Klaudia Hradil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Klaudia Hradil has a total of 313 co-authors. Here are the top co-authors by number of shared publications:
Y. Sidis
Laboratoire Léon Brillouin, CEA-CNRS, CEA-Saclay, 91191 Gif sur Yvette, France
6 shared publicationsF. Frey
5 shared publicationsR. A. Mole
ANSTO
5 shared publicationsB. Keimer
4 shared publicationsC. T. Lin
4 shared publications- Christina Streli
Atominstitut, TU Wien, Stadionallee 2, 1020 Vienna, Austria
4 shared publications
Latest Publications
- Open Access
- 1 November 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (11)
The x-ray color camera microscope—A combined x-ray diffraction and fluorescence analysis instrument suitable for lab and synchrotron use
X-ray spectroscopy has been among the most important and precise material characterization techniques for multiple decades, with a wide range of applications from material sciences to medical research or cultural heritage. With the rising capabilities of laboratory x-ray sources and novel detectors, new techniques become possible. The x-ray Color Camera Microscope combines a state-of-the-art laboratory source with a large, pixelated energy dispersive pnCCD detector, where every pixel yields an independent energy spectrum. In addition, it can be used at a synchrotron as well, in case higher flux is needed. The full beam path is in vacuum and the detector completely unshielded, guaranteeing the detection of low energy photons and effectively minimizing parasitic background scattering and absorption. Very high scattering angles up to 70° can be reached by moving the detector very close to the sample, making it useful for a variety of techniques. Two techniques will be presented, both profiting from the special setup of the instrument. Full-field fluorescence imaging can yield a spatially resolved elemental map of a sample without the need of scanning it with a microscopic beam. Energy dispersive Laue diffraction uses a polychromatic beam and allows three-dimensional crystallographic data of a sample to be obtained in a single shot. With the above options and the possibility of other techniques, the x-ray Color Camera Microscope becomes a versatile energy dispersive x-ray imaging instrument for use in the laboratory and at synchrotrons.
- 1 November 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (11)
Open AccessThe x-ray color camera microscope—A combined x-ray diffraction and fluorescence analysis instrument suitable for lab and synchrotron use
X-ray spectroscopy has been among the most important and precise material characterization techniques for multiple decades, with a wide range of applications from material sciences to medical research or cultural heritage. With the rising capabilities of laboratory x-ray sources and novel detectors, new techniques become possible. The x-ray Color Camera Microscope combines a state-of-the-art laboratory source with a large, pixelated energy dispersive pnCCD detector, where every pixel yields an independent energy spectrum. In addition, it can be used at a synchrotron as well, in case higher flux is needed. The full beam path is in vacuum and the detector completely unshielded, guaranteeing the detection of low energy photons and effectively minimizing parasitic background scattering and absorption. Very high scattering angles up to 70° can be reached by moving the detector very close to the sample, making it useful for a variety of techniques. Two techniques will be presented, both profiting from the special setup of the instrument. Full-field fluorescence imaging can yield a spatially resolved elemental map of a sample without the need of scanning it with a microscopic beam. Energy dispersive Laue diffraction uses a polychromatic beam and allows three-dimensional crystallographic data of a sample to be obtained in a single shot. With the above options and the possibility of other techniques, the x-ray Color Camera Microscope becomes a versatile energy dispersive x-ray imaging instrument for use in the laboratory and at synchrotrons.
- Open Access
- 1 August 2025
- Published by Wiley in X-Ray Spectrometry
- Vol. 55 (1) , 2-12
Elemental Mapping of Historical Daguerreotypes Using Monochromatic Micro‐ XRF : Imaging, Degradation, and Conservation Potential
The daguerreotype, introduced by Louis‐Jacques‐Mandé Daguerre in 1839, marked the beginning of photography. This early photographic process, based on halide‐sensitized silver‐coated copper plates developed with mercury vapor, produces highly reflective, image‐bearing surfaces that are both visually unique and chemically complex. As part of the interdisciplinary Heritage Science project PHELETYPIA, this study investigates the surface morphology and elemental composition of two historical daguerreotypes from the Varaždin City Museum (Croatia) using monochromatic micro‐x‐ray fluorescence (μXRF), scanning electron microscopy with energy‐dispersive x‐ray spectrometry (SEM/EDS), and optical microscopy. By comparing elemental distribution maps based on Hg‐L and Au‐L lines, we assess the relationship between image particle composition, visual contrast, and degradation patterns. Our results suggest that differences in image formation and preservation are linked to original manufacturing processes, including uneven thermal development and subsequent environmental exposure. High‐resolution elemental imaging reveals how visual information is distributed across tonal zones and how it may be affected by previous conservation interventions. These findings highlight the potential of non‐invasive analytical imaging to enhance our understanding of daguerreotype image structure, support condition assessment, and inform long‐term digital preservation strategies.
- 1 August 2025
- Published by Wiley in X-Ray Spectrometry
- Vol. 55 (1) , 2-12
Open AccessElemental Mapping of Historical Daguerreotypes Using Monochromatic Micro‐ XRF : Imaging, Degradation, and Conservation Potential
The daguerreotype, introduced by Louis‐Jacques‐Mandé Daguerre in 1839, marked the beginning of photography. This early photographic process, based on halide‐sensitized silver‐coated copper plates developed with mercury vapor, produces highly reflective, image‐bearing surfaces that are both visually unique and chemically complex. As part of the interdisciplinary Heritage Science project PHELETYPIA, this study investigates the surface morphology and elemental composition of two historical daguerreotypes from the Varaždin City Museum (Croatia) using monochromatic micro‐x‐ray fluorescence (μXRF), scanning electron microscopy with energy‐dispersive x‐ray spectrometry (SEM/EDS), and optical microscopy. By comparing elemental distribution maps based on Hg‐L and Au‐L lines, we assess the relationship between image particle composition, visual contrast, and degradation patterns. Our results suggest that differences in image formation and preservation are linked to original manufacturing processes, including uneven thermal development and subsequent environmental exposure. High‐resolution elemental imaging reveals how visual information is distributed across tonal zones and how it may be affected by previous conservation interventions. These findings highlight the potential of non‐invasive analytical imaging to enhance our understanding of daguerreotype image structure, support condition assessment, and inform long‐term digital preservation strategies.
- 29 July 2025
- Published by Elsevier in Tribology International
- Vol. 213
A compact tribometer setup for in-situ investigation of tribological contacts using X-ray diffraction
- 29 July 2025
- Published by Elsevier in Tribology International
- Vol. 213
A compact tribometer setup for in-situ investigation of tribological contacts using X-ray diffraction
- 8 October 2024
- Published by Elsevier in Journal of Cultural Heritage
- Vol. 70, 223-230
Surface characterization of Austrian daguerreotype portraits
- 8 October 2024
- Published by Elsevier in Journal of Cultural Heritage
- Vol. 70, 223-230
Surface characterization of Austrian daguerreotype portraits
- Open Access
- 8 January 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-9
Multi-scale characterisation of a ferroelectric polymer reveals the emergence of a morphological phase transition driven by temperature
Ferroelectric materials exhibit a phase transition to a paraelectric state driven by temperature - called the Curie transition. In conventional ferroelectrics, the Curie transition is caused by a change in crystal symmetry, while the material itself remains a continuous three-dimensional solid crystal. However, ferroelectric polymers behave differently. Polymeric materials are typically of semi-crystalline nature, meaning that they are an intermixture of crystalline and amorphous regions. Here, we demonstrate that the semi-crystalline morphology of the ferroelectric copolymer of vinylidene fluoride and trifluoroethylene (P(VDF-TrFE)) strongly affects its Curie transition, as not only a change in crystal symmetry but also in morphology occurs. We demonstrate, by high-resolution nanomechanical measurements, that the semi-crystalline microstructure in the paraelectric state is formed by crystalline domains embedded into a softer amorphous phase. Using in situ X-ray diffraction measurements, we show that the local electromechanical response of the crystalline domains is counterbalanced by the amorphous phase, effectively masking its macroscopic effect. Our quantitative multi-scale characterisations unite the nano- and macroscopic material properties of the ferroelectric polymer P(VDF-TrFE) through its semi-crystalline nature.
- 8 January 2021
- Published by Springer Nature in Nature Communications
- Vol. 12 (1) , 1-9
Open AccessMulti-scale characterisation of a ferroelectric polymer reveals the emergence of a morphological phase transition driven by temperature
Ferroelectric materials exhibit a phase transition to a paraelectric state driven by temperature - called the Curie transition. In conventional ferroelectrics, the Curie transition is caused by a change in crystal symmetry, while the material itself remains a continuous three-dimensional solid crystal. However, ferroelectric polymers behave differently. Polymeric materials are typically of semi-crystalline nature, meaning that they are an intermixture of crystalline and amorphous regions. Here, we demonstrate that the semi-crystalline morphology of the ferroelectric copolymer of vinylidene fluoride and trifluoroethylene (P(VDF-TrFE)) strongly affects its Curie transition, as not only a change in crystal symmetry but also in morphology occurs. We demonstrate, by high-resolution nanomechanical measurements, that the semi-crystalline microstructure in the paraelectric state is formed by crystalline domains embedded into a softer amorphous phase. Using in situ X-ray diffraction measurements, we show that the local electromechanical response of the crystalline domains is counterbalanced by the amorphous phase, effectively masking its macroscopic effect. Our quantitative multi-scale characterisations unite the nano- and macroscopic material properties of the ferroelectric polymer P(VDF-TrFE) through its semi-crystalline nature.
- 1 December 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (12) , 123107
A monochromatic confocal micro-x-ray fluorescence (μXRF) spectrometer for the lab
Confocal micro-x-ray fluorescence (μXRF) is a powerful tool to analyze the spatial distribution of major, minor, and trace elements in three dimensions. Typical (confocal) μXRF measurements in the lab use polychromatic excitation, complicating quantification and fundamental parameter-based corrections and furthermore deteriorating peak-to-background ratios due to scattered bremsstrahlung. The goal for the new setup was to remedy these problems, without sacrificing spatial resolution, and keep it flexible for different excitation energies and transportation to other sources. The source assembly consists of a water-cooled fine-focus x-ray diffraction tube and a parallel beam-mirror, which produces a quasi-parallel, monochromatic beam. The presented results were obtained using a 2 kW molybdenum tube and a mirror for Mo-Kα. The confocal setup itself consists of two polycapillary half-lenses, one for the source side and the other for the detector side, where a 50 mm2 silicon drift detector is mounted. Both polycapillaries have a focus size of ∼15 μm for Mo-Kα. The second polycapillary can also be exchanged for a custom-designed collimator in order to perform non-confocal μXRF. Details of the technical setup and results from technical and biological samples are presented. Detection limits for selected elements from Ca to Pb in the confocal and non-confocal mode were established (e.g., 1 μg/g non-confocal and 20 μg/g confocal for As) using the NIST standard reference materials (SRMs) 621 and 1412. Furthermore, the results of the measurements of SRM 621 were evaluated using the fundamental parameter based quantification software ATI-QUANT. The results are compared with the certified values and generally are in good agreement.
- 1 December 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (12) , 123107
A monochromatic confocal micro-x-ray fluorescence (μXRF) spectrometer for the lab
Confocal micro-x-ray fluorescence (μXRF) is a powerful tool to analyze the spatial distribution of major, minor, and trace elements in three dimensions. Typical (confocal) μXRF measurements in the lab use polychromatic excitation, complicating quantification and fundamental parameter-based corrections and furthermore deteriorating peak-to-background ratios due to scattered bremsstrahlung. The goal for the new setup was to remedy these problems, without sacrificing spatial resolution, and keep it flexible for different excitation energies and transportation to other sources. The source assembly consists of a water-cooled fine-focus x-ray diffraction tube and a parallel beam-mirror, which produces a quasi-parallel, monochromatic beam. The presented results were obtained using a 2 kW molybdenum tube and a mirror for Mo-Kα. The confocal setup itself consists of two polycapillary half-lenses, one for the source side and the other for the detector side, where a 50 mm2 silicon drift detector is mounted. Both polycapillaries have a focus size of ∼15 μm for Mo-Kα. The second polycapillary can also be exchanged for a custom-designed collimator in order to perform non-confocal μXRF. Details of the technical setup and results from technical and biological samples are presented. Detection limits for selected elements from Ca to Pb in the confocal and non-confocal mode were established (e.g., 1 μg/g non-confocal and 20 μg/g confocal for As) using the NIST standard reference materials (SRMs) 621 and 1412. Furthermore, the results of the measurements of SRM 621 were evaluated using the fundamental parameter based quantification software ATI-QUANT. The results are compared with the certified values and generally are in good agreement.
- Open Access
- 2 December 2019
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 123 (23) , 235501
Phonon Lifetimes throughout the Brillouin Zone at Elevated Temperatures from Experiment andAb Initio
We obtain phonon lifetimes in aluminium by inelastic neutron scattering experiments, by ab initio molecular dynamics, and by perturbation theory. At elevated temperatures significant discrepancies are found between experiment and perturbation theory, which disappear when using molecular dynamics due to the inclusion of full anharmonicity and the correct treatment of the multiphonon background. We show that multiple-site interactions are small and that local pairwise anharmonicity dominates phonon-phonon interactions, which permits an efficient computation of phonon lifetimes.
- 2 December 2019
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 123 (23) , 235501
Open AccessPhonon Lifetimes throughout the Brillouin Zone at Elevated Temperatures from Experiment andAb Initio
We obtain phonon lifetimes in aluminium by inelastic neutron scattering experiments, by ab initio molecular dynamics, and by perturbation theory. At elevated temperatures significant discrepancies are found between experiment and perturbation theory, which disappear when using molecular dynamics due to the inclusion of full anharmonicity and the correct treatment of the multiphonon background. We show that multiple-site interactions are small and that local pairwise anharmonicity dominates phonon-phonon interactions, which permits an efficient computation of phonon lifetimes.
- Open Access
- 16 March 2018
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 47 (16) , 5553-5557
Cooperativity in spin crossover materials as ligand's responsibility – investigations of the Fe(ii) – 1,3-bis((1H-tetrazol-1-yl)methyl)bicyclo[1.1.1]pentane system
In [Fe(ppditz)3]X2, X = BF4−, ClO4−, PF6− spin crossover complexes the observed cooperativity originates only from the rigidity and internal strain of the ligand.
- 16 March 2018
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 47 (16) , 5553-5557
Open AccessCooperativity in spin crossover materials as ligand's responsibility – investigations of the Fe(ii) – 1,3-bis((1H-tetrazol-1-yl)methyl)bicyclo[1.1.1]pentane system
In [Fe(ppditz)3]X2, X = BF4−, ClO4−, PF6− spin crossover complexes the observed cooperativity originates only from the rigidity and internal strain of the ligand.
- 15 January 2018
- Published by Wiley in Advanced Sustainable Systems
- Vol. 2 (1)
Thermochemical Energy Storage: Calcium Doping Facilitates Water Dissociation in Magnesium Oxide (Adv. Sustainable Syst. 1/2018)
- 15 January 2018
- Published by Wiley in Advanced Sustainable Systems
- Vol. 2 (1)
Thermochemical Energy Storage: Calcium Doping Facilitates Water Dissociation in Magnesium Oxide (Adv. Sustainable Syst. 1/2018)
- 11 December 2017
- Published by Wiley in Advanced Sustainable Systems
- Vol. 2 (1)
Calcium Doping Facilitates Water Dissociation in Magnesium Oxide
Calcium doping of magnesium oxide results in significantly increased water dissociation rates, thus enhancing both hydration rate and reaction completeness of hydration compared to pure MgO. For a series of mixed magnesium–calcium oxides (MgxCa1−xO) with varying Ca contents between 0% and 40%, the material of a composition Mg0.9Ca0.1O shows the fastest rehydration, transforming completely within 80 min to the mixed hydroxide. In consecutive dehydration/rehydration cycles, reasonable cycle stability is found. A “regeneration” of the aged material (reactivity reduced by excessive cycling) in liquid water re‐establishes the initial rehydration reactivity. Density functional theory calculations support the experimental findings, confirming that calcium doping can reduce the energy of the rate limiting water dissociation reaction, exploiting both electronic and steric (size) effects.
- 11 December 2017
- Published by Wiley in Advanced Sustainable Systems
- Vol. 2 (1)
Calcium Doping Facilitates Water Dissociation in Magnesium Oxide
Calcium doping of magnesium oxide results in significantly increased water dissociation rates, thus enhancing both hydration rate and reaction completeness of hydration compared to pure MgO. For a series of mixed magnesium–calcium oxides (MgxCa1−xO) with varying Ca contents between 0% and 40%, the material of a composition Mg0.9Ca0.1O shows the fastest rehydration, transforming completely within 80 min to the mixed hydroxide. In consecutive dehydration/rehydration cycles, reasonable cycle stability is found. A “regeneration” of the aged material (reactivity reduced by excessive cycling) in liquid water re‐establishes the initial rehydration reactivity. Density functional theory calculations support the experimental findings, confirming that calcium doping can reduce the energy of the rate limiting water dissociation reaction, exploiting both electronic and steric (size) effects.