Mykola Gomelya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mykola Gomelya has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
- Inna Trus
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute
23 shared publications - Tetyana Shabliy
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute
18 shared publications - Mariia Tverdokhlib
Department of Ecology and Technology of Plant Polymers, Faculty of Chemical Engineering, Igor Sikorsky Kyiv Polytechnic Institute, 37/4, Peremogy av., Kyiv 03056, Ukraine
9 shared publications - Vita Halysh
Igor Sikorsky Kyiv Polytechnic Institute 37 Prospect Beresteiskyi 03056 Kyiv Ukraine
9 shared publications - Olena Ivanenko
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute
7 shared publications - Ganna Trokhymenko
Admiral Makarov National University of Shipbuilding
5 shared publications
Latest Publications
- Open Access
- 28 September 2026
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Bulletin of National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute". Series "Chemical engineering, ecology and resource saving"
- No. 3,p. 68-78
Evaluating the impact of water acidification on deposit formation on the membrane during reverse osmosis desalination [in Ukrainian]
Providing environmentally safe drinking water and treating wastewater relies heavily on efficient desalination methods. Among these, low-pressure reverse osmosis (RO) is highly promising for residential and industrial water conditioning. However, a significant operational challenge remains scaling – the deposition of mineral precipitates on the membrane surface, which reduces membrane lifespan and efficiency. The primary aim of this research is to evaluate the performance of low-pressure RO membranes, specifically the Filmtec TW30-1812-75 model, during the desalination of municipal tap water. The study focuses on assessing the intensity of sediment deposition depending on the permeate recovery rate and the influence of water acidification on mitigating these deposits. The experimental study utilized a custom-designed laboratory reverse osmosis filtration unit operating at a constant pressure of 6.1 atm with a membrane specific flux of 0.0289 m/h. Tap water, characterized by an initial total hardness of 3.8-4.9 meq/dm3 and an alkalinity of 3.7-4.3 meq/dm3, was subjected to filtration. The permeate recovery rate was systematically varied from 40% up to 90%. To investigate the anti-scaling effect of pH adjustment, the feed water was acidified using hydrochloric acid (HCl) at doses of 1.25 meq/dm3 and 2.5 meq/dm3. Key physicochemical parameters, including total hardness, calcium and magnesium concentrations, total alkalinity, electrical conductivity, and pH, were rigorously monitored in both the permeate and the concentrate. To quantify the extent of scaling on the membrane surface, a mass balance approach was employed, comparing the theoretically calculated ion concentrations in the concentrate with the analytically measured values. The findings indicate that without pre-acidification, the low-pressure RO membrane exhibits excellent desalination efficiency, reducing the permeate hardness to 0.022-0.060 meq/dm3, which corresponds to a high selectivity of 98.75-99.45%. The residual alkalinity of the permeate decreased to 0.29-0.36 meq/dm3 (selectivity 91.43-93.1%). However, mass balance calculations revealed that scaling phenomena-primarily calcium carbonate precipitation-intensify substantially when the permeate recovery rate exceeds 65%. At a 90% recovery rate, the discrepancy between the theoretical and measured hardness in the concentrate reached 28.82 meq/dm3, confirming massive sediment deposition. The introduction of hydrochloric acid effectively lowered the initial alkalinity of the feed water, aiming to suppress carbonate scaling. With an HCl dose of 1.25 meq/dm3, the selectivity for hardness ions slightly decreased to 97.76-98.77%, and scaling was only partially mitigated. Increasing the HCl dose to 2.5 meq/dm3 reduced the feed water alkalinity to approximately 1.2 meq/dm3. While this aggressive acidification significantly inhibited calcium carbonate formation at moderate recovery rates, it did not completely resolve the scaling issue at the extreme recovery rate of 90%. At this threshold, the discrepancy in hardness still reached 14.84 meq/dm3. Due to the significant decrease in bicarbonate concentration and pH, there is a low probability of hardness ion precipitation using carbonates; therefore, the precipitation of other sparingly soluble salts, such as calcium sulfate (gypsum), likely occurred due to high concentration polarization. The practical significance of this work lies in defining the operational limits for low-pressure RO systems. It was established that operating below a 65% permeate recovery rate is critical to preventing severe scaling during standard tap water desalination. Acidification proves to be a viable method for increasing the recovery threshold by lowering alkalinity; however, it has limitations at very high recovery ratios due to the shifting solubility limits of non-carbonate scaling agents. Future investigations should focus on comparing the efficacy of polyphosphate, phosphonate, and sulfonate antiscalants to further optimize the stabilization of feed water in low-pressure RO applications.
- 28 September 2026
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Bulletin of National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute". Series "Chemical engineering, ecology and resource saving"
- No. 3,p. 68-78
Open AccessEvaluating the impact of water acidification on deposit formation on the membrane during reverse osmosis desalination [in Ukrainian]
Providing environmentally safe drinking water and treating wastewater relies heavily on efficient desalination methods. Among these, low-pressure reverse osmosis (RO) is highly promising for residential and industrial water conditioning. However, a significant operational challenge remains scaling – the deposition of mineral precipitates on the membrane surface, which reduces membrane lifespan and efficiency. The primary aim of this research is to evaluate the performance of low-pressure RO membranes, specifically the Filmtec TW30-1812-75 model, during the desalination of municipal tap water. The study focuses on assessing the intensity of sediment deposition depending on the permeate recovery rate and the influence of water acidification on mitigating these deposits. The experimental study utilized a custom-designed laboratory reverse osmosis filtration unit operating at a constant pressure of 6.1 atm with a membrane specific flux of 0.0289 m/h. Tap water, characterized by an initial total hardness of 3.8-4.9 meq/dm3 and an alkalinity of 3.7-4.3 meq/dm3, was subjected to filtration. The permeate recovery rate was systematically varied from 40% up to 90%. To investigate the anti-scaling effect of pH adjustment, the feed water was acidified using hydrochloric acid (HCl) at doses of 1.25 meq/dm3 and 2.5 meq/dm3. Key physicochemical parameters, including total hardness, calcium and magnesium concentrations, total alkalinity, electrical conductivity, and pH, were rigorously monitored in both the permeate and the concentrate. To quantify the extent of scaling on the membrane surface, a mass balance approach was employed, comparing the theoretically calculated ion concentrations in the concentrate with the analytically measured values. The findings indicate that without pre-acidification, the low-pressure RO membrane exhibits excellent desalination efficiency, reducing the permeate hardness to 0.022-0.060 meq/dm3, which corresponds to a high selectivity of 98.75-99.45%. The residual alkalinity of the permeate decreased to 0.29-0.36 meq/dm3 (selectivity 91.43-93.1%). However, mass balance calculations revealed that scaling phenomena-primarily calcium carbonate precipitation-intensify substantially when the permeate recovery rate exceeds 65%. At a 90% recovery rate, the discrepancy between the theoretical and measured hardness in the concentrate reached 28.82 meq/dm3, confirming massive sediment deposition. The introduction of hydrochloric acid effectively lowered the initial alkalinity of the feed water, aiming to suppress carbonate scaling. With an HCl dose of 1.25 meq/dm3, the selectivity for hardness ions slightly decreased to 97.76-98.77%, and scaling was only partially mitigated. Increasing the HCl dose to 2.5 meq/dm3 reduced the feed water alkalinity to approximately 1.2 meq/dm3. While this aggressive acidification significantly inhibited calcium carbonate formation at moderate recovery rates, it did not completely resolve the scaling issue at the extreme recovery rate of 90%. At this threshold, the discrepancy in hardness still reached 14.84 meq/dm3. Due to the significant decrease in bicarbonate concentration and pH, there is a low probability of hardness ion precipitation using carbonates; therefore, the precipitation of other sparingly soluble salts, such as calcium sulfate (gypsum), likely occurred due to high concentration polarization. The practical significance of this work lies in defining the operational limits for low-pressure RO systems. It was established that operating below a 65% permeate recovery rate is critical to preventing severe scaling during standard tap water desalination. Acidification proves to be a viable method for increasing the recovery threshold by lowering alkalinity; however, it has limitations at very high recovery ratios due to the shifting solubility limits of non-carbonate scaling agents. Future investigations should focus on comparing the efficacy of polyphosphate, phosphonate, and sulfonate antiscalants to further optimize the stabilization of feed water in low-pressure RO applications.
- Open Access
- 9 August 2026
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Матеріали міжнародної науково-практиченої конференції "Екологія. Людина. Суспільство"
- p. 236-241
Dynamics of scaling on low-pressure reverse osmosis membranes and prospects of reagent water stabilization
This paper addresses the acute problem of intensive carbonate scaling on low-pressure membranes during reverse osmosis softening of tap water. The scaling dynamics were studied on a Filmtec TW30-1812-75 spiral-wound membrane (operating pressure 6.1 atm, permeate recovery rate 40–90%). Scaling intensity was evaluated by comparing actual ion concentrations with those calculated based on the material balance. It was found that at a permeate recovery rate above 65%, a sharp deficit of calcium ions occurs in the concentrate (discrepancy up to 26.42 mg-eq/dm³ at 90% conversion), indicating their transition into the solid phase. This process was shown to be stimulated by an increase in the concentrate pH to 8.20 due to the transmembrane mass transfer of non-hydrated free carbon dioxide. The necessity of reagent water stabilization is theoretically justified. Dosed acidification allows shifting the carbon dioxide equilibrium, keeping carbon in a soluble form, which represents an effective approach to prevent scaling without the use of antiscalants.
- 9 August 2026
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Матеріали міжнародної науково-практиченої конференції "Екологія. Людина. Суспільство"
- p. 236-241
Open AccessDynamics of scaling on low-pressure reverse osmosis membranes and prospects of reagent water stabilization
This paper addresses the acute problem of intensive carbonate scaling on low-pressure membranes during reverse osmosis softening of tap water. The scaling dynamics were studied on a Filmtec TW30-1812-75 spiral-wound membrane (operating pressure 6.1 atm, permeate recovery rate 40–90%). Scaling intensity was evaluated by comparing actual ion concentrations with those calculated based on the material balance. It was found that at a permeate recovery rate above 65%, a sharp deficit of calcium ions occurs in the concentrate (discrepancy up to 26.42 mg-eq/dm³ at 90% conversion), indicating their transition into the solid phase. This process was shown to be stimulated by an increase in the concentrate pH to 8.20 due to the transmembrane mass transfer of non-hydrated free carbon dioxide. The necessity of reagent water stabilization is theoretically justified. Dosed acidification allows shifting the carbon dioxide equilibrium, keeping carbon in a soluble form, which represents an effective approach to prevent scaling without the use of antiscalants.
- Open Access
- 9 August 2026
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Матеріали міжнародної науково-практиченої конференції "Екологія. Людина. Суспільство"
- p. 228-235
Iron-based catalysts for the deoxygenation of water with sodium metabisulfite
The study investigates the process of water deoxygenation using sodium metabisulfite in the presence of iron-based catalysts. A magnetite catalyst based on the KU-2-8 cation-exchange resin was synthesized, and its efficiency was compared with that of iron shavings in distilled, sodium-cationized, and tap water. The results showed that the efficiency of deoxygenation depends on both the water composition and the type of catalyst. Iron shavings demonstrated the highest catalytic activity, reducing the oxygen removal time to 90–660 seconds, whereas the magnetite catalyst provided moderate process acceleration with minimal iron leaching into the water.
- 9 August 2026
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Матеріали міжнародної науково-практиченої конференції "Екологія. Людина. Суспільство"
- p. 228-235
Open AccessIron-based catalysts for the deoxygenation of water with sodium metabisulfite
The study investigates the process of water deoxygenation using sodium metabisulfite in the presence of iron-based catalysts. A magnetite catalyst based on the KU-2-8 cation-exchange resin was synthesized, and its efficiency was compared with that of iron shavings in distilled, sodium-cationized, and tap water. The results showed that the efficiency of deoxygenation depends on both the water composition and the type of catalyst. Iron shavings demonstrated the highest catalytic activity, reducing the oxygen removal time to 90–660 seconds, whereas the magnetite catalyst provided moderate process acceleration with minimal iron leaching into the water.
- Open Access
- 29 December 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Bulletin of National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute". Series "Chemical engineering, ecology and resource saving"
- No. 4,p. 75-84
Evaluation of the efficiency of tap water softening using low-pressure reverse osmosis membranes [in Ukrainian]
The study investigates the processes of tap water softening using a reverse osmosis system equipped with a low-pressure membrane Filmtec TW30-1812-75. The aim of the research was to determine the efficiency of low-pressure reverse osmosis membranes for freshwater softening and to assess the influence of water hardness on scale formation on the membrane surface depending on filtrate volume and permeate recovery rate. During the experiments, tap water with an initial hardness of 4.0–4.8 mg-eq/dm³ was treated under a working pressure of 6.1 atm and a membrane productivity of 0.0289 m³/h. The study was conducted at permeate recovery rates of 40 %, 50 %, 65 %, 75 %, and 90 %. To evaluate the process, pH, electrical conductivity, total hardness, alkalinity, and concentrations of calcium and magnesium ions were measured in both the permeate and concentrate. Experimental data were compared with theoretically calculated concentrations in the concentrate. The results showed that the Filmtec TW30-1812-75 membrane exhibited high selectivity toward hardness ions (98–99 %) compared with bicarbonate anions responsible for water alkalinity. As the permeate recovery increased, the selectivity for bicarbonates gradually decreased—from 94.8 % at 40 % recovery to 91 % at 90 %. It was also found that with an increase in the volume of permeate collected, the difference between calculated and measured concentrations of hardness and alkalinity grew, with actual values being lower than theoretical ones. This indicates the deposition of calcium ions in the form of calcium carbonate (CaCO₃) on the membrane surface. The most intensive scaling was observed at recovery rates above 75 %. At lower recovery degrees, permeate quality remained stable, and concentration variations corresponded to expected values. The Filmtec TW30-1812-75 membrane provides effective reduction of water hardness and alkalinity while maintaining stable purification performance within the studied operating range. At recovery rates exceeding 75 %, the risk of scale formation increases, which should be considered when predicting and optimizing the operation of reverse osmosis systems.
- 29 December 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Bulletin of National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute". Series "Chemical engineering, ecology and resource saving"
- No. 4,p. 75-84
Open AccessEvaluation of the efficiency of tap water softening using low-pressure reverse osmosis membranes [in Ukrainian]
The study investigates the processes of tap water softening using a reverse osmosis system equipped with a low-pressure membrane Filmtec TW30-1812-75. The aim of the research was to determine the efficiency of low-pressure reverse osmosis membranes for freshwater softening and to assess the influence of water hardness on scale formation on the membrane surface depending on filtrate volume and permeate recovery rate. During the experiments, tap water with an initial hardness of 4.0–4.8 mg-eq/dm³ was treated under a working pressure of 6.1 atm and a membrane productivity of 0.0289 m³/h. The study was conducted at permeate recovery rates of 40 %, 50 %, 65 %, 75 %, and 90 %. To evaluate the process, pH, electrical conductivity, total hardness, alkalinity, and concentrations of calcium and magnesium ions were measured in both the permeate and concentrate. Experimental data were compared with theoretically calculated concentrations in the concentrate. The results showed that the Filmtec TW30-1812-75 membrane exhibited high selectivity toward hardness ions (98–99 %) compared with bicarbonate anions responsible for water alkalinity. As the permeate recovery increased, the selectivity for bicarbonates gradually decreased—from 94.8 % at 40 % recovery to 91 % at 90 %. It was also found that with an increase in the volume of permeate collected, the difference between calculated and measured concentrations of hardness and alkalinity grew, with actual values being lower than theoretical ones. This indicates the deposition of calcium ions in the form of calcium carbonate (CaCO₃) on the membrane surface. The most intensive scaling was observed at recovery rates above 75 %. At lower recovery degrees, permeate quality remained stable, and concentration variations corresponded to expected values. The Filmtec TW30-1812-75 membrane provides effective reduction of water hardness and alkalinity while maintaining stable purification performance within the studied operating range. At recovery rates exceeding 75 %, the risk of scale formation increases, which should be considered when predicting and optimizing the operation of reverse osmosis systems.
- Open Access
- 10 November 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Матеріали міжнародної науково-практиченої конференції "Екологія. Людина. Суспільство"
- p. 249-252
Infrared spectroscopy in the research of structural features of membranes made of modified cellulose fiber
This study explores the use of modified cellulose membranes for water purification, focusing on the removal of color from sodium humate solutions. Cellulose, a renewable and eco-friendly polymer, was modified with a 1:1 mixture of monoethanolamine and epichlorohydrin at consumption of 5%, 10%, and 15%. The membranes (80 g/m²) were tested on 100 mg/dm³ sodium humate solutions. Color removal efficiency was highest (98%) with the 15% modified membrane. The infrared spectra confirmed successful modification by the appearance of a peak at 1598 cm⁻¹. The results demonstrate the potential of chemically modified cellulose membranes for sustainable water treatment applications.
- 10 November 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Матеріали міжнародної науково-практиченої конференції "Екологія. Людина. Суспільство"
- p. 249-252
Open AccessInfrared spectroscopy in the research of structural features of membranes made of modified cellulose fiber
This study explores the use of modified cellulose membranes for water purification, focusing on the removal of color from sodium humate solutions. Cellulose, a renewable and eco-friendly polymer, was modified with a 1:1 mixture of monoethanolamine and epichlorohydrin at consumption of 5%, 10%, and 15%. The membranes (80 g/m²) were tested on 100 mg/dm³ sodium humate solutions. Color removal efficiency was highest (98%) with the 15% modified membrane. The infrared spectra confirmed successful modification by the appearance of a peak at 1598 cm⁻¹. The results demonstrate the potential of chemically modified cellulose membranes for sustainable water treatment applications.
- Open Access
- 10 November 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Матеріали міжнародної науково-практиченої конференції "Екологія. Людина. Суспільство"
- p. 230-233
Obtaining oxidized chlorine compounds from sodium chloride solutions by electrodialysis
This work is devoted to the study of the processes of processing sodium chloride solutions, close in composition to reverse osmosis water desalination concentrates, by the electrodialysis method. When conducting electrolysis of solutions, open two-chamber electrolyzers were used. Solutions with sodium chlorides were placed in the anode chamber, and the cathode chamber was filled with alkali solutions with a concentration of 200-1000 mg-eq/dm3. Electrolysis in an open two-chamber electrolyzer was carried out using sodium chloride solutions with a chloride concentration from 60 to 1725 mg-eq/dm3. In this case, an anion exchange membrane MA-41 was used. The cathode was made of alloyed steel 12X18H10T, the anode was made of a titanium plate coated with ruthenium oxide. The area of the electrodes Sa = Sk = 12 cm2. The cathode chamber was filled with 0.2 N NaOH solution; the anode region – with a working solution of sodium chloride. At a given current strength, the electrolysis process was carried out for 2-8 hours, periodically monitoring the alkalinity in the catholyte, the content of chlorides and active chlorine in the anolyte.
- 10 November 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Матеріали міжнародної науково-практиченої конференції "Екологія. Людина. Суспільство"
- p. 230-233
Open AccessObtaining oxidized chlorine compounds from sodium chloride solutions by electrodialysis
This work is devoted to the study of the processes of processing sodium chloride solutions, close in composition to reverse osmosis water desalination concentrates, by the electrodialysis method. When conducting electrolysis of solutions, open two-chamber electrolyzers were used. Solutions with sodium chlorides were placed in the anode chamber, and the cathode chamber was filled with alkali solutions with a concentration of 200-1000 mg-eq/dm3. Electrolysis in an open two-chamber electrolyzer was carried out using sodium chloride solutions with a chloride concentration from 60 to 1725 mg-eq/dm3. In this case, an anion exchange membrane MA-41 was used. The cathode was made of alloyed steel 12X18H10T, the anode was made of a titanium plate coated with ruthenium oxide. The area of the electrodes Sa = Sk = 12 cm2. The cathode chamber was filled with 0.2 N NaOH solution; the anode region – with a working solution of sodium chloride. At a given current strength, the electrolysis process was carried out for 2-8 hours, periodically monitoring the alkalinity in the catholyte, the content of chlorides and active chlorine in the anolyte.
- Open Access
- 10 November 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Матеріали міжнародної науково-практиченої конференції "Екологія. Людина. Суспільство"
- p. 192-195
Assessment of the impact of operational parameters on the efficiency of reverse osmosis systems
This paper addresses the pressing issue of water quality assurance under increasing anthropogenic pressure. The efficiency of reverse osmosis (RO) technology for water purification, particularly in the pharmaceutical industry, is analyzed. Data concerning the impact of key operational parameters (pressure, recovery rate) and physico-chemical characteristics of feedwater (pH, hardness, alkalinity) on membrane purification efficiency are systematized. Particular attention is given to the problems of membrane scaling, especially in regions with high concentrations of hardness salts. Methods for assessing water's scaling tendency (LSI, SDI indices), monitoring strategies, and water pre-conditioning, including antiscalant dosing (phosphonates, polyacrylic acid) and pH adjustment, are examined. Modern approaches to optimizing RO systems, such as the use of digital twins and hybrid technologies (RO-UV, RO-ED), which contribute to improved purification quality, energy efficiency, and reduced fouling risks, are also highlighted. Recommendations are proposed for optimizing operational parameters, developing water stability assessment methodologies, and implementing monitoring systems to ensure the long-term efficiency of reverse osmosis systems.
- 10 November 2025
- Published by Igor Sikorsky Kyiv Polytechnic Institute in Матеріали міжнародної науково-практиченої конференції "Екологія. Людина. Суспільство"
- p. 192-195
Open AccessAssessment of the impact of operational parameters on the efficiency of reverse osmosis systems
This paper addresses the pressing issue of water quality assurance under increasing anthropogenic pressure. The efficiency of reverse osmosis (RO) technology for water purification, particularly in the pharmaceutical industry, is analyzed. Data concerning the impact of key operational parameters (pressure, recovery rate) and physico-chemical characteristics of feedwater (pH, hardness, alkalinity) on membrane purification efficiency are systematized. Particular attention is given to the problems of membrane scaling, especially in regions with high concentrations of hardness salts. Methods for assessing water's scaling tendency (LSI, SDI indices), monitoring strategies, and water pre-conditioning, including antiscalant dosing (phosphonates, polyacrylic acid) and pH adjustment, are examined. Modern approaches to optimizing RO systems, such as the use of digital twins and hybrid technologies (RO-UV, RO-ED), which contribute to improved purification quality, energy efficiency, and reduced fouling risks, are also highlighted. Recommendations are proposed for optimizing operational parameters, developing water stability assessment methodologies, and implementing monitoring systems to ensure the long-term efficiency of reverse osmosis systems.
- Open Access
- 1 June 2025
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Ecological Engineering & Environmental Technology
- Vol. 26 (6) , 98-107
Synthesis of oxidized chlorine compounds by electrodialysis using a strongly basic anion exchange resin
The work investigated processes for treating solutions similar in composition to concentrates obtained from reverse-osmosis desalination of water containing sodium chloride, using the method of electrodialysis. Two-chamber electrolyzers equipped with MA-41 anion membranes were used to electrolyze...
- 1 June 2025
- Published by Wydawnictwo Naukowe Gabriel Borowski (WNGB) in Ecological Engineering & Environmental Technology
- Vol. 26 (6) , 98-107
Open AccessSynthesis of oxidized chlorine compounds by electrodialysis using a strongly basic anion exchange resin
The work investigated processes for treating solutions similar in composition to concentrates obtained from reverse-osmosis desalination of water containing sodium chloride, using the method of electrodialysis. Two-chamber electrolyzers equipped with MA-41 anion membranes were used to electrolyze...
- Open Access
- 16 May 2025
- Published by Private Company Technology Center in Technology audit and production reserves
- Vol. 3 (3(83)) , 17-24
Development of a method for processing concentrates from water desalination processes to obtain aluminum coagulants
The process of processing concentrates and eluates formed during desalination of natural surface, artesian, and mine waters with increased mineralization by reverse osmosis and ion exchange methods has been studied. Specifically, this study examined the processes of processing sodium chloride solutions and mixtures of sodium chloride and sodium sulfate via electrodialysis, and obtaining alkaline and aluminum salt solutions, were examined. Aluminum salts were produced using AD-31 aluminum anodes. A stainless-steel plate of grade 12H18N10T was used as the cathode. The process was conducted at current densities ranging from 1.67 to 8.33 A/dm² in two- and three-chamber electrolyzers using MK-40 cation-exchange membranes and MA-41 anion-exchange membranes. In all experiments, alkaline solutions were obtained in the cathode region and aluminum salt solutions in the anode region. When using a three-chamber electrolyzer, the salt solution was placed in the working chamber, separated by a cation-exchange membrane from the catholyte and an anion-exchange membrane from the anode zone. During electrolysis, alkali concentration occurred in the catholyte and aluminum salts in the anolyte. In the three-chamber electrolyzer, desalination occurred in the working chamber due to the diffusion of sodium ions through the cation-exchange membrane into the catholyte and the diffusion of anions (chlorides and sulfates) through the anion-exchange membrane into the anode area. Aluminum oxidation in the anode area resulted in the formation of Al³⁺ cations, and in the presence of chlorides, aluminum chloride was formed. Hydrolysis of aluminum chloride partially produced aluminum hydroxychlorides, predominantly forming 1/3 aluminum hydroxychloride. Before electrolysis, the anode chamber pH was adjusted to 2.5 with hydrochloric acid. During electrolysis, the pH was maintained at 2.5–3 due to electrode reactions. The salt content in the working chamber decreased to 2–20 mg-eq/dm³. In a two-chamber electrolyzer, electrolysis produced alkali in the catholyte and aluminum chloride in the anolyte. Conversion of sodium chloride in the anolyte was limited due to poisoning of the cation-exchange membrane by aluminum ions.
- 16 May 2025
- Published by Private Company Technology Center in Technology audit and production reserves
- Vol. 3 (3(83)) , 17-24
Open AccessDevelopment of a method for processing concentrates from water desalination processes to obtain aluminum coagulants
The process of processing concentrates and eluates formed during desalination of natural surface, artesian, and mine waters with increased mineralization by reverse osmosis and ion exchange methods has been studied. Specifically, this study examined the processes of processing sodium chloride solutions and mixtures of sodium chloride and sodium sulfate via electrodialysis, and obtaining alkaline and aluminum salt solutions, were examined. Aluminum salts were produced using AD-31 aluminum anodes. A stainless-steel plate of grade 12H18N10T was used as the cathode. The process was conducted at current densities ranging from 1.67 to 8.33 A/dm² in two- and three-chamber electrolyzers using MK-40 cation-exchange membranes and MA-41 anion-exchange membranes. In all experiments, alkaline solutions were obtained in the cathode region and aluminum salt solutions in the anode region. When using a three-chamber electrolyzer, the salt solution was placed in the working chamber, separated by a cation-exchange membrane from the catholyte and an anion-exchange membrane from the anode zone. During electrolysis, alkali concentration occurred in the catholyte and aluminum salts in the anolyte. In the three-chamber electrolyzer, desalination occurred in the working chamber due to the diffusion of sodium ions through the cation-exchange membrane into the catholyte and the diffusion of anions (chlorides and sulfates) through the anion-exchange membrane into the anode area. Aluminum oxidation in the anode area resulted in the formation of Al³⁺ cations, and in the presence of chlorides, aluminum chloride was formed. Hydrolysis of aluminum chloride partially produced aluminum hydroxychlorides, predominantly forming 1/3 aluminum hydroxychloride. Before electrolysis, the anode chamber pH was adjusted to 2.5 with hydrochloric acid. During electrolysis, the pH was maintained at 2.5–3 due to electrode reactions. The salt content in the working chamber decreased to 2–20 mg-eq/dm³. In a two-chamber electrolyzer, electrolysis produced alkali in the catholyte and aluminum chloride in the anolyte. Conversion of sodium chloride in the anolyte was limited due to poisoning of the cation-exchange membrane by aluminum ions.
- Open Access
- 7 March 2025
- Published by University of Chemical Technology and Metallurgy in Journal of Chemical Technology and Metallurgy
- Vol. 60 (2) , 259-268
AMMONIA REMOVAL FROM WATER USING CATIONIC MATERIALS KU-2-8 AND DOWEX MAC-3
In this work, it is shown that theareighest efficiency of ammonium extraction from water using cationites KU-2-8 and DOWEX MAC-3 is achieved when they are used in their acidic form. It has been established that hardness ions, namely calcium and magnesium ions, complicate the process of ion-exchange ammonium extraction, since these cationites have a higher selectivity for hardness ions. The highest level of regeneration of cationite KU-2-8 was found by using acid solutions compared to sodium chloride solutions. The use of phosphoric and nitric acid solutions for regeneration will allow further use of regeneration solutions for fertiliser production.
- 7 March 2025
- Published by University of Chemical Technology and Metallurgy in Journal of Chemical Technology and Metallurgy
- Vol. 60 (2) , 259-268
Open AccessAMMONIA REMOVAL FROM WATER USING CATIONIC MATERIALS KU-2-8 AND DOWEX MAC-3
In this work, it is shown that theareighest efficiency of ammonium extraction from water using cationites KU-2-8 and DOWEX MAC-3 is achieved when they are used in their acidic form. It has been established that hardness ions, namely calcium and magnesium ions, complicate the process of ion-exchange ammonium extraction, since these cationites have a higher selectivity for hardness ions. The highest level of regeneration of cationite KU-2-8 was found by using acid solutions compared to sodium chloride solutions. The use of phosphoric and nitric acid solutions for regeneration will allow further use of regeneration solutions for fertiliser production.