated to modify the field’s time constant of micro-alternator, to mimic the dynamics of large synchronous machines. The detailed tuning procedure of limiters and TCR is discussed to comply with IEEE STD 421.2 and IEEE STD 421.5. The performance of the developed excitation system with limiters is tested under various small and large disturbances.
- 10 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (3) , 2185-2196
Anomaly-Aware Adaptive Sampling for Electrical Signal Compression
Intelligent electronic devices for power systems often entail high frequency sampling of electric signals, enabled to capture anomalous signal behavior. However, in normal operation this oversampling is redundant and leads to excessive data being stored or transmitted. This gives rise to a new compression problem where the collected samples should be further subsampled and quantized based on the presence of an anomaly in the underlying signal. We propose an Anomaly-aware Compressive Sampler (ACS) which tests the signal for the presence of an anomaly in a block of samples, and subsamples in a hierarchical manner to retain the desired sampling rate. ACS has been designed keeping hardware constraints in mind, using integer operations, an appropriate bit-packing, a simple iterated delta filter, and a streaming data pipeline. We present a mathematical formulation of the problem and analyze the performance of ACS, establishing theoretically its ability to identify anomalies in the signal and adapt the sampling rate. ACS competes with the state-of-the-art algorithm for the better-behaved transmission system data from DOE/EPRI, and outperforms it significantly on real-time distribution system data recorded in our laboratory. Finally, ACS is lightweight and was implemented on an ARM processor.
- 10 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (3) , 2185-2196
Anomaly-Aware Adaptive Sampling for Electrical Signal Compression
Intelligent electronic devices for power systems often entail high frequency sampling of electric signals, enabled to capture anomalous signal behavior. However, in normal operation this oversampling is redundant and leads to excessive data being stored or transmitted. This gives rise to a new compression problem where the collected samples should be further subsampled and quantized based on the presence of an anomaly in the underlying signal. We propose an Anomaly-aware Compressive Sampler (ACS) which tests the signal for the presence of an anomaly in a block of samples, and subsamples in a hierarchical manner to retain the desired sampling rate. ACS has been designed keeping hardware constraints in mind, using integer operations, an appropriate bit-packing, a simple iterated delta filter, and a streaming data pipeline. We present a mathematical formulation of the problem and analyze the performance of ACS, establishing theoretically its ability to identify anomalies in the signal and adapt the sampling rate. ACS competes with the state-of-the-art algorithm for the better-behaved transmission system data from DOE/EPRI, and outperforms it significantly on real-time distribution system data recorded in our laboratory. Finally, ACS is lightweight and was implemented on an ARM processor.