Durvesh Kalke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Durvesh Kalke has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Gurunath Gurrala
Department of Electrical Engineering, Indian Institute of Science, Bengaluru, India
3 shared publications - Radhakant Padhi
Department of Aerospace Engineering, Indian Institute of Science, Bengaluru, India
1 shared publication - Tanmay Mishra
Department of Electrical and Biomedical Engineering, University of Vermont, USA
1 shared publication
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 17 (4) , 1-14
Emulation of Ternary Pumped Storage Hydro Plants on a Laboratory Micro-Alternator
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 17 (4) , 1-14
Emulation of Ternary Pumped Storage Hydro Plants on a Laboratory Micro-Alternator
- 29 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (3) , 2191-2204
Synchronous Generator Emulation Using Output Matching Control Through Feedback Linearization
Micro-machines possessing parameters similar to those of large synchronous machines can be used to analyze the dynamic performance of the large machines in the laboratory. However, the scalability of the emulation experimental platform is constrained, given that a micro-machine can replicate solely the dynamics of a single turbo-generator. In this paper, an output matching controller based on the output feedback linearization technique has been proposed to emulate different synchronous machines on a single laboratory micro-machine. Synchronous generators with ratings of 128 MVA, 192 MVA, and 247.5 MVA have been emulated on a 5 kVA micro-machine. The IEEE 1.1 synchronous generator model is used as the reference machine model to be emulated. The dynamics observed in terminal voltage and the generator speed of the reference machine are emulated on the micro-machine. The efficacy of the proposed emulation approach is validated under both small and large disturbances created within the experimental testbed.
- 29 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 40 (3) , 2191-2204
Synchronous Generator Emulation Using Output Matching Control Through Feedback Linearization
Micro-machines possessing parameters similar to those of large synchronous machines can be used to analyze the dynamic performance of the large machines in the laboratory. However, the scalability of the emulation experimental platform is constrained, given that a micro-machine can replicate solely the dynamics of a single turbo-generator. In this paper, an output matching controller based on the output feedback linearization technique has been proposed to emulate different synchronous machines on a single laboratory micro-machine. Synchronous generators with ratings of 128 MVA, 192 MVA, and 247.5 MVA have been emulated on a 5 kVA micro-machine. The IEEE 1.1 synchronous generator model is used as the reference machine model to be emulated. The dynamics observed in terminal voltage and the generator speed of the reference machine are emulated on the micro-machine. The efficacy of the proposed emulation approach is validated under both small and large disturbances created within the experimental testbed.
- 8 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Design of IEC/IEEE 60255-118-1-2018 Compliant SOGI-PLL for Synchrophasor Measurements
A second-order generalized integrator (SOGI) phase-locked loop (PLL) with a linear quadratic regulator (LQR)-based bumpless compensator (BC) switching mechanism is proposed in this article for acquiring synchrophasor measurements compliant with IEC/IEEE 60255-118-1-2018. It has been shown that the SOGI-PLL, without any pre/post-filtering stages, requires two distinct ranges of parameter sets—Set-1 to satisfy steady-state scan, dynamic tests and Set-2 to meet out-of-band (OOB) and harmonic rejection (HR) tests. Therefore, the instance of switching the parameters must be ascertained along with a mechanism to switch between two sets of parameters. Hence, an LQR-based BC switching mechanism is proposed in this article to switch between two parameter sets. The input signal’s unwanted frequency components (harmonic or interharmonic frequency) are quantified using a notch filter and a moving average filter (MAF) to generate the switching signal that activates the transition between the two parameter sets. The performance of SOGI-PLL is tested under steady-state and dynamic test conditions as per IEC/IEEE 60255-118-1-2018 and compared with the enhanced PLL-based approach. The SOGI-PLL performance is found to be better than the enhanced PLL-based approach and is compliant with IEC/IEEE 60255-118-1-2018 under all specified tests. The performance is also tested with an actual voltage signal measured at the laboratory supply, and compliance with the standard was ascertained.
- 8 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Design of IEC/IEEE 60255-118-1-2018 Compliant SOGI-PLL for Synchrophasor Measurements
A second-order generalized integrator (SOGI) phase-locked loop (PLL) with a linear quadratic regulator (LQR)-based bumpless compensator (BC) switching mechanism is proposed in this article for acquiring synchrophasor measurements compliant with IEC/IEEE 60255-118-1-2018. It has been shown that the SOGI-PLL, without any pre/post-filtering stages, requires two distinct ranges of parameter sets—Set-1 to satisfy steady-state scan, dynamic tests and Set-2 to meet out-of-band (OOB) and harmonic rejection (HR) tests. Therefore, the instance of switching the parameters must be ascertained along with a mechanism to switch between two sets of parameters. Hence, an LQR-based BC switching mechanism is proposed in this article to switch between two parameter sets. The input signal’s unwanted frequency components (harmonic or interharmonic frequency) are quantified using a notch filter and a moving average filter (MAF) to generate the switching signal that activates the transition between the two parameter sets. The performance of SOGI-PLL is tested under steady-state and dynamic test conditions as per IEC/IEEE 60255-118-1-2018 and compared with the enhanced PLL-based approach. The SOGI-PLL performance is found to be better than the enhanced PLL-based approach and is compliant with IEC/IEEE 60255-118-1-2018 under all specified tests. The performance is also tested with an actual voltage signal measured at the laboratory supply, and compliance with the standard was ascertained.